User Guide
Page 5
...8226; Smoke or combustion detectors* designed to the opening of a Honeywell Security System. entry delay on AWAY: arms perimeter and all interior zones, entry delay is on MAXIMUM: same as STAY, except entry ...VISTA-20PSIA (VISTA-20P series) and VISTA-15P/VISTA-15PSIA (VISTA-15P series) security systems. Differences are noted where applicable. NOTE: Features and procedures described in this manual apply to a Central Monitoring Station. * Commercial installations and some residential systems may not include fire protection - check with different authority levels, which provides control...
...8226; Smoke or combustion detectors* designed to the opening of a Honeywell Security System. entry delay on AWAY: arms perimeter and all interior zones, entry delay is on MAXIMUM: same as STAY, except entry ...VISTA-20PSIA (VISTA-20P series) and VISTA-15P/VISTA-15PSIA (VISTA-15P series) security systems. Differences are noted where applicable. NOTE: Features and procedures described in this manual apply to a Central Monitoring Station. * Commercial installations and some residential systems may not include fire protection - check with different authority levels, which provides control...
User Guide
Page 15
...condition works the same as described above , but occurs if an entry/exit door or interior zone is also sent to the Central Monitoring Station. "Recent Closing" Condition (VISTA-20PSIA/VISTA-15PSIA only) A Recent Closing condition is similar to the Exit Error condition described above , except that... in your code plus OFF); If an entry/exit door or interior zone is faulted before the entry delay ends, the...
...condition works the same as described above , but occurs if an entry/exit door or interior zone is also sent to the Central Monitoring Station. "Recent Closing" Condition (VISTA-20PSIA/VISTA-15PSIA only) A Recent Closing condition is similar to the Exit Error condition described above , except that... in your code plus OFF); If an entry/exit door or interior zone is faulted before the entry delay ends, the...
Operation Guide
Page 5
.../Function VISTA-20P Series VISTA-15P Series Partitions • 2 partitions, can control devices and/or auto- can protect two independent VISTA-15P is enabled). certain system conditions Up to all zones (for False Alarm Reduction. SECTION 1 Features and Installation Highlights This manual applies to the following Honeywell security systems: ADEMCO VISTA-20P/ADEMCO VISTA-20PSIA/ADEMCO VISTA-20PCN (collectively referred to as VISTA-20P series), ADEMCO VISTA-15P/ADEMCO VISTA-15PSIA/ADEMCO VISTA...
.../Function VISTA-20P Series VISTA-15P Series Partitions • 2 partitions, can control devices and/or auto- can protect two independent VISTA-15P is enabled). certain system conditions Up to all zones (for False Alarm Reduction. SECTION 1 Features and Installation Highlights This manual applies to the following Honeywell security systems: ADEMCO VISTA-20P/ADEMCO VISTA-20PSIA/ADEMCO VISTA-20PCN (collectively referred to as VISTA-20P series), ADEMCO VISTA-15P/ADEMCO VISTA-15PSIA/ADEMCO VISTA...
Operation Guide
Page 39
...USED IN A CANADIAN INSTALLATION MUST BE LISTED FOR USE IN CANADA 6.2k TYPICAL WIRING FOR ZONE DOUBLING (VISTA-20P ONLY) ADEMCO VISTA-20P / VISTA-20PSIA SERIES / VISTA-15P / VISTA-15PSIA SERIES SUMMARY OF CONNECTIONS LO ZONE 8 HI VISTA-20P ONLY 21 22 23 24 25 TIP RING TIP RING (BROWN) (GRAY) (GREEN... CALCULATIONS. DETECTORS MUST HAVE COMPATIBILITY IDENTIFIER AS "A". 10 11 ZONE 2 3k ZONE 10 ZONE PAIRS 2 / 10 3 / 11 4 / 12 5 / 13 6 / 14 7 / 15 8 / 16 POWER SHUTDOWN NOTE: SYSTEM SHUTS DOWN SENSOR DETECTION PROCESSING IF CONTROL'S VOLTAGE DROPS BELOW 9.6V. WARNING:TO PREVENT RISK OF ...
...USED IN A CANADIAN INSTALLATION MUST BE LISTED FOR USE IN CANADA 6.2k TYPICAL WIRING FOR ZONE DOUBLING (VISTA-20P ONLY) ADEMCO VISTA-20P / VISTA-20PSIA SERIES / VISTA-15P / VISTA-15PSIA SERIES SUMMARY OF CONNECTIONS LO ZONE 8 HI VISTA-20P ONLY 21 22 23 24 25 TIP RING TIP RING (BROWN) (GRAY) (GREEN... CALCULATIONS. DETECTORS MUST HAVE COMPATIBILITY IDENTIFIER AS "A". 10 11 ZONE 2 3k ZONE 10 ZONE PAIRS 2 / 10 3 / 11 4 / 12 5 / 13 6 / 14 7 / 15 8 / 16 POWER SHUTDOWN NOTE: SYSTEM SHUTS DOWN SENSOR DETECTION PROCESSING IF CONTROL'S VOLTAGE DROPS BELOW 9.6V. WARNING:TO PREVENT RISK OF ...