User Guide
Page 4
... ...32 Authority Level Definitions ...32 How to Assign User Codes and Attributes 33 Accessing Other Partitions (VISTA-20P Series 34 About Accessing Partitions ...34 Using the GoTo Command ...35 Multi-Partition Arming ...35 Common Zone Operation (VISTA-20P Series 36 Scheduling...37 About Scheduling...37 Creating Schedules...37 Event Logging Procedures...39 About Event Logging...
... ...32 Authority Level Definitions ...32 How to Assign User Codes and Attributes 33 Accessing Other Partitions (VISTA-20P Series 34 About Accessing Partitions ...34 Using the GoTo Command ...35 Multi-Partition Arming ...35 Common Zone Operation (VISTA-20P Series 36 Scheduling...37 About Scheduling...37 Creating Schedules...37 Event Logging Procedures...39 About Event Logging...
User Guide
Page 5
check with different authority levels, which provides control of system and displays system status • ...: same as AWAY, except entry delay is off • You can BYPASS selected zones while leaving the rest of a Honeywell Security System. Security Codes • You were assigned a 4-digit security code during system...: arms perimeter zones and selected interior zones; Your system may also have been programmed to automatically send alarm or status messages over the phone lines to the VISTA-20P/VISTA-20PSIA (VISTA-20P series) and VISTA-15P/VISTA-15PSIA (VISTA-15P series) security ...
check with different authority levels, which provides control of system and displays system status • ...: same as AWAY, except entry delay is off • You can BYPASS selected zones while leaving the rest of a Honeywell Security System. Security Codes • You were assigned a 4-digit security code during system...: arms perimeter zones and selected interior zones; Your system may also have been programmed to automatically send alarm or status messages over the phone lines to the VISTA-20P/VISTA-20PSIA (VISTA-20P series) and VISTA-15P/VISTA-15PSIA (VISTA-15P series) security ...
User Guide
Page 6
... to access the system via a touch-tone phone, either on a sensor. • Partitions (VISTA-20P Series) provide two independent areas of protection, with each partition containing a group of zones that caused the problem, and displays the type of entering your installer if you can be cleared .... • The message remains displayed even after disarming the system, but can be armed and disarmed without affecting other zones or users. • Partitioned systems (VISTA-20P Series) can press the [#] key in STAY mode, you to 45 seconds. National Security Systems Inc (800) 457-1999...
... to access the system via a touch-tone phone, either on a sensor. • Partitions (VISTA-20P Series) provide two independent areas of protection, with each partition containing a group of zones that caused the problem, and displays the type of entering your installer if you can be cleared .... • The message remains displayed even after disarming the system, but can be armed and disarmed without affecting other zones or users. • Partitioned systems (VISTA-20P Series) can press the [#] key in STAY mode, you to 45 seconds. National Security Systems Inc (800) 457-1999...
User Guide
Page 7
... Macro sequence. National Security Systems Inc (800) 457-1999 LEDs READY • The volume control is recorded. MESSAGE 1 OFF RECORD 4 MAX 2 AWAY VOLUME 5 TEST 7 INSTANT 8 CODE 3 STAY PLAY 6 BYPASS 9 CHIME • Refer to four (VISTA-20P Series) or two (VISTA-15P Series) pagers. • The pager displays code numbers identifying the type of condition that...
... Macro sequence. National Security Systems Inc (800) 457-1999 LEDs READY • The volume control is recorded. MESSAGE 1 OFF RECORD 4 MAX 2 AWAY VOLUME 5 TEST 7 INSTANT 8 CODE 3 STAY PLAY 6 BYPASS 9 CHIME • Refer to four (VISTA-20P Series) or two (VISTA-15P Series) pagers. • The pager displays code numbers identifying the type of condition that...
User Guide
Page 14
You can be used for your system in any time - These modes provide greater security while on VISTA-20P Series only Exit Delay: seconds Entry Delay 1: seconds Entry Delay 2: seconds Exit Delay Exit delay gives you time to leave through the designated... entrance door. Partition 2 (on the premises or while away for partition 1 also apply to the Common Zone of the VISTA-20P Series. National Security Systems Inc (800) 457-1999 There are two entry delays (if programmed). Partition 1 Exit Delay: seconds Entry Delay 1: ...
You can be used for your system in any time - These modes provide greater security while on VISTA-20P Series only Exit Delay: seconds Entry Delay 1: seconds Entry Delay 2: seconds Exit Delay Exit delay gives you time to leave through the designated... entrance door. Partition 2 (on the premises or while away for partition 1 also apply to the Common Zone of the VISTA-20P Series. National Security Systems Inc (800) 457-1999 There are two entry delays (if programmed). Partition 1 Exit Delay: seconds Entry Delay 1: ...
User Guide
Page 18
..." sound after arming, if programmed to do so. If so, you that entry delay is set for your installer for information on multi-partition arming (VISTA-20P Series only). - 18 -
..." sound after arming, if programmed to do so. If so, you that entry delay is set for your installer for information on multi-partition arming (VISTA-20P Series only). - 18 -
User Guide
Page 27
...macro functions can be programmed at the "Select Macro?" Remember, only one macro to a key. • Macros can be assigned - Bypassing particular zone(s) - but no more than one macro can be activated only by users with the next prompt. NOTE: The installer must activate the desired function key... appears as a group, are called "macros" and are shown on (or off) lights, fans, etc. • Up to four (VISTA-20P Series) or two (VISTA-15P Series) macros can be assigned to perform the macro's function. prompt. If a macro has been previously defined, the keystrokes are stored in the...
...macro functions can be programmed at the "Select Macro?" Remember, only one macro to a key. • Macros can be assigned - Bypassing particular zone(s) - but no more than one macro can be activated only by users with the next prompt. NOTE: The installer must activate the desired function key... appears as a group, are called "macros" and are shown on (or off) lights, fans, etc. • Up to four (VISTA-20P Series) or two (VISTA-15P Series) macros can be assigned to perform the macro's function. prompt. If a macro has been previously defined, the keystrokes are stored in the...
User Guide
Page 30
...Troubles. that disarmed the system. 102 = Close (system armed). and user no . CCCC Å 1-digit Partition No. + 3-digit Zone No. A = Optional 16-digits for VISTA-15P Series) as follows: Optional 16 digits 3-digit Event Code È È AAAAAAAAAAAAAAAA - Open The 4-digit number The 4-digit number (...) that has occurred. • An optional, predefined 16-digit character string can be sent to several pagers (4 pagers for VISTA-20P Series, 2 pagers for Account numbers, PIN numbers, or any additional data that someone has not arrived home (disarmed the system...
...Troubles. that disarmed the system. 102 = Close (system armed). and user no . CCCC Å 1-digit Partition No. + 3-digit Zone No. A = Optional 16-digits for VISTA-15P Series) as follows: Optional 16 digits 3-digit Event Code È È AAAAAAAAAAAAAAAA - Open The 4-digit number The 4-digit number (...) that has occurred. • An optional, predefined 16-digit character string can be sent to several pagers (4 pagers for VISTA-20P Series, 2 pagers for Account numbers, PIN numbers, or any additional data that someone has not arrived home (disarmed the system...
User Guide
Page 32
...assigned user numbers) and a security code. Cannot perform system functions reserved for user 02; National Security Systems Inc (800) 457-1999 VISTA-15P Series provides 31 additional codes). • Only the System Master and Partition Master can assign user codes to users. • Users...functions. 2 Guest: Can arm the system in assigned partition. Assign an authority level to that service has been provided. 4 Partition Master (VISTA-20P Series) Can do everything a standard user can do, and can be operating, and assign a 4-digit security code. 2. Authority Level ...
...assigned user numbers) and a security code. Cannot perform system functions reserved for user 02; National Security Systems Inc (800) 457-1999 VISTA-15P Series provides 31 additional codes). • Only the System Master and Partition Master can assign user codes to users. • Users...functions. 2 Guest: Can arm the system in assigned partition. Assign an authority level to that service has been provided. 4 Partition Master (VISTA-20P Series) Can do everything a standard user can do, and can be operating, and assign a 4-digit security code. 2. Authority Level ...
User Guide
Page 33
...Authority Level: Factory Defaults: users 04-32/34-49 = 0 users 03/33 = 4 Access Group: Factory Defaults:: none User's Partition: (VISTA-20P only) Factory Defaults: Part. 1 = users 03-32 Part. 2 = users 33-49 RF User Number: Factory Defaults:: none Pager On/...= master User 33 = partition 2 master The Keypad beeps once to confirm that new user was added. Zone number: enter the zone number assigned to a button on previous page): 0 = standard user 3 = duress 1 = arm only 4 = partition master (VISTA-20P Series 2 = guest only) System/Partition Master Code + [8] + [user no .] + [#] [1]+ ...
...Authority Level: Factory Defaults: users 04-32/34-49 = 0 users 03/33 = 4 Access Group: Factory Defaults:: none User's Partition: (VISTA-20P only) Factory Defaults: Part. 1 = users 03-32 Part. 2 = users 33-49 RF User Number: Factory Defaults:: none Pager On/...= master User 33 = partition 2 master The Keypad beeps once to confirm that new user was added. Zone number: enter the zone number assigned to a button on previous page): 0 = standard user 3 = duress 1 = arm only 4 = partition master (VISTA-20P Series 2 = guest only) System/Partition Master Code + [8] + [user no .] + [#] [1]+ ...
User Guide
Page 34
... be disarmed. Refer to perform system functions in partition 1 shows the status of partition 2 and the common zone. See Condition 1 above . - 34 - Accessing Other Partitions (VISTA-20P) About Accessing Partitions (GOTO Command and Multi-Partition Arming) Each keypad is assigned a default partition for its partition only. When partition 1 is disarmed and partition 2 ...
... be disarmed. Refer to perform system functions in partition 1 shows the status of partition 2 and the common zone. See Condition 1 above . - 34 - Accessing Other Partitions (VISTA-20P) About Accessing Partitions (GOTO Command and Multi-Partition Arming) Each keypad is assigned a default partition for its partition only. When partition 1 is disarmed and partition 2 ...
User Guide
Page 35
... + [∗] + partition number (0,1,2,3) Alpha Display: (Security Code) 0 = return to keypad's original partition. 1 = partition 1; 2 = partition 2; 3 = common zone The keypad beeps to confirm the partition change. 1 DISARMED READY TO ARM Fixed-Word Display: Green LED lit 2. Alpha Display: 2 DISARMED READY TO ARM Fixed... partition by being assigned to both partitions when programming user attributes. Accessing Other Partitions (cont'd) Using the GoTo Command (VISTA-20P) If the user is authorized, a keypad in one partition can be given Multi-Partition arming ability by using the GOTO...
... + [∗] + partition number (0,1,2,3) Alpha Display: (Security Code) 0 = return to keypad's original partition. 1 = partition 1; 2 = partition 2; 3 = common zone The keypad beeps to confirm the partition change. 1 DISARMED READY TO ARM Fixed-Word Display: Green LED lit 2. Alpha Display: 2 DISARMED READY TO ARM Fixed... partition by being assigned to both partitions when programming user attributes. Accessing Other Partitions (cont'd) Using the GoTo Command (VISTA-20P) If the user is authorized, a keypad in one partition can be given Multi-Partition arming ability by using the GOTO...
User Guide
Page 36
... • Either partition can clear and restore the common zone after an alarm. • Entry/exit time for partition 1. - 36 - Accessing Other Partitions (cont'd) Common Zone Operation (VISTA-20P) Ask your installer if a "common zone" was assigned. National Security Systems Inc (800) 457-1999... If so, please note the following: • The common zone will sound and report alarms only when both partitions are...
... • Either partition can clear and restore the common zone after an alarm. • Entry/exit time for partition 1. - 36 - Accessing Other Partitions (cont'd) Common Zone Operation (VISTA-20P) Ask your installer if a "common zone" was assigned. National Security Systems Inc (800) 457-1999... If so, please note the following: • The common zone will sound and report alarms only when both partitions are...
User Guide
Page 37
... when the word "REMINDER" is skipped. RELAY NUMBER 00 - 37 - Enter the desired 2-digit event number from : 01-16 (VISTA-20P Series) or 01-04 (VISTA-15P Series) ENTER SCHED NO. For event number "01," enter the output number associated with this prompt is first displayed, and the display ...at a specified time 06 = automatically disarm the system at a specified time 07 = Display the word "REMINDER" at various intervals. • Schedules can control various types of access groups) 03 = send a "latch-key" report to a pager if the system is not disarmed by master/installer only), which can...
... when the word "REMINDER" is skipped. RELAY NUMBER 00 - 37 - Enter the desired 2-digit event number from : 01-16 (VISTA-20P Series) or 01-04 (VISTA-15P Series) ENTER SCHED NO. For event number "01," enter the output number associated with this prompt is first displayed, and the display ...at a specified time 06 = automatically disarm the system at a specified time 07 = Display the word "REMINDER" at various intervals. • Schedules can control various types of access groups) 03 = send a "latch-key" report to a pager if the system is not disarmed by master/installer only), which can...
User Guide
Page 39
... by an R, it means that follows) • zone or user number (depending on type of event) • partition in which can be viewed by the master user on an Alpha Display keypad. • The Event Log holds up to 100 (VISTA-20P Series) or 50 (VISTA-15P Series) events. • Events are displayed in chronological...
... by an R, it means that follows) • zone or user number (depending on type of event) • partition in which can be viewed by the master user on an Alpha Display keypad. • The Event Log holds up to 100 (VISTA-20P Series) or 50 (VISTA-15P Series) events. • Events are displayed in chronological...
User Guide
Page 55
... Arm Quick Bypass Automatic Paging Keyswitch Arming (circle type of LED lighting) Comments Part. 1: Part. 2*: Part. 1: Part. 2*: Part. 1: Part. 2*: Zones: yes no yes no yes no users: Arm AWAY: steady Arm STAY: steady flash flash Function Keys A B C D Comments • Single-Button Arming...; Emergency Key**: Audible Alarm • Emergency Key**: Fire • Device Activation Device: * Features marked with this single asterisk apply to the VISTA-20P Series only. ** Emergency Keys: A = [1] / [∗] B C = [3] / [#] National Security Systems Inc (800) 457-1999 - 55 -
... Arm Quick Bypass Automatic Paging Keyswitch Arming (circle type of LED lighting) Comments Part. 1: Part. 2*: Part. 1: Part. 2*: Part. 1: Part. 2*: Zones: yes no yes no yes no users: Arm AWAY: steady Arm STAY: steady flash flash Function Keys A B C D Comments • Single-Button Arming...; Emergency Key**: Audible Alarm • Emergency Key**: Fire • Device Activation Device: * Features marked with this single asterisk apply to the VISTA-20P Series only. ** Emergency Keys: A = [1] / [∗] B C = [3] / [#] National Security Systems Inc (800) 457-1999 - 55 -
User Guide
Page 56
... (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) - 56 - System Features Log (cont'd) User Setup The following chart will help keep track of system users. Copies should be distributed to the VISTA-20P Series only. Level [#] [1] + level Access Group [#] [2] + group installer master (4) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) RF Zone Pager Number on/off [#] [4] + zone no . + "#" command listed in column heading.
... (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) - 56 - System Features Log (cont'd) User Setup The following chart will help keep track of system users. Copies should be distributed to the VISTA-20P Series only. Level [#] [1] + level Access Group [#] [2] + group installer master (4) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) RF Zone Pager Number on/off [#] [4] + zone no . + "#" command listed in column heading.
User Guide
Page 57
...is partition 2 master for VISTA-20P Series, and the last user for VISTA-15P Series. Key 2 3** 4** ** Pagers 3 and 4 and partitions apply to VISTA-20P Series only; Security Auth. Access RF Zone Pager No.* Name (system master only) Code Level Group Number on/off [#] [3] + part(s) + [#] enter new code [#] [1] + level [#] [2] + group [#] [4] + zone no. [#] [5] + ... master code + [8] + user no paging; 1 = allow paging * Users 34-49 apply to VISTA-20P Series only. - 57 - Paging Setup Pager Phone Number\ Pager Prefix Characters 1 Automatically Reports Upon...
...is partition 2 master for VISTA-20P Series, and the last user for VISTA-15P Series. Key 2 3** 4** ** Pagers 3 and 4 and partitions apply to VISTA-20P Series only; Security Auth. Access RF Zone Pager No.* Name (system master only) Code Level Group Number on/off [#] [3] + part(s) + [#] enter new code [#] [1] + level [#] [2] + group [#] [4] + zone no. [#] [5] + ... master code + [8] + user no paging; 1 = allow paging * Users 34-49 apply to VISTA-20P Series only. - 57 - Paging Setup Pager Phone Number\ Pager Prefix Characters 1 Automatically Reports Upon...
User Guide
Page 58
... can only use schedules 01-04.) ** Partitions apply to the VISTA-20P Series only. VISTA-15P Series can use schedules 01-16; VISTA-15P Series can use devices 01-16; Partition** Start Stop (see list below) for "01" events: for "02" events: for "04-06" events: Time/ Time/ (...reminder" 02 = user access 05 = forced AWAY arm Repeat Options: 0 = none; 1 = repeat weekly; 2 = repeat every other week; 3 = repeat every third week; 4 = repeat every fourth week * VISTA-20P Series can only use trigger devices 17/18.) - 58 - List of Output Devices Device** 01 02 03 04 05 06 07 08 09 10 11...
... can only use schedules 01-04.) ** Partitions apply to the VISTA-20P Series only. VISTA-15P Series can use schedules 01-16; VISTA-15P Series can use devices 01-16; Partition** Start Stop (see list below) for "01" events: for "02" events: for "04-06" events: Time/ Time/ (...reminder" 02 = user access 05 = forced AWAY arm Repeat Options: 0 = none; 1 = repeat weekly; 2 = repeat every other week; 3 = repeat every third week; 4 = repeat every fourth week * VISTA-20P Series can only use trigger devices 17/18.) - 58 - List of Output Devices Device** 01 02 03 04 05 06 07 08 09 10 11...
User Guide
Page 59
...-1999 - 59 - A. NOTIFIES (Insert B = Burglary, F = Fire) Local Sounding Device Police Dept. With Rechargeable Power Supply D. GENERAL INFORMATION: Insured's Name and Address: Insurance Company: Policy No.: VISTA-20P / VISTA-15P Other (circle the appropriate model number) Type of Alarm: Burglary Fire Both Installed by: Name Serviced by: Address B. POWERED BY: A.C. TESTING: Quarterly Monthly Weekly continued...
...-1999 - 59 - A. NOTIFIES (Insert B = Burglary, F = Fire) Local Sounding Device Police Dept. With Rechargeable Power Supply D. GENERAL INFORMATION: Insured's Name and Address: Insurance Company: Policy No.: VISTA-20P / VISTA-15P Other (circle the appropriate model number) Type of Alarm: Burglary Fire Both Installed by: Name Serviced by: Address B. POWERED BY: A.C. TESTING: Quarterly Monthly Weekly continued...