Safety and Regulatory Information
Page 28
...-2006. Table 2-2 Toxic and Hazardous Substances and Elements Part Name Lead (Pb) Mercury (Hg) Cadmium (Cd) Hexavalent Chromium (Cr(VI)) Motherboard, processor and heat sink X O O O Memory X O O O I/O PCAs X O O O Power supply X O O O Keyboard X O O O Mouse X O O O Chassis/Other X O O O Fans X O O O Internal/External Media Reading X O O O Devices External Control Devices X O O O Cable X O O O Hard Disk Drive X O O O Display X X O O Polybrom i- nated biphenyls (PBB...
...-2006. Table 2-2 Toxic and Hazardous Substances and Elements Part Name Lead (Pb) Mercury (Hg) Cadmium (Cd) Hexavalent Chromium (Cr(VI)) Motherboard, processor and heat sink X O O O Memory X O O O I/O PCAs X O O O Power supply X O O O Keyboard X O O O Mouse X O O O Chassis/Other X O O O Fans X O O O Internal/External Media Reading X O O O Devices External Control Devices X O O O Cable X O O O Hard Disk Drive X O O O Display X X O O Polybrom i- nated biphenyls (PBB...
HP Z210 CMT Workstation Maintenance and Service Guide
Page 5
Table of contents 1 Product overview ...1 Product features ...1 System board architecture 1 Processor technology 2 Memory technology 2 Graphics 3 Expansion card slots 3 Additional features 3 Workstation components 4 Chassis components 4 Front panel components 5 Rear panel components 6 Workstation ...mode 13 Disabling ERP compliance mode 13 Accessibility ...13 Hyper-threading ...13 SATA Power Management 14 Intel Turbo Boost Technology 14 HP Cool Tools ...14 Ensuring proper ventilation 15 2 Setting up the operating system 16 Setting up the Microsoft operating system 17...
Table of contents 1 Product overview ...1 Product features ...1 System board architecture 1 Processor technology 2 Memory technology 2 Graphics 3 Expansion card slots 3 Additional features 3 Workstation components 4 Chassis components 4 Front panel components 5 Rear panel components 6 Workstation ...mode 13 Disabling ERP compliance mode 13 Accessibility ...13 Hyper-threading ...13 SATA Power Management 14 Intel Turbo Boost Technology 14 HP Cool Tools ...14 Ensuring proper ventilation 15 2 Setting up the operating system 16 Setting up the Microsoft operating system 17...
HP Z210 CMT Workstation Maintenance and Service Guide
Page 9
Installing the rear system fan assembly 82 Memory ...83 Supported DIMM configurations 83 DIMM installation guidelines 83 DIMM installation order 83 BIOS errors and warnings 84 Removing a DIMM 84 Installing a DIMM 85 Expansion ...
Installing the rear system fan assembly 82 Memory ...83 Supported DIMM configurations 83 DIMM installation guidelines 83 DIMM installation order 83 BIOS errors and warnings 84 Removing a DIMM 84 Installing a DIMM 85 Expansion ...
HP Z210 CMT Workstation Maintenance and Service Guide
Page 10
... Diagnostics Utilities 128 Creating and using a bootable USB key 128 Creating and using a bootable DVD/CD 128 Using the HP Memory Test utility 128 Downloading HP Vision Diagnostics 130 User interface ...131 Survey tab 131 Test tab 132 Status tab 133 History tab 134 Errors tab 134 Help tab ...134 Saving and printing information in HP Vision Diagnostics 135 Diagnostic codes and errors 135 Diagnostic LED and audible (beep) codes 135 LED color definitions 139 POST error messages 140 x ...
... Diagnostics Utilities 128 Creating and using a bootable USB key 128 Creating and using a bootable DVD/CD 128 Using the HP Memory Test utility 128 Downloading HP Vision Diagnostics 130 User interface ...131 Survey tab 131 Test tab 132 Status tab 133 History tab 134 Errors tab 134 Help tab ...134 Saving and printing information in HP Vision Diagnostics 135 Diagnostic codes and errors 135 Diagnostic LED and audible (beep) codes 135 LED color definitions 139 POST error messages 140 x ...
HP Z210 CMT Workstation Maintenance and Service Guide
Page 14
...the processor and I/O controller. NOTE: To optimize performance, distribute the DIMMs across both memory channels. The following figure shows the typical system board block diagram. The number in -line memory modules (DIMMs) are supported. Error checking and correcting (ECC) and non-ECC DIMMs... microarchitecture improvements, integrated graphics (some models) and Advanced Vector Extensions (AVX) to the expansion slot. See Memory on DDR3 1066/1333MHz technology. System memory sizes up to 32GB (using 8GB DIMMs) are supported. Figure 1-1 System board block diagram NOTE: The x1...
...the processor and I/O controller. NOTE: To optimize performance, distribute the DIMMs across both memory channels. The following figure shows the typical system board block diagram. The number in -line memory modules (DIMMs) are supported. Error checking and correcting (ECC) and non-ECC DIMMs... microarchitecture improvements, integrated graphics (some models) and Advanced Vector Extensions (AVX) to the expansion slot. See Memory on DDR3 1066/1333MHz technology. System memory sizes up to 32GB (using 8GB DIMMs) are supported. Figure 1-1 System board block diagram NOTE: The x1...
HP Z210 CMT Workstation Maintenance and Service Guide
Page 15
..., visit http://www.hp.com/go /quickspecs. To view supported graphic card configurations using the Computer (F10) Setup Utility. one x16(4) PCIe2, one full x16 PCIe2; two x1 PCIe2; NOTE: Do not intermix non-ECC memory DIMMs with integrated Intel HD graphics. Some workstation models... (depending on installed processor type) also support up to two displays with ECC memory DIMMs. Graphics The workstation supports discrete PCIe Gen2 graphics cards in order to http://www.hp.com/go / quickspecs, select your geographic region, click on "Workstations," then select your ...
..., visit http://www.hp.com/go /quickspecs. To view supported graphic card configurations using the Computer (F10) Setup Utility. one x16(4) PCIe2, one full x16 PCIe2; two x1 PCIe2; NOTE: Do not intermix non-ECC memory DIMMs with integrated Intel HD graphics. Some workstation models... (depending on installed processor type) also support up to two displays with ECC memory DIMMs. Graphics The workstation supports discrete PCIe Gen2 graphics cards in order to http://www.hp.com/go / quickspecs, select your geographic region, click on "Workstations," then select your ...
HP Z210 CMT Workstation Maintenance and Service Guide
Page 16
... shows the chassis components of a typical HP Z210 CMT Workstation layout. For complete and current information on supported accessories and components for the workstation, see http://partsurfer.hp.com. Drive configurations can vary. Figure 1-2 Workstation chassis components Table 1-1 Workstation component descriptions Item Description Item Description 1 Power supply 8 Memory module (DIMM) 2 Side access panel 9 PCIe...
... shows the chassis components of a typical HP Z210 CMT Workstation layout. For complete and current information on supported accessories and components for the workstation, see http://partsurfer.hp.com. Drive configurations can vary. Figure 1-2 Workstation chassis components Table 1-1 Workstation component descriptions Item Description Item Description 1 Power supply 8 Memory module (DIMM) 2 Side access panel 9 PCIe...
HP Z210 CMT Workstation Maintenance and Service Guide
Page 38
... restore factory default settings. ● Set the computer date and time. ● Set, view, change or verify the computer configuration, including settings for CPU, graphics, memory, audio, storage, communications and input devices. ● Modify the boot order of installed mass storage devices such as...
... restore factory default settings. ● Set the computer date and time. ● Set, view, change or verify the computer configuration, including settings for CPU, graphics, memory, audio, storage, communications and input devices. ● Modify the boot order of installed mass storage devices such as...
HP Z210 CMT Workstation Maintenance and Service Guide
Page 39
..., use the up and down arrow keys to accept the changes, and then select Apply Defaults and Exit. A loss of power could corrupt the CMOS memory. Press F10 to select an option, and then press Enter. 5. Accessing the Computer Setup (F10) Utility To access the Computer Setup (F10) Utility ...: ● To apply and save changes, select File > Save Changes, and then select F10=YES. ● To remove changes you miss the opportunity to CMOS memory. NOTE: Help screens (accessed by pressing F1) are displayed: File, Storage, Security, Power, and Advanced. 4. If you can also press Ctrl + Alt + ...
..., use the up and down arrow keys to accept the changes, and then select Apply Defaults and Exit. A loss of power could corrupt the CMOS memory. Press F10 to select an option, and then press Enter. 5. Accessing the Computer Setup (F10) Utility To access the Computer Setup (F10) Utility ...: ● To apply and save changes, select File > Save Changes, and then select F10=YES. ● To remove changes you miss the opportunity to CMOS memory. NOTE: Help screens (accessed by pressing F1) are displayed: File, Storage, Security, Power, and Advanced. 4. If you can also press Ctrl + Alt + ...
HP Z210 CMT Workstation Maintenance and Service Guide
Page 40
... Name ● SKU Number ● Processor Type ● Processor Speed ● Processor Stepping (stepping designation and patch number) ● Cache Size (L1/L2/L3) ● Memory Size ● Integrated MAC (onboard NIC) ● System BIOS ● Chassis Serial Number ● Asset Tracking Number ● ME (Intel Management Engine) Firmware Version ●...
... Name ● SKU Number ● Processor Type ● Processor Speed ● Processor Stepping (stepping designation and patch number) ● Cache Size (L1/L2/L3) ● Memory Size ● Integrated MAC (onboard NIC) ● System BIOS ● Chassis Serial Number ● Asset Tracking Number ● ME (Intel Management Engine) Firmware Version ●...
HP Z210 CMT Workstation Maintenance and Service Guide
Page 45
...Maximum Power Savings Thermal Lets you specify computer behavior after the Xth day and no more memory counts until that boot occurs. Clears memory on all boots. ◦ FullBoot Every x Days-Memory count on first cold boot on or after a power loss: ◦ Power Off-Computer...On Options Sets the following: ● POST Mode: ◦ QuickBoot-Do not clear memory or perform a memory test. ◦ FullBoot-Memory test (count) on cold boot. Clears memory on all boots. ◦ Clear Memory-No memory test (count) on cold boot. extended mode reduces processor power consumption when the CPU...
...Maximum Power Savings Thermal Lets you specify computer behavior after the Xth day and no more memory counts until that boot occurs. Clears memory on all boots. ◦ FullBoot Every x Days-Memory count on first cold boot on or after a power loss: ◦ Power Off-Computer...On Options Sets the following: ● POST Mode: ◦ QuickBoot-Do not clear memory or perform a memory test. ◦ FullBoot-Memory test (count) on cold boot. Clears memory on all boots. ◦ Clear Memory-No memory test (count) on cold boot. extended mode reduces processor power consumption when the CPU...
HP Z210 CMT Workstation Maintenance and Service Guide
Page 47
... about Intel AMT can be found at Power-On (On/Off) ● Integrated Video1 (Enabled/Disabled) ● IGD (Integrated Graphics Device) Memory-Displayed when Integrated Video is set) does not need to be used by advanced users only ENWW The Computer Setup (F10) Utility 35 Selective disabling... ROM Download for each slot. A Setup Password (even if one is Enabled. Sets the maximum amount of Option ROM downloads can be allocated as graphics memory (32, 64 (default), 128, 256, 512 MB)1 ● Internal Speaker (Enabled/Disabled) ● NIC Option ROM2 Download (PXE/Disabled) ●...
... about Intel AMT can be found at Power-On (On/Off) ● Integrated Video1 (Enabled/Disabled) ● IGD (Integrated Graphics Device) Memory-Displayed when Integrated Video is set) does not need to be used by advanced users only ENWW The Computer Setup (F10) Utility 35 Selective disabling... ROM Download for each slot. A Setup Password (even if one is Enabled. Sets the maximum amount of Option ROM downloads can be allocated as graphics memory (32, 64 (default), 128, 256, 512 MB)1 ● Internal Speaker (Enabled/Disabled) ● NIC Option ROM2 Download (PXE/Disabled) ●...
HP Z210 CMT Workstation Maintenance and Service Guide
Page 51
.../go/ssm. ● How HP CMS works ● Which solutions are standards-based solutions for managing and controlling computers in the hardware environment ● Web-accessible reporting of business-critical details such as thermal warnings and memory alerts ● Remote updating of system ...software such as device drivers and ROM BIOS ● Remote changing of boot order ● Configuration of system BIOS settings The HP Client Management Solutions (CMS), available for asset ...
.../go/ssm. ● How HP CMS works ● Which solutions are standards-based solutions for managing and controlling computers in the hardware environment ● Web-accessible reporting of business-critical details such as thermal warnings and memory alerts ● Remote updating of system ...software such as device drivers and ROM BIOS ● Remote changing of boot order ● Configuration of system BIOS settings The HP Client Management Solutions (CMS), available for asset ...
HP Z210 CMT Workstation Maintenance and Service Guide
Page 54
... attempting system access. ● Security features such as options on the HP computer: ● Locally, using the Computer Setup (F10) Utility ● Remotely, using HP Systems Insight Manager (HP SIM), HP CMS, or other systems-management applications. The following utilities to choose the... ENWW Seamless, automatic integration between asset tracking features and these products enables you can protect valuable data assets. ● Memory Change and Side access panel sensor (Smart Cover Sensor) alerts can be forwarded to system management applications to the management of...
... attempting system access. ● Security features such as options on the HP computer: ● Locally, using the Computer Setup (F10) Utility ● Remotely, using HP Systems Insight Manager (HP SIM), HP CMS, or other systems-management applications. The following utilities to choose the... ENWW Seamless, automatic integration between asset tracking features and these products enables you can protect valuable data assets. ● Memory Change and Side access panel sensor (Smart Cover Sensor) alerts can be forwarded to system management applications to the management of...
HP Z210 CMT Workstation Maintenance and Service Guide
Page 63
... acceptable, efficient chassis temperature. Thermal sensors Several thermal sensors in select HP computers. The solenoid lock FailSafe Key-available from HP-is is managed by HP CMS, the computer sends a fault notice to the network management application. With HP CMS, you experience noncorrectable memory errors. Drive Protection System The Drive Protection System (DPS) is a diagnostic...
... acceptable, efficient chassis temperature. Thermal sensors Several thermal sensors in select HP computers. The solenoid lock FailSafe Key-available from HP-is is managed by HP CMS, the computer sends a fault notice to the network management application. With HP CMS, you experience noncorrectable memory errors. Drive Protection System The Drive Protection System (DPS) is a diagnostic...
HP Z210 CMT Workstation Maintenance and Service Guide
Page 73
... 4 Chassis intrusion 16 Crisis recovery jumper 28 PCIe2 x16 5 CPU socket 17 Front chassis fan 29 PCIe2 x8(4) 6 CPU fan 18 System speaker 30 Audio 7 Memory sockets 19 3rd internal USB 31 USB 8 Main Power 20 Password jumper 32 Network/USB 9 Front power button/LED 21 Serial 33 DP display port...
... 4 Chassis intrusion 16 Crisis recovery jumper 28 PCIe2 x16 5 CPU socket 17 Front chassis fan 29 PCIe2 x8(4) 6 CPU fan 18 System speaker 30 Audio 7 Memory sockets 19 3rd internal USB 31 USB 8 Main Power 20 Password jumper 32 Network/USB 9 Front power button/LED 21 Serial 33 DP display port...
HP Z210 CMT Workstation Maintenance and Service Guide
Page 75
... to access major workstation components. Then remove... Then remove... Use the following table to determine the sequence in a particular order. Battery, front bezel, hard drive, memory, power supply, rear system fan, side access panel sensor, or solenoid lock Chassis lock Side access panel Processor Chassis lock Side access panel Heatsink Expansion...
... to access major workstation components. Then remove... Then remove... Use the following table to determine the sequence in a particular order. Battery, front bezel, hard drive, memory, power supply, rear system fan, side access panel sensor, or solenoid lock Chassis lock Side access panel Processor Chassis lock Side access panel Heatsink Expansion...
HP Z210 CMT Workstation Maintenance and Service Guide
Page 95
...; For ECC DIMMs, use only industry-standard ECC unbuffered DIMMs. See http://www.hp.com/ go/quickspecs to find which DIMMs are compatible with the workstation. ● Do not intermix non-ECC memory DIMMs with ECC memory DIMMs. DIMM installation order Review the following to 32 GB ● No support for mirroring ●...
...; For ECC DIMMs, use only industry-standard ECC unbuffered DIMMs. See http://www.hp.com/ go/quickspecs to find which DIMMs are compatible with the workstation. ● Do not intermix non-ECC memory DIMMs with ECC memory DIMMs. DIMM installation order Review the following to 32 GB ● No support for mirroring ●...
HP Z210 CMT Workstation Maintenance and Service Guide
Page 96
... and reports a warning during POST. BIOS errors and warnings The BIOS generates warnings/errors on invalid memory configurations: ● If the BIOS can still be started. The workstation can find a valid memory configuration by disabling plugged-in the following figure. Removing a DIMM To remove a DIMM: 1. The... warning will not recognize the memory changes if the DIMM is no way for memory error (five beeps and blinks). Push gently outward on the DIMM socket levers (1) as shown in memory, the BIOS halts with a diagnostics code for the BIOS to the DIMMs...
... and reports a warning during POST. BIOS errors and warnings The BIOS generates warnings/errors on invalid memory configurations: ● If the BIOS can still be started. The workstation can find a valid memory configuration by disabling plugged-in the following figure. Removing a DIMM To remove a DIMM: 1. The... warning will not recognize the memory changes if the DIMM is no way for memory error (five beeps and blinks). Push gently outward on the DIMM socket levers (1) as shown in memory, the BIOS halts with a diagnostics code for the BIOS to the DIMMs...
HP Z210 CMT Workstation Maintenance and Service Guide
Page 97
Disconnect power from the AC power outlet before removing or installing memory. CAUTION: To prevent possible electrical damage to the DIMMs, power off the workstation and unplug the power cord from the workstation (see Removing the side ... DIMM: 1. Figure 5-26 Opening DIMM socket levers ENWW Removing and installing components 85 Push gently outward on page 62). The workstation will not recognize the memory changes if the DIMM is damaged. 2. Remove the side access panel (see Predisassembly procedures on the DIMM socket levers as shown in the following figure.
Disconnect power from the AC power outlet before removing or installing memory. CAUTION: To prevent possible electrical damage to the DIMMs, power off the workstation and unplug the power cord from the workstation (see Removing the side ... DIMM: 1. Figure 5-26 Opening DIMM socket levers ENWW Removing and installing components 85 Push gently outward on page 62). The workstation will not recognize the memory changes if the DIMM is damaged. 2. Remove the side access panel (see Predisassembly procedures on the DIMM socket levers as shown in the following figure.