HP Smart Array SAS controllers for Integrity servers support guide
Page 39
ARRAY ACCELERATOR (CACHE) INFORMATION Array Accelerator Board Present?.... SAS/SATA DEVICE 1I:1:12:0x500000e01117c732 [DISK Connector Location internal Connector 1I Enclosure 1 Bay 12 WWID 0x500000e01117c732 Device Type DISK Disk Capacity 36.4 GB Device Status OK Device Vendor ID HP Device Product ID DG036A8B5B Device Serial... Device Type DISK Disk Capacity 36.4 GB Device Status OK Confirming and updating physical disk firmware 39 cache enabled Cache Ratio 50% Read / 50% Write Total Cache Size (MB 208 Battery Pack Count 1 Battery Status (pack #1 ok ---- yes...
ARRAY ACCELERATOR (CACHE) INFORMATION Array Accelerator Board Present?.... SAS/SATA DEVICE 1I:1:12:0x500000e01117c732 [DISK Connector Location internal Connector 1I Enclosure 1 Bay 12 WWID 0x500000e01117c732 Device Type DISK Disk Capacity 36.4 GB Device Status OK Device Vendor ID HP Device Product ID DG036A8B5B Device Serial... Device Type DISK Disk Capacity 36.4 GB Device Status OK Confirming and updating physical disk firmware 39 cache enabled Cache Ratio 50% Read / 50% Write Total Cache Size (MB 208 Battery Pack Count 1 Battery Status (pack #1 ok ---- yes...
HP Smart Array SAS controllers for Integrity servers support guide
Page 51
Read caching percentage can be 0, 25, 50, 75, or 100. The stripe size is in KB. The stripe size is in KB. See "Determining the Smart Array ... for more information, see saconfig(I -l To extend the capacity of each physical disk attached to larger capacity. To enable or disable auto-fail missing disks at Boot Cache Configuration Status Cache Ratio = enabled = cache enabled = 50% Read / 50% Write ---------- saconfig /dev/cissX -E -c To expand the specified logical drive and others in GB. saconfig /dev/cissX -M -R [-S ] To perform...
Read caching percentage can be 0, 25, 50, 75, or 100. The stripe size is in KB. The stripe size is in KB. See "Determining the Smart Array ... for more information, see saconfig(I -l To extend the capacity of each physical disk attached to larger capacity. To enable or disable auto-fail missing disks at Boot Cache Configuration Status Cache Ratio = enabled = cache enabled = 50% Read / 50% Write ---------- saconfig /dev/cissX -E -c To expand the specified logical drive and others in GB. saconfig /dev/cissX -M -R [-S ] To perform...
HP Smart Array SAS controllers for Integrity servers support guide
Page 53
... example, a logical drive is applied to the logical drive. The RAID level is set at 1, the stripe size is set at Boot Cache Configuration Status Cache Ratio = enabled = cache enabled = 25% Read / 75% Write ---------- Device File RAID Level Size Stripe Size Status = c5t0d0 = 1+0 = 34700 MB = 64 KB = OK Participating Physical Drive(s): Ct Enc Bay WWID 2I...
... example, a logical drive is applied to the logical drive. The RAID level is set at 1, the stripe size is set at Boot Cache Configuration Status Cache Ratio = enabled = cache enabled = 25% Read / 75% Write ---------- Device File RAID Level Size Stripe Size Status = c5t0d0 = 1+0 = 34700 MB = 64 KB = OK Participating Physical Drive(s): Ct Enc Bay WWID 2I...
HP Smart Array SAS controllers for Integrity servers support guide
Page 70
...GB OK 70 Troubleshooting CONTROLLER INFORMATION Controller Product Number........... cache enabled Cache Ratio 50% Read / 50% Write Total Cache Size (MB 456 Read Cache 228 Write Cache 228 Transfer Buffer 000 Battery Pack Count 2 Battery Status...Missing Disks at Boot..... enabled SCSI Transfer Detection Mode........ DRIVER INFORMATION Driver State READY ---- yes Cache Configuration Status.......... Example 4-2 Typical sautil command output # sautil /dev/ciss3 **** **** **** SAUTIL Support Utility **** **** **** **** for the HP SmartArray RAID Controller Family ...
...GB OK 70 Troubleshooting CONTROLLER INFORMATION Controller Product Number........... cache enabled Cache Ratio 50% Read / 50% Write Total Cache Size (MB 456 Read Cache 228 Write Cache 228 Transfer Buffer 000 Battery Pack Count 2 Battery Status...Missing Disks at Boot..... enabled SCSI Transfer Detection Mode........ DRIVER INFORMATION Driver State READY ---- yes Cache Configuration Status.......... Example 4-2 Typical sautil command output # sautil /dev/ciss3 **** **** **** SAUTIL Support Utility **** **** **** **** for the HP SmartArray RAID Controller Family ...
HP Smart Array SAS controllers for Integrity servers support guide
Page 73
........... yes ---- errors (in factory M&P data)........ no Disk write cache enabled in current page....... enabled yes S.M.A.R.T. no S.M.A.R.T. supported yes S.M.A.R.T. SAS/SATA DEVICE 3I:1:3:0x5000c500014b62a1 [DISK Connector Location internal Connector 3I Enclosure 1 Bay 3 WWID 0x5000c500014b62a1 Device Type DISK Disk Capacity 73.4 GB Device Status OK Device Vendor ID HP Device Product ID DH072ABAA6 Device Serial Number 3PD0AL1Z000097420160...
........... yes ---- errors (in factory M&P data)........ no Disk write cache enabled in current page....... enabled yes S.M.A.R.T. no S.M.A.R.T. supported yes S.M.A.R.T. SAS/SATA DEVICE 3I:1:3:0x5000c500014b62a1 [DISK Connector Location internal Connector 3I Enclosure 1 Bay 3 WWID 0x5000c500014b62a1 Device Type DISK Disk Capacity 73.4 GB Device Status OK Device Vendor ID HP Device Product ID DH072ABAA6 Device Serial Number 3PD0AL1Z000097420160...
HP Smart Array SAS controllers for Integrity servers support guide
Page 74
... ID HP Device Product ID DH072ABAA6 Device Serial Number 3PD0BCSS00009742GMA1 Device Firmware Version HPD2 Reserved Area (cfg/status info 33554.4 KB (33.6 MB) Block Size (bytes/sector 512 bytes M&P Data Stamped yes Last Failure Reason none Physical Disk Flags: Disk present and operational yes Non-disk device detected no Disk write cache enabled in...
... ID HP Device Product ID DH072ABAA6 Device Serial Number 3PD0BCSS00009742GMA1 Device Firmware Version HPD2 Reserved Area (cfg/status info 33554.4 KB (33.6 MB) Block Size (bytes/sector 512 bytes M&P Data Stamped yes Last Failure Reason none Physical Disk Flags: Disk present and operational yes Non-disk device detected no Disk write cache enabled in...
HP Smart Array SAS controllers for Integrity servers support guide
Page 75
... Disk write cache enabled in current page....... no Disk write cache disabled in powerup M&P data)........ no S.M.A.R.T. Supports redundant controller operation........ errors (in factory M&P data)........ yes ---- supported yes S.M.A.R.T. SAS/SATA DEVICE 2E:1:2:0x5000c50005962a09 [DISK Connector Location external Connector 2E Enclosure 1 Bay 2 WWID 0x5000c50005962a09 Device Type DISK Disk Capacity 73.4 GB Device Status OK Device Vendor ID HP...
... Disk write cache enabled in current page....... no Disk write cache disabled in powerup M&P data)........ no S.M.A.R.T. Supports redundant controller operation........ errors (in factory M&P data)........ yes ---- supported yes S.M.A.R.T. SAS/SATA DEVICE 2E:1:2:0x5000c50005962a09 [DISK Connector Location external Connector 2E Enclosure 1 Bay 2 WWID 0x5000c50005962a09 Device Type DISK Disk Capacity 73.4 GB Device Status OK Device Vendor ID HP...
HP Smart Array SAS controllers for Integrity servers support guide
Page 77
... spin up no Disk write cache enabled in factory M&P data)........ no S.M.A.R.T. yes ---- supported yes S.M.A.R.T. errors (in powerup M&P data)........ SAS/SATA DEVICE 1E:1:1:0x5000c500052d45f9 [DISK Connector Location external Connector 1E Enclosure 1 Bay 1 WWID 0x5000c500052d45f9 Device Type DISK Disk Capacity 73.4 GB Device Status OK Device Vendor ID HP Device Product ID DH072ABAA6 Device Serial Number...
... spin up no Disk write cache enabled in factory M&P data)........ no S.M.A.R.T. yes ---- supported yes S.M.A.R.T. errors (in powerup M&P data)........ SAS/SATA DEVICE 1E:1:1:0x5000c500052d45f9 [DISK Connector Location external Connector 1E Enclosure 1 Bay 1 WWID 0x5000c500052d45f9 Device Type DISK Disk Capacity 73.4 GB Device Status OK Device Vendor ID HP Device Product ID DH072ABAA6 Device Serial Number...
HP Smart Array SAS controllers for Integrity servers support guide
Page 78
... spin up no Disk write cache enabled in factory M&P data)........ yes ---- no S.M.A.R.T. no Disk write cache enabled in factory M&P data)........ SAS/SATA DEVICE 1E:1:2:0x5000c500052d6989 [DISK Connector Location external Connector 1E Enclosure 1 Bay 2 WWID 0x5000c500052d6989 Device Type DISK Disk Capacity 73.4 GB Device Status OK Device Vendor ID HP Device Product ID DH072ABAA6 Device Serial Number 3PD0J53F00009748XRKF...
... spin up no Disk write cache enabled in factory M&P data)........ yes ---- no S.M.A.R.T. no Disk write cache enabled in factory M&P data)........ SAS/SATA DEVICE 1E:1:2:0x5000c500052d6989 [DISK Connector Location external Connector 1E Enclosure 1 Bay 2 WWID 0x5000c500052d6989 Device Type DISK Disk Capacity 73.4 GB Device Status OK Device Vendor ID HP Device Product ID DH072ABAA6 Device Serial Number 3PD0J53F00009748XRKF...
HP Smart Array SAS controllers for Integrity servers support guide
Page 79
...Enclosure 1 Bay 4 WWID 0x5000c500052d5175 Device Type DISK Disk Capacity 73.4 GB Device Status OK Device Vendor ID HP Device Product ID DH072ABAA6 Device Serial Number 3PD0H0E700009748WS5P Device Firmware Version HPD2 Reserved Area (cfg/status info 33554.4 KB... device detected no Disk write cache disabled in default page...... supported yes S.M.A.R.T. no Disk write cache enabled in a logical drive yes Configured as a spare disk no Disk write cache enabled at spin up no Supports redundant controller operation........ no S.M.A.R.T. enabled yes S.M.A.R.T. no Attached ...
...Enclosure 1 Bay 4 WWID 0x5000c500052d5175 Device Type DISK Disk Capacity 73.4 GB Device Status OK Device Vendor ID HP Device Product ID DH072ABAA6 Device Serial Number 3PD0H0E700009748WS5P Device Firmware Version HPD2 Reserved Area (cfg/status info 33554.4 KB... device detected no Disk write cache disabled in default page...... supported yes S.M.A.R.T. no Disk write cache enabled in a logical drive yes Configured as a spare disk no Disk write cache enabled at spin up no Supports redundant controller operation........ no S.M.A.R.T. enabled yes S.M.A.R.T. no Attached ...
HP Smart Array SAS controllers for Integrity servers support guide
Page 81
... Connector Location internal Connector Enclosure 0 Bay 0 WWID 0x500110a0004af23e Device Type SES Disk Capacity 0.0 GB Device Status FAILED Device Vendor ID HP Device Product ID P800 Device Serial Number P98690D9SU40R7 Device Firmware Version 1.01 Reserved Area (cfg/status info 0.0 KB (0.0 MB) Block...M&P data)........ no Non-disk device detected yes S.M.A.R.T. OK All physical disks in the logical drive are as a spare disk no Disk write cache enabled at spin up no Configured as follows: • Multiple physical disks in a fault-tolerant (RAID 1, 1+0, 5, ADG) logical drive...
... Connector Location internal Connector Enclosure 0 Bay 0 WWID 0x500110a0004af23e Device Type SES Disk Capacity 0.0 GB Device Status FAILED Device Vendor ID HP Device Product ID P800 Device Serial Number P98690D9SU40R7 Device Firmware Version 1.01 Reserved Area (cfg/status info 0.0 KB (0.0 MB) Block...M&P data)........ no Non-disk device detected yes S.M.A.R.T. OK All physical disks in the logical drive are as a spare disk no Disk write cache enabled at spin up no Configured as follows: • Multiple physical disks in a fault-tolerant (RAID 1, 1+0, 5, ADG) logical drive...
HP Smart Array SAS controllers for Integrity servers support guide
Page 89
... Array Accelerator Board Present?.... DRIVER INFORMATION Driver State READY ---- yes Cache Configuration Status.......... cache enabled Cache Ratio 50% Read / 50% Write Total Cache Size (MB 456 Battery Pack Count 2 Battery Status (pack #1 ok Battery Status (pack #2 ok ---- P800 Controller Product Name HP PCIe SmartArray P800 Hardware Path 0/6/0/0/0/0/1/0/0/0 Serial Number P98690D9SU40R7 Device File dev/ciss3 Hardware Revision D' Firmware...
... Array Accelerator Board Present?.... DRIVER INFORMATION Driver State READY ---- yes Cache Configuration Status.......... cache enabled Cache Ratio 50% Read / 50% Write Total Cache Size (MB 456 Battery Pack Count 2 Battery Status (pack #1 ok Battery Status (pack #2 ok ---- P800 Controller Product Name HP PCIe SmartArray P800 Hardware Path 0/6/0/0/0/0/1/0/0/0 Serial Number P98690D9SU40R7 Device File dev/ciss3 Hardware Revision D' Firmware...
HP Smart Array SAS controllers for Integrity servers support guide
Page 119
... updated. Critical No Array Accelerator battery backup on Self Test (POST) error codes This appendix lists the error codes that can take. Contact your HP support representative for troubleshooting. S.M.A.R.T. logical drives; (if more than 32 logical drives are configured, this otherwise will be followed by.... Reduce the number of corrective actions you can be returned by :) Informational Auto-configuration failed: Too many logical drives. Abnormal Shut-Down Detected with Write-Cache Enabled. Any data that may have been in Table C-1. Data loss may have occurred.
... updated. Critical No Array Accelerator battery backup on Self Test (POST) error codes This appendix lists the error codes that can take. Contact your HP support representative for troubleshooting. S.M.A.R.T. logical drives; (if more than 32 logical drives are configured, this otherwise will be followed by.... Reduce the number of corrective actions you can be returned by :) Informational Auto-configuration failed: Too many logical drives. Abnormal Shut-Down Detected with Write-Cache Enabled. Any data that may have been in Table C-1. Data loss may have occurred.
HP Smart Array SAS controllers for Integrity servers support guide
Page 123
... Accelerator will be replaced) Informational if Replace the cache battery, if battery bad; Data does not correspond to accept data loss and re-enable logical drives. The cache module has failed. Contact your HP service representative for assistance. 1799 Slot z Drive .... Contact your HP service representative for assistance. 1798 Slot z Drive Array - Array accelerator is temporarily disabled. Critical The cache module has failed. Warning: Pressing F2 erases all data in Array Accelerator has been lost. Array Accelerator Posted-Write Cache is temporarily (...
... Accelerator will be replaced) Informational if Replace the cache battery, if battery bad; Data does not correspond to accept data loss and re-enable logical drives. The cache module has failed. Contact your HP service representative for assistance. 1799 Slot z Drive .... Contact your HP service representative for assistance. 1798 Slot z Drive Array - Array accelerator is temporarily disabled. Critical The cache module has failed. Warning: Pressing F2 erases all data in Array Accelerator has been lost. Array Accelerator Posted-Write Cache is temporarily (...