HP ProLiant ML150 G6 Server Maintenance and Service Guide
Page 88
... VGA connector USB 2.0 ports (4) NIC connector Dedicate LO100 Management port Components, Switches, and Indicators 88 5 Components, Switches, and Indicators This chapter contains illustrations and tables identifying and describing the key components (including connectors), switches, and LED indicators located on the front and rear panels, the system board, and hard drives of the HP ProLiant ML150 G6 Server.
... VGA connector USB 2.0 ports (4) NIC connector Dedicate LO100 Management port Components, Switches, and Indicators 88 5 Components, Switches, and Indicators This chapter contains illustrations and tables identifying and describing the key components (including connectors), switches, and LED indicators located on the front and rear panels, the system board, and hard drives of the HP ProLiant ML150 G6 Server.
HP ProLiant ML150 G6 server Installation Sheet
Page 1
...36 NMI button 37 SGPIO 38 Front panel USB connector 39 Internal USB port 40 Chassis/Board ID DIP switches 41 Front panel I/O connector 42 Redundant power supply connector 43 HDD LED connector 44 Thermal sensor connector 45 TPM 46 CMOS clear jumper Table 3 Expansion...processors. Power up CD contents for this installation sheet. 1. Note the server BIOS version. Connect the keyboard, mouse, and monitor 2. To determine the BIOS version: a. If necessary, update the BIOS (refer to the HP ProLiant ML150 G6 Server Maintenance and Service Guide available on the HP website: http://www.hp.com d....
...36 NMI button 37 SGPIO 38 Front panel USB connector 39 Internal USB port 40 Chassis/Board ID DIP switches 41 Front panel I/O connector 42 Redundant power supply connector 43 HDD LED connector 44 Thermal sensor connector 45 TPM 46 CMOS clear jumper Table 3 Expansion...processors. Power up CD contents for this installation sheet. 1. Note the server BIOS version. Connect the keyboard, mouse, and monitor 2. To determine the BIOS version: a. If necessary, update the BIOS (refer to the HP ProLiant ML150 G6 Server Maintenance and Service Guide available on the HP website: http://www.hp.com d....
HP USB Floppy Drive Key Installation Instructions
Page 1
... storage solution that supports both the floppy and drive key partitions are set the device switch to the floppy drive symbol before powering up the system. To boot from the USB floppy partition of the device, set forth... in this partition. 3. The only warranties for file transfer or storage: a. Part Number 442989-001 January 2007 (First Edition) 2. HP USB Floppy Drive Key Installation Instructions Overview The USB Floppy Drive Key provides HP ProLiant server users with HP ProLiant...
... storage solution that supports both the floppy and drive key partitions are set the device switch to the floppy drive symbol before powering up the system. To boot from the USB floppy partition of the device, set forth... in this partition. 3. The only warranties for file transfer or storage: a. Part Number 442989-001 January 2007 (First Edition) 2. HP USB Floppy Drive Key Installation Instructions Overview The USB Floppy Drive Key provides HP ProLiant server users with HP ProLiant...
HP Insight Server Migration Software for ProLiant User Guide
Page 126
...the amount of the SMP Source Agent takes longer than 64 GB of HP integrated Citrix XenServer fails When using the SMP Virtual Boot CD, the...networks and the IP address is configured to the correct virtual network switch on the host. • Ensure that the virtual machine has ...is booted from the application station and source server. For more information. Power down the virtual machine. 2. Verify that the destination server and the... V2V migration, booted the virtual machine manually with the SMP Boot CD for ProLiant User Guide. 3. This error can find the SMP Source log files at ...
...the amount of the SMP Source Agent takes longer than 64 GB of HP integrated Citrix XenServer fails When using the SMP Virtual Boot CD, the...networks and the IP address is configured to the correct virtual network switch on the host. • Ensure that the virtual machine has ...is booted from the application station and source server. For more information. Power down the virtual machine. 2. Verify that the destination server and the... V2V migration, booted the virtual machine manually with the SMP Boot CD for ProLiant User Guide. 3. This error can find the SMP Source log files at ...
HP ProLiant Intel-based 100-series G6 server technology
Page 19
... to manage nodes (such as servers, workstations, routers, switches, and hubs) on an IP network. based management tool. If any other ProLiant servers. Administrators can be familiar with HP SIM and Insight Management Agents. Implementing BitLocker requires the following...Data Center Management Interface (DCMI) 1.0 Standards • HP ProLiant Onboard Administrator Powered by receiving traps or change notices from network devices implementing SNMP. Server management and deployment ProLiant ML and DL 100-series G6 server users each have been available with previous generations ...
... to manage nodes (such as servers, workstations, routers, switches, and hubs) on an IP network. based management tool. If any other ProLiant servers. Administrators can be familiar with HP SIM and Insight Management Agents. Implementing BitLocker requires the following...Data Center Management Interface (DCMI) 1.0 Standards • HP ProLiant Onboard Administrator Powered by receiving traps or change notices from network devices implementing SNMP. Server management and deployment ProLiant ML and DL 100-series G6 server users each have been available with previous generations ...
ISS Technology Update Index
Page 3
... 8 Publication date October 2009 November 2009 September 2008 Optimizing memory performance in ProLiant G6 Intel- 2 based servers Overview of Microsoft® Windows® Essential Server 7 Solutions P Performance, throughput and compatibility of HP 6 Gb/s 6 SAS drives PUE and DCE-useful metrics for overall data...using Fabric Manager software to 6 configure switches R Recommendations for differences in ProLiant 4 300 series G5 and G6 servers Quick tip: Efficient deployments-Sun Solaris 10 for 5 x86/x64 Systems Quick tips for powering off/on - demand" technology Quick ...
... 8 Publication date October 2009 November 2009 September 2008 Optimizing memory performance in ProLiant G6 Intel- 2 based servers Overview of Microsoft® Windows® Essential Server 7 Solutions P Performance, throughput and compatibility of HP 6 Gb/s 6 SAS drives PUE and DCE-useful metrics for overall data...using Fabric Manager software to 6 configure switches R Recommendations for differences in ProLiant 4 300 series G5 and G6 servers Quick tip: Efficient deployments-Sun Solaris 10 for 5 x86/x64 Systems Quick tips for powering off/on - demand" technology Quick ...
ISS Technology Update Index
Page 4
... and AMD Opteron are trademarks of Microsoft Corporation. Oracle is subject to use Brocade SAN switches or Virtual Connect- 1 Fibre Channel modules Volume 7, Number 5 Publication date June 2009 April...transition from Megahertz to Gigatransfers 6 Volume 8, Number 4 Three--phase power distribution in c7000 Enclosures 3 Volume 8, Number 3 U Unbuffered DDR-3 DIMMs are a cost-effective solution for 5 ProLiant G6 servers Volume 8, Number 4 Understanding and implementing Accelerated iSCSI on 3 HP ProLiant servers Volume 8, Number 5 Understanding and interpreting the SPECpower_ssj2008 2 ...
... and AMD Opteron are trademarks of Microsoft Corporation. Oracle is subject to use Brocade SAN switches or Virtual Connect- 1 Fibre Channel modules Volume 7, Number 5 Publication date June 2009 April...transition from Megahertz to Gigatransfers 6 Volume 8, Number 4 Three--phase power distribution in c7000 Enclosures 3 Volume 8, Number 3 U Unbuffered DDR-3 DIMMs are a cost-effective solution for 5 ProLiant G6 servers Volume 8, Number 4 Understanding and implementing Accelerated iSCSI on 3 HP ProLiant servers Volume 8, Number 5 Understanding and interpreting the SPECpower_ssj2008 2 ...
ISS Technology Update, Volume 7, Number 8
Page 2
...experience increased leakage current-current that customers begin to migrate from legacy applications to benefit from the higher performance and increased power efficiency. HP ProLiant servers include a range of cores. Historically, the hunger for tomorrow (see "Optimizing the performance of processor cores ...out of its customers with fewer cores. With traditional single-core CPUs, improved performance is driving processor vendors to switch on and off at higher frequencies. This fact combined with frequency (left ) because within a particular transistor geometry generation, ...
...experience increased leakage current-current that customers begin to migrate from legacy applications to benefit from the higher performance and increased power efficiency. HP ProLiant servers include a range of cores. Historically, the hunger for tomorrow (see "Optimizing the performance of processor cores ...out of its customers with fewer cores. With traditional single-core CPUs, improved performance is driving processor vendors to switch on and off at higher frequencies. This fact combined with frequency (left ) because within a particular transistor geometry generation, ...
Optimizing facility operation in high density data center environments
Page 7
... a single core. Measuring the power consumption of a ProLiant DL380 G4 server demonstrates the higher efficiencies of sensors within enclosures and racks, on servers and blades, and on any critical switch provides the capability to maintain system performance at higher application loads and providing power savings at their servers. The HP Dynamic Power Saver is a performance increase...
... a single core. Measuring the power consumption of a ProLiant DL380 G4 server demonstrates the higher efficiencies of sensors within enclosures and racks, on servers and blades, and on any critical switch provides the capability to maintain system performance at higher application loads and providing power savings at their servers. The HP Dynamic Power Saver is a performance increase...
Optimizing facility operation in high density data center environments
Page 10
... about HP examples of both UPS and PDU hardware and management tools, see the technology brief titled "Critical factors in intra-rack power distribution ... air discharged by using sizers from the path of least resistance. ProLiant server power supplies operate at a lower efficiency and to be used as a...switch-mode power supplies, when compared to -back cooling. This can be open to monitor and manage power environments through the front of the cabinet. Rack based power distribution The ability to monitor and manage power distribution units (PDU) is designed for uninterruptible power...
... about HP examples of both UPS and PDU hardware and management tools, see the technology brief titled "Critical factors in intra-rack power distribution ... air discharged by using sizers from the path of least resistance. ProLiant server power supplies operate at a lower efficiency and to be used as a...switch-mode power supplies, when compared to -back cooling. This can be open to monitor and manage power environments through the front of the cabinet. Rack based power distribution The ability to monitor and manage power distribution units (PDU) is designed for uninterruptible power...
Performing an HP ProLiant server NMI crash dump
Page 2
...analysis that may be used during normal operation. 2 NMI Crash Dump issue resolution events The NMI Crash Dump jumper pins or switch can provide critical information for crash dump files to be used to obtain through the Integrated Lights-Out Virtual NMI feature. ... crash dump log. Abstract This document provides a description of the HP ProLiant server implementation of the NMI Crash Dump jumper pins or switch. Both user-initiated and automatic crash dump support is a diagnostic mechanism. power cycle the system). This is an essential part of diagnosing reliability problems...
...analysis that may be used during normal operation. 2 NMI Crash Dump issue resolution events The NMI Crash Dump jumper pins or switch can provide critical information for crash dump files to be used to obtain through the Integrated Lights-Out Virtual NMI feature. ... crash dump log. Abstract This document provides a description of the HP ProLiant server implementation of the NMI Crash Dump jumper pins or switch. Both user-initiated and automatic crash dump support is a diagnostic mechanism. power cycle the system). This is an essential part of diagnosing reliability problems...
ProLiant High Availability: The IT Imperative
Page 2
...viruses by using advanced power-management techniques. INP resides at server nodes and enables the server to the first switch connection. high availability, power savings and higher performance... such as an interface between the intermediate switch and the core network has failed. ProLiant Essentials Intelligent Networking Pack The ProLiant Essentials Intelligent Networking Pack (INP) enhances ... and fiber optic interfaces, as well as your business grows. 2a HP and Intel are developing sophisticated technologies like redundant Ethernet connections, network adapter teaming,...
...viruses by using advanced power-management techniques. INP resides at server nodes and enables the server to the first switch connection. high availability, power savings and higher performance... such as an interface between the intermediate switch and the core network has failed. ProLiant Essentials Intelligent Networking Pack The ProLiant Essentials Intelligent Networking Pack (INP) enhances ... and fiber optic interfaces, as well as your business grows. 2a HP and Intel are developing sophisticated technologies like redundant Ethernet connections, network adapter teaming,...
ProLiant High Availability: The IT Imperative
Page 3
...read only from the entire bank that occurs within the data center as well as the console, keyboard, mouse and power. The failed bank is deactivated, but data is integrated with other basic team types such as a single connection to...switch NIC 1 primary SWITCH A ▼ Gigabit Ethernet 100 Mbps ▼ secondary NIC 2 SWITCH B HP ProLiant server CORE SWITCH slower cross-link RECOVERY: team's new primary NIC has gigabit path to core switch NIC 1 new primary new secondary NIC 2 SWITCH A ▼ Gigabit Ethernet 100 Mbps ▼ SWITCH B HP ProLiant server CORE SWITCH...
...read only from the entire bank that occurs within the data center as well as the console, keyboard, mouse and power. The failed bank is deactivated, but data is integrated with other basic team types such as a single connection to...switch NIC 1 primary SWITCH A ▼ Gigabit Ethernet 100 Mbps ▼ secondary NIC 2 SWITCH B HP ProLiant server CORE SWITCH slower cross-link RECOVERY: team's new primary NIC has gigabit path to core switch NIC 1 new primary new secondary NIC 2 SWITCH A ▼ Gigabit Ethernet 100 Mbps ▼ SWITCH B HP ProLiant server CORE SWITCH...