Microsoft Windows Event ID and SNMP Traps Reference Guide for use with SmartStart version 8.25
Page 9
... instances of those objects contained within the variable list are those of the alarm entry that generated this trap. The data contains the error code. Specific error information is contained in CPQHOST.MIB Symptom: Generic trap. Event identifier: cpqhsmsg.dll - 774 (Hex)0xc4350306 (Service Event) Log Severity: Error (3) Log Message: The...
... instances of those objects contained within the variable list are those of the alarm entry that generated this trap. The data contains the error code. Specific error information is contained in CPQHOST.MIB Symptom: Generic trap. Event identifier: cpqhsmsg.dll - 774 (Hex)0xc4350306 (Service Event) Log Severity: Error (3) Log Message: The...
HP ProLiant ML150 G6 Server Maintenance and Service Guide
Page 4
Clearing CMOS ...84 Power-On Self Test ...84 POST Error Indicators ...85 Recoverable POST Errors ...85 POST Related Troubleshooting ...87 NMI button ...87 5 Components, Switches, and Indicators 88 Front and Rear Panel Components, Switches, and Indicators 88 System Board Components, Switches, and Indicators 90 System board switches and jumpers ...92 SAS/SATA Hot-Plug Hard Drive LEDs ...93 6 Physical and Operating Specifications 94 System Unit ...94 Memory...99 Processor ...99 SATA DVD-ROM Drive...101 SAS Hard Drive ...102 SATA Hard Drive ...103 Index ...104 Contents 4
Clearing CMOS ...84 Power-On Self Test ...84 POST Error Indicators ...85 Recoverable POST Errors ...85 POST Related Troubleshooting ...87 NMI button ...87 5 Components, Switches, and Indicators 88 Front and Rear Panel Components, Switches, and Indicators 88 System Board Components, Switches, and Indicators 90 System board switches and jumpers ...92 SAS/SATA Hot-Plug Hard Drive LEDs ...93 6 Physical and Operating Specifications 94 System Unit ...94 Memory...99 Processor ...99 SATA DVD-ROM Drive...101 SAS Hard Drive ...102 SATA Hard Drive ...103 Index ...104 Contents 4
HP ProLiant ML150 G6 Server Maintenance and Service Guide
Page 24
Before installing a new component, review its specifications to the "Electrostatic Discharge Information" section for more information. Required tools You need the following tools to perform these figures are used in... the related figure (i.e., Label 1 corresponds to step a, label 2 corresponds to verify that all pertinent component information, including model and serial number, for the HP ProLiant ML150 G6 server. Be sure that the server be powered down before beginning any removal or replacement procedure, run the diagnostics program to step b, etc.). 3 Removal and...
Before installing a new component, review its specifications to the "Electrostatic Discharge Information" section for more information. Required tools You need the following tools to perform these figures are used in... the related figure (i.e., Label 1 corresponds to step a, label 2 corresponds to verify that all pertinent component information, including model and serial number, for the HP ProLiant ML150 G6 server. Be sure that the server be powered down before beginning any removal or replacement procedure, run the diagnostics program to step b, etc.). 3 Removal and...
HP ProLiant ML150 G6 Server Maintenance and Service Guide
Page 67
.... • The field value is informational only. • The field is user-configurable). Press the (+), (-) keys repeatedly to display each menu screen displays a field/item-specific help panel, and displays the help text for the currently selected field (only if it is password-protected. Parameters that are user-configurable. When pressed...
.... • The field value is informational only. • The field is user-configurable). Press the (+), (-) keys repeatedly to display each menu screen displays a field/item-specific help panel, and displays the help text for the currently selected field (only if it is password-protected. Parameters that are user-configurable. When pressed...
HP ProLiant ML150 G6 Server Maintenance and Service Guide
Page 70
... Configuration - To correct the settings, press F9 key to restore the default settings. Configure TPM settings. • USB Configuration - Configure NIC and VGA settings. The specific advanced settings that are user-configurable are accessible through the Advanced Settings submenus shown in Figures 4-5 through 4-14.
... Configuration - To correct the settings, press F9 key to restore the default settings. Configure TPM settings. • USB Configuration - Configure NIC and VGA settings. The specific advanced settings that are user-configurable are accessible through the Advanced Settings submenus shown in Figures 4-5 through 4-14.
HP ProLiant ML150 G6 Server Maintenance and Service Guide
Page 94
... for the HP ProLiant ML150 G6 server. 6 Physical and Operating Specifications This chapter provides physical and operating specifications for the following: • System unit • Software • Physical • Environmental • Power supply • Memory • Processor • Optical drive • SAS drive • SATA drive • SAS/SATA controller card System Unit Table 6-1 Hardware Specifications Item...
... for the HP ProLiant ML150 G6 server. 6 Physical and Operating Specifications This chapter provides physical and operating specifications for the following: • System unit • Software • Physical • Environmental • Power supply • Memory • Processor • Optical drive • SAS drive • SATA drive • SAS/SATA controller card System Unit Table 6-1 Hardware Specifications Item...
HP ProLiant ML150 G6 Server Maintenance and Service Guide
Page 95
Table 6-1 Hardware Specifications Item Optional media storage I/O ports Status LED indicators Power Supply unit (PSU) Thermal solution Component • Two half-height drive bays for additional SATA optical ... , two front system fan and one redundant front system fans) • Processor heat sink • Power supply fan (one per power supply) Physical and Operating Specifications 95 plug SATA/SAS hard drive PS2 keyboard port, PS2 mouse port, USB 2.0 ports (two front-mounted ports, four rear-mounted ports and two internal...
Table 6-1 Hardware Specifications Item Optional media storage I/O ports Status LED indicators Power Supply unit (PSU) Thermal solution Component • Two half-height drive bays for additional SATA optical ... , two front system fan and one redundant front system fans) • Processor heat sink • Power supply fan (one per power supply) Physical and Operating Specifications 95 plug SATA/SAS hard drive PS2 keyboard port, PS2 mouse port, USB 2.0 ports (two front-mounted ports, four rear-mounted ports and two internal...
HP ProLiant ML150 G6 Server Maintenance and Service Guide
Page 96
Table 6-2 Software Specifications Item Description Network operating system (NOS) • support • • • Microsoft Windows 2003 R2 Standard (X86/X64) Microsoft Windows 2003 R2 Enterprise (X86/X64) .../X64) SuSE Linux Enterprise Server 10 Edition (X86/X64) SuSE Linux Enterprise Server 11 Edition (X86/X64) System diagnostics • AMI BIOS Setup Utility • HP Insight Diagnostics Physical and Operating Specifications 96
Table 6-2 Software Specifications Item Description Network operating system (NOS) • support • • • Microsoft Windows 2003 R2 Standard (X86/X64) Microsoft Windows 2003 R2 Enterprise (X86/X64) .../X64) SuSE Linux Enterprise Server 10 Edition (X86/X64) SuSE Linux Enterprise Server 11 Edition (X86/X64) System diagnostics • AMI BIOS Setup Utility • HP Insight Diagnostics Physical and Operating Specifications 96
HP ProLiant ML150 G6 Server Maintenance and Service Guide
Page 97
... keyboard and monitor Description EATX (Extended Advanced Technology) 12 in . (424 mm x 200 mm x 616.86 mm) 40.89 lb. (18.55 kg) Table 6-4 Environmental Specifications Parameter Temperature: Operating Non-operating Storage Wet-bulb temperature Relative humidity: Operating Non-operating Storage Altitude: Operating Non-operating Description +50 to +95° F (+10... % (non-condensing) 10 % to 95 % 10 % to 95 % 0 to 10,000 ft (0 to 3000 meters) 0 to 30,000 ft (0 to 9144 meters) Physical and Operating Specifications 97 x 24.33 in .
... keyboard and monitor Description EATX (Extended Advanced Technology) 12 in . (424 mm x 200 mm x 616.86 mm) 40.89 lb. (18.55 kg) Table 6-4 Environmental Specifications Parameter Temperature: Operating Non-operating Storage Wet-bulb temperature Relative humidity: Operating Non-operating Storage Altitude: Operating Non-operating Description +50 to +95° F (+10... % (non-condensing) 10 % to 95 % 10 % to 95 % 0 to 10,000 ft (0 to 3000 meters) 0 to 30,000 ft (0 to 9144 meters) Physical and Operating Specifications 97 x 24.33 in .
HP ProLiant ML150 G6 Server Maintenance and Service Guide
Page 98
... 95 % (non-condensing at +40° C) 90 % (for a period of 24 hours at 65° C ambient) Table 6-6 Power Supply Specifications (750W) Parameter Dimensions (H x W x D) Weight (approximate) Voltage Current: +12V +12Vaux Power supply output power: Steady state power in watts Maximum peak...Description 1.515 in . x 5.91 in . Max: 62.5A Max: 2.5A 750 Watts 750 Watts Physical and Operating Specifications 98 x 3.4 in . Table 6-5 Power Supply Specifications (460W) Parameter Dimensions (H x W x D) Weight (approximate) Input requirements : Rated input voltage Normal line voltage Line frequency...
... 95 % (non-condensing at +40° C) 90 % (for a period of 24 hours at 65° C ambient) Table 6-6 Power Supply Specifications (750W) Parameter Dimensions (H x W x D) Weight (approximate) Voltage Current: +12V +12Vaux Power supply output power: Steady state power in watts Maximum peak...Description 1.515 in . x 5.91 in . Max: 62.5A Max: 2.5A 750 Watts 750 Watts Physical and Operating Specifications 98 x 3.4 in . Table 6-5 Power Supply Specifications (460W) Parameter Dimensions (H x W x D) Weight (approximate) Input requirements : Rated input voltage Normal line voltage Line frequency...
HP ProLiant ML150 G6 Server Maintenance and Service Guide
Page 99
...: Two-processor (2P) systems must be configured with ECC Processor The HP ProLiant ML150 G6 server provides two Intel LGA1366 processor sockets that support Intel Nehalem Dual-Core E5502 and Intel Nehalem Quad-Core E5504/E5506/E5520/E5530/E5540 processors. Table 6-6 Power Supply Specifications (750W) Parameter Temperature range: Operating Shipping Relative humidity: Operating Non-operating...
...: Two-processor (2P) systems must be configured with ECC Processor The HP ProLiant ML150 G6 server provides two Intel LGA1366 processor sockets that support Intel Nehalem Dual-Core E5502 and Intel Nehalem Quad-Core E5504/E5506/E5520/E5530/E5540 processors. Table 6-6 Power Supply Specifications (750W) Parameter Temperature range: Operating Shipping Relative humidity: Operating Non-operating...
HP ProLiant ML150 G6 Server Maintenance and Service Guide
Page 100
Table 6-9 Intel Xeon Quad-Core E5504/E5506/E5520/E5530/E5540 processors specifications Model Number E5504 E5506 E5520 E5530 E5540 Operating Frequency 2.0 GHz 2.13 GHz 2.26 GHz 2.40 GHz 2.53 GHz QPI 4.8GT/s 4.8GT/s 5.86GT/s 5.86GT/s 5.86GT/s On-die L2 cache 4 MB 4 MB 8 MB 8 MB 8 MB Thermal Design Point (power) 80 watts 80 watts 80 watts 80 watts 80 watts Physical and Operating Specifications 100
Table 6-9 Intel Xeon Quad-Core E5504/E5506/E5520/E5530/E5540 processors specifications Model Number E5504 E5506 E5520 E5530 E5540 Operating Frequency 2.0 GHz 2.13 GHz 2.26 GHz 2.40 GHz 2.53 GHz QPI 4.8GT/s 4.8GT/s 5.86GT/s 5.86GT/s 5.86GT/s On-die L2 cache 4 MB 4 MB 8 MB 8 MB 8 MB Thermal Design Point (power) 80 watts 80 watts 80 watts 80 watts 80 watts Physical and Operating Specifications 100
HP ProLiant ML150 G6 Server Maintenance and Service Guide
Page 101
SATA DVD-ROM Drive Table 6-10 SATA DVD-ROM Specifications Parameter Form factor Dimensions: Height Width Depth Weight Supported disc formats Read speeds Disc capacity Average access time: Typical random Full stroke Three-way eject ...
SATA DVD-ROM Drive Table 6-10 SATA DVD-ROM Specifications Parameter Form factor Dimensions: Height Width Depth Weight Supported disc formats Read speeds Disc capacity Average access time: Typical random Full stroke Three-way eject ...
HP ProLiant ML150 G6 Server Maintenance and Service Guide
Page 102
SAS Hard Drive Table 6-11 SAS Hard drive specifications Parameter Capacity Height Width Interface Transfer Rate Rotational Speed Bytes per sector Operating Temperature 72-GB Drive 146-GB Drive 72 GB ... RPM 15,000 RPM 512 512 5°C to 60°C 5°C to 60°C Table 6-12 Dual Port SAS Hard drive specifications Parameter 146-GB Drive 300-GB Drive 400-GB drive 450-GB Drive 750-GB Drive 1-TB Drive Capacity 146 GB 300 GB 400GB ...to 60°C 5°C to 60°C 5°C to 60°C 5°C to 60°C 5°C to 60°C Physical and Operating Specifications 102
SAS Hard Drive Table 6-11 SAS Hard drive specifications Parameter Capacity Height Width Interface Transfer Rate Rotational Speed Bytes per sector Operating Temperature 72-GB Drive 146-GB Drive 72 GB ... RPM 15,000 RPM 512 512 5°C to 60°C 5°C to 60°C Table 6-12 Dual Port SAS Hard drive specifications Parameter 146-GB Drive 300-GB Drive 400-GB drive 450-GB Drive 750-GB Drive 1-TB Drive Capacity 146 GB 300 GB 400GB ...to 60°C 5°C to 60°C 5°C to 60°C 5°C to 60°C 5°C to 60°C Physical and Operating Specifications 102
HP ProLiant ML150 G6 Server Maintenance and Service Guide
Page 103
SATA Hard Drive Table 6-13 SATA Hard Drive Specifications Item Capacity Dimensions: Height Width Depth Weight Interface Maximum transfer rate Rotational speed Byte per sector Sectors per sector 512 Max. Block Number 1,465,149,... in) 101.6 mm (4.0 in) 147.0 mm (5.8 in) 0.63 kg (1.4 Ib) SATA 150 Gbps 16MB Buffer 3.0 Gb/s 7200 RPM n/a n/a 0°C to 55°C Physical and Operating Specifications 103
SATA Hard Drive Table 6-13 SATA Hard Drive Specifications Item Capacity Dimensions: Height Width Depth Weight Interface Maximum transfer rate Rotational speed Byte per sector Sectors per sector 512 Max. Block Number 1,465,149,... in) 101.6 mm (4.0 in) 147.0 mm (5.8 in) 0.63 kg (1.4 Ib) SATA 150 Gbps 16MB Buffer 3.0 Gb/s 7200 RPM n/a n/a 0°C to 55°C Physical and Operating Specifications 103
HP ProLiant ML150 G6 Server Maintenance and Service Guide
Page 105
... 48, 49 socket location, 42 Processor, 99 PSU replacement warnings, 61 replacing, 61 R Rear system fan, 32 S SAS Hard Drive specifications, 102 SATA Hard Drive specifications, 103 Setup Utility menu bar advanced menu, 70 boot menu, 80 exit menu, 82 security menu, 81 standby mode effects, 27 symbols...HDD cage backplane, 40 hot-plug, 40 non-hot-plug, 40 HDD cage, 40 hot surface warning, 27 I /O subsystem, 94 hazardous conditions. Hardware Specifications, 94 chipset, 94 default media storage, 94 Hardware monitoring device, 94 I IDE CD-ROM Drive, 101 L labels. See symbols on equipment, 25 system...
... 48, 49 socket location, 42 Processor, 99 PSU replacement warnings, 61 replacing, 61 R Rear system fan, 32 S SAS Hard Drive specifications, 102 SATA Hard Drive specifications, 103 Setup Utility menu bar advanced menu, 70 boot menu, 80 exit menu, 82 security menu, 81 standby mode effects, 27 symbols...HDD cage backplane, 40 hot-plug, 40 non-hot-plug, 40 HDD cage, 40 hot surface warning, 27 I /O subsystem, 94 hazardous conditions. Hardware Specifications, 94 chipset, 94 default media storage, 94 Hardware monitoring device, 94 I IDE CD-ROM Drive, 101 L labels. See symbols on equipment, 25 system...
HP ProLiant ML150 G6 Server Maintenance and Service Guide
Page 106
system board components (location), 90 system board components (replaceable), 42 system board components, switches, 92 system covers access panel, 28 front bezel, 29 system fan replacing, 57 System Unit specifications, 94 T thermal grease caution, 45 U uninterruptible power supply. See UPS UPS, 27 W warnings battery replacement, 53 component-level repairs, 24 hot surface, 27 improper repairs, 24 personal injury, 27 PSU replacement, 61 technician notes, 24 warranty, 5 work area recommendations, 25 Index 106
system board components (location), 90 system board components (replaceable), 42 system board components, switches, 92 system covers access panel, 28 front bezel, 29 system fan replacing, 57 System Unit specifications, 94 T thermal grease caution, 45 U uninterruptible power supply. See UPS UPS, 27 W warnings battery replacement, 53 component-level repairs, 24 hot surface, 27 improper repairs, 24 personal injury, 27 PSU replacement, 61 technician notes, 24 warranty, 5 work area recommendations, 25 Index 106
DIMM Installation Instructions
Page 1
... computer before removing them inward to the risk of memory while the computer is equipped with this feature, see the computer-specific user documentation. The installation is subject to halt during or after the memory installation process, see the documentation supplied with all... For additional information about HP products, see the computer product documentation. For more information, see the HP website (http://www.hp.com/support). To reduce the risk of personal injury, allow the DIMMs to access the DIMM slots. 6. See the computer-specific documentation. Do not force...
... computer before removing them inward to the risk of memory while the computer is equipped with this feature, see the computer-specific user documentation. The installation is subject to halt during or after the memory installation process, see the documentation supplied with all... For additional information about HP products, see the computer product documentation. For more information, see the HP website (http://www.hp.com/support). To reduce the risk of personal injury, allow the DIMMs to access the DIMM slots. 6. See the computer-specific documentation. Do not force...
ProLiant Essentials Foundation Pack Installation Guide
Page 1
... in its management software. After installing the OS, insert the SmartStart CD and install the operating system-specific PSP onto the server. HP shall not be launched by SmartStart. • Be sure that the operating system CD and product identification...infrastructure and management capabilities with RBSU. Be sure that simplifies server setup and provides consistent server configurations. • ProLiant Support Pack (PSP) - HP ProLiant Essentials Foundation Pack Installation Guide © Copyright 2002, 2008 Hewlett-Packard Development Company, L.P. The information contained herein...
... in its management software. After installing the OS, insert the SmartStart CD and install the operating system-specific PSP onto the server. HP shall not be launched by SmartStart. • Be sure that the operating system CD and product identification...infrastructure and management capabilities with RBSU. Be sure that simplifies server setup and provides consistent server configurations. • ProLiant Support Pack (PSP) - HP ProLiant Essentials Foundation Pack Installation Guide © Copyright 2002, 2008 Hewlett-Packard Development Company, L.P. The information contained herein...
HP BladeSystem Management Pack version 1.0 for Microsoft System Center Essentials Troubleshooting Assistant
Page 8
... the Monitor Manager is not updated automatically (on page 9) • A critical state displays in the Monitor Manager for the monitor service (on page 12) Troubleshooting 8 HP Management Packs are sealed and protected from any modification, so the custom task is stored in the details pane (on page 10) • Downgrade of... (on page 12) • State icon or alert state appears gray (on page 9) • A critical state displays in the Monitor Manager for custom information management specific to HP Management Packs will ease future upgrades and migration paths.
... the Monitor Manager is not updated automatically (on page 9) • A critical state displays in the Monitor Manager for the monitor service (on page 12) Troubleshooting 8 HP Management Packs are sealed and protected from any modification, so the custom task is stored in the details pane (on page 10) • Downgrade of... (on page 12) • State icon or alert state appears gray (on page 9) • A critical state displays in the Monitor Manager for custom information management specific to HP Management Packs will ease future upgrades and migration paths.