6 Physical and Operating Specifications This chapter provides physical and operating specifications for the following: • System unit • Software • Physical • Environmental • Power supply • Memory • Processor • Optical drive • SAS drive • SATA drive • SAS/SATA controller card System Unit Table 6-1 Hardware Specifications Item Processor ...-hot-plug or hot-plug HDD cage supporting up to four SATA/SAS hard drives Physical and Operating Specifications 94 Specifications are provided for the HP ProLiant ML150 G6 server.
6 Physical and Operating Specifications This chapter provides physical and operating specifications for the following: • System unit • Software • Physical • Environmental • Power supply • Memory • Processor • Optical drive • SAS drive • SATA drive • SAS/SATA controller card System Unit Table 6-1 Hardware Specifications Item Processor ...-hot-plug or hot-plug HDD cage supporting up to four SATA/SAS hard drives Physical and Operating Specifications 94 Specifications are provided for the HP ProLiant ML150 G6 server.
HP ProLiant ML150 G6 Server Maintenance and Service Guide
Page 99
Table 6-6 Power Supply Specifications (750W) Parameter Temperature range: Operating Shipping Relative humidity: Operating Non-operating Description ...the same type. CAUTION: Two-processor (2P) systems must be configured with ECC Processor The HP ProLiant ML150 G6 server provides two Intel LGA1366 processor sockets that support Intel Nehalem Dual-Core E5502 and Intel Nehalem...E5502 Operating Frequency 1.86 GHz QPI 4.8GT/s On-die L2 cache 4 MB Thermal Design Point (power) 80 watts Physical and Operating Specifications 99 Registered DDR3 1066/1333 DIMM with ECC and un-buffered...
Table 6-6 Power Supply Specifications (750W) Parameter Temperature range: Operating Shipping Relative humidity: Operating Non-operating Description ...the same type. CAUTION: Two-processor (2P) systems must be configured with ECC Processor The HP ProLiant ML150 G6 server provides two Intel LGA1366 processor sockets that support Intel Nehalem Dual-Core E5502 and Intel Nehalem...E5502 Operating Frequency 1.86 GHz QPI 4.8GT/s On-die L2 cache 4 MB Thermal Design Point (power) 80 watts Physical and Operating Specifications 99 Registered DDR3 1066/1333 DIMM with ECC and un-buffered...
5U Tower G6 Server Hard Disk Drive Cage option Installation Instructions
Page 1
... refer to the documentation referenced on the system. Before using the HDD cage, make sure a 750 w redundant power supply is installed on the HP Server product CD. If necessary, press the power button to the 4-pin connectors on a none-hot-plug system b. Remove the front panel bezel. 7. Lift ... to power down the operating system (OS) in the express warranty statements accompanying such products and services. Press the top tab toward the rear, lift the assembly up slightly and it rotate away from the chassis. 5U Tower G6 Server Hard Disk Drive Cage option Installation ...
... refer to the documentation referenced on the system. Before using the HDD cage, make sure a 750 w redundant power supply is installed on the HP Server product CD. If necessary, press the power button to the 4-pin connectors on a none-hot-plug system b. Remove the front panel bezel. 7. Lift ... to power down the operating system (OS) in the express warranty statements accompanying such products and services. Press the top tab toward the rear, lift the assembly up slightly and it rotate away from the chassis. 5U Tower G6 Server Hard Disk Drive Cage option Installation ...
5U Tower G6 Server Redundant Power Supply Enablement Option Installation Instructions
Page 1
... solution. 15. Tilt the power supply toward the front of the existing power supply from the system chassis. 5. 5U Tower G6 Server Redundant Power Supply Enablement Option Installation Instructions Overview This document contains instructions for installing the optional Redundant Power Supply (RPS) enablement kit into... For more information on preparing the server for installation, refer to the document titled Important Safety Information on the HP server product CD. Remove the air baffle by qualified personnel who are knowledgeable of the chassis. Reinstall the six...
... solution. 15. Tilt the power supply toward the front of the existing power supply from the system chassis. 5. 5U Tower G6 Server Redundant Power Supply Enablement Option Installation Instructions Overview This document contains instructions for installing the optional Redundant Power Supply (RPS) enablement kit into... For more information on preparing the server for installation, refer to the document titled Important Safety Information on the HP server product CD. Remove the air baffle by qualified personnel who are knowledgeable of the chassis. Reinstall the six...
HP ProLiant ML 150 G6 Processor Installation Card
Page 1
...baffle from the chassis and lift the air baffle away from retention tab. 10. HP shall not be reinstalled on the Easy set-up CD . Part number 530773-001 March 2009 (First Edition) Item Description 1 Power supply unit 2 Processor 1 3 Processor 2 4 System board 5 Air baffle Figure ...notices © Copyright 2009 Hewlett-Packard Development Company, L.P. Disconnect the power cord from CPU socket 12. Remove cover from the system chassis. 5. For more information on the HP ProLiant ML150 G6 Server Easy set forth in contact with equipment containing hazardous energy circuits....
...baffle from the chassis and lift the air baffle away from retention tab. 10. HP shall not be reinstalled on the Easy set-up CD . Part number 530773-001 March 2009 (First Edition) Item Description 1 Power supply unit 2 Processor 1 3 Processor 2 4 System board 5 Air baffle Figure ...notices © Copyright 2009 Hewlett-Packard Development Company, L.P. Disconnect the power cord from CPU socket 12. Remove cover from the system chassis. 5. For more information on the HP ProLiant ML150 G6 Server Easy set forth in contact with equipment containing hazardous energy circuits....
HP ProLiant ML150 G6 server Installation Sheet
Page 1
...disk drives, DIMMs, or processors. Power up CD contents for this installation sheet. 1. Press the Esc key at the HP logo screen, and then press the Pause key to the HP ProLiant ML150 G6 Server Maintenance and Service Guide available on the HP website: http://www.hp.com d. Note the server BIOS version... 5F 16 CPU2_DIMM slot 4B 17 CPU2_DIMM slot 3E 18 CPU2_DIMM slot 2A 19 CPU2_DIMM slot 1D 20 Processor 2 socket 21 Power supply connector (8-Pin) 22 Power Supply connector (24-pin) 23 Battery Item Description 24 Internal USB connector 25 SATA 6_ODD 2 connector 26 SATA 5_ODD 1 connector ...
...disk drives, DIMMs, or processors. Power up CD contents for this installation sheet. 1. Press the Esc key at the HP logo screen, and then press the Pause key to the HP ProLiant ML150 G6 Server Maintenance and Service Guide available on the HP website: http://www.hp.com d. Note the server BIOS version... 5F 16 CPU2_DIMM slot 4B 17 CPU2_DIMM slot 3E 18 CPU2_DIMM slot 2A 19 CPU2_DIMM slot 1D 20 Processor 2 socket 21 Power supply connector (8-Pin) 22 Power Supply connector (24-pin) 23 Battery Item Description 24 Internal USB connector 25 SATA 6_ODD 2 connector 26 SATA 5_ODD 1 connector ...
HP ProLiant ML100 Series Server User Guide
Page 37
...the TPM or the encryption technology. When requested, HP Service provides a TPM with the spare system board. • Any attempt to the server access panel. Portions of the power supply and some internal circuitry remain active until AC power is not liable for service replacement, do one...37 When installing or replacing a TPM, observe the following : o Unlock and remove the bezel ("Remove the tower bezel (ML150 G6 servers)" on page 39). For ML110 G6 servers, extend the server from the rack. 4. 2. For operating instructions, see the label attached to remove an installed TPM ...
...the TPM or the encryption technology. When requested, HP Service provides a TPM with the spare system board. • Any attempt to the server access panel. Portions of the power supply and some internal circuitry remain active until AC power is not liable for service replacement, do one...37 When installing or replacing a TPM, observe the following : o Unlock and remove the bezel ("Remove the tower bezel (ML150 G6 servers)" on page 39). For ML110 G6 servers, extend the server from the rack. 4. 2. For operating instructions, see the label attached to remove an installed TPM ...
HP ProLiant G6 Technology Overview
Page 1
... ProLiant G6 servers ...3 Intel® Xeon® processor 5500 series ...3 Intel QuickPath Technology...3 Integrated memory controller ...4 Three-level cache hierarchy...4 Intel Hyper-Threading Technology 4 Intel Turbo Boost Technology ...4 Dynamic Power Management ...4 DDR-3 memory technology ...4 Smart Array technology ...5 Smart Array controllers ...5 HP SAS Expander Card ...5 Thermal Logic technologies ...6 Dynamic Power Capping ...6 'Sea of Sensors' ...6 Common Slot Power Supplies...
... ProLiant G6 servers ...3 Intel® Xeon® processor 5500 series ...3 Intel QuickPath Technology...3 Integrated memory controller ...4 Three-level cache hierarchy...4 Intel Hyper-Threading Technology 4 Intel Turbo Boost Technology ...4 Dynamic Power Management ...4 DDR-3 memory technology ...4 Smart Array technology ...5 Smart Array controllers ...5 HP SAS Expander Card ...5 Thermal Logic technologies ...6 Dynamic Power Capping ...6 'Sea of Sensors' ...6 Common Slot Power Supplies...
HP ProLiant G6 Technology Overview
Page 2
... the internal environment of Sensors', and common power slots. The common power slots allow them to 50%. Originally limited to the HP BladeSystem, Thermal Logic technology is now implemented across the ProLiant G6 server portfolio and includes Dynamic Power Capping, a 'Sea of each server to right-size the power supply for individual servers from any location. Maximize energy...
... the internal environment of Sensors', and common power slots. The common power slots allow them to 50%. Originally limited to the HP BladeSystem, Thermal Logic technology is now implemented across the ProLiant G6 server portfolio and includes Dynamic Power Capping, a 'Sea of each server to right-size the power supply for individual servers from any location. Maximize energy...
HP ProLiant G6 Technology Overview
Page 6
... overload. 6 For example, the sensors can save power by other server components. Common Slot Power Supplies Many ProLiant G6 servers have a specified trip time of servers in place until an administrator changes them through the HP iLO Advanced or IPM interfaces. Dynamic Power Capping takes advantage of spares and 1 Dynamic Power Capping has been designed and tested to...
... overload. 6 For example, the sensors can save power by other server components. Common Slot Power Supplies Many ProLiant G6 servers have a specified trip time of servers in place until an administrator changes them through the HP iLO Advanced or IPM interfaces. Dynamic Power Capping takes advantage of spares and 1 Dynamic Power Capping has been designed and tested to...
HP ProLiant G6 Technology Overview
Page 7
... management, flexible deployment, virtual machine management, and power management. On ProLiant 300 series G6 servers and ProLiant G6 server blades, Onboard Administrator Powered by iLO works hand-in selecting the right power supply for discovery, imaging and provisioning, deployment, firmware updates, monitoring, remote access, virtualization, and general lifecycle management. Onboard Administrator HP Onboard Administrator, which is accessible through a web...
... management, flexible deployment, virtual machine management, and power management. On ProLiant 300 series G6 servers and ProLiant G6 server blades, Onboard Administrator Powered by iLO works hand-in selecting the right power supply for discovery, imaging and provisioning, deployment, firmware updates, monitoring, remote access, virtualization, and general lifecycle management. Onboard Administrator HP Onboard Administrator, which is accessible through a web...
HP ProLiant Intel-based 100-series G6 server technology
Page 1
HP ProLiant 100-series Intel-based G6 server technology Technology brief, 3rd edition Abstract...3 Introduction...3 Intel Xeon 5500 Series processor technology 3 Multi-level caches ...4 QuickPath Interconnect controller ...4 Hyper ... SAS-2 standard ...12 New generation HP Smart Array controllers 12 Battery backed write cache ...13 Zero Memory RAID...13 Software RAID ...13 Smart Array Advanced Pack ...13 Networking technologies ...14 Power and thermal technologies ...14 Efficient power delivery...14 Common Slot power supplies...15 Redundant power operation ...16 Voltage regulation ...16 ...
HP ProLiant 100-series Intel-based G6 server technology Technology brief, 3rd edition Abstract...3 Introduction...3 Intel Xeon 5500 Series processor technology 3 Multi-level caches ...4 QuickPath Interconnect controller ...4 Hyper ... SAS-2 standard ...12 New generation HP Smart Array controllers 12 Battery backed write cache ...13 Zero Memory RAID...13 Software RAID ...13 Smart Array Advanced Pack ...13 Networking technologies ...14 Power and thermal technologies ...14 Efficient power delivery...14 Common Slot power supplies...15 Redundant power operation ...16 Voltage regulation ...16 ...
HP ProLiant Intel-based 100-series G6 server technology
Page 3
...utility that can reduce power and thermal use by increased performance, better power efficiency, and more information" section at the end of this writing, the Intel-based 100-series G6 servers include the ProLiant DL120, DL160, DL180, ML110, ML150, DL170h, DL2x170h, ...among individual ProLiant 100-series G6 platforms. For complete specifications of all Intel-based ProLiant 100-series G6 servers. Characterized by power supplies, I/O, processors, and memory The technologies discussed in Intel-based HP ProLiant 100-series G6 servers. The 100-series family includes the ProLiant DL100-series...
...utility that can reduce power and thermal use by increased performance, better power efficiency, and more information" section at the end of this writing, the Intel-based 100-series G6 servers include the ProLiant DL120, DL160, DL180, ML110, ML150, DL170h, DL2x170h, ...among individual ProLiant 100-series G6 platforms. For complete specifications of all Intel-based ProLiant 100-series G6 servers. Characterized by power supplies, I/O, processors, and memory The technologies discussed in Intel-based HP ProLiant 100-series G6 servers. The 100-series family includes the ProLiant DL100-series...
HP ProLiant Intel-based 100-series G6 server technology
Page 14
...; Mirror Splitting and Recombining in ProLiant 100-series G6 servers. NOTE: At a minimum, a 256 MB cache and battery kit is not available on this and other HP network adapter products, go to www.hp.com/go /SAAP. Networking technologies The NC522SFP is available at www.hp.com/go /ProLiantNICs. Efficient power delivery Power supplies for data. • Advanced...
...; Mirror Splitting and Recombining in ProLiant 100-series G6 servers. NOTE: At a minimum, a 256 MB cache and battery kit is not available on this and other HP network adapter products, go to www.hp.com/go /SAAP. Networking technologies The NC522SFP is available at www.hp.com/go /ProLiantNICs. Efficient power delivery Power supplies for data. • Advanced...
HP ProLiant Intel-based 100-series G6 server technology
Page 15
... highly efficient power supplies and DC power regulators to deliver significantly higher power efficiencies. The 1200W power supplies (AC and 48VDC) meet Climate Savers Gold requirements. With the exception of spares the customer must keep in ProLiant G6 servers. Common Slot power supplies The HP G6 Common Slot power strategy provides power supply commonality across supported ProLiant G6 server lines. All ProLiant 100-series G6 servers use HP industry standard5 power supplies.
... highly efficient power supplies and DC power regulators to deliver significantly higher power efficiencies. The 1200W power supplies (AC and 48VDC) meet Climate Savers Gold requirements. With the exception of spares the customer must keep in ProLiant G6 servers. Common Slot power supplies The HP G6 Common Slot power strategy provides power supply commonality across supported ProLiant G6 server lines. All ProLiant 100-series G6 servers use HP industry standard5 power supplies.
HP ProLiant Intel-based 100-series G6 server technology
Page 16
... of DIMMs installed. Voltage regulation Voltage regulators convert the 12V DC supplied from both power supplies. HP has developed higher peak efficiency voltage regulators that the power pulses from the voltage regulator. Redundant power operation In supported ProLiant 100-series G6 servers, redundant power supplies operate in "Balanced" mode, where power is based on the number of the sensors in a rotating...
... of DIMMs installed. Voltage regulation Voltage regulators convert the 12V DC supplied from both power supplies. HP has developed higher peak efficiency voltage regulators that the power pulses from the voltage regulator. Redundant power operation In supported ProLiant 100-series G6 servers, redundant power supplies operate in "Balanced" mode, where power is based on the number of the sensors in a rotating...
HP ProLiant Intel-based 100-series G6 server technology
Page 20
...G6 servers: • Health monitoring capabilities, including monitoring for drives, fans, network, power supplies, and temperature • Alerting capabilities, including basic alert notification for Smart Array drive pre-failure only • Performance monitoring capabilities providing information on the ProLiant...media capabilities. HP LO100i is plugged into an active power source. This functionality is not operating. HP LO100i is hardware and firmware that provides remote server access and control capabilities through HP SIM. HP Lights-Out 100i HP LO100i Remote...
...G6 servers: • Health monitoring capabilities, including monitoring for drives, fans, network, power supplies, and temperature • Alerting capabilities, including basic alert notification for Smart Array drive pre-failure only • Performance monitoring capabilities providing information on the ProLiant...media capabilities. HP LO100i is plugged into an active power source. This functionality is not operating. HP LO100i is hardware and firmware that provides remote server access and control capabilities through HP SIM. HP Lights-Out 100i HP LO100i Remote...
HP ProLiant Intel-based 100-series G6 server technology
Page 24
... server nodes, as well as the rest of the ProLiant 100-series G6 family. The HP ProLiant DL170h G6 server is mechanically unique in its chassis design, server node configuration, thermal management, and power supply utilization when compared to launch in the HP ProLiant h1000 G6 chassis. Chassis design The HP ProLiant h1000 G6 chassis can be used in a single node (DL170h), two...
... server nodes, as well as the rest of the ProLiant 100-series G6 family. The HP ProLiant DL170h G6 server is mechanically unique in its chassis design, server node configuration, thermal management, and power supply utilization when compared to launch in the HP ProLiant h1000 G6 chassis. Chassis design The HP ProLiant h1000 G6 chassis can be used in a single node (DL170h), two...
HP ProLiant Intel-based 100-series G6 server technology
Page 26
... is not a "Common Slot" power supply). HP provides a simple command-line utility for reading and configuring the power control logic of the DL1000 G6 system Fan Control Board fan1 fan2 fan3 fan4 Node 3 Node 4 Node 1 Node 2 Power supply support The DL1000 Multi Node server supports both power supplies and run at maximum performance with power throttling) - Versions are available for...
... is not a "Common Slot" power supply). HP provides a simple command-line utility for reading and configuring the power control logic of the DL1000 G6 system Fan Control Board fan1 fan2 fan3 fan4 Node 3 Node 4 Node 1 Node 2 Power supply support The DL1000 Multi Node server supports both power supplies and run at maximum performance with power throttling) - Versions are available for...
HP ProLiant Intel-based 100-series G6 server technology
Page 27
... mode, the chassis is another means for optimum power efficiency. 27 The user specifies the power envelope for the DL 100series G6 servers. Summary The HP ProLiant 100-series G6 servers help administrators increase business performance, lower power costs, and manage their data center requirements. Users run a utility to one power supply experiences a DC or AC failure, the chassis...
... mode, the chassis is another means for optimum power efficiency. 27 The user specifies the power envelope for the DL 100series G6 servers. Summary The HP ProLiant 100-series G6 servers help administrators increase business performance, lower power costs, and manage their data center requirements. Users run a utility to one power supply experiences a DC or AC failure, the chassis...