HP PCL/PJL reference - Printer Job Language Technical Reference Addendum
Page 137
...40019 40020 40021 40022 40024 40025 40026 40026 40038 40039 40046 40047 40048 40049 40050 40051 40052 40053 SLEEP MODE (STANDBY) Cartridge error during align cartridges (or reading setup sheet-Designjet) 14 NO EP CART or INSTALL TONER CARTRIDGE or no electrical contact with one...FI INSERT CART FR REMOVE CART [PJL OPMSG] [PJL STMSG] 50 SERVICE or 50 FUSER ERROR, CYCLE POWER 51 ERROR or 51 PRINTER ERROR, CYCLE POWER 52 ERROR or 52 PRINTER ERROR, CYCLE POWER 53-xy-zz ERROR 40054 54 ERROR 40055 55 ERROR 40056 56 ERROR * This is addressed. Table 28. ENWW Operator intervention conditions (...
...40019 40020 40021 40022 40024 40025 40026 40026 40038 40039 40046 40047 40048 40049 40050 40051 40052 40053 SLEEP MODE (STANDBY) Cartridge error during align cartridges (or reading setup sheet-Designjet) 14 NO EP CART or INSTALL TONER CARTRIDGE or no electrical contact with one...FI INSERT CART FR REMOVE CART [PJL OPMSG] [PJL STMSG] 50 SERVICE or 50 FUSER ERROR, CYCLE POWER 51 ERROR or 51 PRINTER ERROR, CYCLE POWER 52 ERROR or 52 PRINTER ERROR, CYCLE POWER 53-xy-zz ERROR 40054 54 ERROR 40055 55 ERROR 40056 56 ERROR * This is addressed. Table 28. ENWW Operator intervention conditions (...
HP PCL/PJL reference - Printer Job Language Technical Reference Addendum
Page 149
... 50005 50006 50007 50008 50009 Engine beam detect error Engine scanner error Engine fan error Engine communications error 50.1 FUSER ERROR CYCLE POWER or LOW FUSER TEMPERATURE 50.2 FUSER ERROR CYCLE POWER or FUSER TOOK TOO LONG TO WARM UP 50010 50011 50012 50013 50.3 FUSER ERROR CYCLE POWER or FUSER TOO HOT 50.4 FUSER ERROR CYCLE POWER or BAD FUSER 51.1 ERROR PRESS SELECT KEY or BEAM DETECT MALFUNCTION 51...
... 50005 50006 50007 50008 50009 Engine beam detect error Engine scanner error Engine fan error Engine communications error 50.1 FUSER ERROR CYCLE POWER or LOW FUSER TEMPERATURE 50.2 FUSER ERROR CYCLE POWER or FUSER TOOK TOO LONG TO WARM UP 50010 50011 50012 50013 50.3 FUSER ERROR CYCLE POWER or FUSER TOO HOT 50.4 FUSER ERROR CYCLE POWER or BAD FUSER 51.1 ERROR PRESS SELECT KEY or BEAM DETECT MALFUNCTION 51...
HP PCL/PJL reference - Printer Job Language Technical Reference Manual
Page 316
... conditions where operator intervention is required. Printing cannot continue until the condition is not an error. Operator Intervention Conditions (40xxx) This list specifies the set of PJL error codes and corresponding control panel display strings for data. Status Code Display String or Code ...CART 40047 FR REMOVE CART 40048 [PJL OPMSG] 40049 [PJL STMSG] 40050 50 SERVICE or 50 FUSER ERROR, CYCLE POWER 40051 51 ERROR or 51 PRINTER ERROR, CYCLE POWER 40052 52 ERROR or 52 PRINTER ERROR, CYCLE POWER 40053 53-xy-zz ERROR * This is resolved. D-16 PJL Status Codes EN
... conditions where operator intervention is required. Printing cannot continue until the condition is not an error. Operator Intervention Conditions (40xxx) This list specifies the set of PJL error codes and corresponding control panel display strings for data. Status Code Display String or Code ...CART 40047 FR REMOVE CART 40048 [PJL OPMSG] 40049 [PJL STMSG] 40050 50 SERVICE or 50 FUSER ERROR, CYCLE POWER 40051 51 ERROR or 51 PRINTER ERROR, CYCLE POWER 40052 52 ERROR or 52 PRINTER ERROR, CYCLE POWER 40053 53-xy-zz ERROR * This is resolved. D-16 PJL Status Codes EN
HP PCL/PJL reference - Printer Job Language Technical Reference Manual
Page 324
... malfunction [DesignJet]) 50003 Engine Fuser Error 50004 Engine Beam Detect Error 50005 Engine Scanner Error 50006 Engine Fan Error 50007 Engine Communications Error 50008 50.1 FUSER ERROR CYCLE POWER or LOW FUSER TEMPERATURE 50009 50.2 FUSER ERROR CYCLE POWER or FUSER TOOK TOO LONG TO WARM UP 50010 50.3 FUSER ERROR CYCLE POWER or FUSER TOO HOT 50011 50.4 FUSER ERROR CYCLE POWER or BAD FUSER 50012 51.1 ERROR PRESS SELECT KEY or...
... malfunction [DesignJet]) 50003 Engine Fuser Error 50004 Engine Beam Detect Error 50005 Engine Scanner Error 50006 Engine Fan Error 50007 Engine Communications Error 50008 50.1 FUSER ERROR CYCLE POWER or LOW FUSER TEMPERATURE 50009 50.2 FUSER ERROR CYCLE POWER or FUSER TOOK TOO LONG TO WARM UP 50010 50.3 FUSER ERROR CYCLE POWER or FUSER TOO HOT 50011 50.4 FUSER ERROR CYCLE POWER or BAD FUSER 50012 51.1 ERROR PRESS SELECT KEY or...
HP LaserJet 5000, 5000 N, 5000 GN, and 5000 DN Printers - User Guide
Page 98
... [Go]. The page containing the error will automatically be reprinted. Press [Go]. If this message persists, contact an HP-authorized service or support provider. (See the HP Support pages at the front of this user's guide.) 50.x FUSER ERROR An internal error has occurred. Turn the printer off... , and then replace the DIMM that caused the error will automatically be used. ...
... [Go]. The page containing the error will automatically be reprinted. Press [Go]. If this message persists, contact an HP-authorized service or support provider. (See the HP Support pages at the front of this user's guide.) 50.x FUSER ERROR An internal error has occurred. Turn the printer off... , and then replace the DIMM that caused the error will automatically be used. ...
HP LaserJet 5000, 5000 N, 5000 GN, and 5000 DN Printers - User Guide
Page 196
Configure Fuser Mode Menu setting B-4 configuring duplex printing accessory 35 ...53 orientation 40-41 paper specifications A-5 printing 28, 50-54 setting paper size 53 D dark printing, setting toner density B-6 Data light 11 data, transmitting speed B-16 dealers, HP authorized, see front pages Declaration of Conformity E-7 ...42, A-10 environmental product stewardship E-2-E-7 environmental specifications A-17-A-18 equivalent weights to US paper A-8 error log, see event log error messages 79-88 clearing repeated messages 79 escape characters entering in DOS D-3 examples D-2 escape sequences ...
Configure Fuser Mode Menu setting B-4 configuring duplex printing accessory 35 ...53 orientation 40-41 paper specifications A-5 printing 28, 50-54 setting paper size 53 D dark printing, setting toner density B-6 Data light 11 data, transmitting speed B-16 dealers, HP authorized, see front pages Declaration of Conformity E-7 ...42, A-10 environmental product stewardship E-2-E-7 environmental specifications A-17-A-18 equivalent weights to US paper A-8 error log, see event log error messages 79-88 clearing repeated messages 79 escape characters entering in DOS D-3 examples D-2 escape sequences ...
HP LaserJet 5000, 5000 N, 5000 GN, and 5000 DN Printers - User Guide
Page 197
...troubleshooting 98 FontSmart, see HP FontSmart format problems, troubleshooting 94-95 frequent paper jams, clearing 78 full-bleed images, printing 49 Fuser Error message 86 G garbled print...warranty 105-106 heavy paper printing 28, 50-53 problems with A-12 specifications A-12 weight specifications A-12 Help...HP JetSend, installing 20 HP JobMonitor, accessing 19 HP LaserJet Toner Cartridge Recycling Program E-3 HP Maintenance Agreement 106 HP Software License Term 109 HP Support Pack 106 HP support, see front pages HP ToolBox, accessing 19 HP worldwide sales and service offices 110-112 HP-GL/2 commands D-1 HP...
...troubleshooting 98 FontSmart, see HP FontSmart format problems, troubleshooting 94-95 frequent paper jams, clearing 78 full-bleed images, printing 49 Fuser Error message 86 G garbled print...warranty 105-106 heavy paper printing 28, 50-53 problems with A-12 specifications A-12 weight specifications A-12 Help...HP JetSend, installing 20 HP JobMonitor, accessing 19 HP LaserJet Toner Cartridge Recycling Program E-3 HP Maintenance Agreement 106 HP Software License Term 109 HP Support Pack 106 HP support, see front pages HP ToolBox, accessing 19 HP worldwide sales and service offices 110-112 HP-GL/2 commands D-1 HP...
Service Manual
Page 118
... roller contains a ceramic heating element that is monitored by heat and pressure to produce a permanent image. The DC Controller Board maintains a variable fuser temperature that provides heat for the fusing process. The paper passes between a heated fusing roller and a soft pressure roller. This melts the toner...the fusing system exceeds 464° F (240° C), the thermal fuse will open, cutting off power to the Fusing Heater, causing a Fuser error message (50.X FUSER ERROR). If the fusing system overheats (about 446° F/230° C), a relay opens, interrupting power to the...
... roller contains a ceramic heating element that is monitored by heat and pressure to produce a permanent image. The DC Controller Board maintains a variable fuser temperature that provides heat for the fusing process. The paper passes between a heated fusing roller and a soft pressure roller. This melts the toner...the fusing system exceeds 464° F (240° C), the thermal fuse will open, cutting off power to the Fusing Heater, causing a Fuser error message (50.X FUSER ERROR). If the fusing system overheats (about 446° F/230° C), a relay opens, interrupting power to the...
Service Manual
Page 236
...to gain a clear picture of the Event Log printout with the 02 signifying that event. The Event Log may record errors in the left-most column. For example, should a 50.1 FUSER ERROR / CYCLE POWER be displayed on the Control Panel, a good practice is called an "event". Likewise, when a 13....1 through 13.9 are called an "error," and all the jammed paper from device (Error 66.xx in the Event Log) which requires a...
...to gain a clear picture of the Event Log printout with the 02 signifying that event. The Event Log may record errors in the left-most column. For example, should a 50.1 FUSER ERROR / CYCLE POWER be displayed on the Control Panel, a good practice is called an "event". Likewise, when a 13....1 through 13.9 are called an "error," and all the jammed paper from device (Error 66.xx in the Event Log) which requires a...
Service Manual
Page 253
... is no continuity, replace the Fuser. Turn the printer off and 3 High Fuser temperature. connectors J1307-1 and J1307-2. If there is no continuity, replace the Fuser. 4. continuity between connectors J1308-3 and J1308-1 with the Fuser removed. Numerical Printer Messages (continued) Control Panel Message Event Explanation Log Message Recommended Action 50.x FUSER ERROR A Fuser error has 1. Turn the power off...
... is no continuity, replace the Fuser. Turn the printer off and 3 High Fuser temperature. connectors J1307-1 and J1307-2. If there is no continuity, replace the Fuser. 4. continuity between connectors J1308-3 and J1308-1 with the Fuser removed. Numerical Printer Messages (continued) Control Panel Message Event Explanation Log Message Recommended Action 50.x FUSER ERROR A Fuser error has 1. Turn the power off...