EMC PowerSwitch S5200F-ON Series Setup Guide
Page 4
...E21W005. • Marketing model S5248F-ON is represented by the regulatory model E21W and the regulatory type E21W002. • Marketing model S5224F-ON is represented by the regulatory model E21W and the regulatory type E21W003. • Marketing model S5296F-ON is represented by the ...For more information about the S5200F-ON Series (S5232F-ON, S5248F-ON, S5296F-ON, S5224F-ON, and S5212F-ON) switches, see the following documents. • Dell EMC SmartFabric OS10 Release Notes • Dell EMC SmartFabric OS10 User Guide • Delll EMC PowerSwitch S5200F-ON Series Installation Guide ...
...E21W005. • Marketing model S5248F-ON is represented by the regulatory model E21W and the regulatory type E21W002. • Marketing model S5224F-ON is represented by the regulatory model E21W and the regulatory type E21W003. • Marketing model S5296F-ON is represented by the ...For more information about the S5200F-ON Series (S5232F-ON, S5248F-ON, S5296F-ON, S5224F-ON, and S5212F-ON) switches, see the following documents. • Dell EMC SmartFabric OS10 Release Notes • Dell EMC SmartFabric OS10 User Guide • Delll EMC PowerSwitch S5200F-ON Series Installation Guide ...
EMC PowerSwitch S5200F-ON Series Setup Guide
Page 9
... conductors must facilitate proper operation of the outside rail. Do not use the ReadyRails system for the S5232F-ON, S5248F-ON, and S5224F-ON switches includes four-post, two-post, round threaded holes, or square holes. Read the safety instructions in a permanent location before... exceed the circuit capabilities. Stabilize racks in your switch with the other end of the AC power cable provides a ground path, Dell EMC recommends grounding your Safety, Environmental, and Regulatory information booklet before loading begins. Before you begin installation, separate each rail assembly...
... conductors must facilitate proper operation of the outside rail. Do not use the ReadyRails system for the S5232F-ON, S5248F-ON, and S5224F-ON switches includes four-post, two-post, round threaded holes, or square holes. Read the safety instructions in a permanent location before... exceed the circuit capabilities. Stabilize racks in your switch with the other end of the AC power cable provides a ground path, Dell EMC recommends grounding your Safety, Environmental, and Regulatory information booklet before loading begins. Before you begin installation, separate each rail assembly...
EMC PowerSwitch S5200F-ON Series Setup Guide
Page 24
...ON: 635W = 2167 BTU/Hr S5248F-ON: 647W = 2208 BTU/Hr S5296F-ON: 893W = 3047 BTU/Hr S5224F-ON: 455W = 1552 BTU/Hr S5212F-ON: 304W = 1037 BTU/Hr 10,000 feet (3,048 meters) 39,370 feet (12,000... meters) Dell EMC Spec SV0115 Specifications S5232F-ON: 100-240 VAC 50/60 Hz S5248F-ON: 100-240 VAC 50/60 Hz S5296F-ON: 100-240 VAC 50/60 Hz S5224F-ON: 100-240 VAC 50/60... 5.8A@110VAC and 2.4A@220VAC S5248F-ON: 5.8A@110VAC and 2.4A@220VAC S5296F-ON: 8.2A@110VAC and 4.1A@220VAC S5224F-ON: 4.2A@110VAC and 2.1A@220VAC S5212F-ON: 2.8A@110VAC and 1.4A@220VAC S5232F-ON: 635W maximum S5248F-ON: ...
...ON: 635W = 2167 BTU/Hr S5248F-ON: 647W = 2208 BTU/Hr S5296F-ON: 893W = 3047 BTU/Hr S5224F-ON: 455W = 1552 BTU/Hr S5212F-ON: 304W = 1037 BTU/Hr 10,000 feet (3,048 meters) 39,370 feet (12,000... meters) Dell EMC Spec SV0115 Specifications S5232F-ON: 100-240 VAC 50/60 Hz S5248F-ON: 100-240 VAC 50/60 Hz S5296F-ON: 100-240 VAC 50/60 Hz S5224F-ON: 100-240 VAC 50/60... 5.8A@110VAC and 2.4A@220VAC S5248F-ON: 5.8A@110VAC and 2.4A@220VAC S5296F-ON: 8.2A@110VAC and 4.1A@220VAC S5224F-ON: 4.2A@110VAC and 2.1A@220VAC S5212F-ON: 2.8A@110VAC and 1.4A@220VAC S5232F-ON: 635W maximum S5248F-ON: ...
EMC PowerSwitch S5200F-ON Series Installation Guide February 2022
Page 5
... documents For more information about the S5200F-ON Series (S5232F-ON, S5248F-ON, S5296F-ON, S5224F-ON, and S5212F-ON) see the following documents: ● Dell EMC SmartFabric User Guide ● Dell EMC SmartFabric Release Notes ● Dell EMC PowerSwitch S5200F-ON Series Set-up this equipment. 1 About this guide This guide provides site...
... documents For more information about the S5200F-ON Series (S5232F-ON, S5248F-ON, S5296F-ON, S5224F-ON, and S5212F-ON) see the following documents: ● Dell EMC SmartFabric User Guide ● Dell EMC SmartFabric Release Notes ● Dell EMC PowerSwitch S5200F-ON Series Set-up this equipment. 1 About this guide This guide provides site...
EMC PowerSwitch S5200F-ON Series Installation Guide February 2022
Page 7
...the following configurations: ● 24 x 25GbE ● 24 x 10GbE The S5212F-ON supports the following sections describe the Dell EMC S5200F-ON Series (S5232F-ON, S5248F-ON, S5296F-ON, S5224F-ON, and S5212F-ON) switch: Topics: • Introduction • Features • Physical dimensions • LED display... Prerequisites • S5200F-ON Series switch configurations • Luggage tag Introduction The S5200F-ON Series (S5232F-ON, S5248F-ON, S5296F-ON, S5224F-ON, and S5212F-ON) switch is a 10/25/40/50/100/200GbE switch with small formfactor pluggable plus (SFP+), small form-factor ...
...the following configurations: ● 24 x 25GbE ● 24 x 10GbE The S5212F-ON supports the following sections describe the Dell EMC S5200F-ON Series (S5232F-ON, S5248F-ON, S5296F-ON, S5224F-ON, and S5212F-ON) switch: Topics: • Introduction • Features • Physical dimensions • LED display... Prerequisites • S5200F-ON Series switch configurations • Luggage tag Introduction The S5200F-ON Series (S5232F-ON, S5248F-ON, S5296F-ON, S5224F-ON, and S5212F-ON) switch is a 10/25/40/50/100/200GbE switch with small formfactor pluggable plus (SFP+), small form-factor ...
EMC PowerSwitch S5200F-ON Series Installation Guide February 2022
Page 28
...ports of the equipment or subassembly are not a suitable grounding point. The rack installation ears are suitable for the S5232F-ON, S5248F-ON, and S5224F-ON switches includes four-post, two-post, round threaded holes, or square holes. For the S5212F-ON switch, see Two U four-post rack...connect the switch to intrabuilding or unexposed wiring or cabling-only of the intrabuilding port(s) of the AC power cord provides a ground path, Dell EMC recommends grounding your user-supplied ground cable to the switch. Cut your switch with an anti-oxidant before crimping. NOTE: If you...
...ports of the equipment or subassembly are not a suitable grounding point. The rack installation ears are suitable for the S5232F-ON, S5248F-ON, and S5224F-ON switches includes four-post, two-post, round threaded holes, or square holes. For the S5212F-ON switch, see Two U four-post rack...connect the switch to intrabuilding or unexposed wiring or cabling-only of the intrabuilding port(s) of the AC power cord provides a ground path, Dell EMC recommends grounding your user-supplied ground cable to the switch. Cut your switch with an anti-oxidant before crimping. NOTE: If you...
EMC PowerSwitch S5200F-ON Series Installation Guide February 2022
Page 42
... if components are mishandled. Optics installation The S5200F-ON Series (S5232F-ON, S5248F-ON, S5296F-ON, S5224F-ON, and S5212F-ON) switches have securely installed and powered on at www.dell.com/support or contact your switch before powering it gently snaps into the port until it up an AC... AC or DC power cable is mounted in a rack or cabinet. Optics removal Remove an optic by pushing the tab on the tab. Dell EMC recommends reinspecting your Dell EMC Sales representative. Start up sequence When the switch powers up the switch if a fan module is not installed. For a list of...
... if components are mishandled. Optics installation The S5200F-ON Series (S5232F-ON, S5248F-ON, S5296F-ON, S5224F-ON, and S5212F-ON) switches have securely installed and powered on at www.dell.com/support or contact your switch before powering it gently snaps into the port until it up an AC... AC or DC power cable is mounted in a rack or cabinet. Optics removal Remove an optic by pushing the tab on the tab. Dell EMC recommends reinspecting your Dell EMC Sales representative. Start up sequence When the switch powers up the switch if a fan module is not installed. For a list of...
EMC PowerSwitch S5200F-ON Series Installation Guide February 2022
Page 58
...kg)-PSUs and fans S5248F-ON: 21.4 lbs (9.7 kg)-PSUs and fans S5296F-ON: 33.3 lbs (15.1 kg)-PSUs and fans S5224F-ON: 21.4 lbs (9.7 kg)-PSUs and fans S5212F-ON: 10.05 lbs (4.5 kg)-PSUs and fans Front: 5 inches (12... (12,000 meters) Dell EMC Spec SV0115 Specifications S5232F-ON: 100-240 VAC 50/60 Hz S5248F-ON: 100-240 VAC 50/60 Hz S5296F-ON: 100-240 VAC 50/60 Hz S5224F-ON: 100-240 VAC... and 2.4A@220VAC S5248F-ON: 5.8A@110VAC and 2.4A@220VAC S5296F-ON: 8.2A@110VAC and 4.1A@220VAC S5224F-ON: 4.2A@110VAC and 2.1A@220VAC S5212F-ON: 2.8A@110VAC and 1.4A@220VAC 58 Specifications Chassis physical design...
...kg)-PSUs and fans S5248F-ON: 21.4 lbs (9.7 kg)-PSUs and fans S5296F-ON: 33.3 lbs (15.1 kg)-PSUs and fans S5224F-ON: 21.4 lbs (9.7 kg)-PSUs and fans S5212F-ON: 10.05 lbs (4.5 kg)-PSUs and fans Front: 5 inches (12... (12,000 meters) Dell EMC Spec SV0115 Specifications S5232F-ON: 100-240 VAC 50/60 Hz S5248F-ON: 100-240 VAC 50/60 Hz S5296F-ON: 100-240 VAC 50/60 Hz S5224F-ON: 100-240 VAC... and 2.4A@220VAC S5248F-ON: 5.8A@110VAC and 2.4A@220VAC S5296F-ON: 8.2A@110VAC and 4.1A@220VAC S5224F-ON: 4.2A@110VAC and 2.1A@220VAC S5212F-ON: 2.8A@110VAC and 1.4A@220VAC 58 Specifications Chassis physical design...
EMC PowerSwitch S5200F-ON Series Installation Guide February 2022
Page 59
... input voltage range Maximum current at their own expense. If it is not responsible for a Class A digital device, pursuant to radio communications. Dell EMC is not installed and used in a commercial environment. Table 9. AC power requirements (continued) Parameter Maximum power consumption Typical power consumption Table 10...-ON: 208W typical Specifications -40VDC minimum S5232F-ON: 15.9A @40VDC S5248F-ON: 16.2A @40VDC S5296F-ON: 22.3A @40VDC S5224F-ON: 11.4A@40VDC S5212F-ON: 7.6A@40VDC IEEE standards The S5200F-ON Series switch complies with the limits for any radio or television...
... input voltage range Maximum current at their own expense. If it is not responsible for a Class A digital device, pursuant to radio communications. Dell EMC is not installed and used in a commercial environment. Table 9. AC power requirements (continued) Parameter Maximum power consumption Typical power consumption Table 10...-ON: 208W typical Specifications -40VDC minimum S5232F-ON: 15.9A @40VDC S5248F-ON: 16.2A @40VDC S5296F-ON: 22.3A @40VDC S5224F-ON: 11.4A@40VDC S5212F-ON: 7.6A@40VDC IEEE standards The S5200F-ON Series switch complies with the limits for any radio or television...