Product Manual
Page 3
... Settings...20 SNMP Settings ...21 i Table of Contents D-Link Web Smart Switch User Manual Table of Contents Table of Contents ...i About This Guide...1 Terms/Usage...1 Copyright and Trademarks ...1 Product Introduction ...2 DES-1210-08P ...3 Front Panel ...3 Rear Panel...3 DES-1210-28 ...3 Front Panel ...3 Rear Panel...4 DES-1210-28P ...4 Front Panel ...4 Rear Panel...5 DES-1210-52 ...5 Front Panel ...5 Rear Panel...6 Hardware Installation ...7 Step 1: Unpacking...
... Settings...20 SNMP Settings ...21 i Table of Contents D-Link Web Smart Switch User Manual Table of Contents Table of Contents ...i About This Guide...1 Terms/Usage...1 Copyright and Trademarks ...1 Product Introduction ...2 DES-1210-08P ...3 Front Panel ...3 Rear Panel...3 DES-1210-28 ...3 Front Panel ...3 Rear Panel...4 DES-1210-28P ...4 Front Panel ...4 Rear Panel...5 DES-1210-52 ...5 Front Panel ...5 Rear Panel...6 Hardware Installation ...7 Step 1: Unpacking...
Product Manual
Page 4
Table of Contents D-Link Web Smart Switch User Manual System Settings...22 Web-based Management...23 Tool Bar > Save Menu ...24 Save Configuration ...24 Save Log ...24 Tool Bar ... Auto Surveillance VLAN > Auto Surveillance VLAN Settings 40 Configuration > Link Aggregation > Port Trunking 41 Configuration > Link Aggregation > LACP Port Settings 42 Configuration > IGMP Snooping ...43 Configuration > Multicast Filtering Mode (For DES-1210-08P only 44 Configuration > Multicast Filtering Mode (For DES-1210-28/28P/52 45 Configuration > Port Mirroring ...45 Configuration > Loopback Detection ......
Table of Contents D-Link Web Smart Switch User Manual System Settings...22 Web-based Management...23 Tool Bar > Save Menu ...24 Save Configuration ...24 Save Log ...24 Tool Bar ... Auto Surveillance VLAN > Auto Surveillance VLAN Settings 40 Configuration > Link Aggregation > Port Trunking 41 Configuration > Link Aggregation > LACP Port Settings 42 Configuration > IGMP Snooping ...43 Configuration > Multicast Filtering Mode (For DES-1210-08P only 44 Configuration > Multicast Filtering Mode (For DES-1210-28/28P/52 45 Configuration > Port Mirroring ...45 Configuration > Loopback Detection ......
Product Manual
Page 7
... appear slightly different from the illustrations shown in this document is subjected to change without the written permission of D-Link Corporation; About This Guide D-Link Web Smart Switch User Manual About This Guide This guide provides instructions to install the D-Link Fast Ethernet Web Smart Switch DES-121008P/28/28P/52, how to use of Microsoft Corporation.
... appear slightly different from the illustrations shown in this document is subjected to change without the written permission of D-Link Corporation; About This Guide D-Link Web Smart Switch User Manual About This Guide This guide provides instructions to install the D-Link Fast Ethernet Web Smart Switch DES-121008P/28/28P/52, how to use of Microsoft Corporation.
Product Manual
Page 9
...turn on 10M. Fan OK/Fail LED: The FAN LED shows the status of power adapter. 1 Product Introduction DES-1210-08P 8-Port 10/100Mpbs PoE Web Smart Switch Front Panel D-Link Web Smart Switch User Manual Figure 1 - PoE LED (1-8): The PoE LED lights up when the Switch is running on /off indicates ...Front Panel Power LED : The Power LED lights up with solid green indicates power device is running on or multiple fans are working abnormally. DES-1210-28 Rear Panel DC Power Jack: The power jack is connected to the port. Blinking indicates that on 100M. Power Max LED: The Power Max...
...turn on 10M. Fan OK/Fail LED: The FAN LED shows the status of power adapter. 1 Product Introduction DES-1210-08P 8-Port 10/100Mpbs PoE Web Smart Switch Front Panel D-Link Web Smart Switch User Manual Figure 1 - PoE LED (1-8): The PoE LED lights up when the Switch is running on /off indicates ...Front Panel Power LED : The Power LED lights up with solid green indicates power device is running on or multiple fans are working abnormally. DES-1210-28 Rear Panel DC Power Jack: The power jack is connected to the port. Blinking indicates that on 100M. Power Max LED: The Power Max...
Product Manual
Page 10
... light off indicates this port. 1 Product Introduction D-Link Web Smart Switch User Manual Port Link/Act/Speed LED (25F, 26F, 25T, 26T, 27, 28): The Link/Act/Speed LED flashes which indicate a network link through the corresponding port. When it has a green light it is connected to corresponding port. DES-1210-28P 24-Port 10/100Mpbs PoE with...
... light off indicates this port. 1 Product Introduction D-Link Web Smart Switch User Manual Port Link/Act/Speed LED (25F, 26F, 25T, 26T, 27, 28): The Link/Act/Speed LED flashes which indicate a network link through the corresponding port. When it has a green light it is connected to corresponding port. DES-1210-28P 24-Port 10/100Mpbs PoE with...
Product Manual
Page 11
...10M or 100M. DES-1210-52 48-Port 10/100Mpbs Web Smart Switch with 4-Port 10/100/1000Mbps and 2 Combo SFPs Front Panel Figure 7 - Port Link/Act/Speed LED (49F, 50F, 49T, 50T, 51, 52): The Link/Act/Speed LED flashes which indicates a network link through the corresponding port... . 1 Product Introduction D-Link Web Smart Switch User Manual Port LED (25F, 26F, 25T, 26T, 27, 28): The Port LED flashes which indicates a network link through the corresponding port. Port Link/Act/Speed LED (1-48): The Link/Act/Speed LED flashes which indicates a network link through the corresponding port....
...10M or 100M. DES-1210-52 48-Port 10/100Mpbs Web Smart Switch with 4-Port 10/100/1000Mbps and 2 Combo SFPs Front Panel Figure 7 - Port Link/Act/Speed LED (49F, 50F, 49T, 50T, 51, 52): The Link/Act/Speed LED flashes which indicates a network link through the corresponding port... . 1 Product Introduction D-Link Web Smart Switch User Manual Port LED (25F, 26F, 25T, 26T, 27, 28): The Port LED flashes which indicates a network link through the corresponding port. Port Link/Act/Speed LED (1-48): The Link/Act/Speed LED flashes which indicates a network link through the corresponding port....
Product Manual
Page 15
Figure 13 - Power surge may cause damage to the outside plant. Plugging DES-1210-28/28P/52 into an outlet CAUTION: Do not turn on the power switch of power failure. Plugging the DES-1210-08P into an outlet Power Failure As a precaution, the switch should be connected only to PoE networks ...to the Switch. CAUTION: The installation instructions clearly state that the ITE is resumed, plug the switch back in case of DES-1210-08P before power cables are connected. When power is to be unplugged in . 9 2 Hardware Installation D-Link Web Smart Switch User Manual Figure 12 -
Figure 13 - Power surge may cause damage to the outside plant. Plugging DES-1210-28/28P/52 into an outlet CAUTION: Do not turn on the power switch of power failure. Plugging the DES-1210-08P into an outlet Power Failure As a precaution, the switch should be connected only to PoE networks ...to the Switch. CAUTION: The installation instructions clearly state that the ITE is resumed, plug the switch back in case of DES-1210-08P before power cables are connected. When power is to be unplugged in . 9 2 Hardware Installation D-Link Web Smart Switch User Manual Figure 12 -
Product Manual
Page 24
...Here you can configure the Switch through the Web-based Management utility. Click this icon to remove it. SmartConsole Add device Figure 28 - SmartConsole Delete device Device List This list displays all the Web-Smart devices located in the device list. Click the + and... Web-Smart devices on the network. SmartConsole Device List Definitions of the Device List features: 18 Figure 29 - 4 SmartConsole Utility D-Link Web Smart Switch User Manual Figure 26 - The Internet Explorer). button to launch your internet browser (eg. You may also get into Discover List, or select...
...Here you can configure the Switch through the Web-based Management utility. Click this icon to remove it. SmartConsole Add device Figure 28 - SmartConsole Delete device Device List This list displays all the Web-Smart devices located in the device list. Click the + and... Web-Smart devices on the network. SmartConsole Device List Definitions of the Device List features: 18 Figure 29 - 4 SmartConsole Utility D-Link Web Smart Switch User Manual Figure 26 - The Internet Explorer). button to launch your internet browser (eg. You may also get into Discover List, or select...
Product Manual
Page 34
... Smart Switch User Manual Function Tree All configuration options on the switch are accessed through the Setup menu on the setup item that you want to configure. It also offers an overall status of the screen. Safeguard Engine: Click Setting to link to Configuration >... each feature and function. Port Mirroring: Click Setting to link to Configuration > QoS > Storm Control. Default is disabled. Default is enabled. Device Information 28 Storm Control: Click Setting to link to Configuration > Port Mirroring. SNMP: Click Setting to link to Configuration > Security > 802.1X > 802.1X...
... Smart Switch User Manual Function Tree All configuration options on the switch are accessed through the Setup menu on the setup item that you want to configure. It also offers an overall status of the screen. Safeguard Engine: Click Setting to link to Configuration >... each feature and function. Port Mirroring: Click Setting to link to Configuration > QoS > Storm Control. Default is disabled. Default is enabled. Device Information 28 Storm Control: Click Setting to link to Configuration > Port Mirroring. SNMP: Click Setting to link to Configuration > Security > 802.1X > 802.1X...
Product Manual
Page 41
...log messages. Click Enable so you can start to configure the related settings of system logs. Severity: Specifies the minimum severity from 01 to 28 as "Untagged" Rename: Click to take effect. All - Only one VID. The IEEE 802.1Q VLAN Configuration page provides powerful VID management...remote server. Time Stamp: Select Enable to delete the VLAN group. To save the VID group, click Apply. 35 5 Configuration D-Link Web Smart Switch User Manual Figure 59 - The original settings have the VID as 1, no default name, and all levels of remote system log server, ...
...log messages. Click Enable so you can start to configure the related settings of system logs. Severity: Specifies the minimum severity from 01 to 28 as "Untagged" Rename: Click to take effect. All - Only one VID. The IEEE 802.1Q VLAN Configuration page provides powerful VID management...remote server. Time Stamp: Select Enable to delete the VLAN group. To save the VID group, click Apply. 35 5 Configuration D-Link Web Smart Switch User Manual Figure 59 - The original settings have the VID as 1, no default name, and all levels of remote system log server, ...
Product Manual
Page 51
...Port. Filter Unregistered Groups: The registered group will be forwarded based on the register table in the network, especially when the down links are as follows: TX (transmit) mode: Duplicates the data transmitted from the source port and forwards it will be studied. Both... Filtering Mode (For DES-1210-28/28P/52) The Multicast Filtering Mode function allows users to detect the loop created by a specific port while Spanning Tree Protocol (STP) is used to select the filtering mode for IGMP group per VLAN basis. 5 Configuration D-Link Web Smart Switch User Manual Figure 79 -
...Port. Filter Unregistered Groups: The registered group will be forwarded based on the register table in the network, especially when the down links are as follows: TX (transmit) mode: Duplicates the data transmitted from the source port and forwards it will be studied. Both... Filtering Mode (For DES-1210-28/28P/52) The Multicast Filtering Mode function allows users to detect the loop created by a specific port while Spanning Tree Protocol (STP) is used to select the filtering mode for IGMP group per VLAN basis. 5 Configuration D-Link Web Smart Switch User Manual Figure 79 -
Product Manual
Page 56
... loop. If set to True, the port will drop packets coming into the Switch until the storm has subsided. If set here. For DES-1210-28/28P/52, the threshold is from 0 to 16000. Click Apply for this status, (for the settings to have p2p status. Selecting the Auto parameter ...that the port does not have edge port status automatically. Threshold: If storm control is enabled (default is 128. 5 Configuration D-Link Web Smart Switch User Manual Edge: Selecting the True parameter designates the port as if the p2p status were true. Edge ports cannot create loops, however ...
... loop. If set to True, the port will drop packets coming into the Switch until the storm has subsided. If set here. For DES-1210-28/28P/52, the threshold is from 0 to 16000. Click Apply for this status, (for the settings to have p2p status. Selecting the Auto parameter ...that the port does not have edge port status automatically. Threshold: If storm control is enabled (default is 128. 5 Configuration D-Link Web Smart Switch User Manual Edge: Selecting the True parameter designates the port as if the p2p status were true. Edge ports cannot create loops, however ...
Product Manual
Page 57
...conferencing. Type: This drop-down menu allows you to specify that the selected port will be first handled by the switch. For DES-1210-28/28P/52, the value is limited, and therefore excessive bandwidth can only be saved. Click Apply to the lower multiple of each port, ... depending on your configuration. 51 The following figure displays the status of Quality of Service priority levels of 1850. 5 Configuration D-Link Web Smart Switch User Manual Figure 88 - For packets that are untagged, the switch will be the limit for important functions that require a larger bandwidth...
...conferencing. Type: This drop-down menu allows you to specify that the selected port will be first handled by the switch. For DES-1210-28/28P/52, the value is limited, and therefore excessive bandwidth can only be saved. Click Apply to the lower multiple of each port, ... depending on your configuration. 51 The following figure displays the status of Quality of Service priority levels of 1850. 5 Configuration D-Link Web Smart Switch User Manual Figure 88 - For packets that are untagged, the switch will be the limit for important functions that require a larger bandwidth...
Product Manual
Page 81
Technical Specifications D-Link Web Smart Switch User Manual Appendix B - DES-1210-28P: 9.5Mpps Forwarding Mode: Store and Forward Packet Buffer memory: 256K Bytes DDRII for CPU: 64M Bytes Flash Memory: 16M Bytes Port Functions 8, 24 ... - DES-1210-08P/28/52: 0dB (Fan-less) - IEEE 802.3at (DES-1210-28P only) - DEM-315GT (1000BASE-ZX, 80km) - DEM-331R (1000Base-BX,TX-1310/RX1550nm, 40km) - DES-1210-28/28P/52: Up to 8K MAC address IGMP snooping: supports 256 multicast group 802.1D Spanning Tree 802.1w Rapid Spanning Tree Loopback Detection 802.3ad Link Aggregation: - DES-1210-52: 17...
Technical Specifications D-Link Web Smart Switch User Manual Appendix B - DES-1210-28P: 9.5Mpps Forwarding Mode: Store and Forward Packet Buffer memory: 256K Bytes DDRII for CPU: 64M Bytes Flash Memory: 16M Bytes Port Functions 8, 24 ... - DES-1210-08P/28/52: 0dB (Fan-less) - IEEE 802.3at (DES-1210-28P only) - DEM-315GT (1000BASE-ZX, 80km) - DEM-331R (1000Base-BX,TX-1310/RX1550nm, 40km) - DES-1210-28/28P/52: Up to 8K MAC address IGMP snooping: supports 256 multicast group 802.1D Spanning Tree 802.1w Rapid Spanning Tree Loopback Detection 802.3ad Link Aggregation: - DES-1210-52: 17...