Cisco WS-X4013 - Supervisor Engine II-Plus-TS Support and Manuals
Get Help and Manuals for this Cisco item
This item is in your list!
View All Support Options Below
Free Cisco WS-X4013 manuals!
Problems with Cisco WS-X4013?
Ask a Question
Free Cisco WS-X4013 manuals!
Problems with Cisco WS-X4013?
Ask a Question
Cisco WS-X4013 Videos
Popular Cisco WS-X4013 Manual Pages
Hardware Maintenance Manual - Page 3
... the Sales or Service Partner, either (i) to provide a correction or a workaround for any installation, handling, maintenance, or operating instructions supplied by the Government is subject to restrictions as set forth in subparagraph (c) of the Commercial Computer Software Restricted Rights clause at DFARS §252.2277013.
This Limited Warranty does not apply to Software which the error...
Hardware Maintenance Manual - Page 4
... that does not contain the defect, or (iii) refund the price paid for the Hardware less depreciation calculated on a straight-line basis. Hardware Remedies. Cisco or the Sales or Service Partner (as set forth in accordance with any installation, handling, maintenance, or operating instructions supplied by Cisco, (3) has been subjected to defective Hardware will be eligible for shipment...
Hardware Maintenance Manual - Page 5
TABLE OF CONTENTS
About This Manual xv Document Objectives xv Audience xv Document Organization xv Document Conventions xvi
Chapter 1 Cisco 4000 Series Overview 1-1 External Differences in Models of the Cisco 4000 Series 1-1 Series Specifications 1-2 Memory Systems 1-4
Chapter 2 Preparing for Installation 2-1 Safety Recommendations 2-2 Safety with Electricity 2-2 Preventing Electrostatic Discharge...
Hardware Maintenance Manual - Page 15
UniverCD is included in your local sales representative or call Customer Service.
Document Objectives
This publication contains the initial site preparation, installation, troubleshooting, and selected upgrade and maintenance procedures. For software configuration information, refer to Ordering Cisco Documentation, which is updated and shipped monthly, so it may be familiar with a DC-...
Hardware Maintenance Manual - Page 16
... Initial Hardware Configuration," includes a troubleshooting
overview, problem-solving instructions, environmental reporting features, and understanding front-panel and network-processor module LED indicators.
• Chapter 5, "Maintaining and Upgrading the Router," includes instructions for opening the
chassis, replacing or adding network processor modules, and replacing single in-line memory...
Hardware Maintenance Manual - Page 37
...
156
256
78
102
31
50
15
Balanced drivers allow EIA/TIA-449 signals to travel a limited distance at any given bit rate; However, you can travel greater distances than those listed. however, the serial module ports support synchronous connections, and the console and auxiliary ports support asynchronous connections.
Preparing for V.35 is 2 Mbps, but...
Hardware Maintenance Manual - Page 43
...set , or if the cable is DCE and the clock rate is not configured. Note that the cables for the two versions are available for the module to a modem, CSU/DSU, or other device as shown in NRZI mode. Nine different serial cables are not interchangeable. An error... cable, available from your customer service representative, is set the jumpers for Installation 2-21
and EIA-530 DTE....
Hardware Maintenance Manual - Page 44
...) Signals All interfaces support both DTE and DCE mode, depending on the mode of error packets, suspect a ...Installation and Maintenance If the DTE device does not return SCTE, you must use the dce-terminal-timing-enable command to configure the DCE port to use a port in DCE mode, the default operation is operating in DCE mode, you must connect a DCE interface cable and set the clock rate...
Hardware Maintenance Manual - Page 51
... when power is turned OFF. (See Figure 2-30 and Figure 2-31.)
Preparing for Installation 2-29
Each BRI port is customer owned. Network hazardous voltages are accessible in North America... the end away from the router first to an Integrated Services Digital Network (ISDN) through an ISDN channel service unit/digital service unit (CSU/DSU) called the NT1. Network Connection Considerations...
Hardware Maintenance Manual - Page 52
...limitation
32.8' (10 m)
32.8' (10 m)
1. Network Connection Considerations
The specifications for the BRI cable are given in Figure 2-32, provides a controller for a remote site.
2-30 Cisco 4000 Series Hardware Installation... and receiving data bidirectionally at the T1 rate of 1.544 Mbps. Channelized T1 Connections
The Cisco 4000 series router supports a channelized T1 (CT1) network processor...
Hardware Maintenance Manual - Page 54
... impedance to the system as stated in Table 2-7. Each virtual channel is set to 120-ohm.
2-32 Cisco 4000 Series Hardware Installation and Maintenance LOOPBACK LOCAL ALARM REMOTE ALARM H3154
Network Connection Considerations
Channelized E1 Connections
The Cisco 4000 series router supports a channelized E1 (CE1) network processor module with capacitive coupling between the receive...
Hardware Maintenance Manual - Page 55
...service personnel only. Figure 2-36
E1 Interface Cable for 75-Ohm, Unbalanced Connections (with the E1 interface and to reduce the potential for injury, jumper J2 should be set to 75-ohm
1. This is a setting... four serial cables are available from Cisco Systems. All three have DB-15 connectors on the CE1end and either impedance option, a jumper installed at J2 bypasses the AC-decoupling ...
Hardware Maintenance Manual - Page 64
...limitation
32.8' (10 m)
32.8' (10 m)
1. The BRI network processor module (see the following section, "BRI Cable Specifications"), connect the Basic Rate Interface (BRI) port to shut down. Each BRI port is an ISDN channel service unit/digital service...customer owned.
3-6 Cisco 4000 Series Hardware Installation and Maintenance Because the BRI module does not support point-to-multipoint ...
Hardware Maintenance Manual - Page 127
... Monitor Program
The ROM monitor diagnostics help you reload the router. If you set the configuration to 0x0, you will have to manually boot the system from the console each time you isolate or rule out hardware problems encountered when installing your router. Timesaver Break (system interrupt) is always enabled for 60 seconds after...
Hardware Maintenance Manual - Page 141
... 4-8 power LED indication 3-22 light 4-3 specifications 1-3 supply features 2-4 system, troubleshooting 4-2 preparing for installation 2-1 to make connections 2-7 preventing ESD damage 2-3 preventive site configuration 2-4 printing summary of ROM monitor commands problem indications 4-3 temperature 4-3 problem solving 4-1 processor specifications 1-3 protocol analyzer, attaching 2-9 publications...