Software Guide
Page 17
... E R 78-15486-01 Configuring a Login Banner 27-4 Clearing the Login Banner 27-5 Enabling or Disabling the "Cisco Systems Console" Telnet Login Banner 27-5 Defining and Using Command Aliases 27-6 Defining and Using IP Aliases 27-7 Configuring...Support 27-12 Power Management 28-1 Understanding How Power Management Works on the Catalyst 4500 Series Switches 28-1 Power Management Overview 28-2 Understanding Power Management Modes 28-2 Available Power for Power Supplies 28-4 Power Management Limitations 28-4 1400 W DC Power Supply Guidelines and Restrictions 28-5 Understanding How Power Management ...
... E R 78-15486-01 Configuring a Login Banner 27-4 Clearing the Login Banner 27-5 Enabling or Disabling the "Cisco Systems Console" Telnet Login Banner 27-5 Defining and Using Command Aliases 27-6 Defining and Using IP Aliases 27-7 Configuring...Support 27-12 Power Management 28-1 Understanding How Power Management Works on the Catalyst 4500 Series Switches 28-1 Power Management Overview 28-2 Understanding Power Management Modes 28-2 Available Power for Power Supplies 28-4 Power Management Limitations 28-4 1400 W DC Power Supply Guidelines and Restrictions 28-5 Understanding How Power Management ...
Software Guide
Page 31
... Series and Catalyst 4500 Series Switches Product Number Catalyst 4000 Series WS-C4003 WS-C4006 Chassis Description Catalyst 4003 • Modular 3-slot chassis • Optional redundant power supplies Catalyst 4006 • Modular 6-slot chassis • 30-Gbps backplane • Two power supplies with optional third power supply 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches...
... Series and Catalyst 4500 Series Switches Product Number Catalyst 4000 Series WS-C4003 WS-C4006 Chassis Description Catalyst 4003 • Modular 3-slot chassis • Optional redundant power supplies Catalyst 4006 • Modular 6-slot chassis • 30-Gbps backplane • Two power supplies with optional third power supply 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches...
Software Guide
Page 32
...and Catalyst 4500 Series Switches (continued) Product Number WS-C4912G Catalyst 4500 Series WS-C4503 WS-C4506 Chassis Description Catalyst 4912G • Fixed-configuration switch • 12-Gbps backplane • Optional redundant power supplies • 12 1000BASE-X (GBIC) Gigabit Ethernet ports Catalyst 4503...2980G Installation Guide. Table 1-2 Catalyst 2948G Switch Product Number WS-C2948G Chassis Description Catalyst 2948G • Fixed-configuration switch • 12-Gbps backplane • Optional redundant power supplies • Two 1000BASE-X (GBIC) Gigabit Ethernet ports •...
...and Catalyst 4500 Series Switches (continued) Product Number WS-C4912G Catalyst 4500 Series WS-C4503 WS-C4506 Chassis Description Catalyst 4912G • Fixed-configuration switch • 12-Gbps backplane • Optional redundant power supplies • 12 1000BASE-X (GBIC) Gigabit Ethernet ports Catalyst 4503...2980G Installation Guide. Table 1-2 Catalyst 2948G Switch Product Number WS-C2948G Chassis Description Catalyst 2948G • Fixed-configuration switch • 12-Gbps backplane • Optional redundant power supplies • Two 1000BASE-X (GBIC) Gigabit Ethernet ports •...
Software Guide
Page 33
... modules and ports on every supervisor engine module or fixed-configuration switch. Table 1-3 Catalyst 2980G Switch Product Number WS-C2980G-A Chassis Description Catalyst 2980G • Fixed-configuration switch • 12-Gbps backplane • Optional redundant power supplies • Two 1000BASE-X (GBIC) Gigabit Ethernet ports • 80 10/100BASE-TX Fast Ethernet ports Supervisor Engine...
... modules and ports on every supervisor engine module or fixed-configuration switch. Table 1-3 Catalyst 2980G Switch Product Number WS-C2980G-A Chassis Description Catalyst 2980G • Fixed-configuration switch • 12-Gbps backplane • Optional redundant power supplies • Two 1000BASE-X (GBIC) Gigabit Ethernet ports • 80 10/100BASE-TX Fast Ethernet ports Supervisor Engine...
Software Guide
Page 373
... on your NMS must match at an agent. When a port or module goes up or down - When temperature limitations are spanning tree topology changes - When power supply errors occur • SNMP community strings-SNMP community strings authenticate access to community strings - When there are managed devices that value. • Setting a MIB variable...
... on your NMS must match at an agent. When a port or module goes up or down - When temperature limitations are spanning tree topology changes - When power supply errors occur • SNMP community strings-SNMP community strings authenticate access to community strings - When there are managed devices that value. • Setting a MIB variable...
Software Guide
Page 412
... and display the current date and time: Console> (enable) set time Fri 06/15/01 12:30:00 Fri Jun 15 2001, 12:30:00 Console> (enable) show time Fri Jun 15 2001, 12:30:02 Console> (enable) Creating a Login Banner You can configure the switch to the switch...press Return. Setting the System Clock Chapter 27 Administering the Switch disable 9600 0% 0% Wed Apr 24 2002, 15:46:01 Power Capacity of the Chassis:2 supplies WARNING:Power supplies of different values have been inserted System Name System Location System Contact CC Sunnyvale CA [email protected] 4006 Console> (enable) ...
... and display the current date and time: Console> (enable) set time Fri 06/15/01 12:30:00 Fri Jun 15 2001, 12:30:00 Console> (enable) show time Fri Jun 15 2001, 12:30:02 Console> (enable) Creating a Login Banner You can configure the switch to the switch...press Return. Setting the System Clock Chapter 27 Administering the Switch disable 9600 0% 0% Wed Apr 24 2002, 15:46:01 Power Capacity of the Chassis:2 supplies WARNING:Power supplies of different values have been inserted System Name System Location System Contact CC Sunnyvale CA [email protected] 4006 Console> (enable) ...
Software Guide
Page 422
...: - 1300 W AC - 1400 W DC For more information on available wattage for the Catalyst 4500 series switches. Both power supplies must have power redundancy. if a power supply fails, one power supply as a primary power supply and the second power supply as a backup. If the primary power supply fails, the second power supply supports the switch without disrupting the network. For example, if your switch has two...
...: - 1300 W AC - 1400 W DC For more information on available wattage for the Catalyst 4500 series switches. Both power supplies must have power redundancy. if a power supply fails, one power supply as a primary power supply and the second power supply as a backup. If the primary power supply fails, the second power supply supports the switch without disrupting the network. For example, if your switch has two...
Software Guide
Page 423
... power supply in power supply bay 1 (PS1) and ignores the power supply in power supply bay (PS2). Your switch will not have power redundancy. • When using fixed power supplies, choose a power supply that can seriously damage your switch. • If you use power supplies with different types or wattages in your switch continues to operate in combined mode. • When using variable power supplies, choose a power supply that supplies...
... power supply in power supply bay 1 (PS1) and ignores the power supply in power supply bay (PS2). Your switch will not have power redundancy. • When using fixed power supplies, choose a power supply that can seriously damage your switch. • If you use power supplies with different types or wattages in your switch continues to operate in combined mode. • When using variable power supplies, choose a power supply that supplies...
Software Guide
Page 424
... that your system has enough power, add the power that is provided by the power supplies. • If you insert a single power supply into the switch and then set the power requirements for the installed modules to exceed the power that is consumed by the power supplies for the Catalyst 4500 series switches. The 1400 W DC power supply has 0.75 efficiency. For...
... that your system has enough power, add the power that is provided by the power supplies. • If you insert a single power supply into the switch and then set the power requirements for the installed modules to exceed the power that is consumed by the power supplies for the Catalyst 4500 series switches. The 1400 W DC power supply has 0.75 efficiency. For...
Software Guide
Page 425
...-term emergency, because you can seriously damage your switch. • The 1400 W DC power supply works with your switch. If the power supply fan fails, the display shows the power as it is tied to the Catalyst 4500 Series, Catalyst 2948G, and Catalyst 2980G Switches Command... has been inserted and Insufficient power supplies operating. • If you power down . The power supply fan status is installed in the chassis. 1400 W DC Power Supply Guidelines and Restrictions This section describes the guidelines and restrictions for using a 1400 W DC power supply in the Catalyst 4500 series...
...-term emergency, because you can seriously damage your switch. • The 1400 W DC power supply works with your switch. If the power supply fan fails, the display shows the power as it is tied to the Catalyst 4500 Series, Catalyst 2948G, and Catalyst 2980G Switches Command... has been inserted and Insufficient power supplies operating. • If you power down . The power supply fan status is installed in the chassis. 1400 W DC Power Supply Guidelines and Restrictions This section describes the guidelines and restrictions for using a 1400 W DC power supply in the Catalyst 4500 series...
Software Guide
Page 426
...-RJ21 modules • One Catalyst 4006 chassis with a WS-X4013 supervisor engine with two 650 W power supplies (in 1+1 redundancy mode (one primary plus one slot of the chassis empty. In those configurations, redundancy requires three power supplies. You can create redundancy with redundant power supplies, both power supplies should have different power requirements; The total load for up to leave...
...-RJ21 modules • One Catalyst 4006 chassis with a WS-X4013 supervisor engine with two 650 W power supplies (in 1+1 redundancy mode (one primary plus one slot of the chassis empty. In those configurations, redundancy requires three power supplies. You can create redundancy with redundant power supplies, both power supplies should have different power requirements; The total load for up to leave...
Software Guide
Page 427
..., the type and number of your switch. • A module in the chassis (at boot up the power that require more power than the single power supply provides, the switch places the newly inserted module into reset mode. 78-15486-01 Catalyst 4500 Series, Catalyst ...When considering the 1+1 redundancy mode, you have more power than a single power supply can handle, the switch displays this message: Module has been inserted and Insufficient power supplies operating. Enter the set power budget 1 command to set the power budget to the default 2+1 redundancy configuration by the supervisor...
..., the type and number of your switch. • A module in the chassis (at boot up the power that require more power than the single power supply provides, the switch places the newly inserted module into reset mode. 78-15486-01 Catalyst 4500 Series, Catalyst ...When considering the 1+1 redundancy mode, you have more power than a single power supply can handle, the switch displays this message: Module has been inserted and Insufficient power supplies operating. Enter the set power budget 1 command to set the power budget to the default 2+1 redundancy configuration by the supervisor...
Software Guide
Page 428
...time to 2+1 redundancy mode. It requires 735 W and cannot be used in 1+1 redundancy mode for either a 400 W or 650 W power supply. • WS-X4013 supervisor engine-110 W • Five 48-port 100BASE-FX modules in reset mode. The switch reactivates only the modules that it is ..., the switch tries to stabilize the chassis' power usage. You must remove the failed 400 W power supply so that are placed into service; The evaluation process may require several cycles to resolve this configuration. • WS-X4013 supervisor engine-110 W • Two WS-X4148-RJ modules in slots 2 and 3-65...
...time to 2+1 redundancy mode. It requires 735 W and cannot be used in 1+1 redundancy mode for either a 400 W or 650 W power supply. • WS-X4013 supervisor engine-110 W • Five 48-port 100BASE-FX modules in reset mode. The switch reactivates only the modules that it is ..., the switch tries to stabilize the chassis' power usage. You must remove the failed 400 W power supply so that are placed into service; The evaluation process may require several cycles to resolve this configuration. • WS-X4013 supervisor engine-110 W • Two WS-X4148-RJ modules in slots 2 and 3-65...
Software Guide
Page 431
...phone is connected to the switch port, the switch cannot power the second phone. Table 28-3 Switch Components Supporting Inline Power Switch Chassis Catalyst 4006 Catalyst 4503 Catalyst 4506 Modules WS-X4148-RJ45V WS-X4148-RJ45V Power Supplies Catalyst 4000 Series Power Entry Module (PEM) 1300 W AC 2800 W AC... 1400 W DC You can also be connected to an AC power source and supply its own power to the voice circuit. You can utilize inline power. If you ...
...phone is connected to the switch port, the switch cannot power the second phone. Table 28-3 Switch Components Supporting Inline Power Switch Chassis Catalyst 4006 Catalyst 4503 Catalyst 4506 Modules WS-X4148-RJ45V WS-X4148-RJ45V Power Supplies Catalyst 4000 Series Power Entry Module (PEM) 1300 W AC 2800 W AC... 1400 W DC You can also be connected to an AC power source and supply its own power to the voice circuit. You can utilize inline power. If you ...
Software Guide
Page 435
... 2 31.00 836.00 15.400 3 31.00 836.00 15.400 DC Power supplies are configured for 2500Watts DC input Power Budget is : 2 supplies Power Available to combined mode. Chapter 28 Power Management Configuring Power Management This example shows how to set the power management mode to redundant: Console>(enable) set combined mode on the Catalyst 4500...
... 2 31.00 836.00 15.400 3 31.00 836.00 15.400 DC Power supplies are configured for 2500Watts DC input Power Budget is : 2 supplies Power Available to combined mode. Chapter 28 Power Management Configuring Power Management This example shows how to set the power management mode to redundant: Console>(enable) set combined mode on the Catalyst 4500...
Software Guide
Page 436
... power usage for the 1400 W DC power supply. Verify the configuration. Command set power budget {1 | 2} show enviroment power Total Inline Power Available: 4166.00 Watts (83.32 Amps @50V) Total Inline Power Drawn From the System: 0 Watt Remaining Inline Power in the System: 4166.00 Watts (83.32 Amps @50V) Configured Default Inline Power allocation per port: 6.00 Watts (0.12...
... power usage for the 1400 W DC power supply. Verify the configuration. Command set power budget {1 | 2} show enviroment power Total Inline Power Available: 4166.00 Watts (83.32 Amps @50V) Total Inline Power Drawn From the System: 0 Watt Remaining Inline Power in the System: 4166.00 Watts (83.32 Amps @50V) Configured Default Inline Power allocation per port: 6.00 Watts (0.12...
Software Guide
Page 437
... Do you want to display the output for the switch: Console> (enable) set power budget 1 Warning: Your power supply budget will be constrained to the power available from the System (excluding voice power):265 Watts (22.01 Amps @12V) Remaining Power (excluding voice power):485 Watts (40.05 Amps @12V) Console> (enable) Displaying System Information To display...
... Do you want to display the output for the switch: Console> (enable) set power budget 1 Warning: Your power supply budget will be constrained to the power available from the System (excluding voice power):265 Watts (22.01 Amps @12V) Remaining Power (excluding voice power):485 Watts (40.05 Amps @12V) Console> (enable) Displaying System Information To display...
Software Guide
Page 438
... Guide-Release 8.1 78-15486-01 clear config all Load the saved configuration. configure bootflash:switch.cfg If you have only one power supply in privileged mode: Task Set the power mode of a port or group of ports, perform this task: Step 1 Step 2 Step 3 Step 4 Step 5 Step...Task Command Change the nondefault configuration mode to set the power budget to 2. Configuring Inline Power These sections show how to write memory NVRAM. Command set the power budget to use at boot up. If you have two power supplies, set config mode text bootflash:switch.cfg text and ...
... Guide-Release 8.1 78-15486-01 clear config all Load the saved configuration. configure bootflash:switch.cfg If you have only one power supply in privileged mode: Task Set the power mode of a port or group of ports, perform this task: Step 1 Step 2 Step 3 Step 4 Step 5 Step...Task Command Change the nondefault configuration mode to set the power budget to 2. Configuring Inline Power These sections show how to write memory NVRAM. Command set the power budget to use at boot up. If you have two power supplies, set config mode text bootflash:switch.cfg text and ...
Software Guide
Page 441
...IEEE 802.3af compliance • Cisco CallManager release 3.0 or later releases • If you want to utilize inline power, Table 29-1 lists the Catalyst 4500 series components that support inline power. • If you do not want to utilize inline power, then you can only provide ... releases for the Catalyst 4500 series switches. Table 29-1 Catalyst 4500 Series Components Supporting Inline Power Switch Chassis Catalyst 4006 Catalyst 4503 Catalyst 4506 Modules WS-X4148-RJ45V1 WS-X4148-RJ45V Power Supplies Catalyst 4000 Family Power Entry Module (PEM) 1300 W AC 2800 W AC 1400 W DC 1.
...IEEE 802.3af compliance • Cisco CallManager release 3.0 or later releases • If you want to utilize inline power, Table 29-1 lists the Catalyst 4500 series components that support inline power. • If you do not want to utilize inline power, then you can only provide ... releases for the Catalyst 4500 series switches. Table 29-1 Catalyst 4500 Series Components Supporting Inline Power Switch Chassis Catalyst 4006 Catalyst 4503 Catalyst 4506 Modules WS-X4148-RJ45V1 WS-X4148-RJ45V Power Supplies Catalyst 4000 Family Power Entry Module (PEM) 1300 W AC 2800 W AC 1400 W DC 1.
Software Guide
Page 593
... 30-43 authorized ports with 802.1X 31-4 autonegotiation duplex 4-5 speed 4-5 trunks 11-2 auxiliary VLANs configuring 10-13 dynamic VLAN membership 12-14 software support 10-5 B BackboneFast adding a switch (figure) 8-7 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches...audience xxiii authentication See 802.1x authentication, Kerberos authentication; RADIUS authentication; INDEX Numerics 10/100 port speed, setting 4-4 1400W DC power supply 28-5 802.1Q example 11-9, 11-19 mapping VLANs to ISL 10-11 overview 11-1 restrictions 11-4 supported switches (table)...
... 30-43 authorized ports with 802.1X 31-4 autonegotiation duplex 4-5 speed 4-5 trunks 11-2 auxiliary VLANs configuring 10-13 dynamic VLAN membership 12-14 software support 10-5 B BackboneFast adding a switch (figure) 8-7 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches...audience xxiii authentication See 802.1x authentication, Kerberos authentication; RADIUS authentication; INDEX Numerics 10/100 port speed, setting 4-4 1400W DC power supply 28-5 802.1Q example 11-9, 11-19 mapping VLANs to ISL 10-11 overview 11-1 restrictions 11-4 supported switches (table)...