... replacement parts. A double insulated product is provided with the words «DOUBLE INSULATION» or «DOUBLE INSULATED». BERNINA is intended for household use outdoors. 13. It may also be done by qualified service personnel. No responsibility will be taken for...position then remove the plug from the electrical outlet when removing covers, lubricating or when making any opening. 12. Before disconnecting, turn all controls to the national directive. See instructions for grounding be identical to break. 9. In a double-insulated product, two systems...
... replacement parts. A double insulated product is provided with the words «DOUBLE INSULATION» or «DOUBLE INSULATED». BERNINA is intended for household use outdoors. 13. It may also be done by qualified service personnel. No responsibility will be taken for...position then remove the plug from the electrical outlet when removing covers, lubricating or when making any opening. 12. Before disconnecting, turn all controls to the national directive. See instructions for grounding be identical to break. 9. In a double-insulated product, two systems...
User Guide
Page 10
10 Setting up the sewing computer Winding the bobbin Winding the bobbin • turn power switch on • place empty bobbin on spindle • following the direction of the arrow take thread through the rear guide and round the ...
10 Setting up the sewing computer Winding the bobbin Winding the bobbin • turn power switch on • place empty bobbin on spindle • following the direction of the arrow take thread through the rear guide and round the ...
User Guide
Page 11
Bobbin case Setting up the sewing computer 11 A To remove the bobbin case • raise the needle • turn power switch to «0» • open the bobbin cover • grasp the latch of the bobbin case • remove case To insert the bobbin ...
Bobbin case Setting up the sewing computer 11 A To remove the bobbin case • raise the needle • turn power switch to «0» • open the bobbin cover • grasp the latch of the bobbin case • remove case To insert the bobbin ...
User Guide
Page 12
... when thread is pulled. it will go • tighten the needle clamp screw 032622.50.04_0701_a210_EN ... The bobbin must turn power switch to «0» • lower the presser foot • loosen the needle clamp screw • pull the needle down to remove Inserting the ...
... when thread is pulled. it will go • tighten the needle clamp screw 032622.50.04_0701_a210_EN ... The bobbin must turn power switch to «0» • lower the presser foot • loosen the needle clamp screw • pull the needle down to remove Inserting the ...
User Guide
Page 13
... the presser foot sole Setting up the sewing computer 13 3 Changing the presser foot sole • raise the needle and the presser foot shaft • turn power switch to «0» • press the button on the back of the shaft • lower the presser foot lifter and the foot sole...
... the presser foot sole Setting up the sewing computer 13 3 Changing the presser foot sole • raise the needle and the presser foot shaft • turn power switch to «0» • press the button on the back of the shaft • lower the presser foot lifter and the foot sole...
User Guide
Page 17
... thread tension too loose • the upper thread is pulled more to the right side of the fabric • to increase the upper thread tension turn ten- sion adjustment wheel to suit the fabric and chosen stitch. If other sewing or embroidery threads are used to set for special sewing work... thread tension too tight • the lower thread is pulled more to the wrong side of the fabric • to reduce the upper thread tension turn ten- Metrosene 100/2 (Arova Mettler, Switzerland) is used , the tension may need adjusting for normal sewing work • for the best results.
... thread tension too loose • the upper thread is pulled more to the right side of the fabric • to increase the upper thread tension turn ten- sion adjustment wheel to suit the fabric and chosen stitch. If other sewing or embroidery threads are used to set for special sewing work... thread tension too tight • the lower thread is pulled more to the wrong side of the fabric • to reduce the upper thread tension turn ten- Metrosene 100/2 (Arova Mettler, Switzerland) is used , the tension may need adjusting for normal sewing work • for the best results.
User Guide
Page 31
...Cleaning the LCD display and the sewing computer • wipe with a cloth or brush, never use a sharp instrument • replace the hook, turning the handwheel if necessary so that the hook driver is stored in a cold room, it should be brought to a warm room about one hour ...lever to the left • close the hook race cover and secure with the locking lever, the locking pin must engage • check by turning the handwheel • insert the bobbin case Lubricating • squeeze 2-3 drops of solvent to the safety instruction! 032622.50.04_0701_a210_EN Cleaning Maintenance 31...
...Cleaning the LCD display and the sewing computer • wipe with a cloth or brush, never use a sharp instrument • replace the hook, turning the handwheel if necessary so that the hook driver is stored in a cold room, it should be brought to a warm room about one hour ...lever to the left • close the hook race cover and secure with the locking lever, the locking pin must engage • check by turning the handwheel • insert the bobbin case Lubricating • squeeze 2-3 drops of solvent to the safety instruction! 032622.50.04_0701_a210_EN Cleaning Maintenance 31...
User Guide
Page 32
Light bulbs get hot. Please refer to cool down before cleaning and servicing Note: Use bulb type 12 V 5 W. 32 Maintenance Sewing light Replacing the bulb • turn power switch to «0» • loosen the screw • remove the cover by lifting it slightliy and detaching from the top • remove the bulb • insert the new bulb • replace cover and tighten screw CAUTION Disconnect plug from the socket before removal. Allow to the safety instruction! 032622.50.04_0701_a210_EN W 2.1 x 9.5 d.
Light bulbs get hot. Please refer to cool down before cleaning and servicing Note: Use bulb type 12 V 5 W. 32 Maintenance Sewing light Replacing the bulb • turn power switch to «0» • loosen the screw • remove the cover by lifting it slightliy and detaching from the top • remove the bulb • insert the new bulb • replace cover and tighten screw CAUTION Disconnect plug from the socket before removal. Allow to the safety instruction! 032622.50.04_0701_a210_EN W 2.1 x 9.5 d.