Page 12
... Contents 3.1.1 Mini-GBIC Slots ...41 3.1.2 Console Port ...43 3.1.3 Signal Slot ...43 3.2 Rear Panel ...46 3.2.1 Removing and Installing the Fan Module 47 3.2.2 Uplink Module ...48 3.2.3 Rear Panel Connections 48 3.2.4 Management Port ...49 3.2.5 Power Connector ...49 3.3 Power Connection ...49 3.3.1 AC Power Connections 50 3.3.2 DC Power Connections 50 3.3.3 Procedure to Turn on the Switch Power... ...71 6.1 How to Use DHCP Snooping on the Switch 71 6.2 How to Use DHCP Relay on the Switch 75 6.2.1 DHCP Relay Tutorial Introduction 75 12 XGS4700-48F User's Guide
... Contents 3.1.1 Mini-GBIC Slots ...41 3.1.2 Console Port ...43 3.1.3 Signal Slot ...43 3.2 Rear Panel ...46 3.2.1 Removing and Installing the Fan Module 47 3.2.2 Uplink Module ...48 3.2.3 Rear Panel Connections 48 3.2.4 Management Port ...49 3.2.5 Power Connector ...49 3.3 Power Connection ...49 3.3.1 AC Power Connections 50 3.3.2 DC Power Connections 50 3.3.3 Procedure to Turn on the Switch Power... ...71 6.1 How to Use DHCP Snooping on the Switch 71 6.2 How to Use DHCP Relay on the Switch 75 6.2.1 DHCP Relay Tutorial Introduction 75 12 XGS4700-48F User's Guide
User Guide
Page 22
...Setup ...424 47.3 Syslog Server Setup ...425 Chapter 48 Cluster Management...427 48.1 Clustering Management Status Overview 427 48.2 Cluster Management Status 428 48.2.1 Cluster Member Switch Management 429 48.3 Clustering Management Configuration 432 Chapter 49 MAC Table...435 ...49.1 MAC Table Overview ...435 49.2 Viewing the MAC Table ...436 Chapter 50 IP Table ...439 50.1 IP Table Overview ...439 50.2 Viewing the IP Table ...440 Chapter 51 ARP Table ...443 22 XGS4700-48F...
...Setup ...424 47.3 Syslog Server Setup ...425 Chapter 48 Cluster Management...427 48.1 Clustering Management Status Overview 427 48.2 Cluster Management Status 428 48.2.1 Cluster Member Switch Management 429 48.3 Clustering Management Configuration 432 Chapter 49 MAC Table...435 ...49.1 MAC Table Overview ...435 49.2 Viewing the MAC Table ...436 Chapter 50 IP Table ...439 50.1 IP Table Overview ...439 50.2 Viewing the IP Table ...440 Chapter 51 ARP Table ...443 22 XGS4700-48F...
User Guide
Page 27
It can also operate together with 48 mini-GBIC slots for SFP transceivers, two power slots for hot-swappable DCP4700-48F or ACP4700-48F power modules and one single IP address. In addition, the Switch can alleviate bandwidth contention and eliminate server and network bottlenecks. It ... module requires DC power supply input of -36 VDC to 240 VAC, 1.4 A power. All users that need high bandwidth can provide a XGS4700-48F User's Guide 27 By integrating router functions, the Switch performs wire-speed layer-3 routing in web configurator, managing and configuring the Switch is a ...
It can also operate together with 48 mini-GBIC slots for SFP transceivers, two power slots for hot-swappable DCP4700-48F or ACP4700-48F power modules and one single IP address. In addition, the Switch can alleviate bandwidth contention and eliminate server and network bottlenecks. It ... module requires DC power supply input of -36 VDC to 240 VAC, 1.4 A power. All users that need high bandwidth can provide a XGS4700-48F User's Guide 27 By integrating router functions, the Switch performs wire-speed layer-3 routing in web configurator, managing and configuring the Switch is a ...
User Guide
Page 41
...48 Mini-GBIC Slots Console Port Signal DESCRIPTION Use Small Form-Factor Pluggable (SFP) transceivers in these ports for fiber-optic or copper connections to a signal input terminal on other pieces of equipment. The Switch does not come with the Small Form- Figure 9 Front Panel The following table describes the ports. XGS4700-48F.... Use a transceiver to connect a fiber-optic cable to signal output terminals on another piece of equipment. 3.1.1 Mini-GBIC Slots These are 48 slots for Small Form-Factor Pluggable (SFP) transceivers. Connect the signal input pins to the Switch.
...48 Mini-GBIC Slots Console Port Signal DESCRIPTION Use Small Form-Factor Pluggable (SFP) transceivers in these ports for fiber-optic or copper connections to a signal input terminal on other pieces of equipment. The Switch does not come with the Small Form- Figure 9 Front Panel The following table describes the ports. XGS4700-48F.... Use a transceiver to connect a fiber-optic cable to signal output terminals on another piece of equipment. 3.1.1 Mini-GBIC Slots These are 48 slots for Small Form-Factor Pluggable (SFP) transceivers. Connect the signal input pins to the Switch.
User Guide
Page 48
... in the optional uplink module slot(s) (B and/or C in the figure above). See Section 3.1.1.1 on page 42 and Section 3.1.1.2 on page 42 for more information. 48 XGS4700-48F User's Guide Figure 21 Installing the Fan Module 5 Tighten the thumbscrew. 3.2.2 Uplink Module The following table describes the ports on installing and removing transceivers. •...
... in the optional uplink module slot(s) (B and/or C in the figure above). See Section 3.1.1.1 on page 42 and Section 3.1.1.2 on page 42 for more information. 48 XGS4700-48F User's Guide Figure 21 Installing the Fan Module 5 Tighten the thumbscrew. 3.2.2 Uplink Module The following table describes the ports on installing and removing transceivers. •...
User Guide
Page 53
... through an uplink module in SLOT 2. The Switch is connected to other switches through an uplink module in SLOT 2. XGS4700-48F User's Guide 53 Chapter 3 Hardware Overview Table 3 LEDs (continued) LED COLO R STATUS 1-48 Green Blinking On Amber Blinking On Off 10G 49-50 Blue On Off 51-52 Blue On Off DESCRIPTION...
... through an uplink module in SLOT 2. The Switch is connected to other switches through an uplink module in SLOT 2. XGS4700-48F User's Guide 53 Chapter 3 Hardware Overview Table 3 LEDs (continued) LED COLO R STATUS 1-48 Green Blinking On Amber Blinking On Off 10G 49-50 Blue On Off 51-52 Blue On Off DESCRIPTION...
User Guide
Page 128
....16.1.0/24, video for 192.168.1.0/24 and data for 10.1.1.0/24. Figure 48 Subnet Based VLAN Application Example Tagged Frames Internet Untagged Frames 172.16.1.0/24 VID = 100 192.168.1.0/24 VID = 200 10.1.1.0/24 VID = 300 128 XGS4700-48F User's Guide For example, an ISP (Internet Service Provider) may divide different...
....16.1.0/24, video for 192.168.1.0/24 and data for 10.1.1.0/24. Figure 48 Subnet Based VLAN Application Example Tagged Frames Internet Untagged Frames 172.16.1.0/24 VID = 100 192.168.1.0/24 VID = 200 10.1.1.0/24 VID = 300 128 XGS4700-48F User's Guide For example, an ISP (Internet Service Provider) may divide different...
User Guide
Page 202
Table 48 Advanced Application > Port Security > VLAN MAC Address Limit LABEL DESCRIPTION Active Select this feature is from "0" to "16384". For example, if you set in a specified ... maximum number of the port to which the port belongs. Chapter 19 Port Security The following table describes the labels in the Delete column. 202 XGS4700-48F User's Guide Limit Number This is applied. Delete Check the rule(s) that may access port 2 at any one of the rule.
Table 48 Advanced Application > Port Security > VLAN MAC Address Limit LABEL DESCRIPTION Active Select this feature is from "0" to "16384". For example, if you set in a specified ... maximum number of the port to which the port belongs. Chapter 19 Port Security The following table describes the labels in the Delete column. 202 XGS4700-48F User's Guide Limit Number This is applied. Delete Check the rule(s) that may access port 2 at any one of the rule.
User Guide
Page 222
Chapter 23 VLAN Stacking distinguish customer A and tag 48 to a customer can be added. All VLANs belonging to distinguish customer B at edge device 1 and then stripping those tags at the edge of the service ... choose Normal or Access Port. • Select Tunnel Port (available for Gigabit ports only) for ingress ports on a port where you choose Tunnel Port. 222 XGS4700-48F User's Guide Figure 99 VLAN Stacking Example 23.2 VLAN Stacking Port Roles Each port can have three VLAN stacking "roles", Normal, Access Port and Tunnel...
Chapter 23 VLAN Stacking distinguish customer A and tag 48 to a customer can be added. All VLANs belonging to distinguish customer B at edge device 1 and then stripping those tags at the edge of the service ... choose Normal or Access Port. • Select Tunnel Port (available for Gigabit ports only) for ingress ports on a port where you choose Tunnel Port. 222 XGS4700-48F User's Guide Figure 99 VLAN Stacking Example 23.2 VLAN Stacking Port Roles Each port can have three VLAN stacking "roles", Normal, Access Port and Tunnel...
User Guide
Page 357
... are done configuring. Table 127 Default DSCP-IEEE 802.1p Mapping DSCP VALUE 0 - 7 8 - 15 16 - 23 24 - 31 32 - 39 40 - 47 48 - 55 56 - 63 IEEE 802.1p 0 1 2 3 4 5 6 7 XGS4700-48F User's Guide 357 DSCP Use this screen afresh. 39.4 DSCP-to-IEEE 802.1p Priority Settings You can configure the DSCP to...
... are done configuring. Table 127 Default DSCP-IEEE 802.1p Mapping DSCP VALUE 0 - 7 8 - 15 16 - 23 24 - 31 32 - 39 40 - 47 48 - 55 56 - 63 IEEE 802.1p 0 1 2 3 4 5 6 7 XGS4700-48F User's Guide 357 DSCP Use this screen afresh. 39.4 DSCP-to-IEEE 802.1p Priority Settings You can configure the DSCP to...
User Guide
Page 379
... all ones in the ARP Table and if it finds the address, it sends it to the device. In an Ethernet LAN, MAC addresses are 48 bits long. If no entry is found for the IP address, ARP broadcasts the request to the MAC address that knows the way) replaces the... target MAC field (FF.FF.FF.FF.FF.FF is the Ethernet broadcast address). In addition, the Switch puts all the devices on the LAN. XGS4700-48F User's Guide 379 The replying device (which is either the IP address of the target in the target IP address field. The ARP Table maintains...
... all ones in the ARP Table and if it finds the address, it sends it to the device. In an Ethernet LAN, MAC addresses are 48 bits long. If no entry is found for the IP address, ARP broadcasts the request to the MAC address that knows the way) replaces the... target MAC field (FF.FF.FF.FF.FF.FF is the Ethernet broadcast address). In addition, the Switch puts all the devices on the LAN. XGS4700-48F User's Guide 379 The replying device (which is either the IP address of the target in the target IP address field. The ARP Table maintains...
User Guide
Page 427
...Management This chapter introduces cluster management. 48.1 Clustering Management Status Overview Cluster Management allows you to communicate with ZyXEL cluster management implementation. Table 160 ZyXEL Clustering Management Specifications Maximum number of ...cluster 24 members Cluster Member Models Cluster member models must be directly connected and be in the same VLAN group so as to be compatible with one Switch, called the cluster manager. XGS4700-48F...
...Management This chapter introduces cluster management. 48.1 Clustering Management Status Overview Cluster Management allows you to communicate with ZyXEL cluster management implementation. Table 160 ZyXEL Clustering Management Specifications Maximum number of ...cluster 24 members Cluster Member Models Cluster member models must be directly connected and be in the same VLAN group so as to be compatible with one Switch, called the cluster manager. XGS4700-48F...
User Guide
Page 428
Note: A cluster can only have one manager. Figure 241 Management > Cluster Management 428 XGS4700-48F User's Guide Figure 240 Clustering Application Example 48.2 Cluster Management Status Click Management > Cluster Management in the basement is the cluster manager and the other switches on the upper floors of the building are cluster members. Chapter 48 Cluster Management In the following example, switch A in the navigation panel to display the following screen.
Note: A cluster can only have one manager. Figure 241 Management > Cluster Management 428 XGS4700-48F User's Guide Figure 240 Clustering Application Example 48.2 Cluster Management Status Click Management > Cluster Management in the basement is the cluster manager and the other switches on the upper floors of the building are cluster members. Chapter 48 Cluster Management In the following example, switch A in the navigation panel to display the following screen.
User Guide
Page 429
... Status None (neither a manager nor a member of switches that cluster member switch's web configurator home page. This cluster member web XGS4700-48F User's Guide 429 Table 161 Management > Cluster Management LABEL Status DESCRIPTION This field displays the role of members to go to the ... cluster member switch's hardware MAC address. Offline shows approximately 1.5 minutes after the link between cluster member and manager goes down) 48.2.1 Cluster Member Switch Management Go to the Clustering Management Status screen of the cluster manager switch and then select an Index hyperlink ...
... Status None (neither a manager nor a member of switches that cluster member switch's web configurator home page. This cluster member web XGS4700-48F User's Guide 429 Table 161 Management > Cluster Management LABEL Status DESCRIPTION This field displays the role of members to go to the ... cluster member switch's hardware MAC address. Offline shows approximately 1.5 minutes after the link between cluster member and manager goes down) 48.2.1 Cluster Member Switch Management Go to the Clustering Management Status screen of the cluster manager switch and then select an Index hyperlink ...
User Guide
Page 430
Chapter 48 Cluster Management configurator home page and the home page that you'd see if you accessed it directly are different. Figure 242 Cluster Management: Cluster Member Web Configurator Screen EXAMPLE EXAMPLE 430 XGS4700-48F User's Guide
Chapter 48 Cluster Management configurator home page and the home page that you'd see if you accessed it directly are different. Figure 242 Cluster Management: Cluster Member Web Configurator Screen EXAMPLE EXAMPLE 430 XGS4700-48F User's Guide
User Guide
Page 431
...switch's configuration file name as seen in the cluster manager switch. ftp> The following example. Table 162 FTP Upload to the cluster member switch. XGS4700-48F User's Guide 431 Figure 243 Example: Uploading Firmware to a Cluster Member Switch C:\>ftp 192.168.1.1 Connected to 192.168.1.1. 220 Switch FTP ...STOR fw-00-a0-c5-01-23-46 226 File received OK ftp: 262144 bytes sent in 0.63Seconds 415.44Kbytes/sec. Chapter 48 Cluster Management 48.2.1.1 Uploading Firmware to a Cluster Member Switch You can use FTP to upload firmware to a cluster member switch through the cluster manager...
...switch's configuration file name as seen in the cluster manager switch. ftp> The following example. Table 162 FTP Upload to the cluster member switch. XGS4700-48F User's Guide 431 Figure 243 Example: Uploading Firmware to a Cluster Member Switch C:\>ftp 192.168.1.1 Connected to 192.168.1.1. 220 Switch FTP ...STOR fw-00-a0-c5-01-23-46 226 File received OK ftp: 262144 bytes sent in 0.63Seconds 415.44Kbytes/sec. Chapter 48 Cluster Management 48.2.1.1 Uploading Firmware to a Cluster Member Switch You can use FTP to upload firmware to a cluster member switch through the cluster manager...
User Guide
Page 432
...Manager is displayed as Error in the Cluster Management Status screen appears in the member summary list below. Chapter 48 Cluster Management 48.3 Clustering Management Configuration Use this screen to be cluster managers will not be directly connected and in the same...163 Management > Clustering Management > Configuration LABEL Clustering Manager DESCRIPTION Active Select Active to display the next screen. based VLAN. 432 XGS4700-48F User's Guide Click Configuration from the Cluster Management screen to have one manager. Switches that was previously a cluster member is later...
...Manager is displayed as Error in the Cluster Management Status screen appears in the member summary list below. Chapter 48 Cluster Management 48.3 Clustering Management Configuration Use this screen to be cluster managers will not be directly connected and in the same...163 Management > Clustering Management > Configuration LABEL Clustering Manager DESCRIPTION Active Select Active to display the next screen. based VLAN. 432 XGS4700-48F User's Guide Click Configuration from the Cluster Management screen to have one manager. Switches that was previously a cluster member is later...
User Guide
Page 433
... members. The Switch loses these changes if it is displayed as Error in the Clustering Candidate list and then enter its web configurator password. Chapter 48 Cluster Management Table 163 Management > Clustering Management > Configuration (continued) LABEL Apply Cancel Clustering Candidate List Password DESCRIPTION Click Apply to save your changes to the..., so use the Save link on the top navigation panel to save your changes to begin configuring this screen afresh. Remove Select this screen afresh. XGS4700-48F User's Guide 433
... members. The Switch loses these changes if it is displayed as Error in the Clustering Candidate list and then enter its web configurator password. Chapter 48 Cluster Management Table 163 Management > Clustering Management > Configuration (continued) LABEL Apply Cancel Clustering Candidate List Password DESCRIPTION Click Apply to save your changes to the..., so use the Save link on the top navigation panel to save your changes to begin configuring this screen afresh. Remove Select this screen afresh. XGS4700-48F User's Guide 433
User Guide
Page 443
In an Ethernet LAN, MAC addresses are 48 bits long. ARP updates the ARP Table for future reference and then sends the packet to the requesting machine. XGS4700-48F User's Guide 443 The replying device (which is either the IP address of the target in the target MAC field (FF.FF.FF.FF.FF...
In an Ethernet LAN, MAC addresses are 48 bits long. ARP updates the ARP Table for future reference and then sends the packet to the requesting machine. XGS4700-48F User's Guide 443 The replying device (which is either the IP address of the target in the target MAC field (FF.FF.FF.FF.FF...
User Guide
Page 455
... RS-232 console port Main switch: PWR1, PWR2, SYS, ALM The 100Base-T management port: MGMT Green: 10 Mbps Amber: 100 Mbps Per mini-GBIC port: 1~48 Operating Environment Storage Environment steady: link state blinking: transmitting/receiving Per stacking port: 49~52 Temperature: 0º C ~ 45º C (32º F ~ ... C (-13º F ~ 158º F) Ground Wire Gauge Power Wire Gauge Humidity: 10 ~ 90% (non-condensing) 18 AWG or larger 18 AWG or larger XGS4700-48F User's Guide 455 CHAPTER 55 Product Specifications The following tables summarize the Switch's hardware and firmware features.
... RS-232 console port Main switch: PWR1, PWR2, SYS, ALM The 100Base-T management port: MGMT Green: 10 Mbps Amber: 100 Mbps Per mini-GBIC port: 1~48 Operating Environment Storage Environment steady: link state blinking: transmitting/receiving Per stacking port: 49~52 Temperature: 0º C ~ 45º C (32º F ~ ... C (-13º F ~ 158º F) Ground Wire Gauge Power Wire Gauge Humidity: 10 ~ 90% (non-condensing) 18 AWG or larger 18 AWG or larger XGS4700-48F User's Guide 455 CHAPTER 55 Product Specifications The following tables summarize the Switch's hardware and firmware features.