User Guide
Page 7
PLA-4xx Series User's Guide 7 Safety Warnings PLA-491 models only: • Caution: Use only in dry locations. • Caution: REDUNDANT BONDING CONDUCTOR SHALL BE CONNECTED TO A LOCAL GROUNDING POINT UNLESS THE TOTAL SYSTEM LEAKAGE CURRENT FROM ALL LOADS COMBINED IS VERIFIED TO BE LESS THAN 500 uA. • For continued protection against risk of fire, replace only with same type and rating of fuse. • To reduce the risk of it properly. Dispose of shock-use only indoors. • For Household Use Only. This product is recyclable.
PLA-4xx Series User's Guide 7 Safety Warnings PLA-491 models only: • Caution: Use only in dry locations. • Caution: REDUNDANT BONDING CONDUCTOR SHALL BE CONNECTED TO A LOCAL GROUNDING POINT UNLESS THE TOTAL SYSTEM LEAKAGE CURRENT FROM ALL LOADS COMBINED IS VERIFIED TO BE LESS THAN 500 uA. • For continued protection against risk of fire, replace only with same type and rating of fuse. • To reduce the risk of it properly. Dispose of shock-use only indoors. • For Household Use Only. This product is recyclable.
User Guide
Page 16
... Network 63 Figure 46 PLA-401 Lights ...65 Figure 47 PLA-400/400 v2/ 402 v2 Lights 67 Figure 48 PLA-470 and PLA-470 v2 Lights 68 Figure 49 PLA491 Lights ...70 Figure 50 Electromagnetic Interference (EMI 83 Figure 51 Wall-mounting Example (PLA-4xx 84 Figure 52 Wall-mounting Example (PLA-491 84 Figure 53 RJ...
... Network 63 Figure 46 PLA-401 Lights ...65 Figure 47 PLA-400/400 v2/ 402 v2 Lights 67 Figure 48 PLA-470 and PLA-470 v2 Lights 68 Figure 49 PLA491 Lights ...70 Figure 50 Electromagnetic Interference (EMI 83 Figure 51 Wall-mounting Example (PLA-4xx 84 Figure 52 Wall-mounting Example (PLA-491 84 Figure 53 RJ...
User Guide
Page 80
... Humidity: 5% ~ 95% Noncondensing PLA401 v2/402 v2 Temperature: 0º C ~ 45º C Humidity: 10% ~ 85% Noncondensing PLA491 Temperature: 0º C ~ 40º C Humidity: 20% ~ 90% Noncondensing Storage Environment PLA-400/401/400 v2/470/470 v2 Temperature: -10º C ~ 70º C Humidity: 10% ~ 85% Noncondensing PLA401 v2... 10/100M BASE-T Ethernet port with Auto MDI/MDIX PLA-470/470 v2/491 4 x 10/100 M Base-T Ethernet Ports with 75 ohm impedance preferred but others are compatible. RG6 cables are on the PLA491 only. PLA491: Four power outlets with EMI filter. Appendix A Product...
... Humidity: 5% ~ 95% Noncondensing PLA401 v2/402 v2 Temperature: 0º C ~ 45º C Humidity: 10% ~ 85% Noncondensing PLA491 Temperature: 0º C ~ 40º C Humidity: 20% ~ 90% Noncondensing Storage Environment PLA-400/401/400 v2/470/470 v2 Temperature: -10º C ~ 70º C Humidity: 10% ~ 85% Noncondensing PLA401 v2... 10/100M BASE-T Ethernet port with Auto MDI/MDIX PLA-470/470 v2/491 4 x 10/100 M Base-T Ethernet Ports with 75 ohm impedance preferred but others are compatible. RG6 cables are on the PLA491 only. PLA491: Four power outlets with EMI filter. Appendix A Product...
User Guide
Page 83
... APPLIANCE WITH EMI FILTER Wall-mounting Instructions Complete the following steps to hang your PLA-400/400 v2/401/401 v2/402 v2/470/470 v2/ 491 on the screws. They need to hold the weight of the PLA-4xx with the screws on the back of obstructions. 2 Drill two holes for the... screws. 3 Do not insert the screws all the way into the wall. PLA-4xx Series User's Guide 83 " See...
... APPLIANCE WITH EMI FILTER Wall-mounting Instructions Complete the following steps to hang your PLA-400/400 v2/401/401 v2/402 v2/470/470 v2/ 491 on the screws. They need to hold the weight of the PLA-4xx with the screws on the back of obstructions. 2 Drill two holes for the... screws. 3 Do not insert the screws all the way into the wall. PLA-4xx Series User's Guide 83 " See...
User Guide
Page 84
Appendix A Product Specifications Figure 51 Wall-mounting Example (PLA-4xx) Figure 52 Wall-mounting Example (PLA-491) Cable Pin Assignments RJ-45 Connector Pin Assignments Figure 53 RJ-45 Connector Pins Table 21 RJ-45 Connector Pin Assignments PIN NO 1 2 3 4 5 RJ-45 SIGNAL ASSIGNMENT RxD + RxD TxD + Not connected Not connected 84 PLA-4xx Series User's Guide
Appendix A Product Specifications Figure 51 Wall-mounting Example (PLA-4xx) Figure 52 Wall-mounting Example (PLA-491) Cable Pin Assignments RJ-45 Connector Pin Assignments Figure 53 RJ-45 Connector Pins Table 21 RJ-45 Connector Pin Assignments PIN NO 1 2 3 4 5 RJ-45 SIGNAL ASSIGNMENT RxD + RxD TxD + Not connected Not connected 84 PLA-4xx Series User's Guide