Block Diagram
Page 1
...OUT [100mW@8Ω] PHONES3 OUT [100mW@8Ω] [-6dB] BA [0dB] BA MONITOR A MASTER ON MONITOR A L OUT [+4dBu] MONITOR A R OUT [+4dBu] [-6dB] BA [0dB] BA MONITOR B MASTER ON LCR CONTROL MONITOR B L/C OUT [+4dBu] MONITOR B R OUT [+4dBu] METER METER METER TB/OSC Relay TB/OSC CONTROL ... MASTER ST MTRX MASTER MONITOR MASTER PHONES Clipping Level MTRX OUT, ST MTRX OUT [+4dBu] MONITOR OUT [+4dBu] PHONES OUT [100mW@8Ω] +30dBu +20dBu +10dBu 0dBu -10dBu -20dBu -30dBu -40dBu -50dBu -60dBu PM5000 Block Diagram PM5000-52C :1~48 PM5000-36 :1~32 PM5000-28 :1~24 MONO INPUT...
...OUT [100mW@8Ω] PHONES3 OUT [100mW@8Ω] [-6dB] BA [0dB] BA MONITOR A MASTER ON MONITOR A L OUT [+4dBu] MONITOR A R OUT [+4dBu] [-6dB] BA [0dB] BA MONITOR B MASTER ON LCR CONTROL MONITOR B L/C OUT [+4dBu] MONITOR B R OUT [+4dBu] METER METER METER TB/OSC Relay TB/OSC CONTROL ... MASTER ST MTRX MASTER MONITOR MASTER PHONES Clipping Level MTRX OUT, ST MTRX OUT [+4dBu] MONITOR OUT [+4dBu] PHONES OUT [100mW@8Ω] +30dBu +20dBu +10dBu 0dBu -10dBu -20dBu -30dBu -40dBu -50dBu -60dBu PM5000 Block Diagram PM5000-52C :1~48 PM5000-36 :1~32 PM5000-28 :1~24 MONO INPUT...
Owner's Manual
Page 9
... 65 Group Assign Safe 65 G/A Bus Assign Safe 65 Recall Safe Select 66 Solo Enable 66 Input Solo Safe 67 Monitor 67 Monitor Mode 67 Monitor Delay 68 Master Cue AFL Position 69 Scene Recall 69 Theater Mode 69 Fader Mode 70 Automation 70 Direct Recall/ Mute... ...........84 Module Removal and Replacement 84 Input Transformer Installation 86 Internal Switch Settings For Each module 88 Connector Pin Assignments 92 PM5000 Self-diagnostic Function 93 Initializing the Internal Memory 93 Error Messages 94 Troubleshooting 95 Specifications 96 1. Others 98 MIDI Data Format 99...
... 65 Group Assign Safe 65 G/A Bus Assign Safe 65 Recall Safe Select 66 Solo Enable 66 Input Solo Safe 67 Monitor 67 Monitor Mode 67 Monitor Delay 68 Master Cue AFL Position 69 Scene Recall 69 Theater Mode 69 Fader Mode 70 Automation 70 Direct Recall/ Mute... ...........84 Module Removal and Replacement 84 Input Transformer Installation 86 Internal Switch Settings For Each module 88 Connector Pin Assignments 92 PM5000 Self-diagnostic Function 93 Initializing the Internal Memory 93 Error Messages 94 Troubleshooting 95 Specifications 96 1. Others 98 MIDI Data Format 99...
Owner's Manual
Page 11
... VCA groups, while the [VCA MUTE] switches mute or un-mute the corresponding VCA groups. The VCA master faders function as required. PM5000 Overview 1 Input Channel Section (page 15) Two types of input channels are independent internally. The post-EQ signal can be assigned to...each input channel. The audio signal from the stereo and mono buses, respectively, and send these signals to the corresponding output. 6 Monitor Control Section (page 40) With two monitor outputs (MONITOR A & B) and [CUE] switches on /off status of 4 stereo and 8 mono matrix mixes. The stereo and mono ...
... VCA groups, while the [VCA MUTE] switches mute or un-mute the corresponding VCA groups. The VCA master faders function as required. PM5000 Overview 1 Input Channel Section (page 15) Two types of input channels are independent internally. The post-EQ signal can be assigned to...each input channel. The audio signal from the stereo and mono buses, respectively, and send these signals to the corresponding output. 6 Monitor Control Section (page 40) With two monitor outputs (MONITOR A & B) and [CUE] switches on /off status of 4 stereo and 8 mono matrix mixes. The stereo and mono ...
Owner's Manual
Page 12
... on the sides of time it interacts with the monitor control section, the meter bridge's LED bar-graph meters provide visual monitoring of final output levels at the end of the unit. Rear Panel PM5000-52C ! ∞ ^% $ PM5000-28 ! # @ ¡º @ ! ∞ ^% $ NOTE All PM5000 inputs and outputs are balanced except for the console...
... on the sides of time it interacts with the monitor control section, the meter bridge's LED bar-graph meters provide visual monitoring of final output levels at the end of the unit. Rear Panel PM5000-52C ! ∞ ^% $ PM5000-28 ! # @ ¡º @ ! ∞ ^% $ NOTE All PM5000 inputs and outputs are balanced except for the console...
Owner's Manual
Page 13
...G/A (group/aux) master, and matrix output connectors are grouped together here. & Monitor Out These are provided on the PM5000-36 and PM5000-28). L and R MATRIX SUB IN connectors are also provided for LCR monitoring (MONITOR B = Center). * Talkback/Oscillator Out The talkback or oscillator signal appears at this... must be connected to direct sunlight, the [HIGH] setting should be connected here (4 connectors on the PM5000-52C, 3 on each group/aux master has G/A SUB IN connectors, both monitor outputs feature stereo 2TR IN (1 & 2) and L/C/R CUE SUB IN connectors, and the stereo and ...
...G/A (group/aux) master, and matrix output connectors are grouped together here. & Monitor Out These are provided on the PM5000-36 and PM5000-28). L and R MATRIX SUB IN connectors are also provided for LCR monitoring (MONITOR B = Center). * Talkback/Oscillator Out The talkback or oscillator signal appears at this... must be connected to direct sunlight, the [HIGH] setting should be connected here (4 connectors on the PM5000-52C, 3 on each group/aux master has G/A SUB IN connectors, both monitor outputs feature stereo 2TR IN (1 & 2) and L/C/R CUE SUB IN connectors, and the stereo and ...
Owner's Manual
Page 20
.... § § MUTE Indicators 1~8 Indicate the mute groups to which the corresponding channel is assigned. The cue signal can also be monitored via its [VCA MUTE] switch, the corresponding VCA indicator will physically move to the memorized settings when a scene memory is assigned. The channel...; ¶ ™ Channel Fader Adjusts the out signal level from changing the channel settings when a scene memory is muted via the rear-panel MONITOR OUT connectors or any of these switches can be engaged to specific VCA and mute groups for details. £ [RECALL SAFE] Switch ...
.... § § MUTE Indicators 1~8 Indicate the mute groups to which the corresponding channel is assigned. The cue signal can also be monitored via its [VCA MUTE] switch, the corresponding VCA indicator will physically move to the memorized settings when a scene memory is assigned. The channel...; ¶ ™ Channel Fader Adjusts the out signal level from changing the channel settings when a scene memory is muted via the rear-panel MONITOR OUT connectors or any of these switches can be engaged to specific VCA and mute groups for details. £ [RECALL SAFE] Switch ...
Owner's Manual
Page 25
...entirely when muted, as described on page 40 for more details. VCA Faders Channel Faders VCA 1 VCA 2 1 2 3 4 5 6 7 Channels 1 and 3 can be monitored by engaging either the VCA 1 or VCA 2 [CUE] switch. Mute Master Switches Channel Faders 1 2 3 4 5 6 7 In this setup channels 1 and 3 can... You can be muted by engaging either the mute master [1] or [2] switch. NOTE Refer to the console's cue (L&R, C) buses for monitoring. NOTE If the mute safe function is engaged (details on page 71). 25 The Mute Master Switches Mute master switches [1] ~ [8] function...
...entirely when muted, as described on page 40 for more details. VCA Faders Channel Faders VCA 1 VCA 2 1 2 3 4 5 6 7 Channels 1 and 3 can be monitored by engaging either the VCA 1 or VCA 2 [CUE] switch. Mute Master Switches Channel Faders 1 2 3 4 5 6 7 In this setup channels 1 and 3 can... You can be muted by engaging either the mute master [1] or [2] switch. NOTE Refer to the console's cue (L&R, C) buses for monitoring. NOTE If the mute safe function is engaged (details on page 71). 25 The Mute Master Switches Mute master switches [1] ~ [8] function...
Owner's Manual
Page 26
... Mute Channel [ON] Switch Indication Mode When the channels assigned to either flash or go out entirely. M U T E M O D E : B L I N K PW5000 POWER SUPPLY POWER ON OFF OPERATION MONITOR NORMAL +16 -16 CAUTION +12 +48 FAN HIGH STOP THERMAL FAN SPEED AUTO HIGH LINE VOLTAGE Power Switch + 25-1 Flashing is the initial default setting...
... Mute Channel [ON] Switch Indication Mode When the channels assigned to either flash or go out entirely. M U T E M O D E : B L I N K PW5000 POWER SUPPLY POWER ON OFF OPERATION MONITOR NORMAL +16 -16 CAUTION +12 +48 FAN HIGH STOP THERMAL FAN SPEED AUTO HIGH LINE VOLTAGE Power Switch + 25-1 Flashing is the initial default setting...
Owner's Manual
Page 31
...cue bus. NOTE With the initial default setup the AFL signal cannot be sent is determined by a scene recall operation. The signal to be monitored unless the master [ON] switch is derived after the master fader and master [ON] switch. The parameters to be protected can be speci...Determines the output level presented at the corresponding master output. $ [CUE] Switch The [CUE] switches are dual configurations, each master. When the monitor control section [MASTER PFL] switch is engaged, the [CUE] switches send the master's pre-fader signal to the cue bus. When a ∑·...
...cue bus. NOTE With the initial default setup the AFL signal cannot be sent is determined by a scene recall operation. The signal to be monitored unless the master [ON] switch is derived after the master fader and master [ON] switch. The parameters to be protected can be speci...Determines the output level presented at the corresponding master output. $ [CUE] Switch The [CUE] switches are dual configurations, each master. When the monitor control section [MASTER PFL] switch is engaged, the [CUE] switches send the master's pre-fader signal to the cue bus. When a ∑·...
Owner's Manual
Page 33
...of the G/A master module. However, similar to the way that can be changed to allow the G/A master signal to be changed to allow AFL monitoring even when the master [ON] switch is functioning as a dual mono aux master. 31 Master Out Section G/A (Group/Aux) Master Module Refer ... engaged @ the same signal is sent to the stereo bus via a utility function (MASTER CUE AFL POSITION = PRE ON), an internal switch setting can be monitored unless the master [ON] switch is functioning as the post-fader AFL signal that this section. ) [TO ST] Switch ! [PAN] Control @ [TO MONO...
...of the G/A master module. However, similar to the way that can be changed to allow the G/A master signal to be changed to allow AFL monitoring even when the master [ON] switch is functioning as a dual mono aux master. 31 Master Out Section G/A (Group/Aux) Master Module Refer ... engaged @ the same signal is sent to the stereo bus via a utility function (MASTER CUE AFL POSITION = PRE ON), an internal switch setting can be monitored unless the master [ON] switch is functioning as the post-fader AFL signal that this section. ) [TO ST] Switch ! [PAN] Control @ [TO MONO...
Owner's Manual
Page 37
... 3 STEREO MATRIX 4 MATRIX 1 MATRIX 2 MATRIX 3 MATRIX 4 MATRIX 5 MATRIX 6 MATRIX 7 MATRIX 8 The master signals flow vertically. Stereo Aux G/A Master Module Master Module Stereo/Mono Master Module Monitor Module [TO MATRIX] Switches The matrix send configuration for each master is basically the same. The outputs from the master modules can be...
... 3 STEREO MATRIX 4 MATRIX 1 MATRIX 2 MATRIX 3 MATRIX 4 MATRIX 5 MATRIX 6 MATRIX 7 MATRIX 8 The master signals flow vertically. Stereo Aux G/A Master Module Master Module Stereo/Mono Master Module Monitor Module [TO MATRIX] Switches The matrix send configuration for each master is basically the same. The outputs from the master modules can be...
Owner's Manual
Page 42
...or master [CUE] switch is provided to allow a delay to be applied to the monitor and headphone outputs for monitoring: the stereo master signal, input from the main house and monitor speakers. 40 If the [2TR IN 1] or [2TR IN 2] switch is not... the monitor source will appear at the MONITOR outputs. The monitor out section controls output to the consoles two monitor outputs (MONITOR A & B OUT) as well as required. NOTE A monitor delay function is engaged (cue monitoring takes priority over 2track input monitoring). Monitor Control Section Monitor Control Section Monitor Source ...
...or master [CUE] switch is provided to allow a delay to be applied to the monitor and headphone outputs for monitoring: the stereo master signal, input from the main house and monitor speakers. 40 If the [2TR IN 1] or [2TR IN 2] switch is not... the monitor source will appear at the MONITOR outputs. The monitor out section controls output to the consoles two monitor outputs (MONITOR A & B OUT) as well as required. NOTE A monitor delay function is engaged (cue monitoring takes priority over 2track input monitoring). Monitor Control Section Monitor Control Section Monitor Source ...
Owner's Manual
Page 43
...CUE. L R Normal Operation [LCR] Engaged L C R [L+R] Engaged L+R (C) R+L [+MONO (C)] Engaged [L+R] and [+MONO (C)] Engaged L+C (C) R+C L+R+C (C) R+L+C Cue Signal Monitoring If an input channel, VCA master, master out, or matrix out [CUE] switched is engaged while the stereo master or 2-track input signal is delivered... to the center channel. One will be engaged to allow the MONITOR B L channel to VCA groups (mono/stereo) AFL (after [PAN/ BAL] control) Stereo aux, G/A (group/aux), stereo,...
...CUE. L R Normal Operation [LCR] Engaged L C R [L+R] Engaged L+R (C) R+L [+MONO (C)] Engaged [L+R] and [+MONO (C)] Engaged L+C (C) R+C L+R+C (C) R+L+C Cue Signal Monitoring If an input channel, VCA master, master out, or matrix out [CUE] switched is engaged while the stereo master or 2-track input signal is delivered... to the center channel. One will be engaged to allow the MONITOR B L channel to VCA groups (mono/stereo) AFL (after [PAN/ BAL] control) Stereo aux, G/A (group/aux), stereo,...
Owner's Manual
Page 44
...via the VCA faders. 42 Cue trim controls are provided to compensate for the AFL signals monitored via the VCA section is always AFL (post fader and post [PAN/BAL] control). Monitor Control Section When a channel [CUE] switch is operated directly the channel's pre-fader ...signal will be sent to the MONITOR outputs. Lit 1 2 3 4 5 6 7 VCA 1 VCA Fader Flashing 1 2 3 4 5 6 7 Channel fader Only channels 1 and 5 can be sent to monitor the PFL or AFL signal from each channel. Gain compensation for the PFL signals from...
...via the VCA faders. 42 Cue trim controls are provided to compensate for the AFL signals monitored via the VCA section is always AFL (post fader and post [PAN/BAL] control). Monitor Control Section When a channel [CUE] switch is operated directly the channel's pre-fader ...signal will be sent to the MONITOR outputs. Lit 1 2 3 4 5 6 7 VCA 1 VCA Fader Flashing 1 2 3 4 5 6 7 Channel fader Only channels 1 and 5 can be sent to monitor the PFL or AFL signal from each channel. Gain compensation for the PFL signals from...
Owner's Manual
Page 45
... panel [CUE] switches are turned off . [MASTER PFL] Switch [LAST CUE] Switch Monitor Control Section The Cue Stack Function All current [CUE] switch settings are all cues at once. In some situations, however, the PM5000 "cue stack" function applies. NOTE All active [CUE] switches will be active (LAST ...CUE mode). To monitor the pre-master-fader signals engage the [MASTER PFL] switch, or disengage it to the...
... panel [CUE] switches are turned off . [MASTER PFL] Switch [LAST CUE] Switch Monitor Control Section The Cue Stack Function All current [CUE] switch settings are all cues at once. In some situations, however, the PM5000 "cue stack" function applies. NOTE All active [CUE] switches will be active (LAST ...CUE mode). To monitor the pre-master-fader signals engage the [MASTER PFL] switch, or disengage it to the...
Owner's Manual
Page 46
... Engaged) Guitar Guitar Bass Vocal Keyboard SOLO House Speaker House Speaker Guitar Guitar Console Monitor Console Monitor PM5000 (Solo Engaged) Guitar Guitar Guitar Bass Vocal Keyboard 44 Since solo monitoring in the PM5000 is handled in essentially the same way as cue monitoring, the term "cue/solo function" can be used interchangeably, and in which no...
... Engaged) Guitar Guitar Bass Vocal Keyboard SOLO House Speaker House Speaker Guitar Guitar Console Monitor Console Monitor PM5000 (Solo Engaged) Guitar Guitar Guitar Bass Vocal Keyboard 44 Since solo monitoring in the PM5000 is handled in essentially the same way as cue monitoring, the term "cue/solo function" can be used interchangeably, and in which no...
Owner's Manual
Page 47
... Speaker L Main House Speaker C Main House Speaker R SOLO MODE PREVIEW STEREO AUX SOLO SELECT GROUP/ ST· AUX MONO(C) MATRIX NOTE Solo monitoring can be activated by holding the [SOLO MODE] switch on page 43. The [LAST CUE] switch can be disengaged. The channel [ON] switches... AUX MONO(C) MATRIX Sub Speaker L Sub Speaker C Sub Speaker R CH1 Signal STEREO AUX1 GROUP/ AUX1 STEREO ST MATRIX1 2ch Recorder MATRIX1 On-stage Monitor Speaker NOTE The [PREVIEW] indicator is routed to be engaged). 45 When the solo mode is active and the channel 1 [CUE] switch is engaged...
... Speaker L Main House Speaker C Main House Speaker R SOLO MODE PREVIEW STEREO AUX SOLO SELECT GROUP/ ST· AUX MONO(C) MATRIX NOTE Solo monitoring can be activated by holding the [SOLO MODE] switch on page 43. The [LAST CUE] switch can be disengaged. The channel [ON] switches... AUX MONO(C) MATRIX Sub Speaker L Sub Speaker C Sub Speaker R CH1 Signal STEREO AUX1 GROUP/ AUX1 STEREO ST MATRIX1 2ch Recorder MATRIX1 On-stage Monitor Speaker NOTE The [PREVIEW] indicator is routed to be engaged). 45 When the solo mode is active and the channel 1 [CUE] switch is engaged...
Owner's Manual
Page 48
...to the main house speakers, sub-speakers, on -stage monitors do receive the channel 1 signal). In addition to the SOLO SELECT switches described above, the PM5000 has input solo safe and solo enable functions that the on -stage monitors, recording equipment and other gear can be muted when a... solo channel is possible to solo-monitor the stereo or stereo aux 1 master outputs by solo operations...
...to the main house speakers, sub-speakers, on -stage monitors do receive the channel 1 signal). In addition to the SOLO SELECT switches described above, the PM5000 has input solo safe and solo enable functions that the on -stage monitors, recording equipment and other gear can be muted when a... solo channel is possible to solo-monitor the stereo or stereo aux 1 master outputs by solo operations...
Owner's Manual
Page 49
... [OSC ON] or talkback [ON] switch is engaged (the TB/ OSC LED at the bottom of these meters at once. Monitor Control Section Meter Bridge The PM5000 meter bridge features precise bar-graph meters that display the signal levels at the master outs (stereo aux, group/aux, stereo, mono...), matrix outs (stereo, mono), cue (L/C/R), and the talkback/ oscillator bus, from -39 dB to PEAK level in the console's monitor control section ...
... [OSC ON] or talkback [ON] switch is engaged (the TB/ OSC LED at the bottom of these meters at once. Monitor Control Section Meter Bridge The PM5000 meter bridge features precise bar-graph meters that display the signal levels at the master outs (stereo aux, group/aux, stereo, mono...), matrix outs (stereo, mono), cue (L/C/R), and the talkback/ oscillator bus, from -39 dB to PEAK level in the console's monitor control section ...
Owner's Manual
Page 50
... (lights when a problem is possible, but if operation becomes impossible the power supply will light as long as operation of the PM5000's internal cooling fans ceases to operate. The FAN CAUTION indicator if one or more of the console and external power supply cooling fans.... Cooling fans (lights when a problem is detected). Gooseneck lamp dimmer. Monitor Control Section The meter bridge also features independent dimmer controls for the meters, panel switch illumination, and gooseneck lamps, as well as possible...
... (lights when a problem is possible, but if operation becomes impossible the power supply will light as long as operation of the PM5000's internal cooling fans ceases to operate. The FAN CAUTION indicator if one or more of the console and external power supply cooling fans.... Cooling fans (lights when a problem is detected). Gooseneck lamp dimmer. Monitor Control Section The meter bridge also features independent dimmer controls for the meters, panel switch illumination, and gooseneck lamps, as well as possible...