User Guide
Page 1
4 Channel, 2 mSATA + 2 SATA 6Gb/s RAID Card with HyperDuo User Manual Model: UGT-MST644R All brand names and trademarks are properties of their respective owners. www.vantecusa.com
4 Channel, 2 mSATA + 2 SATA 6Gb/s RAID Card with HyperDuo User Manual Model: UGT-MST644R All brand names and trademarks are properties of their respective owners. www.vantecusa.com
User Guide
Page 2
Contents: Chapter 1: Introduction 3 1.1 Features 3 1.2 System Requirements 4 1.3 Package Contents 4 Chapter 2: Getting Started 5 2.1 Hardware Layout 5 2.2 Hardware Installation 5 2.3 Creating and Managing Virtual Disk 7 2.3.1 Creating Virtual Disks 7 2.3.2 Managing Virtual Disks 12 2.4 Driver Installation 19 2.5 To Verify Driver Installation 20 2.6 What is HyperDuo 20 UGT-MST644R Page 2
Contents: Chapter 1: Introduction 3 1.1 Features 3 1.2 System Requirements 4 1.3 Package Contents 4 Chapter 2: Getting Started 5 2.1 Hardware Layout 5 2.2 Hardware Installation 5 2.3 Creating and Managing Virtual Disk 7 2.3.1 Creating Virtual Disks 7 2.3.2 Managing Virtual Disks 12 2.4 Driver Installation 19 2.5 To Verify Driver Installation 20 2.6 What is HyperDuo 20 UGT-MST644R Page 2
User Guide
Page 3
... compatible with PCI Express x4, x8 and x16 slots Supports communication speeds of 6.0Gbps, 3.0Gbps, and 1.5Gbps HyperDuo technology to maximum SSD performance Support TRIM to extend SSD durability Hot plug and Hot Swap on SATA connection Supports Port Multiplier FIS/CBS and Native Command Queuing (NCQ) Support ATA and ATAPI commands UGT-MST644R...
... compatible with PCI Express x4, x8 and x16 slots Supports communication speeds of 6.0Gbps, 3.0Gbps, and 1.5Gbps HyperDuo technology to maximum SSD performance Support TRIM to extend SSD durability Hot plug and Hot Swap on SATA connection Supports Port Multiplier FIS/CBS and Native Command Queuing (NCQ) Support ATA and ATAPI commands UGT-MST644R...
User Guide
Page 4
Compatible with SATA III/II/I Hard Drives Support RAID function: RAID 0, RAID 1, RAID 10 and HyperDuo 1.2 System Requirements PCI Express x4, x8 or x16 slot Windows® XP/Vista/7/8/8.1 1.3 Package Contents 1 x 4 Channel, 2 mSATA + 2 SATA 6Gb/s RAID Card with HyperDuo 1 x Driver CD 1 x Installation Guide 2 x SATA Cables 1 x Low Profile Bracket UGT-MST644R Page 4
Compatible with SATA III/II/I Hard Drives Support RAID function: RAID 0, RAID 1, RAID 10 and HyperDuo 1.2 System Requirements PCI Express x4, x8 or x16 slot Windows® XP/Vista/7/8/8.1 1.3 Package Contents 1 x 4 Channel, 2 mSATA + 2 SATA 6Gb/s RAID Card with HyperDuo 1 x Driver CD 1 x Installation Guide 2 x SATA Cables 1 x Low Profile Bracket UGT-MST644R Page 4
User Guide
Page 5
Verify the package contents to make sure you have everything that you need to install this mSATA + SATA PCIe RAID Card. Chapter 2: Getting Started 2.1 Hardware Layout 2.2 Hardware Installation 1. UGT-MST644R Page 5
Verify the package contents to make sure you have everything that you need to install this mSATA + SATA PCIe RAID Card. Chapter 2: Getting Started 2.1 Hardware Layout 2.2 Hardware Installation 1. UGT-MST644R Page 5
User Guide
Page 6
Attach your computer, unplug the power cord and remove the cover of the drivers. Replace the slot bracket's holding the full height bracket, replace the bracket with the setup of the configuration and installation of the computer system. 4. Turn off the power to your SATA devices to secure the card. 8. To install the card, carefully align the card's bus connector with the selected PCIe slot...
Attach your computer, unplug the power cord and remove the cover of the drivers. Replace the slot bracket's holding the full height bracket, replace the bracket with the setup of the configuration and installation of the computer system. 4. Turn off the power to your SATA devices to secure the card. 8. To install the card, carefully align the card's bus connector with the selected PCIe slot...
User Guide
Page 7
... the Marvell BIOS Setup To create a virtual disk 1. 10. During the initial boot, before the windows logo is displayed, Press + to section "2.4 Driver Installation". 2.3 Creating and Managing Virtual Disk 2.3.1 Creating Virtual Disks This section describes the steps for creating virtual disks using the BIOS Configuration Wizard. Figure 2 Configuration Wizard UGT-MST644R Page 7 If you are not setting up any...
... the Marvell BIOS Setup To create a virtual disk 1. 10. During the initial boot, before the windows logo is displayed, Press + to section "2.4 Driver Installation". 2.3 Creating and Managing Virtual Disk 2.3.1 Creating Virtual Disks This section describes the steps for creating virtual disks using the BIOS Configuration Wizard. Figure 2 Configuration Wizard UGT-MST644R Page 7 If you are not setting up any...
User Guide
Page 8
2. After selecting the required disks, press Enter to continue, as shown in Figure 4. Figure 4 Confirm Disk Selection UGT-MST644R Page 8 Figure 3 Select Free Disks 3. Press Space to scroll the list of free disks. Use the arrow keys to select/unselect a disk a disk, as shown in Figure 3.
2. After selecting the required disks, press Enter to continue, as shown in Figure 4. Figure 4 Confirm Disk Selection UGT-MST644R Page 8 Figure 3 Select Free Disks 3. Press Space to scroll the list of free disks. Use the arrow keys to select/unselect a disk a disk, as shown in Figure 3.
User Guide
Page 9
The controls for making selection are properties of the virtual disk UGT-MST644R Page 9 4. Figure 5 Configure Virtual Disk Note: Max size (MB) and Disk ID are listed in Figure 5. Create Virtual Disk by configuring its setting in the Information pane, as shown in the Help pane when an available setting is highlighted.
The controls for making selection are properties of the virtual disk UGT-MST644R Page 9 4. Figure 5 Configure Virtual Disk Note: Max size (MB) and Disk ID are listed in Figure 5. Create Virtual Disk by configuring its setting in the Information pane, as shown in the Help pane when an available setting is highlighted.
User Guide
Page 10
...lists the IDs of the RAID virtual disk as shown in Figure 7. Press Enter to select a RAID Level. UGT-MST644R Page 10 RAID Level, as shown in Figure 6, and press Enter to Next, as determined by the selected RAID Level. Figure 6 RAID Level Note: The default Level is presented. A menu... pops-up, as shown in Figure 6, is highlighted when the Create Virtual Disk screen is HyperDuo...
...lists the IDs of the RAID virtual disk as shown in Figure 7. Press Enter to select a RAID Level. UGT-MST644R Page 10 RAID Level, as shown in Figure 6, and press Enter to Next, as determined by the selected RAID Level. Figure 6 RAID Level Note: The default Level is presented. A menu... pops-up, as shown in Figure 6, is highlighted when the Create Virtual Disk screen is HyperDuo...
User Guide
Page 11
The virtual disk is now listed in the Topology pane, as shown in Figure 8, to select Yes, as shown in Topology Pane UGT-MST644R Page 11 Please Y to confirm the creation of the virtual disk. Figure 8 Create Virtual Disk Confirmation Figure 9 Virtual Disks in Figure 9. Figure 7 Create Virtual Disk 8.
The virtual disk is now listed in the Topology pane, as shown in Figure 8, to select Yes, as shown in Topology Pane UGT-MST644R Page 11 Please Y to confirm the creation of the virtual disk. Figure 8 Create Virtual Disk Confirmation Figure 9 Virtual Disks in Figure 9. Figure 7 Create Virtual Disk 8.
User Guide
Page 13
... UGT-MST644R Page 13 Select Erase RAID Config Data to delete the virtual disk, as shown Figure 11. 2. RAID configuration data must be used with another virtual disk. 1. Figure 10 Virtual Disk Properties: Functional VD Erasing RAID Configuration Data Note: The RAID controller stores RAID configuration data... on the physical disk before it can be erased on all physical disks that are displayed in the Information pane when HyperDuo is highlighted, as shown in Figure 11) and press Enter. virtual disk are part ...
... UGT-MST644R Page 13 Select Erase RAID Config Data to delete the virtual disk, as shown Figure 11. 2. RAID configuration data must be used with another virtual disk. 1. Figure 10 Virtual Disk Properties: Functional VD Erasing RAID Configuration Data Note: The RAID controller stores RAID configuration data... on the physical disk before it can be erased on all physical disks that are displayed in the Information pane when HyperDuo is highlighted, as shown in Figure 11) and press Enter. virtual disk are part ...
User Guide
Page 14
... Data Rebuilding Virtual Disk Note: The mSATA + SATA PCIe Card BIOS support manual rebuilding of a virtual disk is both initiated and complete in the BIOS. Spare physical disks are not supported. Select Yes when prompted to initiate, resume, or complete the rebuild process. 3. Figure 12 Virtual Disk Properties: Degrade VD UGT-MST644R Page 14 The rebuild process is changed...
... Data Rebuilding Virtual Disk Note: The mSATA + SATA PCIe Card BIOS support manual rebuilding of a virtual disk is both initiated and complete in the BIOS. Spare physical disks are not supported. Select Yes when prompted to initiate, resume, or complete the rebuild process. 3. Figure 12 Virtual Disk Properties: Degrade VD UGT-MST644R Page 14 The rebuild process is changed...
User Guide
Page 15
Figure 13 Replace Physical Disks UGT-MST644R Page 15 The mSATA + SATA PCIe RAID Card detects the new physical disk and lists the device under Free Physical Disks in Figure 13. Replace the faulty physical disk with a slightly smaller size as shown in the Topology pane, as determined the Gigabyte Rounding setting for the virtual disk. Note: If an identical disk is unavailable, use a replacement physical disk or larger size or one with an identical physical disk. 2.
Figure 13 Replace Physical Disks UGT-MST644R Page 15 The mSATA + SATA PCIe RAID Card detects the new physical disk and lists the device under Free Physical Disks in Figure 13. Replace the faulty physical disk with a slightly smaller size as shown in the Topology pane, as determined the Gigabyte Rounding setting for the virtual disk. Note: If an identical disk is unavailable, use a replacement physical disk or larger size or one with an identical physical disk. 2.
User Guide
Page 16
3. In the Topology pane, scroll to Virtual Disks (VD 0: New_VD in Figure 14 Scroll to Rebuild and press Enter to select. Figure 14 Rebuild Virtual Disk 4. Scroll through the list of free disk, as shown in Figure 14), and press Enter to configure the rebuild process. A menu pops-up, as shown Figure 15, and press UGT-MST644R Page 16
3. In the Topology pane, scroll to Virtual Disks (VD 0: New_VD in Figure 14 Scroll to Rebuild and press Enter to select. Figure 14 Rebuild Virtual Disk 4. Scroll through the list of free disk, as shown in Figure 14), and press Enter to configure the rebuild process. A menu pops-up, as shown Figure 15, and press UGT-MST644R Page 16
User Guide
Page 17
Press Y to select Yes, as shown in Figure 16, when prompted to continue. Figure 15 Select Replacement Disk 5. Figure 16 Confirm Rebuild Virtual Disk UGT-MST644R Page 17 Press Enter to confirm the rebuild process. Space to select or unselect a replacement physical disk.
Press Y to select Yes, as shown in Figure 16, when prompted to continue. Figure 15 Select Replacement Disk 5. Figure 16 Confirm Rebuild Virtual Disk UGT-MST644R Page 17 Press Enter to confirm the rebuild process. Space to select or unselect a replacement physical disk.
User Guide
Page 18
Press Y to select Yes when prompted Do you want to delete this virtual disk? Press Y to select Yes when prompted Do you want to delete the virtual disk, as shown in Figure 17. UGT-MST644R Page 18 Select Delete to delete MBR from this virtual disk? 4. Figure 17 Rebuild Status Deleting Virtual Disk To delete a virtual disk 1. A menu pops-up, as shown in Figure 18. 3. 6. The status of the Rebuild process is reflected in Figure 18) and press Enter. In the Topology pane, select Virtual Disk (New_VD in the properties of the virtual disk, as shown Figure 18. 2.
Press Y to select Yes when prompted Do you want to delete this virtual disk? Press Y to select Yes when prompted Do you want to delete the virtual disk, as shown in Figure 17. UGT-MST644R Page 18 Select Delete to delete MBR from this virtual disk? 4. Figure 17 Rebuild Status Deleting Virtual Disk To delete a virtual disk 1. A menu pops-up, as shown in Figure 18. 3. 6. The status of the Rebuild process is reflected in Figure 18) and press Enter. In the Topology pane, select Virtual Disk (New_VD in the properties of the virtual disk, as shown Figure 18. 2.
User Guide
Page 19
Figure 18 Delete Virtual Disk 2.4 Driver Installation 1. Follow the on-screen instructions to complete the installation. Restart Windows to complete the installation. Please insert the CD driver bundle with this mSATA RAID Card into your CD-ROM drive letter) 4. Type D:\UGT-MST644R\Setup.exe, click OK. (Change D:\ to match your CD-ROM drive. 2. UGT-MST644R Page 19 At the Windows desktop, click Start, then click Run. 3.
Figure 18 Delete Virtual Disk 2.4 Driver Installation 1. Follow the on-screen instructions to complete the installation. Restart Windows to complete the installation. Please insert the CD driver bundle with this mSATA RAID Card into your CD-ROM drive letter) 4. Type D:\UGT-MST644R\Setup.exe, click OK. (Change D:\ to match your CD-ROM drive. 2. UGT-MST644R Page 19 At the Windows desktop, click Start, then click Run. 3.
User Guide
Page 20
Marvell 92xx SATA 6G Controller should be displayed 2.6 What is HyperDuo? You can easily setup the configuration in the card BIOS to the UGT-MST644R card. UGT-MST644R Page 20 Look for the HDD drive to optimize the performance of operation. to give you combination ...Windows® XP: Double click SCSI and RAID Controller: - This tiering of SSD and HDD can be displayed Windows® Vista/7/8/8.1: Double click Storage controller: - Using safe mode, you mirror frequently access (hot files) in SSD speed and in two modes of storage technology. 2.5 To Verify Driver Installation...
Marvell 92xx SATA 6G Controller should be displayed 2.6 What is HyperDuo? You can easily setup the configuration in the card BIOS to the UGT-MST644R card. UGT-MST644R Page 20 Look for the HDD drive to optimize the performance of operation. to give you combination ...Windows® XP: Double click SCSI and RAID Controller: - This tiering of SSD and HDD can be displayed Windows® Vista/7/8/8.1: Double click Storage controller: - Using safe mode, you mirror frequently access (hot files) in SSD speed and in two modes of storage technology. 2.5 To Verify Driver Installation...
Flyer
Page 1
... Companies www.vantecusa.com Copyright © 2014 Vantec Thermal Technologies. This RAID Host controller enables the use of PCI Express 1.0 technology. Two 7Pin SATA connectors and two mSATA (mini PCIe) socket on SATA connection Supports Native Command Queuing (NCQ) Support ATA and ATAPI commands Compatible with HyperDuo 1 x Driver CD 1 x User Manual 1 x Low Pro le Bracket 2 x SATA Cables Send us an e-mail at 6Gb/s while...
... Companies www.vantecusa.com Copyright © 2014 Vantec Thermal Technologies. This RAID Host controller enables the use of PCI Express 1.0 technology. Two 7Pin SATA connectors and two mSATA (mini PCIe) socket on SATA connection Supports Native Command Queuing (NCQ) Support ATA and ATAPI commands Compatible with HyperDuo 1 x Driver CD 1 x User Manual 1 x Low Pro le Bracket 2 x SATA Cables Send us an e-mail at 6Gb/s while...