ER-A520 | ER-A530 Operation Manual
Page 4
... 2 EXTERNAL VIEW OF THE ER-A520 8 Front view 8 Rear view 8 EXTERNAL VIEW OF THE ER-A530 9 Front view 9 Rear view 9 PRINTER 10 KEYBOARD 11 1 ER-A520 standard keyboard layout 11 2 ER-A530 standard keyboard layout 13 3 Standard key number layout 15 4 Installing the keyboard sheet (ER-A530 16 KEYS AND SWITCHES ... 21 ENTRIES 22 1 Item entries 22 Single item entries 22 Repeat entries 23 Multiplication entries 24 Successive multiplication entries 25 Split-pricing entries 26 Single item cash sale (SICS)/single item finalize (SIF) entries 27 Scale entries 28 PLU level shift (for ...
... 2 EXTERNAL VIEW OF THE ER-A520 8 Front view 8 Rear view 8 EXTERNAL VIEW OF THE ER-A530 9 Front view 9 Rear view 9 PRINTER 10 KEYBOARD 11 1 ER-A520 standard keyboard layout 11 2 ER-A530 standard keyboard layout 13 3 Standard key number layout 15 4 Installing the keyboard sheet (ER-A530 16 KEYS AND SWITCHES ... 21 ENTRIES 22 1 Item entries 22 Single item entries 22 Repeat entries 23 Multiplication entries 24 Successive multiplication entries 25 Split-pricing entries 26 Single item cash sale (SICS)/single item finalize (SIF) entries 27 Scale entries 28 PLU level shift (for ...
ER-A520 | ER-A530 Operation Manual
Page 6
... for programming 80 Direct Programming 80 1 Setting the date and time 80 Date 80 Time 81 2 Programming for departments 81 Unit price 81 Functional selection 82 3 PLU/UPC programming 84 Unit price 84 Functional selection 85 Associated department 86 - 4 Programming for discount keys 87 Discount amount 87 Functional programming 87 % 5 Programming for...
... for programming 80 Direct Programming 80 1 Setting the date and time 80 Date 80 Time 81 2 Programming for departments 81 Unit price 81 Functional selection 82 3 PLU/UPC programming 84 Unit price 84 Functional selection 85 Associated department 86 - 4 Programming for discount keys 87 Discount amount 87 Functional programming 87 % 5 Programming for...
ER-A520 | ER-A530 Operation Manual
Page 7
...109 Color Video Monitor (CVM) control character (#2158 109 5 PLU/UPC programming 110 Associated department (#1200, 2230, 1050 111 Unit prices (#1210, 1060 113 Base quantity (#1211, 1061 114 Functional programming 1 (#2210, 2231, 2060 114 Functional programming 2 (#2211, ... CH TIP , ) (#2312 135 % - +/- Rate ( , , commission, gratuity, CA TIP , CH TIP ) and discount ( ) (#1310 133 Gas discount unit price (#1311 134 ç Currency description text ( ) (#2334 134 - † r p A limit amount (HALO) of function texts 146 9 Server/Cashier programming 150 Server/...
...109 Color Video Monitor (CVM) control character (#2158 109 5 PLU/UPC programming 110 Associated department (#1200, 2230, 1050 111 Unit prices (#1210, 1060 113 Base quantity (#1211, 1061 114 Functional programming 1 (#2210, 2231, 2060 114 Functional programming 2 (#2211, ... CH TIP , ) (#2312 135 % - +/- Rate ( , , commission, gratuity, CA TIP , CH TIP ) and discount ( ) (#1310 133 Gas discount unit price (#1311 134 ç Currency description text ( ) (#2334 134 - † r p A limit amount (HALO) of function texts 146 9 Server/Cashier programming 150 Server/...
ER-A520 | ER-A530 Operation Manual
Page 8
... group total report on PLU/UPC 204 Full group total report on PLU/UPC 204 PLU/UPC zero sales report by department 205 PLU/UPC price category report 205 PLU/UPC stock report (by designated range or pick up list 205 Commission sales report 205 GLU/PBLU report 206 GLU/PBLU...
... group total report on PLU/UPC 204 Full group total report on PLU/UPC 204 PLU/UPC zero sales report by department 205 PLU/UPC price category report 205 PLU/UPC stock report (by designated range or pick up list 205 Commission sales report 205 GLU/PBLU report 206 GLU/PBLU...
ER-A520 | ER-A530 Operation Manual
Page 13
KEYBOARD 1 ER-A520 standard keyboard layout NC SLIP RCPT PBLU CONV RA FINAL %1 PO TAX %2 TAX SHIFT RFND VOID #/TM CASH # PLU/UPC .L @ FOR 789 456 123 0 00 PRICE CHANGE AMT INQ FS AUTO SHIFT 1 5 10 15 20 FS AUTO TEND 2 4 9 14 19 NS CH1 3 8 13 18 CHK CH2 2 7 12 17 MDSE... key Multiplication key Refund key Void key Amount entry key Cashier code entry key PLU/UPC key PLU/UPC inquiry key UPC price change the layout, please consult your authorized SHARP dealer. If you want to change key Discount 1 key %1 %2 Percent 1 and 2 keys NC New check key PBLU Previous ...
KEYBOARD 1 ER-A520 standard keyboard layout NC SLIP RCPT PBLU CONV RA FINAL %1 PO TAX %2 TAX SHIFT RFND VOID #/TM CASH # PLU/UPC .L @ FOR 789 456 123 0 00 PRICE CHANGE AMT INQ FS AUTO SHIFT 1 5 10 15 20 FS AUTO TEND 2 4 9 14 19 NS CH1 3 8 13 18 CHK CH2 2 7 12 17 MDSE... key Multiplication key Refund key Void key Amount entry key Cashier code entry key PLU/UPC key PLU/UPC inquiry key UPC price change the layout, please consult your authorized SHARP dealer. If you want to change key Discount 1 key %1 %2 Percent 1 and 2 keys NC New check key PBLU Previous ...
ER-A520 | ER-A530 Operation Manual
Page 14
Optional keys DEPT Dept. For details, please consult your authorized SHARP dealer. FS TEND CH CH 1 2 CONV CHK SBTL Food stamp tender key Charge 1and 2 keys Currency conversion key ... RETURN Tray subtotal key Return key CHK2 CHK5 Check 2 through 5 keys GAS SBTL P-SHIFT # SCALE Gasoline sales subtotal key Price shift number key Scale entry key TRANS OUT TRANS IN CA TIP CH TIP 12 Transfer out key Transfer in the figure of... tip key Charge tip key L1 P1 PRINT CV CNT L5 PLU level shift 1 thru 5 keys P6 Price level shift 1 thru 6 keys Validation print key Cover count entry key
Optional keys DEPT Dept. For details, please consult your authorized SHARP dealer. FS TEND CH CH 1 2 CONV CHK SBTL Food stamp tender key Charge 1and 2 keys Currency conversion key ... RETURN Tray subtotal key Return key CHK2 CHK5 Check 2 through 5 keys GAS SBTL P-SHIFT # SCALE Gasoline sales subtotal key Price shift number key Scale entry key TRANS OUT TRANS IN CA TIP CH TIP 12 Transfer out key Transfer in the figure of... tip key Charge tip key L1 P1 PRINT CV CNT L5 PLU level shift 1 thru 5 keys P6 Price level shift 1 thru 6 keys Validation print key Cover count entry key
ER-A520 | ER-A530 Operation Manual
Page 15
... Numeric keys 00 000 RFND VOID Refund key Void key • Decimal point key CL Clear key PLU/ Price lookup/subdepartment/ SUB UPC key 1 100 Direct price lookup keys 13 P • Please note that the price lookup/subdepartment/UPC key ( ) and the previous balance key u ( PBAL ) are shown as PLU/ UPC ... Numeric key Note The department and direct PLU keys may be expanded. If you want to change the keyboard layout, please consult your dealer. 2 ER-A530 standard keyboard layout RECEIPT JOURNAL 91 92 93 94 95 96 97 98 L1 99 100 L2 L3 AUTO 1 RCPT % 79 80 81 82...
... Numeric keys 00 000 RFND VOID Refund key Void key • Decimal point key CL Clear key PLU/ Price lookup/subdepartment/ SUB UPC key 1 100 Direct price lookup keys 13 P • Please note that the price lookup/subdepartment/UPC key ( ) and the previous balance key u ( PBAL ) are shown as PLU/ UPC ... Numeric key Note The department and direct PLU keys may be expanded. If you want to change the keyboard layout, please consult your dealer. 2 ER-A530 standard keyboard layout RECEIPT JOURNAL 91 92 93 94 95 96 97 98 L1 99 100 L2 L3 AUTO 1 RCPT % 79 80 81 82...
ER-A520 | ER-A530 Operation Manual
Page 17
For further details with positioning departments and PLU keys, please refer to pages 109 and 130. This layout can be changed by your authorized SHARP dealer. 3 Standard key number layout These key numbers are used for positioning of the department or direct PLU keys, please contact your dealer. LEVEL ...Amount entry key UPC price change key Birthday entry key Refund sales key Waste mode key Condiment next key Condiment cancel key Edit tip key Table# recall key Food stamp shift key Food stamp tender key Note Department and direct PLU keys can be expanded. For ER-A520 005 010 015 ...
For further details with positioning departments and PLU keys, please refer to pages 109 and 130. This layout can be changed by your authorized SHARP dealer. 3 Standard key number layout These key numbers are used for positioning of the department or direct PLU keys, please contact your dealer. LEVEL ...Amount entry key UPC price change key Birthday entry key Refund sales key Waste mode key Condiment next key Condiment cancel key Edit tip key Table# recall key Food stamp shift key Food stamp tender key Note Department and direct PLU keys can be expanded. For ER-A520 005 010 015 ...
ER-A520 | ER-A530 Operation Manual
Page 19
... displaying the date/time and printing the employee's arrival/departure times. To unlock it, turn 90 degrees counterclockwise. It can also be changed often: e.g., unit prices of the three supplied mode keys - MGR: For manager's and submanager's entries The manager can use this mode to make entries that are not permitted...
... displaying the date/time and printing the employee's arrival/departure times. To unlock it, turn 90 degrees counterclockwise. It can also be changed often: e.g., unit prices of the three supplied mode keys - MGR: For manager's and submanager's entries The manager can use this mode to make entries that are not permitted...
ER-A520 | ER-A530 Operation Manual
Page 21
P2L3) Dept. When a preset price has been set, the price is displayed in the function message display area. Error messages When an error occurs, the corresponding error message is displayed in the numeric entry display ... mark When amounts in the REG or OP X/Z mode. In the REG or MGR mode, press the #/ TM key to display the date and time. Price level / PLU level (e.g.
P2L3) Dept. When a preset price has been set, the price is displayed in the function message display area. Error messages When an error occurs, the corresponding error message is displayed in the numeric entry display ... mark When amounts in the REG or OP X/Z mode. In the REG or MGR mode, press the #/ TM key to display the date and time. Price level / PLU level (e.g.
ER-A520 | ER-A530 Operation Manual
Page 24
...) à or å When [preset only dept.] is P used for which the unit price has been programmed as zero (0) are entered, only the sales quantity is added. PLU code PLU/ UPC Note When those departments for the model ER-A520. ENTRIES Note The example entries provided within this manual describe the function key...
...) à or å When [preset only dept.] is P used for which the unit price has been programmed as zero (0) are entered, only the sales quantity is added. PLU code PLU/ UPC Note When those departments for the model ER-A520. ENTRIES Note The example entries provided within this manual describe the function key...
ER-A520 | ER-A530 Operation Manual
Page 25
... UPC entries Scan UPC code Ä UPC code (max.13 digits) PLU/ UPC (Registration) To cancel the learing function entry To set "auto-delete" Unit price (max. 6 digits) NON DELETE c When the dept. no. (1 - 99) DEPT # Example Key operation 1200 3 5 8 à 5 à 680 à 2 PPLU/ UPC P P 11 1200 PLU/ UPC PLU...
... UPC entries Scan UPC code Ä UPC code (max.13 digits) PLU/ UPC (Registration) To cancel the learing function entry To set "auto-delete" Unit price (max. 6 digits) NON DELETE c When the dept. no. (1 - 99) DEPT # Example Key operation 1200 3 5 8 à 5 à 680 à 2 PPLU/ UPC P P 11 1200 PLU/ UPC PLU...
ER-A520 | ER-A530 Operation Manual
Page 26
... UPC a Print . entry (indirect) PLU code PLU code When [preset only dept.] is entered. Enter the unit price using a programmed unit price @ Unit price Department key Dept. entry (indirect) Unit price UPC code Direct PLU key Ä Scan UPC code PLU/ UPC PLU/subdept. with the key. • Q'ty...: Up to four digits integer + three digits decimal • Unit price: Less than a programmed upper limit • Q'ty × unit price: Up to enter quantities that are fractional. 24 PLU/ UPC PLU/ UPC Unit price å PLU/ UPC or PLU entry (indirect) PLU/subdept.
... UPC a Print . entry (indirect) PLU code PLU code When [preset only dept.] is entered. Enter the unit price using a programmed unit price @ Unit price Department key Dept. entry (indirect) Unit price UPC code Direct PLU key Ä Scan UPC code PLU/ UPC PLU/subdept. with the key. • Q'ty...: Up to four digits integer + three digits decimal • Unit price: Less than a programmed upper limit • Q'ty × unit price: Up to enter quantities that are fractional. 24 PLU/ UPC PLU/ UPC Unit price å PLU/ UPC or PLU entry (indirect) PLU/subdept.
ER-A520 | ER-A530 Operation Manual
Page 27
... to seven digits Note • For actual use of items sold by area (square feet). Enter the unit price using a programmed unit price @ Unit price Department key Dept. Successive multiplication entries This function may be desired when you enter a sale of this function, please consult your dealer. ....UPC key, when the item does not exist in the file, the display will å à show "NO RECORD". PLU/ UPC PLU/ UPC Unit price å PLU/ UPC or PLU entry (indirect) PLU/subdept. entry (indirect) When [preset only dept.] is entered. Procedure Length @ Width When using ...
... to seven digits Note • For actual use of items sold by area (square feet). Enter the unit price using a programmed unit price @ Unit price Department key Dept. Successive multiplication entries This function may be desired when you enter a sale of this function, please consult your dealer. ....UPC key, when the item does not exist in the file, the display will å à show "NO RECORD". PLU/ UPC PLU/ UPC Unit price å PLU/ UPC or PLU entry (indirect) PLU/subdept. entry (indirect) When [preset only dept.] is entered. Procedure Length @ Width When using ...
ER-A520 | ER-A530 Operation Manual
Page 28
... q'ty Department key Dept. Note You must use the decimal point ( ) key when entering selling quantities that are fractional. 26 PLU/ UPC PLU/ Unit price UPC per base q'ty å PLU/ UPC or Direct PLU key Ä Only when you use a base q'ty programmed for PLU code UPC code...PLU/ UPC key, when the item does not exist in bulk. Procedure Selling q'ty @ Base q'ty When using the key and department no. Split-pricing entries You may use this function when your customer wants to two digits (integer) Example Key operation Print Department entry PLU entry UPC entry 7 @ ...
... q'ty Department key Dept. Note You must use the decimal point ( ) key when entering selling quantities that are fractional. 26 PLU/ UPC PLU/ Unit price UPC per base q'ty å PLU/ UPC or Direct PLU key Ä Only when you use a base q'ty programmed for PLU code UPC code...PLU/ UPC key, when the item does not exist in bulk. Procedure Selling q'ty @ Base q'ty When using the key and department no. Split-pricing entries You may use this function when your customer wants to two digits (integer) Example Key operation Print Department entry PLU entry UPC entry 7 @ ...
ER-A520 | ER-A530 Operation Manual
Page 30
... When you use a programmed tare no. Scale entries For making entries for "Scale compulsory", it is not necessary to press the key. code à Unit price à or å When [preset only dept.] is empty and reads zero. Example Key operation S 200 1 S P 1 PLU/ UPC c Print 28...make refund or return entries, the weight is entered manually while the scale platter is entered. code Department à Unit price à or å Base wt. ` Unit price per base wt. When [preset only dept.] is automatically read from the connected scale (option) and the net weight ...
... When you use a programmed tare no. Scale entries For making entries for "Scale compulsory", it is not necessary to press the key. code à Unit price à or å When [preset only dept.] is empty and reads zero. Example Key operation S 200 1 S P 1 PLU/ UPC c Print 28...make refund or return entries, the weight is entered manually while the scale platter is entered. code Department à Unit price à or å Base wt. ` Unit price per base wt. When [preset only dept.] is automatically read from the connected scale (option) and the net weight ...
ER-A520 | ER-A530 Operation Manual
Page 31
... Up to 2 digits (integer) Example Key operation 32 . 85 Ï S 200 1 . Ï S P 37 25 1 PLU/ UPC c Print 29 code à Unit price à or å When [preset only dept.] is from the customer's receipt. • Base weight: Up to 5 digits (integer + decimal) which is entered. programmed for... PLU code Unit price per base wt. PLU/ UPC PLU/ UPC Unit price per base wt. Net weight Ï SCALE Base wt. ` Unit price per base wt. å PLU/ UPC or Only when you use a base wt. is ...
... Up to 2 digits (integer) Example Key operation 32 . 85 Ï S 200 1 . Ï S P 37 25 1 PLU/ UPC c Print 29 code à Unit price à or å When [preset only dept.] is from the customer's receipt. • Base weight: Up to 5 digits (integer + decimal) which is entered. programmed for... PLU code Unit price per base wt. PLU/ UPC PLU/ UPC Unit price per base wt. Net weight Ï SCALE Base wt. ` Unit price per base wt. å PLU/ UPC or Only when you use a base wt. is ...
ER-A520 | ER-A530 Operation Manual
Page 34
... to use the P1 key on the keyboard, but if you finalize one transaction. ** The lock shift mode holds the current PLU/UPC price level until pressing the price level shift key. Procedure (each item) P2 thru P6 Level no . (1 to 6) ¥ Ä Numeric entry @ (Q ty, etc.) PLU/... (The normal level is not necessary to level 1 after a PLU/UPC shift entry. You can change a PLU/UPC price among six prices by entering level number and pressing the price level shift number key, . Please refer to "Programming for optional feature selection" described in the automatic return mode, press a...
... to use the P1 key on the keyboard, but if you finalize one transaction. ** The lock shift mode holds the current PLU/UPC price level until pressing the price level shift key. Procedure (each item) P2 thru P6 Level no . (1 to 6) ¥ Ä Numeric entry @ (Q ty, etc.) PLU/... (The normal level is not necessary to level 1 after a PLU/UPC shift entry. You can change a PLU/UPC price among six prices by entering level number and pressing the price level shift number key, . Please refer to "Programming for optional feature selection" described in the automatic return mode, press a...
ER-A520 | ER-A530 Operation Manual
Page 35
... then those PLUs linked to the set PLU are the same as normal PLU's. Example Key operation p a Print Note The unit price of the set PLU (ex. The tied PLU's memory is the registered amount of the set PLU. PLU 20) is updated only by ...shift mode: Key operation 1 PPLU/ UPC 1 P P2 PLU/ UPC 2 PPLU/ UPC a Print Set PLU entries Operations are printed automatically. Example PLU price level 1: PLU 1 ($1.91), PLU 2 ($0.79) PLU price level 2: PLU 1 ($2.00), PLU 2 ($0.99) • When your register has been programmed for the automatic return mode (by the entered quantity. 33...
... then those PLUs linked to the set PLU are the same as normal PLU's. Example Key operation p a Print Note The unit price of the set PLU (ex. The tied PLU's memory is the registered amount of the set PLU. PLU 20) is updated only by ...shift mode: Key operation 1 PPLU/ UPC 1 P P2 PLU/ UPC 2 PPLU/ UPC a Print Set PLU entries Operations are printed automatically. Example PLU price level 1: PLU 1 ($1.91), PLU 2 ($0.79) PLU price level 2: PLU 1 ($2.00), PLU 2 ($0.99) • When your register has been programmed for the automatic return mode (by the entered quantity. 33...
ER-A520 | ER-A530 Operation Manual
Page 37
... registered. CHIPS 0.60) (MASHED.P 0.60) (BAKED.P 0.50) Menu-item PLUs (PLU210 is linked to table #1) Message text Condiment PLUs (preset price entry is assigned to enter one group. "POTATO?" will a appear. All items that are programmed into the same table are allowed to PLU 210 (item... label: STEAK/unit price: $13:00). Example Selling on a mix-and-match basis the following items in a lump (e.g. appears. In an example of the condiment ...
... registered. CHIPS 0.60) (MASHED.P 0.60) (BAKED.P 0.50) Menu-item PLUs (PLU210 is linked to table #1) Message text Condiment PLUs (preset price entry is assigned to enter one group. "POTATO?" will a appear. All items that are programmed into the same table are allowed to PLU 210 (item... label: STEAK/unit price: $13:00). Example Selling on a mix-and-match basis the following items in a lump (e.g. appears. In an example of the condiment ...