... reference to memory file groups, please refer to SRV JOB#971 on page 14. JOB# File table No./No.of records/ No.of used records Error message File memory start address Empty memory start address Memory end address Note: The SRV mode programming printout lists the actual memory files.
... reference to memory file groups, please refer to SRV JOB#971 on page 14. JOB# File table No./No.of records/ No.of used records Error message File memory start address Empty memory start address Memory end address Note: The SRV mode programming printout lists the actual memory files.
Programmer Manual
Page 10
... No Yes No 913-C 05 1 2 3 #913-D: 1. Drawer closed compulsory Non-compulsory Compulsory 2. Error mode All lock error Miss operation (One shot error) All lock error Miss operation (One shot error) 3. Tax delete operation 1. Content of a LOGO Graphical LOGO only Graphical LOGO and 3-line footer 6-...Inhibit Enable Inhibit Enable Inhibit Enable 914-A 0 1 2 35 4 5 6 7 Footer print control 1. Printing of finalization #912-D: 1. Error beep 2-sec. Footer print control All receipt On selected function keys at the time of finalization All receipt On selected function keys at the time...
... No Yes No 913-C 05 1 2 3 #913-D: 1. Drawer closed compulsory Non-compulsory Compulsory 2. Error mode All lock error Miss operation (One shot error) All lock error Miss operation (One shot error) 3. Tax delete operation 1. Content of a LOGO Graphical LOGO only Graphical LOGO and 3-line footer 6-...Inhibit Enable Inhibit Enable Inhibit Enable 914-A 0 1 2 35 4 5 6 7 Footer print control 1. Printing of finalization #912-D: 1. Error beep 2-sec. Footer print control All receipt On selected function keys at the time of finalization All receipt On selected function keys at the time...
Programmer Manual
Page 40
... by the ECR at any one time. DEPRESSION OF THE ST KEY AT FOLLOWING POINTS WILL RESULT IN A TAX TABLE DELETE OPERATION. Will ENTRY ERROR is occurred when a device has been set as the same channel that is used 8 = Standard port 1 NOTE: There can be only 2... 8 bits 0 7 bits 1 X: Parity bit X Even 0 Odd 1 Non 2 Y: Stop bit Y 2 bits 0 1 bit 1 Z: Transmission speed Z 4800 bps 0 9600 bps 1 19200 bps 2 MRS = 1110(For ER-A6HS1) [Job# 2710] TAX TABLE PROGRAMMING 2710 @/FOR AB @/FOR Declaration of TAX XX.XXXX TAX rate XXXX Cycle @/FOR XXX @/FOR Initial TAX XXXXX...
... by the ECR at any one time. DEPRESSION OF THE ST KEY AT FOLLOWING POINTS WILL RESULT IN A TAX TABLE DELETE OPERATION. Will ENTRY ERROR is occurred when a device has been set as the same channel that is used 8 = Standard port 1 NOTE: There can be only 2... 8 bits 0 7 bits 1 X: Parity bit X Even 0 Odd 1 Non 2 Y: Stop bit Y 2 bits 0 1 bit 1 Z: Transmission speed Z 4800 bps 0 9600 bps 1 19200 bps 2 MRS = 1110(For ER-A6HS1) [Job# 2710] TAX TABLE PROGRAMMING 2710 @/FOR AB @/FOR Declaration of TAX XX.XXXX TAX rate XXXX Cycle @/FOR XXX @/FOR Initial TAX XXXXX...
Service Manual
Page 3
... the PGM1 mode programming. • PGM1: Allows programming of display Character size $ Fig. 4-2 7 segment display (LED) 7 Yellow Green 14.2 (H) ! 8.0 (W) mm Display contents Amount Minus sign Error PGM Mode VOID Mode RFND SALE Mode CASH, CHECK, CHARGE SUB TOTAL / short tender Change Foreign Currency SUB TOTAL Food Stamp Change Department PLU Repeat...
... the PGM1 mode programming. • PGM1: Allows programming of display Character size $ Fig. 4-2 7 segment display (LED) 7 Yellow Green 14.2 (H) ! 8.0 (W) mm Display contents Amount Minus sign Error PGM Mode VOID Mode RFND SALE Mode CASH, CHECK, CHARGE SUB TOTAL / short tender Change Foreign Currency SUB TOTAL Food Stamp Change Department PLU Repeat...
Service Manual
Page 30
Then the CPU outputs a reset request to stop. Reset request SHEN DON'T CARE SCK LDRQ RES1 TL 20µsec or more TH 20µsec or more TL+TH 2) Power off sequence When the CPU senses a service interruption, it performs the necessary procedures for the CPU to the CKDC8.
Then the CPU outputs a reset request to stop. Reset request SHEN DON'T CARE SCK LDRQ RES1 TL 20µsec or more TH 20µsec or more TL+TH 2) Power off sequence When the CPU senses a service interruption, it performs the necessary procedures for the CPU to the CKDC8.
Service Manual
Page 32
... 3) Check items 1. The termination print is not performed. [4] Keyboard test 1) Key operation XXXX 104 CA/AT XXXX: Sumcheck data Standard keyboard layout sum check data ER-A450T 2254 2) Functional description The keyboard test is performed with the sum check data of the following keys will be displayed every time the keys are... 0C 02 0B 01 0A 00 1A 19 06 07 08 5 - 2 If the data agree with the added data which are pressed. If not, the error print is made . The data are compared with the added data, the end print is made . "---" indicates that a key is struck twice and also that...
... 3) Check items 1. The termination print is not performed. [4] Keyboard test 1) Key operation XXXX 104 CA/AT XXXX: Sumcheck data Standard keyboard layout sum check data ER-A450T 2254 2) Functional description The keyboard test is performed with the sum check data of the following keys will be displayed every time the keys are... 0C 02 0B 01 0A 00 1A 19 06 07 08 5 - 2 If the data agree with the added data which are pressed. If not, the error print is made . The data are compared with the added data, the end print is made . "---" indicates that a key is struck twice and also that...
Service Manual
Page 33
... the following order, a numerical value corresponding to each position of the mode switch is displayed at X. and message is printed Normal end 1 0 4 Error E----- 1 0 4 [5] Mode switch test 1) Key operation 105 CA/AT 2) Functional description Display the following message on the operator display. 1 0 ...test and the content of end print. 4) Test termination The test terminates and the test No. and message is printed Normal end 1 0 5 Error E----- 1 0 5 [6] Printer sensor test 1) Key operation 106 CA/AT 2) Functional description State of the paper near end sensor is sensed and...
... the following order, a numerical value corresponding to each position of the mode switch is displayed at X. and message is printed Normal end 1 0 4 Error E----- 1 0 4 [5] Mode switch test 1) Key operation 105 CA/AT 2) Functional description Display the following message on the operator display. 1 0 ...test and the content of end print. 4) Test termination The test terminates and the test No. and message is printed Normal end 1 0 5 Error E----- 1 0 5 [6] Printer sensor test 1) Key operation 106 CA/AT 2) Functional description State of the paper near end sensor is sensed and...
Service Manual
Page 34
... the current time. and message is sensed and displayed. 1 1 1 X 3) Check items X Description O Drawer open sensor detected. (Drawer opend) C Drawer open sensor is printed Normal end 1 0 9 Error E----- 1 0 9 SSP table full F----- 1 0 9 In this SSP check, set the data for check in the empty area of SSP entry REG and erase the data for...
... the current time. and message is sensed and displayed. 1 1 1 X 3) Check items X Description O Drawer open sensor detected. (Drawer opend) C Drawer open sensor is printed Normal end 1 0 9 Error E----- 1 0 9 SSP table full F----- 1 0 9 In this SSP check, set the data for check in the empty area of SSP entry REG and erase the data for...
Service Manual
Page 35
... control and is terminated. Option RAM Memory to be checked (1C0000H~1FFFFFH). Perform the following check for memory address to be checked ER-03RA Address area to the CPU A/D convertor is performed further. PASS6: Restore the memory data. Termination printout: Normal termination 120 Abnormal... termination Ex - - - - - 120 X = 1: Data check error 2: Address check error Note: When an error occurs, the error print is performed and the check is displayed repeatedly. If the lower two digits of code table is provided...
... control and is terminated. Option RAM Memory to be checked (1C0000H~1FFFFFH). Perform the following check for memory address to be checked ER-03RA Address area to the CPU A/D convertor is performed further. PASS6: Restore the memory data. Termination printout: Normal termination 120 Abnormal... termination Ex - - - - - 120 X = 1: Data check error 2: Address check error Note: When an error occurs, the error print is performed and the check is displayed repeatedly. If the lower two digits of code table is provided...
Service Manual
Page 36
... above checks should be made with the baud rate set the corresponding timer at 9600BPS. Termination print E1--E2--- 200 (data check error) 200 (address check error) 200 (normal end) : Error address [15] RS-232 Channel 1 check [16] RS-232 channel 8 check Loop back connector for D-SUB 9pin : UKOG-6705RCZZ... PIN No. 123456789 SIGNAL NAME CD RD SD ER GND DR RS CS CI 1) Key operation check The program is activated by JOB#...
... above checks should be made with the baud rate set the corresponding timer at 9600BPS. Termination print E1--E2--- 200 (data check error) 200 (address check error) 200 (normal end) : Error address [15] RS-232 Channel 1 check [16] RS-232 channel 8 check Loop back connector for D-SUB 9pin : UKOG-6705RCZZ... PIN No. 123456789 SIGNAL NAME CD RD SD ER GND DR RS CS CI 1) Key operation check The program is activated by JOB#...
Service Manual
Page 37
... (Reception is impossible. Termination print-out: 50nn nn : 01 or 50 Ref.:Print generated when an error occurs When no error print-out has occurred.) ERROR ERROR PRINT Contents 1 E1-ER DR ERn-DRn ERR 2 E2-ER CI ERn-CIn ERR 3 E3-RS CD RSn-CDn ERR 4 E4-RS CS RSn-CSn ERR 5 E5-CI INT...
... (Reception is impossible. Termination print-out: 50nn nn : 01 or 50 Ref.:Print generated when an error occurs When no error print-out has occurred.) ERROR ERROR PRINT Contents 1 E1-ER DR ERn-DRn ERR 2 E2-ER CI ERn-CIn ERR 3 E3-RS CD RSn-CDn ERR 4 E4-RS CS RSn-CSn ERR 5 E5-CI INT...
Service Manual
Page 40
... ECR to ECR only) 6) Transmission status. Description of error status 1: Application error (Command error) 2: Application error (Parity error) 3: Application error (Check sum error) 4: Application error (Data size error) 5: Hard ware error 6: Power off the power switch of the ER-02FD, and set the DIP switches of the FD unit as follows: ER-02FD (The ER-01FD functions of the receiving unit must be...
... ECR to ECR only) 6) Transmission status. Description of error status 1: Application error (Command error) 2: Application error (Parity error) 3: Application error (Check sum error) 4: Application error (Data size error) 5: Hard ware error 6: Power off the power switch of the ER-02FD, and set the DIP switches of the FD unit as follows: ER-02FD (The ER-01FD functions of the receiving unit must be...
Service Manual
Page 43
...after finalizing the transaction. E77 Price shift error E79 Reading of entry. SERVICE PRECAUTION 1. E04 Joumal paper is inhibited. E33 The current cashier code should not be taken when removing the TOP CABINET After removing the ER-A450T's TOP CABINET, put the TOP CABINET ...upright on the left of memory. E02 Misoperation error Make a correct key entry. Error code Error status Action E01 Registration error Make a correct key entry. E12 Compulsory tendering Make ...
...after finalizing the transaction. E77 Price shift error E79 Reading of entry. SERVICE PRECAUTION 1. E04 Joumal paper is inhibited. E33 The current cashier code should not be taken when removing the TOP CABINET After removing the ER-A450T's TOP CABINET, put the TOP CABINET ...upright on the left of memory. E02 Misoperation error Make a correct key entry. Error code Error status Action E01 Registration error Make a correct key entry. E12 Compulsory tendering Make ...
Dealer Knowledge Book
Page 1
... - SRV Mode Settings 6 - Converting Images for the Logo Converter Utility 8 5. Preliminary draft Dealer Knowledge Book I'm also here to the ER-A450T 11 7. Quick Start Procedures 17 Notice: This software and/or documentation are furnished under license and may be reproduced, stored in a retrieval ... be used or copied in the United States and/ or other countries. MODEL ER-A450T LOGOCONV.exe Logo Converter Utility Contents Category Pg. 1. Designs and specifications are either registered trademarks or trademarks of Sharp Corporation. Error Code Descriptions 16 9.
... - SRV Mode Settings 6 - Converting Images for the Logo Converter Utility 8 5. Preliminary draft Dealer Knowledge Book I'm also here to the ER-A450T 11 7. Quick Start Procedures 17 Notice: This software and/or documentation are furnished under license and may be reproduced, stored in a retrieval ... be used or copied in the United States and/ or other countries. MODEL ER-A450T LOGOCONV.exe Logo Converter Utility Contents Category Pg. 1. Designs and specifications are either registered trademarks or trademarks of Sharp Corporation. Error Code Descriptions 16 9.
Dealer Knowledge Book
Page 17
... 25) (FIG.25) 2. Code : Description 01 : COMMAND ERROR 02 : PARITY ERROR 03 : CHECKSUM ERROR 04 : DATA SIZE ERROR 05 : HARDWARE ERROR 06 : POWER OFF ERROR (Power off during communication) 07 : TIME OUT ERROR 08 : DSR OFF ERROR (PCs DTR signal is OFF) 11 :... are subject to the ER-A450T's SIO communications function. Error Code Decriptions ERROR DESCRIPTIONS Although the LOGOCONV.exe PC utility is received.) Note: The above error codes are printed on the ER-A450T's printer on the journal side. The following Communications error could result which are related...
... 25) (FIG.25) 2. Code : Description 01 : COMMAND ERROR 02 : PARITY ERROR 03 : CHECKSUM ERROR 04 : DATA SIZE ERROR 05 : HARDWARE ERROR 06 : POWER OFF ERROR (Power off during communication) 07 : TIME OUT ERROR 08 : DSR OFF ERROR (PCs DTR signal is OFF) 11 :... are subject to the ER-A450T's SIO communications function. Error Code Decriptions ERROR DESCRIPTIONS Although the LOGOCONV.exe PC utility is received.) Note: The above error codes are printed on the ER-A450T's printer on the journal side. The following Communications error could result which are related...