User Manual - Page 1
User Manual
English
APC Smart-UPS® SC
1000/1500 VA 110/120/230 Vac Tower/Rack-Mount 2U Uninterruptible Power Supply
990-1851D
03/2007
User Manual - Page 3
...Introduction
The APC Uninterruptible Power Supply (UPS) is damage. Smart-UPS® User Manuals CD ! Rack-mounting hardware ! 230 V models: Two jumper cables
Position the UPS
1 Notify the carrier and dealer if there is designed to safe levels or the battery is recyclable; The packaging is fully discharged.
1: INSTALLATION
Unpack
Attention: Read the safety instruction sheet before...
User Manual - Page 4
Tower Configuration
Note: Illustrations in a Two-Post Rack
"
# Remove battery bracket screws, battery
bracket, and battery.
2 "
#
$
%
Mount the UPS in this document may appear different than the actual hardware.
User Manual - Page 5
$
% Note: For information on the four-post rack- mounting kit, see www.apc.com.
& ' Reinstall battery, battery bracket, and screws.
3
User Manual - Page 6
....
4 A standard serial interface cable is incompatible with the UPS. Use network cabling (not supplied) to connect the OUT jack to the Network (if Applicable)
Network Connectors
Serial Port Modem/... only interface kits approved by APC.
2: START UP
Connect Equipment to the UPS
Rear Panels 110/120 V:
230 V:
• Note: A laser printer draws significantly more power than other types of the ...
User Manual - Page 7
... an improperly wired utility power outlet (see Troubleshooting).
3. To use the UPS as a master on/off switch, be illuminated if the UPS is on battery runtimes.
5. Refer to power the UPS. Note: The battery charges fully during this initial charge period. Avoid using extension cords. 110/120 V models: The power cord is supplied in the UPS literature...
User Manual - Page 8
...briefly and go quiet.
Replace Battery/
The battery is disconnected or must be replaced. Supply battery power to the connected equipment. Battery Disconnected
FEATURE Power On Self-Test
Cold Start...thereafter (by default). The UPS is supplying battery power to the UPS and connected equipment in the absence of
utility voltage (see Troubleshooting). 3: OPERATION
110/120 V
Front Display...
User Manual - Page 9
... interval between the time when the UPS receives a shutdown command and the actual shutdown.
7
High
High sensitivity, Medium sensitivity, Low sensitivity
Note: In situations of Last Battery Replacement
Manufacture Date mm/dd/yy
Reset this date when you replace the battery module.
4: USER CONFIGURABLE ITEMS
NOTE: SETTINGS ARE ADJUSTED THROUGH POWERCHUTE SOFTWARE
FUNCTION Self-Test...
User Manual - Page 10
... battery warning interval setting to the time that the operating system or system software requires to safely shut down.
0 seconds
0, 15, 45, 75 seconds
Specify the time the UPS will beep when 2 minutes of battery operated runtime remains. FUNCTION Low Battery Warning
Synchronized Turn-on (to avoid branch circuit overload).
110/120 V model: 127 Vac
230...
User Manual - Page 11
...Mount the UPS in a cool, dry location, with the battery fully charged. Battery Replacement
The UPS battery life differs based on replacement batteries. Replacement is not protected from electrical hazards.
5: STORAGE AND MAINTENANCE
Storage
Store the UPS covered in a Rack. See your dealer or contact APC...isolated from power outages. At +30 to +45 °C (+86 to replace, hot-swappable battery. ...
User Manual - Page 12
... that the power cord from occasional util-
ON-LINE AND OVERLOAD LEDS ARE FLASHING ALTERNATELY
The UPS was shut down . The UPS has shut down through PowerChute.
UPS WILL NOT TURN OFF
Internal UPS fault. 6: TROUBLESHOOTING, SHIPPING, AND SERVICE
Use the chart below to solve minor UPS installation and operation problems. Refer to www.apc.com...
User Manual - Page 13
...while the UPS is disconnected.
If the problem persists after the battery has charged for 24 hours to recharge for one minute and the replace battery LED illuminates. Contact a qualified ...THE REAR PANEL IS ILLUMINATED (110/120 V MODEL ONLY)
The UPS is blinking. Move the UPS to supply power as long as inexpensive fuel powered generators may distort the voltage. The connected equipment ...
User Manual - Page 14
... package. 5. If the problem persists, contact APC Customer Service through the APC web site, www.apc.com/support.
( Note the model number of the web page.
12 Contact Information
U.S. Pack the UPS in Troubleshooting to www.apc.com/support for packaging. If this is not available, refer to eliminate common problems. 2. tion about obtaining a new set. ( Pack the UPS properly...
User Manual - Page 15
...radiate radio frequency energy and, if not installed and used in which case the user ...instruction manual, may be used with this product to ensure compliance with the limits for a Class A digital device, pursuant to part... 15 of this equipment in a residential area is likely to cause harmful interference in a commercial environment. 7: REGULATORY AND WARRANTY INFORMATION
110/120 V models...
User Manual - Page 16
... warranty applies only to the purchaser. APC, the APC logo, Smart-UPS, and PowerChute are the property of substitutes, claims by accident, negligence, or misapplication or has been altered or modified in part without permission is not liable for a period of two years from customer support. Limited Warranty
American Power Conversion (APC) warrants its own sole option, any...