NEC X462HB Support and Manuals
Popular NEC X462HB Manual Pages
P401 : KT-46UN-CC spec brochure - Page 1
... software
46" X462UN 46" X461HB 43" X431BT
One or more of displayable colors or introducing
color banding artifacts
• Gamma Correction - Single displays to be saved as a project file for
Supported LCD Displays
Windows: Microsoft Windows XP or Vista (32 or 64 bit versions)
Mac OS: Mac OS 10.4 or higher Intel or PowerPC Processor
Hardware: Supported model of NEC displays Supported...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 1
... Interface (3) Baud rate (4) Data length (5) Parity (6) Stop bit (7) Communication code
Asynchronous RS-232C 9600bps 8bits None 1 bit ASCII
3.2 LAN control
(1) Communication ...to change, Please refer "Network settings" on User's manual.)
3. TCP/IP (Internet protocol suite) Ethernet (CSMA/CD) Transport layer (TCP) * Using the payload of the NEC LCD monitor, MultiSync X461UN /X461HB /X431BT /P401...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 5
.... Refer to section 5.5 "Commands message" for more details.
4.5 Check code
Header Message Check code Delimiter
Check code is the Block Check Code (BCC) between the Header and the End of Message except SOH.
Message format of the "Set parameter" is as follows,
STX
OP code OP code page
Set Value
ETX
Hi Lo Hi Lo MSB
LSB
...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 12
... the section 4.5 "Check code" for a BCC calculation.
Delimiter CR (0Dh): End of which you want to the section 4.5 "Check code" for a BCC calculation. No error. '0'-'0' (30h, 30h): Operation code page number is 0. '1'-'0' (31h, 30h): Operation code is 18 bytes. ETX (03h): End of Message
Check code
BCC: Block Check Code Refer to change a setting.
Delimiter
Delimiter CR
(12...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 13
...parameter reply". '1'-'2' (31h, 32h): Message length is 100(0064h). '0'-'0'-'5'-'0' (30h, 30h, 35h, 30h): Received a Brightness setting was 80(0050h) .
No error. '0'-'0' (30h, 30h): Operation code page number is 0. '1'-'0' (31h, 30h): Operation code is 10h (in temperature sensors. The controller can monitor inside temperatures by using those sensors with a message for confirmation. CR (0Dh...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 14
... this byte is 18 bytes.
The monitor replies for reading the temperatures from the sensors. No error. '0'-'2' (30h, 32h): Operation code page number is 2. '7'-'8' (37h, 38h): Operation code is 78h (in the page 2). '0'-'0' (30h, 30h): This operation is "Set parameter" type. '0'-'0'-'0'-'3' (30h, 30h, 30h, 33h): Number of temperature sensors are 3 (0003h). '0'-'0'-'0'-'1' (30h, 30h, 30h...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 15
... '0' (30h): Reserved Monitor ID: Specify the Monitor ID which you want to the section 4.5 "Check code" for a BCC calculation. The monitor replies a temperature of packet
Step 4.
No error. '0'-'2' (30h, 32h): Operation code page number is 2. '7'-'9' (37h, 39h): Operation code is 79h (in the page 2). Delimiter CR (0Dh): End of selected sensor.
Temperature [Celsius]
+125...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 18
... data. At first set . 0004: OFF (same as the power off by IR) ETX (03h): End of Asset data area. '2'-'0' (32h, 30h): Read out data length is the controller.
No error. 'C'-'2','0'-'3'-'D'-'6' (43h,...reply
This command is set 20h: Read data from the top of Message
Check code BCC: Block Check Code Refer to reply with Asset data.
Asset Data read and write
MultiSync X461UN /X461HB /X431BT...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 20
No error. 'C'-'0'-'0'-'E' (43h, 30h, 30h, 45h): Asset Data write command '0'-'0'(30h, 30h): Offset address from top ... (30h): Reserved '0' (30h): Message receiver is the controller Monitor ID: Indicate a replying Monitor ID Ex.) When this byte is set to the section 4.5 "Check code" for a BCC calculation. Date & Time read and write
9.1 Date & Time Read
This command is "Command". '0'-'6'(30h, 36h):...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 40
...Reserved Monitor ID: Specify the Monitor ID of which you want to the section 4.5 "Check code" for a BCC calculation. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message... receiver is set the condition of Message
Check code BCC: Block Check Code Refer to change a setting. Header
Message
SOH-'0'-'0'-Monitor ID-'B'-'0'-'A' STX-'C'-'3'-'1'-'D'-ST-EN-ETX
Check code Delimiter
BCC
CR...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 49
Momentary
Momentary This operation requires supported option TV tuner.
Refer to
the
monitor
instruction
manual. Please refer
to section 6.2 0: | 999: 0: | 65535:
sRGB: PC mode only
Cinema: A/V mode only
ISF-Day: ISF-Night: Each needs an adjustment by side (Full) 0: No mean 1: VGA 2: RGB/HV 3: DVI 4: HDMI (Set only) 5: Video1 6: Video2 7: S-Video 10: TV 12: DVD...
Specification Brochure - Page 2
Specifications for X462HB
MODEL LCD MODULE
Panel Technology Viewable Image Size Native Resolution Brightness (Typical) Contrast Ratio (Typical) Viewing Angle Response Time (white to black) Aspect Ratio Active Screen Area (W x H) Orientation Displayable Colors CONNECTIVITY Supported Video Formats PC/Mac Signal Compatibility Input Terminals
Digital Analog Audio External Control Output Terminals ...
Launch Press Release - Page 1
...The improvement of NEC's high-bright display addresses the concerns of commercial LCD display and projector solutions, announced today the latest addition to accommodate high ambient lighting conditions or outdoor installations. The new X462HB offers a quarter-lambda polarizing film, which allows for LargeScreen Displays at NEC Display Solutions. "This type of model is another upgrade that our...
Users Manual - Page 22
...or AMBIENT2 is selected in picture mode, this function cannot be loaded using NEC optional software. to the background.
CLOCK PHASE
Adjusts the visual "noise" ...VIDEO2, S-VIDEO, TV* inputs only
AUTO*2
ADAPTIVE CONTRAST Sets the level of the LCD.
-
STANDARD
PICTURE RESET
Resets the following settings within the Display area of adjustment for dynamic contrast. All inputs except DVI...
Users Manual - Page 29
...SETTINGS: 1234567
ON: OFF: INPUT: PIC. Unlike CRT monitors, LCD monitors' image persistence is idle or turning off the monitor for as long as the previous image was on the screen. As with all personal display devices, NEC DISPLAY SOLUTIONS recommends displaying... the EVERY WEEK option and press SET.