NEC V461-2 Support and Manuals
Popular NEC V461-2 Manual Pages
P521 : WMK-3257 spec brochure - Page 1
...
Turn your mounting projects. Product specifications subject to put their display on center stage and, in .
8.3 lbs. 9.9 lbs. 90 days
NEC Displays Supported
NEC E Series 32" E321 42" E421 46" E461
NEC V Series 32" V321-2 42" V421-2 46" V461-2
NEC S Series 40" S401 46" S461 52" S521
NEC P Series 40" P401 46" P461 52" P521 55" P551
NEC X Series 46" X462UN 46" X461HB 43" X431BT (landscape only...
V321-2 : RS232 codes for V321, V421, V461 - Page 5
...
D1
Destination Address
41
D2
Header
Source Message
Address
type
30
45
D3
D4
Message length
30
41
D5
D6
Message
STX
OP code page
OP code
Set Value
Check code Delimiter ETX (BCC)
02 30 30 31 30 30 30 36 34 03 77
0D
D7
D8 D9 D10 D11 D12 D13 D14...
V321-2 : RS232 codes for V321, V421, V461 - Page 12
...code. The monitor replies with current Brightness setting and capability to support this byte is set to the section 4.5 "Check code" for confirmation.
(12/37) Message STX (02h): Start of Message
Check code
BCC: Block Check Code..., 35h, 30h): Set Brightness setting 80(0050h).
No error. '0'-'0' (30h, 30h): Operation code page number is 0. '1'-'0' (31h, 30h): Operation code is 18 bytes. ...
V321-2 : RS232 codes for V321, V421, V461 - Page 13
...4.5 "Check code" for reading the temperatures from the sensors. Message STX (02h): Start of Message
Check code
BCC: Block Check Code Refer to store the setting. MultiSync V321,V461 and LCD4215...code BCC
Delimiter CR
(13/37)
No error. '0'-'0' (30h, 30h): Operation code page number is 0. '1'-'0' (31h, 30h): Operation code is 10h (in the page 0). '0'-'0' (30h, 30h): This operation is "Set...
V321-2 : RS232 codes for V321, V421, V461 - Page 14
... of temperature sensors are 3 (0003h). '0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): temperature sensor is 18 bytes. No error. '0'-'2' (30h, 32h): Operation code page number is 2. '7'-'8' (37h, 38h): Operation code is 78h (in the page 2). '0'-'0' (30h, 30h): This operation is "Set parameter" type. '0'-'0'-'0'-'3' (30h, 30h, 30h, 33h): Number of Header '0' (30h): Reserved '0' (30h): Message receiver is...
V321-2 : RS232 codes for V321, V421, V461 - Page 15
...a BCC calculation.
Delimiter CR (0Dh): End of selected sensor.
No error. '0'-'2' (30h, 32h): Operation code page number is 2. '7'-'9' (37h, 39h): Operation code is 79h (in the page 2). Readout value is 79h (in the page 2). '0'-'0' (30h, 30h): This operation is "Set parameter" type. 'F'-'F'-'F'-'F' (46h, 46h, 46h, 46h): Maximum value. '0'-'0'-'3'-'2' (30h, 30h, 33h, 32h): The temperature...
V321-2 : RS232 codes for V321, V421, V461 - Page 17
...'N'-'N': Message length Note.) The maximum data length that can be written to the section 4.5 "Check code" for confirmation.
Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is ...0Dh): End of packet
7.2 Power control 1) The controller requests the monitor to change a setting. No error. 'C'-'2','0'-'3'-'D'-'6' (43h, 32h, 30h, 33h, 44h, 36h): power control reply command ...
V321-2 : RS232 codes for V321, V421, V461 - Page 19
...ID: Indicate a replying Monitor ID. No error. 'C'-'0'-'0'-'E' (43h, 30h, 30h, 45h...is '1'. 'B' (42h): Message type is 32bytes. Ex.) When this byte is set to the monitor at a time is "Command reply".
Ex.) If Monitor ID...Header SOH-'0'-Monitor ID-'0'-'A'-N-N
Message STX-'C'-'0'-'0'-'E'-'0'-'0'Data(0)-Data(1)---Data(N)-ETX
Check code BCC
Delimiter CR
Header SOH (01h): Start Of Header '0'...
V461-2 : install guide - Page 1
...with bars on the left or right, or stretched horizontally
to supply useful information for millimeters multiply by step procedure for installation. • Any ceilings or walls must be strong enough to support the monitor and the installation must be tilted in either normal aspect ratio with any local
building codes.
V461-2 Installation Guide
46" LCD Display
NEC Display Solutions of 9
V461-2 : install guide - Page 2
...covered, other means of ventilation will need to be incorporated into the design. If for some reason the opening .
NEC Display Solutions of 9 Contact NEC for proper ventilation. V461-2 Installation Guide
46" LCD Display
Ventilation Requirements (all models)
Dimensions below are minimum required for design review and recommendations.
www.necdisplay.com
V461-2
Page 2 of America, Inc.
V461-2 : install guide - Page 3
V461-2 Installation Guide
46" LCD Display
Display dimensions
NEC Display Solutions of 9 Rev 1.0
www.necdisplay.com
V461-2
Page 3 of America, Inc.
V461-2 : install guide - Page 4
Rev 1.0
www.necdisplay.com
V461-2
Page 4 of America, Inc. V461-2 Installation Guide
46" LCD Display
Display dimensions (cont.)
NEC Display Solutions of 9
V461-2 : install guide - Page 5
Rev 1.0
www.necdisplay.com
V461-2
Page 5 of America, Inc. V461-2 Installation Guide
46" LCD Display
Dimensions with included speakers
NEC Display Solutions of 9
NEC V461-2 Reviews
Do you have an experience with the NEC V461-2 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for NEC yet.
Earn 750 points for your review!