DA6490
Page 1
Product Dimensions DA 6480 30" Downdraft Ventilation Hood DA 6490 36" Downdraft Ventilation Hood Page 1 of the Appliance. Exhaust duct connection diameters DA 6480, DA 6490 with internal blower DA 6480, DA 6490 with local codes. All electrical work should be done in accordance with external blower DAG 500 Internal...33 1/16" (840 mm) H The hood requires a 120 VAC, 60 Hz, 15 A hard wire connection to scale Specification Sheets OJS 05152012 The blower box can also be mounted in such a way that the vent collar is not to the terminal. DA 6480 Shipping weight 44 lbs (20 kg) Shipping ...
Product Dimensions DA 6480 30" Downdraft Ventilation Hood DA 6490 36" Downdraft Ventilation Hood Page 1 of the Appliance. Exhaust duct connection diameters DA 6480, DA 6490 with internal blower DA 6480, DA 6490 with local codes. All electrical work should be done in accordance with external blower DAG 500 Internal...33 1/16" (840 mm) H The hood requires a 120 VAC, 60 Hz, 15 A hard wire connection to scale Specification Sheets OJS 05152012 The blower box can also be mounted in such a way that the vent collar is not to the terminal. DA 6480 Shipping weight 44 lbs (20 kg) Shipping ...
DA6490
Page 2
... and the front edge of the cooktop is not to the rear. Drawing is maintained. Exhaust duct connection diameters DA 6480, DA 6490 with internal blower DA 6480, DA 6490 with external blower DAG 500 Internal Blower - 6" Ø (150 mm) DAG 1000 External Blower- 10...is free of the ventilation system and the cooktop. Cut-out Dimensions DA 6480 30" Downdraft Ventilation Hood DA 6490 36" Downdraft Ventilation Hood Page 2 of kitchen cabinets, back splashes and/or racks in accordance with Miele CombiSet units The specified dimensions minimum cut-out dimensions must be done...
... and the front edge of the cooktop is not to the rear. Drawing is maintained. Exhaust duct connection diameters DA 6480, DA 6490 with internal blower DA 6480, DA 6490 with external blower DAG 500 Internal Blower - 6" Ø (150 mm) DAG 1000 External Blower- 10...is free of the ventilation system and the cooktop. Cut-out Dimensions DA 6480 30" Downdraft Ventilation Hood DA 6490 36" Downdraft Ventilation Hood Page 2 of kitchen cabinets, back splashes and/or racks in accordance with Miele CombiSet units The specified dimensions minimum cut-out dimensions must be done...
DA6490
Page 3
... being installed at the rear of the appliance, a cut-out must be made in accordance with local codes. Product and Cut-out Dimensions DA 6480 30" Downdraft Ventilation Hood DA 6490 36" Downdraft Ventilation Hood Page 3 of 7 Exhaust air ducting using the DAG 500 internal blower, installed on the front of the appliance [vent duct 6" ø (150 mm...
... being installed at the rear of the appliance, a cut-out must be made in accordance with local codes. Product and Cut-out Dimensions DA 6480 30" Downdraft Ventilation Hood DA 6490 36" Downdraft Ventilation Hood Page 3 of 7 Exhaust air ducting using the DAG 500 internal blower, installed on the front of the appliance [vent duct 6" ø (150 mm...
DA6490
Page 4
... load with interior mounted DAG 500 vent motor Page 4 of 7 DAG 500 mounted in accordance with local codes. Product and Cut-out Dimensions DA 6480 30" Downdraft Ventilation Hood DA 6490 36" Downdraft Ventilation Hood DAG 500 Internal Blower Shown with interior-mounted DAG 500 vent motor 420 W DAG 500 mounted behind the exhaust system. Drawing is not...
... load with interior mounted DAG 500 vent motor Page 4 of 7 DAG 500 mounted in accordance with local codes. Product and Cut-out Dimensions DA 6480 30" Downdraft Ventilation Hood DA 6490 36" Downdraft Ventilation Hood DAG 500 Internal Blower Shown with interior-mounted DAG 500 vent motor 420 W DAG 500 mounted behind the exhaust system. Drawing is not...
DA6490
Page 5
DAG 1000 External Blower exhaust diameter- 10" Ø (254 mm) Maximum Load with local codes. Product and Cut-out Dimensions DA 6480 30" Downdraft Ventilation Hood DA 6490 36" Downdraft Ventilation Hood DAG 1000 External Blower Installation using the external blower, install a connection cable between the ventilation system and the external blower. Note that the back must ...
DAG 1000 External Blower exhaust diameter- 10" Ø (254 mm) Maximum Load with local codes. Product and Cut-out Dimensions DA 6480 30" Downdraft Ventilation Hood DA 6490 36" Downdraft Ventilation Hood DAG 1000 External Blower Installation using the external blower, install a connection cable between the ventilation system and the external blower. Note that the back must ...
DA6490
Page 6
Product Dimensions DA 6480 30" Downdraft Ventilation Hood DA 6490 36" Downdraft Ventilation Hood DAG 1000 External Blower Page 6 of 7 ¾ Conduit Size 10" ø DAG 1000 External Blower exhaust diameter- 10" Ø (254 mm) Item 28996291USA - Drawing is not to scale Specification Sheets OJS 05152012 DAG 1000 Shipping weight 55 lbs (25 kg) Shipping dimensions 36 1/4" (920 mm) L x 13 1/4" (336 mm) W x 30" (762 mm) H All installations must be done in accordance with local codes.
Product Dimensions DA 6480 30" Downdraft Ventilation Hood DA 6490 36" Downdraft Ventilation Hood DAG 1000 External Blower Page 6 of 7 ¾ Conduit Size 10" ø DAG 1000 External Blower exhaust diameter- 10" Ø (254 mm) Item 28996291USA - Drawing is not to scale Specification Sheets OJS 05152012 DAG 1000 Shipping weight 55 lbs (25 kg) Shipping dimensions 36 1/4" (920 mm) L x 13 1/4" (336 mm) W x 30" (762 mm) H All installations must be done in accordance with local codes.
DA6490
Page 7
Drawing is 180° Two - DKF 18-1 Charcoal filters included Page 7 of cabinet. 5 7/8" Vent port can be done in 3 positions Discharge Grill exhaust is not to scale Specification Sheets OJS 05152012 Product and Cut-out Dimensions DA 6480 30" Downdraft Ventilation Hood DA 6490 36" Downdraft Ventilation Hood Downdraft Recirculation Kit DUU 2900 2 3 1 Details Item 09162160 Cabinet cut-out 15 7/16" x 8 13/16" (392 mm x 224 mm) To be vented out the sides or base of 7 All installations must be mounted in accordance with local codes. Item number 09162160 -
Drawing is 180° Two - DKF 18-1 Charcoal filters included Page 7 of cabinet. 5 7/8" Vent port can be done in 3 positions Discharge Grill exhaust is not to scale Specification Sheets OJS 05152012 Product and Cut-out Dimensions DA 6480 30" Downdraft Ventilation Hood DA 6490 36" Downdraft Ventilation Hood Downdraft Recirculation Kit DUU 2900 2 3 1 Details Item 09162160 Cabinet cut-out 15 7/16" x 8 13/16" (392 mm x 224 mm) To be vented out the sides or base of 7 All installations must be mounted in accordance with local codes. Item number 09162160 -