Operating and Installation manual
Page 1
US, CA M.-Nr. 09 045 140 en - Operating and Installation Instructions Downdraft Ventilation System DA 6480, DA 6490 DAG 500, DAG 1000 To prevent accidents and appliance damage, read these instructions before installation or use.
US, CA M.-Nr. 09 045 140 en - Operating and Installation Instructions Downdraft Ventilation System DA 6480, DA 6490 DAG 500, DAG 1000 To prevent accidents and appliance damage, read these instructions before installation or use.
Operating and Installation manual
Page 2
Contents IMPORTANT SAFETY INSTRUCTIONS 3 Functional description 7 Description of the appliance 8 Operation 10 Raising the vent / Turning on the fan 10 Selecting the power level 10 Delayed shut-off feature ¢15 10 Temperature warning 11 Cleaning and Care 12 Grease filters 13 After Sales Service 15 Installation instructions 17 Caring for the environment 19 Appliance dimensions 20 Installation 26 Installation with the DAG 1000 external blower 34 Air extraction 35 Electrical connection 37 2
Contents IMPORTANT SAFETY INSTRUCTIONS 3 Functional description 7 Description of the appliance 8 Operation 10 Raising the vent / Turning on the fan 10 Selecting the power level 10 Delayed shut-off feature ¢15 10 Temperature warning 11 Cleaning and Care 12 Grease filters 13 After Sales Service 15 Installation instructions 17 Caring for the environment 19 Appliance dimensions 20 Installation 26 Installation with the DAG 1000 external blower 34 Air extraction 35 Electrical connection 37 2
Operating and Installation manual
Page 7
Functional description The ventilation system offers two installation options: with the internal DAG 500 exhaust blower (not included) with the DAG 1000 external blower (not included) The air is designed to the ventilation system by a control cable, and exhaust ductwork and is drawn through and cleaned by ...
Functional description The ventilation system offers two installation options: with the internal DAG 500 exhaust blower (not included) with the DAG 1000 external blower (not included) The air is designed to the ventilation system by a control cable, and exhaust ductwork and is drawn through and cleaned by ...
Operating and Installation manual
Page 21
Must be mounted in the same position on the rear of the cabinet or wall. Exhaust duct connection diameters DA 6480, 6490 with internal blower DAG 500 6" C (150 mm) DA 6480, 6490 with external blower DAG 1000 10" C (254 mm) Appliance dimensions 21 a DAG 500 Internal blower The blower box can also be mounted in such... to the rear of the appliance. x = Distance to the left, the right, downwards or towards the rear, as desired. b Connection plate when using the DAG 1000 external blower The blower or the connection plate can be a minimum of ½" (13 mm).
Must be mounted in the same position on the rear of the cabinet or wall. Exhaust duct connection diameters DA 6480, 6490 with internal blower DAG 500 6" C (150 mm) DA 6480, 6490 with external blower DAG 1000 10" C (254 mm) Appliance dimensions 21 a DAG 500 Internal blower The blower box can also be mounted in such... to the rear of the appliance. x = Distance to the left, the right, downwards or towards the rear, as desired. b Connection plate when using the DAG 1000 external blower The blower or the connection plate can be a minimum of ½" (13 mm).
Operating and Installation manual
Page 23
d Feed the power cord and control cable when using the DAG 500 internal blower, installed on the front of the cooktop: DA 6480: 28" (711 mm) DA 6490: 34" (864 mm) - The specified dimensions minimum cut-out dimensions must be observed. - The front panel of the ventilation system and the ...cooktop. e Using the DAG 1000 external blower, install exhaust ducting to the rear (vent duct 10" C (254 mm)). If installing the exhaust ...
d Feed the power cord and control cable when using the DAG 500 internal blower, installed on the front of the cooktop: DA 6480: 28" (711 mm) DA 6490: 34" (864 mm) - The specified dimensions minimum cut-out dimensions must be observed. - The front panel of the ventilation system and the ...cooktop. e Using the DAG 1000 external blower, install exhaust ducting to the rear (vent duct 10" C (254 mm)). If installing the exhaust ...
Operating and Installation manual
Page 25
Exhaust air ducting to the front. Note that the back must be accessible for the installation of the vent duct. 25 Appliance dimensions Installation using the DAG 1000 external blower connection plate Exhaust air ducting to the rear.
Exhaust air ducting to the front. Note that the back must be accessible for the installation of the vent duct. 25 Appliance dimensions Installation using the DAG 1000 external blower connection plate Exhaust air ducting to the rear.
Operating and Installation manual
Page 28
... duct can go through the floor, the right or left , right or downwards. ^ Mount the blower box to mount the DAG 500 blower or DAG 1000 blower adapter.
... duct can go through the floor, the right or left , right or downwards. ^ Mount the blower box to mount the DAG 500 blower or DAG 1000 blower adapter.
Operating and Installation manual
Page 34
... mounted on the front, the exhaust can only be connected in the housing as described for the blower box. ^ Plug the connector for the DAG 1000. The control cable will be vented to the external blower by a C 10" (254 mm) vent duct. 34 It can only be vented to the rear... mounted on the rear, the exhaust can be installed on the ventilation system instead of the blower box. Installation Installation with the DAG 1000 external blower If using DAG 1000 external blower, a connection plate much be mounted on either on the front or the rear of the appliance. If the connection plate...
... mounted on the front, the exhaust can only be connected in the housing as described for the blower box. ^ Plug the connector for the DAG 1000. The control cable will be vented to the external blower by a C 10" (254 mm) vent duct. 34 It can only be vented to the rear... mounted on the rear, the exhaust can be installed on the ventilation system instead of the blower box. Installation Installation with the DAG 1000 external blower If using DAG 1000 external blower, a connection plate much be mounted on either on the front or the rear of the appliance. If the connection plate...
Operating and Installation manual
Page 37
...Black wire connect to N (neutral) Green-yellow wire: . . . connect to your power supply, please consult a licensed electrician or contact Miele's Technical Service Department. Ensure that power to the appliance is off while installation or repair work by a qualified electrician in strict accordance with... Miele DAG 500 or DAG 1000 blowers. ^ Verify that the voltage, load and circuit rating information found on the data plate, match the household electrical...
...Black wire connect to N (neutral) Green-yellow wire: . . . connect to your power supply, please consult a licensed electrician or contact Miele's Technical Service Department. Ensure that power to the appliance is off while installation or repair work by a qualified electrician in strict accordance with... Miele DAG 500 or DAG 1000 blowers. ^ Verify that the voltage, load and circuit rating information found on the data plate, match the household electrical...
Operating and Installation manual
Page 38
... cable. ^ Close the terminal box. ^ Turn the power supply back on. Maximum load with interior-mounted DAG 500 vent motor 420 W with exterior-mounted DAG 1000 vent motor 210 W Voltage 120 V Frequency 60 Hz Circuit Rating 15 A ^ Additional housing knock-outs should be connected to the power supply as described previously...
... cable. ^ Close the terminal box. ^ Turn the power supply back on. Maximum load with interior-mounted DAG 500 vent motor 420 W with exterior-mounted DAG 1000 vent motor 210 W Voltage 120 V Frequency 60 Hz Circuit Rating 15 A ^ Additional housing knock-outs should be connected to the power supply as described previously...
DA6490
Page 1
... with external blower DAG 500 Internal Blower - 6" Ø (150 mm) DAG 1000 External Blower- 10" Ø (254 mm) Item 28648050USA - Exhaust duct connection diameters DA 6480, DA 6490 with internal blower DA 6480, DA 6490 with local codes. All installations must be a minimum of the Appliance. Must ... that the vent collar is not to the left, the right, downwards or towards the rear, as desired. 2 Connection plate when using the DAG 1000 external blower. DA 6480 Shipping weight 44 lbs (20 kg) Shipping dimensions 31 5/16" (795 mm) L x 8 1/4" (210 mm) W x 33 1/16" (840...
... with external blower DAG 500 Internal Blower - 6" Ø (150 mm) DAG 1000 External Blower- 10" Ø (254 mm) Item 28648050USA - Exhaust duct connection diameters DA 6480, DA 6490 with internal blower DA 6480, DA 6490 with local codes. All installations must be a minimum of the Appliance. Must ... that the vent collar is not to the left, the right, downwards or towards the rear, as desired. 2 Connection plate when using the DAG 1000 external blower. DA 6480 Shipping weight 44 lbs (20 kg) Shipping dimensions 31 5/16" (795 mm) L x 8 1/4" (210 mm) W x 33 1/16" (840...
DA6490
Page 2
...external blower downwards or to the rear. Drawing is maintained. Exhaust duct connection diameters DA 6480, DA 6490 with internal blower DA 6480, DA 6490 with external blower DAG 500 Internal Blower - 6" Ø (150 mm) DAG 1000 External Blower- 10" Ø (254 mm) Notes: Not to be used ... B - If an oven is free of the ventilation system, ensure that the area where the vent rises is installed in accordance with Miele CombiSet units The specified dimensions minimum cut-out dimensions must be observed. Cooktop Minimum Width DA6480: 28" (711 mm) DA6490: 34" ...
...external blower downwards or to the rear. Drawing is maintained. Exhaust duct connection diameters DA 6480, DA 6490 with internal blower DA 6480, DA 6490 with external blower DAG 500 Internal Blower - 6" Ø (150 mm) DAG 1000 External Blower- 10" Ø (254 mm) Notes: Not to be used ... B - If an oven is free of the ventilation system, ensure that the area where the vent rises is installed in accordance with Miele CombiSet units The specified dimensions minimum cut-out dimensions must be observed. Cooktop Minimum Width DA6480: 28" (711 mm) DA6490: 34" ...
DA6490
Page 5
... for installation of the venting ductwork If using the DAG 1000 external blower connection plate Page 5 of 7 Exhaust air ducting to the front. Exhaust air ducting to scale Specification Sheets OJS 05152012 DAG 1000 External Blower exhaust diameter- 10" Ø (254 mm...) Maximum Load with exterior-mounted DAG 1000 vent motor 210 W All installations must be done in accordance with local codes. Product and Cut-out Dimensions DA 6480 30" Downdraft Ventilation Hood DA 6490 36" Downdraft Ventilation Hood DAG 1000 External Blower Installation using the external blower, install...
... for installation of the venting ductwork If using the DAG 1000 external blower connection plate Page 5 of 7 Exhaust air ducting to the front. Exhaust air ducting to scale Specification Sheets OJS 05152012 DAG 1000 External Blower exhaust diameter- 10" Ø (254 mm...) Maximum Load with exterior-mounted DAG 1000 vent motor 210 W All installations must be done in accordance with local codes. Product and Cut-out Dimensions DA 6480 30" Downdraft Ventilation Hood DA 6490 36" Downdraft Ventilation Hood DAG 1000 External Blower Installation using the external blower, install...
DA6490
Page 6
Product Dimensions DA 6480 30" Downdraft Ventilation Hood DA 6490 36" Downdraft Ventilation Hood DAG 1000 External Blower Page 6 of 7 ¾ Conduit Size 10" ø DAG 1000 External Blower exhaust diameter- 10" Ø (254 mm) Item 28996291USA - Drawing is not to scale Specification Sheets OJS 05152012 DAG 1000 Shipping weight 55 lbs (25 kg) Shipping dimensions 36 1/4" (920 mm) L x 13 1/4" (336 mm) W x 30" (762 mm) H All installations must be done in accordance with local codes.
Product Dimensions DA 6480 30" Downdraft Ventilation Hood DA 6490 36" Downdraft Ventilation Hood DAG 1000 External Blower Page 6 of 7 ¾ Conduit Size 10" ø DAG 1000 External Blower exhaust diameter- 10" Ø (254 mm) Item 28996291USA - Drawing is not to scale Specification Sheets OJS 05152012 DAG 1000 Shipping weight 55 lbs (25 kg) Shipping dimensions 36 1/4" (920 mm) L x 13 1/4" (336 mm) W x 30" (762 mm) H All installations must be done in accordance with local codes.