...through microphone are ignored by heavy duty,anti-reflection scratch resistant glass. Telephone line port - PRODUCT OVERVIEW STANDARD FEATURES • Twenty Six line... • Surge protection; - 6000V, 3000A - Battery backup for complete function for keyless entry. - 60 Utility key codes available per transaction. • (Optional) camera for security ..."Templates". • Standard I HE P T U Y J H G N F B V C O K M P L PCCKE ' Icon Page 3 3 Year Warranty Factory to +165 F (Heater kit available at additional cost.) - Talk time is rain resistant. • Power ...
...through microphone are ignored by heavy duty,anti-reflection scratch resistant glass. Telephone line port - PRODUCT OVERVIEW STANDARD FEATURES • Twenty Six line... • Surge protection; - 6000V, 3000A - Battery backup for complete function for keyless entry. - 60 Utility key codes available per transaction. • (Optional) camera for security ..."Templates". • Standard I HE P T U Y J H G N F B V C O K M P L PCCKE ' Icon Page 3 3 Year Warranty Factory to +165 F (Heater kit available at additional cost.) - Talk time is rain resistant. • Power ...
ICON26 Manual
Page 13
...: Connect to corresponding RS485 terminals (-, +, GND) of remote security devices. 8 CHASSIS GROUND: Entry Phone MUST be properly grounded. Each time access is granted, the VCR relay is properly grounded.... is activated for 5 seconds, allowing recording of a postal lock or exit switch. CHASSIS GROUND 8 3 TELEPHONE LINE: Tip and Ring Connection. OUT Auxiliary Input 1-IN activates auxiliary Relay 1 (+) (-) GND RS-485...Input 2-IN activates auxiliary Relay 2 2 POWER IN: 12 Vac to the ground rod. Icon Page 12 18 POWER LED: Indicates Phone system has 12 Vac power present. DESCRIPTION OF ...
...: Connect to corresponding RS485 terminals (-, +, GND) of remote security devices. 8 CHASSIS GROUND: Entry Phone MUST be properly grounded. Each time access is granted, the VCR relay is properly grounded.... is activated for 5 seconds, allowing recording of a postal lock or exit switch. CHASSIS GROUND 8 3 TELEPHONE LINE: Tip and Ring Connection. OUT Auxiliary Input 1-IN activates auxiliary Relay 1 (+) (-) GND RS-485...Input 2-IN activates auxiliary Relay 2 2 POWER IN: 12 Vac to the ground rod. Icon Page 12 18 POWER LED: Indicates Phone system has 12 Vac power present. DESCRIPTION OF ...
ICON26 Manual
Page 15
... single, whole piece of wire. For the correct wire gauge, consult the local code The ground wire must be directed towards the Telephone Entry System. Without this path, the intense energy generated by region. Before digging, contact local underground utility locating companies. EARTH GROUND ROD ...the ground wire too short, break it with all necessary local building codes. For the correct diameter, consult the local code Icon Page 14 Never splice two wires for correct grounding materials and installation procedures. For the correct depth consult the local code Not...
... single, whole piece of wire. For the correct wire gauge, consult the local code The ground wire must be directed towards the Telephone Entry System. Without this path, the intense energy generated by region. Before digging, contact local underground utility locating companies. EARTH GROUND ROD ...the ground wire too short, break it with all necessary local building codes. For the correct diameter, consult the local code Icon Page 14 Never splice two wires for correct grounding materials and installation procedures. For the correct depth consult the local code Not...
ICON26 Manual
Page 16
... Closed Pedestrian Gate Maglock Conduit Conduit Master Gate Operator (Strike Open Input) Access Door Solenoid OR OR Entry Door Maglock Dial Dial Connect two wires to the secondary gate or door. Icon Page 15 BASIC WIRING DIAGRAM 2-NO 2-NC 2-COM 1-NO 1-NC 1-COM GND 2-IN 1-IN... 185 Ft 345 Ft A1C2VDC POWER IN It is MANDATORY that this unit is properly Vehicular Gate Entry 1 Gate Relay Terminal Connection Normally Open Removable Screw Terminal Connectors for the Telephone Entry System unit ONLY! The gate relay will be activated by either pressing 5 on the resident's ...
... Closed Pedestrian Gate Maglock Conduit Conduit Master Gate Operator (Strike Open Input) Access Door Solenoid OR OR Entry Door Maglock Dial Dial Connect two wires to the secondary gate or door. Icon Page 15 BASIC WIRING DIAGRAM 2-NO 2-NC 2-COM 1-NO 1-NC 1-COM GND 2-IN 1-IN... 185 Ft 345 Ft A1C2VDC POWER IN It is MANDATORY that this unit is properly Vehicular Gate Entry 1 Gate Relay Terminal Connection Normally Open Removable Screw Terminal Connectors for the Telephone Entry System unit ONLY! The gate relay will be activated by either pressing 5 on the resident's ...
ICON26 Manual
Page 18
...according to the programmed "Gate Strike Time". 6 Test operation by application to the postal/exit connector on each of the four studs. Icon Page 17 Postal Lock Switch Assembly Switch Assembly Mounting Holes (Mount with the sliding bolt oriented away from the postal lock switch to your...unit is not grounded, lightning damage Installation: 1 Open the front panel of the Telephone Entry System and remove the hole plug. 2 (Retain nuts and washers) Install the postal lock with Postal Lock on Entry Phone Front Panel) Stainless Steel Front Panel of the sliding bolt will activate the ...
...according to the programmed "Gate Strike Time". 6 Test operation by application to the postal/exit connector on each of the four studs. Icon Page 17 Postal Lock Switch Assembly Switch Assembly Mounting Holes (Mount with the sliding bolt oriented away from the postal lock switch to your...unit is not grounded, lightning damage Installation: 1 Open the front panel of the Telephone Entry System and remove the hole plug. 2 (Retain nuts and washers) Install the postal lock with Postal Lock on Entry Phone Front Panel) Stainless Steel Front Panel of the sliding bolt will activate the ...
ICON26 Manual
Page 19
... superior data transmission) • Up to 31 RS485 devices supported • Maximum distance from the last RS485 device (per wire run) to the Telephone Entry Syetem is 4000 Ft. Icon Page 18 Turn Terminator Switch "ON" for Last Device on Wire Run - + Gnd Wire Run Turn Terminator Switch "ON" for Last Device on... using the rotary switches on Wire Run • Maximum number of wire runs allowed is 7 • Maximum distance from the last RS485 device to the Telephone Entry System is 31. • Use 22 AWG twisted pair shielded wire 4000 Ft Max.
... superior data transmission) • Up to 31 RS485 devices supported • Maximum distance from the last RS485 device (per wire run) to the Telephone Entry Syetem is 4000 Ft. Icon Page 18 Turn Terminator Switch "ON" for Last Device on Wire Run - + Gnd Wire Run Turn Terminator Switch "ON" for Last Device on... using the rotary switches on Wire Run • Maximum number of wire runs allowed is 7 • Maximum distance from the last RS485 device to the Telephone Entry System is 31. • Use 22 AWG twisted pair shielded wire 4000 Ft Max.
ICON26 Manual
Page 23
Do not drop the Processor or expose it to rain, snow, or harsh weather conditions. WARNINGS AND PRECAUTIONS 500 Do not touch the terminals on the RAM Cards. Do not expose the Processor Unit or the open Processor Containment Box to impact. ENTER ERASE EXIT Q PROGRAM E W S R D SHIFT A Z X SPACE BAR 3 1 4 2 5 8 6 9 7 0 I HELP T U Y J H G N F B V C O K M P L BSAPACCKE ' The Telephone Entry System is only water resistant when the Stainless Steel Door is closed and locked. Icon Page 22 Do not bend, drop or expose to impact.
Do not drop the Processor or expose it to rain, snow, or harsh weather conditions. WARNINGS AND PRECAUTIONS 500 Do not touch the terminals on the RAM Cards. Do not expose the Processor Unit or the open Processor Containment Box to impact. ENTER ERASE EXIT Q PROGRAM E W S R D SHIFT A Z X SPACE BAR 3 1 4 2 5 8 6 9 7 0 I HELP T U Y J H G N F B V C O K M P L BSAPACCKE ' The Telephone Entry System is only water resistant when the Stainless Steel Door is closed and locked. Icon Page 22 Do not bend, drop or expose to impact.