GT- Logic 4 Installation Manual
Page 2
...8 Assemble the Operator (Model APT 9 TYPICAL INSTALLATION 10-12 Install the Header Bracket 10 Attach the Track to the Header Bracket 11 Hang the Operator 11 Attach the Door Arm 12 HOIST AND JACKSHAFT OPERATORS ... 18 Control Station 19 ENTRAPMENT PROTECTION 20-22 LiftMaster Monitored Entrapment Protection (LMEP 20 Install the Photoelectric Sensors (Provided 21 Mount the ... GT and T 26 Emergency Disconnect System Model APT 26 Emergency Disconnect System Model H, GH, J, and HJ 27 PROGRAMMING 28-35 Introduction to Order Repair Parts 36 TROUBLESHOOTING 37...
...8 Assemble the Operator (Model APT 9 TYPICAL INSTALLATION 10-12 Install the Header Bracket 10 Attach the Track to the Header Bracket 11 Hang the Operator 11 Attach the Door Arm 12 HOIST AND JACKSHAFT OPERATORS ... 18 Control Station 19 ENTRAPMENT PROTECTION 20-22 LiftMaster Monitored Entrapment Protection (LMEP 20 Install the Photoelectric Sensors (Provided 21 Mount the ... GT and T 26 Emergency Disconnect System Model APT 26 Emergency Disconnect System Model H, GH, J, and HJ 27 PROGRAMMING 28-35 Introduction to Order Repair Parts 36 TROUBLESHOOTING 37...
GT- Logic 4 Installation Manual
Page 3
... door. • out of reach of children at minimum height of 5 feet (1.5 m). • away from the door. 11. Place manual release/safety reverse test label in contact with the door while operating the controls. 10. WARNING • DO NOT attempt repair or service of installation, test entrapment protection device. 13. Make sure...
... door. • out of reach of children at minimum height of 5 feet (1.5 m). • away from the door. 11. Place manual release/safety reverse test label in contact with the door while operating the controls. 10. WARNING • DO NOT attempt repair or service of installation, test entrapment protection device. 13. Make sure...
GT- Logic 4 Installation Manual
Page 4
... LIMIT ADJUST Linear driven, fully adjustable screw type cams. Adjustable to provide non-contact safety protection. ENTRAPMENT PROTECTION: LiftMaster Monitored Entrapment Protection (LMEP) Photoelectric Sensors (CPS-U Through beam used to 24 feet. Safety Edge (Optional Electric...230/460/575V 3 Phase CURRENT (Amperage): Model T and GT Voltage-Phase 1/3 HP 1/2 HP 3/4 HP 1 HP 1-1/2 HP 115-1Ø, 60Hz 8.5 11.2 13.6 16 20 230-1Ø, 60Hz 4.2 5.6 6.8 8 10 208/230-3Ø, 60Hz 3 3.1 4 6 7 460-3Ø, 60Hz 1.5 1.75 2 3 3.5 575-3Ø, 60Hz 1.3 1.4 1.6 1.8 2.75 ...
... LIMIT ADJUST Linear driven, fully adjustable screw type cams. Adjustable to provide non-contact safety protection. ENTRAPMENT PROTECTION: LiftMaster Monitored Entrapment Protection (LMEP) Photoelectric Sensors (CPS-U Through beam used to 24 feet. Safety Edge (Optional Electric...230/460/575V 3 Phase CURRENT (Amperage): Model T and GT Voltage-Phase 1/3 HP 1/2 HP 3/4 HP 1 HP 1-1/2 HP 115-1Ø, 60Hz 8.5 11.2 13.6 16 20 230-1Ø, 60Hz 4.2 5.6 6.8 8 10 208/230-3Ø, 60Hz 3 3.1 4 6 7 460-3Ø, 60Hz 1.5 1.75 2 3 3.5 575-3Ø, 60Hz 1.3 1.4 1.6 1.8 2.75 ...
GT- Logic 4 Installation Manual
Page 6
TROLLEY WEIGHTS AND DIMENSIONS MODELS T AND APT Hanging Weight: 80-110 lbs. 4" (10.16 cm) 14" (35.56 cm) *Door Height Plus 4 feet (minimum) Highest Point of Door Travel 11.63" (29.54 cm) *23.43" (59.51 cm) *- Optional on APT, T 3/4 and T 1 HP models; For Units with Brake add 3-1/2" (Standard on T 1/3 and 1/2 HP models) MODEL GT Hanging Weight: 140 lbs. 4" (10.16 cm) Door Height Plus 4 feet (minimum) 13.05" (33.15 cm) * 17.5" (44.45 cm) 18.5" (46.99 cm) Weights and dimensions - Trolley 6
TROLLEY WEIGHTS AND DIMENSIONS MODELS T AND APT Hanging Weight: 80-110 lbs. 4" (10.16 cm) 14" (35.56 cm) *Door Height Plus 4 feet (minimum) Highest Point of Door Travel 11.63" (29.54 cm) *23.43" (59.51 cm) *- Optional on APT, T 3/4 and T 1 HP models; For Units with Brake add 3-1/2" (Standard on T 1/3 and 1/2 HP models) MODEL GT Hanging Weight: 140 lbs. 4" (10.16 cm) Door Height Plus 4 feet (minimum) 13.05" (33.15 cm) * 17.5" (44.45 cm) 18.5" (46.99 cm) Weights and dimensions - Trolley 6
GT- Logic 4 Installation Manual
Page 13
... 29 for manual door operation Model HJ Includes both floor level disconnect systems stated above ENTRAPMENT PROTECTION: LiftMaster Monitored Entrapment Protection (LMEP) Photoelectric Sensors (CPS-U Through beam used to the bottom edge of door...3 3.1 4 6 460-3Ø, 60Hz 1.5 1.75 2 3 575-3Ø, 60Hz 1.3 1.4 1.6 1.8 Model GH Voltage-Phase 1/2 HP 3/4 HP 1 HP 1-1/2 HP 2 HP 3 HP 115-1Ø, 60Hz 11.2 13.6 16 20 - - 230-1Ø, 60Hz 5.6 6.8 8 10 - - 208/230-3Ø, 60Hz 3.1 4 6 7 8 10.6 460-3Ø, 60Hz 1.75 2 3 3.5 4 4.8 575-3Ø, 60Hz 1.4 1.6 1.8 2.75 3 -...
... 29 for manual door operation Model HJ Includes both floor level disconnect systems stated above ENTRAPMENT PROTECTION: LiftMaster Monitored Entrapment Protection (LMEP) Photoelectric Sensors (CPS-U Through beam used to the bottom edge of door...3 3.1 4 6 460-3Ø, 60Hz 1.5 1.75 2 3 575-3Ø, 60Hz 1.3 1.4 1.6 1.8 Model GH Voltage-Phase 1/2 HP 3/4 HP 1 HP 1-1/2 HP 2 HP 3 HP 115-1Ø, 60Hz 11.2 13.6 16 20 - - 230-1Ø, 60Hz 5.6 6.8 8 10 - - 208/230-3Ø, 60Hz 3.1 4 6 7 8 10.6 460-3Ø, 60Hz 1.75 2 3 3.5 4 4.8 575-3Ø, 60Hz 1.4 1.6 1.8 2.75 3 -...
GT- Logic 4 Installation Manual
Page 19
... by a pause, call for routine door maintenance. ENCIA CIÓN 3 5' 5 1 2 4 24VAC 14 24VAC DATA 13 TIMER ^OPEN DEFEAT 12 ^ CLOSE O COMMON 11 STOP 24VAC POWER 24VAC TIMER DEFEAT MAS 10 COMMON MAS LMEP 9 LMEP: TIMER NABLE EDGE: OPEN EDGE 8 CLOSE OPEN ADVERTSTOP ENCIA 7 COMMON CLOSE 6 N STOP 5 ADVERTENCIA SBC COMMON 4 UL Entrapment Placard...
... by a pause, call for routine door maintenance. ENCIA CIÓN 3 5' 5 1 2 4 24VAC 14 24VAC DATA 13 TIMER ^OPEN DEFEAT 12 ^ CLOSE O COMMON 11 STOP 24VAC POWER 24VAC TIMER DEFEAT MAS 10 COMMON MAS LMEP 9 LMEP: TIMER NABLE EDGE: OPEN EDGE 8 CLOSE OPEN ADVERTSTOP ENCIA 7 COMMON CLOSE 6 N STOP 5 ADVERTENCIA SBC COMMON 4 UL Entrapment Placard...
GT- Logic 4 Installation Manual
Page 23
... may cause SEVERE INJURY and DEATH. 9. SAVE THESE INSTRUCTIONS. ALL repairs to adjust the operator properly may cause SEVERE INJURY and DEATH. 10. See door manufacturer's owners manual. 11. NEVER permit children to door operator BEFORE making ANY repairs or removing covers. 13. Failure to cables, spring assemblies and other hardware, ALL...
... may cause SEVERE INJURY and DEATH. 9. SAVE THESE INSTRUCTIONS. ALL repairs to adjust the operator properly may cause SEVERE INJURY and DEATH. 10. See door manufacturer's owners manual. 11. NEVER permit children to door operator BEFORE making ANY repairs or removing covers. 13. Failure to cables, spring assemblies and other hardware, ALL...
GT- Logic 4 Installation Manual
Page 44
... proper installation and operation with the Commercial Door Operator. 3 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER AND STOP BUTTON STANDARD 10 7 6 4 5 2 OR MORE 10 7 6 4 5 KEY LOCKOUT 10 7 6 4 5 (RED) Maintenance Alert LED (WHITE) Open Close Stop (RED) Maintenance Alert LED (WHITE) (RED) Open Open Maintenance... NOTES: 1. If a STOP button is Used 2 3 2 3 01-35241D Sensing Device ONE © 2010, The Chamberlain Group, Inc. Any Commercial Type LiftMaster Brand Receiver SENSING DEVICE TO REVERSE OR STOP Note: 11 and 4 are both the same common.
... proper installation and operation with the Commercial Door Operator. 3 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER AND STOP BUTTON STANDARD 10 7 6 4 5 2 OR MORE 10 7 6 4 5 KEY LOCKOUT 10 7 6 4 5 (RED) Maintenance Alert LED (WHITE) Open Close Stop (RED) Maintenance Alert LED (WHITE) (RED) Open Open Maintenance... NOTES: 1. If a STOP button is Used 2 3 2 3 01-35241D Sensing Device ONE © 2010, The Chamberlain Group, Inc. Any Commercial Type LiftMaster Brand Receiver SENSING DEVICE TO REVERSE OR STOP Note: 11 and 4 are both the same common.
GT- Logic 4 User Manual
Page 5
permit anyone to cross path of time to 11 and 12 (Common and Timer Defeat). AVERTISSEMENT PROGRAM, press... timer. ADVERTENCIA 4. BASIC PROGRAMMING WARNING W To prevent possible SEVERE INJURY or DEATH: CAUTION • Install a LiftMaster Monitored Entrapment Protection (LMEP) • Activate door ONLY when it can be set to clear the timer. 5....button to TS, T or FSTS. Close the door. 2. The OPEN LED Operation will flash once for 10 seconds. CLOSE button four times for every 15 seconds programmed. automatically after preset amount of time. 7. Example:...
permit anyone to cross path of time to 11 and 12 (Common and Timer Defeat). AVERTISSEMENT PROGRAM, press... timer. ADVERTENCIA 4. BASIC PROGRAMMING WARNING W To prevent possible SEVERE INJURY or DEATH: CAUTION • Install a LiftMaster Monitored Entrapment Protection (LMEP) • Activate door ONLY when it can be set to clear the timer. 5....button to TS, T or FSTS. Close the door. 2. The OPEN LED Operation will flash once for 10 seconds. CLOSE button four times for every 15 seconds programmed. automatically after preset amount of time. 7. Example:...
GT- Logic 4 User Manual
Page 11
... of use with the approved 4-wire safety edge (see beloOPwEN ). For use with wall-mounted J, H, GH, DH or DJ operators. Cast iron bracket to 45' wide. CLOSE Heavy gauge steel bracket for maximum ...for ease of coil on doors up reel (20' extended) and 14' air hose. 10-12360 08-9098 08-9098EZ 1A4324 1A4324EZ Heavy gauge steel bracket for damp environments where direct ...provides special functionality to activate and flash auxiliary devices such as 71-6023, but for 1-1/4" shafts. 11 Fits between operator shaft and door shaft. 71-6125 Same as lights, bells, and horns/strobes...
... of use with the approved 4-wire safety edge (see beloOPwEN ). For use with wall-mounted J, H, GH, DH or DJ operators. Cast iron bracket to 45' wide. CLOSE Heavy gauge steel bracket for maximum ...for ease of coil on doors up reel (20' extended) and 14' air hose. 10-12360 08-9098 08-9098EZ 1A4324 1A4324EZ Heavy gauge steel bracket for damp environments where direct ...provides special functionality to activate and flash auxiliary devices such as 71-6023, but for 1-1/4" shafts. 11 Fits between operator shaft and door shaft. 71-6125 Same as lights, bells, and horns/strobes...
GT Logic 4-Repair Parts Manual
Page 1
... Operators Models T, GT, APT, SD, GSD and GH Individual Parts ITEM PART# DESCRIPTION 1 13-10024 2 23-10041 3 K75-35627 4 21-14182 21-35057 21-35077 5 29-31244 6 29-31245 29-31229 7 K74-31243 8 K79-15016-1 9 K1A6837 10 K2A761 11 K1C3196-3 12 42-31247 13 42-10040 Limit Nut Limit...Limit Shaft, Limit Nuts, Limit Bearings, Limit Sprocket, Interrupter Cup, Shim Washers, Compression Ring, Roll Pin and E-Rings. 1-800-528-2806 www.liftmaster.com Electrical Box Electrical Box Replacement Kits To order a complete electrical box replacement kit, add a K-Prefix to the model number of your operator for...
... Operators Models T, GT, APT, SD, GSD and GH Individual Parts ITEM PART# DESCRIPTION 1 13-10024 2 23-10041 3 K75-35627 4 21-14182 21-35057 21-35077 5 29-31244 6 29-31245 29-31229 7 K74-31243 8 K79-15016-1 9 K1A6837 10 K2A761 11 K1C3196-3 12 42-31247 13 42-10040 Limit Nut Limit...Limit Shaft, Limit Nuts, Limit Bearings, Limit Sprocket, Interrupter Cup, Shim Washers, Compression Ring, Roll Pin and E-Rings. 1-800-528-2806 www.liftmaster.com Electrical Box Electrical Box Replacement Kits To order a complete electrical box replacement kit, add a K-Prefix to the model number of your operator for...
GT Logic 4-Repair Parts Manual
Page 2
... 7 16-5L300 Cogged Belt 8 17-10165 5L Motor Pulley 7" O.D. 9 18-10164 Clutch Spring (1/3 & 1/2 HP) 18-10168 Clutch Spring (3/4 & 1 HP) 10 39-10167 Clutch Disc 11 87-P-075 Push on Fastener 12 12-10331 Flange Bearing 13 15-41B10G1 Sprocket, 41B10x3/4" (3/4 & 1 HP) 15-48B10GXX Sprocket, 41B10x3/4" (1/3 & 1/2 HP) 14 15...HP 1/2 HP 3/4 HP 1 HP 24 25 26 27 28 15-48B10G1 19-41047 19-48033M 75-10170 75-10174 K75-10259 10-10205 11-10130 Sprocket, 41B10x3/4" Roller Chain, #41x47 Pitches Limit Chain, #48x33 Pitches Trolley Front Idler Assembly Tracker Spacer Header Bracket Header Pivot...
... 7 16-5L300 Cogged Belt 8 17-10165 5L Motor Pulley 7" O.D. 9 18-10164 Clutch Spring (1/3 & 1/2 HP) 18-10168 Clutch Spring (3/4 & 1 HP) 10 39-10167 Clutch Disc 11 87-P-075 Push on Fastener 12 12-10331 Flange Bearing 13 15-41B10G1 Sprocket, 41B10x3/4" (3/4 & 1 HP) 15-48B10GXX Sprocket, 41B10x3/4" (1/3 & 1/2 HP) 14 15...HP 1/2 HP 3/4 HP 1 HP 24 25 26 27 28 15-48B10G1 19-41047 19-48033M 75-10170 75-10174 K75-10259 10-10205 11-10130 Sprocket, 41B10x3/4" Roller Chain, #41x47 Pitches Limit Chain, #48x33 Pitches Trolley Front Idler Assembly Tracker Spacer Header Bracket Header Pivot...
GT Logic 4-Repair Parts Manual
Page 3
... Clutch Disc 7 80-207-19 Key, 1/4"x1-1/2" 8 75-10170 Trolley 9 75-10174 Front Idler Assembly 10 K75-10259 Tracker Spacer 11 32-10540 Gear Reducer 12 10-10536 Frame 13 10-10205 Header Bracket 14 11-10130 Header Pivot Pin ITEM 15 1/2 HP PART# K20-1050B-2LP K20-3050B-4P K20-3050M-5 3/4 HP..., Chain, Limit Chain, Key, Carriage Bolt and Nut. model GT1553L4 Door Track* Take Up Bolt Heavy Duty Straight Arm K5 12 9 10 13 8 16 17 5 K6 18 K3 3 4 K1 2 1 11 K2 15 K4 7 6 * Call for Pricing and Availability 3 Drive Shaft Kit Complete with: Drive Shaft, Ball Bearing, Sprocket (40B19,...
... Clutch Disc 7 80-207-19 Key, 1/4"x1-1/2" 8 75-10170 Trolley 9 75-10174 Front Idler Assembly 10 K75-10259 Tracker Spacer 11 32-10540 Gear Reducer 12 10-10536 Frame 13 10-10205 Header Bracket 14 11-10130 Header Pivot Pin ITEM 15 1/2 HP PART# K20-1050B-2LP K20-3050B-4P K20-3050M-5 3/4 HP..., Chain, Limit Chain, Key, Carriage Bolt and Nut. model GT1553L4 Door Track* Take Up Bolt Heavy Duty Straight Arm K5 12 9 10 13 8 16 17 5 K6 18 K3 3 4 K1 2 1 11 K2 15 K4 7 6 * Call for Pricing and Availability 3 Drive Shaft Kit Complete with: Drive Shaft, Ball Bearing, Sprocket (40B19,...
GT Logic 4-Repair Parts Manual
Page 4
...Chain Kits ITEM PART# DESCRIPTION PART# DESCRIPTION 1 22-120 Brake Solenoid, 115 Volts 19-5810 2 17-6014-1 Motor Pulley 19-5812 3 10-10166 Clutch Plate 19-5814 4 11-10014 Clutch Shaft 19-5816 5 12-729 Pillow Flange Bearing 19-5818 6 15-41B10G1 Sprocket, 41B10x3/4" 19-5820 7 16-5L300 Cogged ...Belt 8 17-10165 Clutch Pulley 7" O.D. 5L 9 18-10164 Spring Clutch 10 39-10167 Clutch Disc 11 87-P-075 Push on Fastener. Model APT Service Kits ITEM PART# K1 71-AB120 K2 K72-13057 K3 K72-13059 K4 K75-13074...
...Chain Kits ITEM PART# DESCRIPTION PART# DESCRIPTION 1 22-120 Brake Solenoid, 115 Volts 19-5810 2 17-6014-1 Motor Pulley 19-5812 3 10-10166 Clutch Plate 19-5814 4 11-10014 Clutch Shaft 19-5816 5 12-729 Pillow Flange Bearing 19-5818 6 15-41B10G1 Sprocket, 41B10x3/4" 19-5820 7 16-5L300 Cogged ...Belt 8 17-10165 Clutch Pulley 7" O.D. 5L 9 18-10164 Spring Clutch 10 39-10167 Clutch Disc 11 87-P-075 Push on Fastener. Model APT Service Kits ITEM PART# K1 71-AB120 K2 K72-13057 K3 K72-13059 K4 K75-13074...
GT Logic 4-Repair Parts Manual
Page 5
...For 575 Volt Operators Individual Parts ITEM PART# DESCRIPTION 1 K75-10030 Frame Spacer 2 10-10011M1 Drawbar Frame 3 Motor 4 K28-10747 Double BX Connector Clutch Shaft Kit ITEM PART# DESCRIPTION C1 10-10166 Clutch Plate C2 11-10014 Clutch Shaft C3 12-10029 Bearing 3/4" I .D. C7 18-10164 Clutch Spring...Brake Assembly Kits ITEM PART# DESCRIPTION B1 07-10179 Brake Hub B2 10-10187 Brake Solenoid Cover B3 10-10190 Brake Release Lever B4 10-10191 Brake Disc, Zinc Plated B5 11-10192 Spring Cup B6 11-10193 Brake Stud B7 Compression Spring (Available in complete brake kits only)...
...For 575 Volt Operators Individual Parts ITEM PART# DESCRIPTION 1 K75-10030 Frame Spacer 2 10-10011M1 Drawbar Frame 3 Motor 4 K28-10747 Double BX Connector Clutch Shaft Kit ITEM PART# DESCRIPTION C1 10-10166 Clutch Plate C2 11-10014 Clutch Shaft C3 12-10029 Bearing 3/4" I .D. C7 18-10164 Clutch Spring...Brake Assembly Kits ITEM PART# DESCRIPTION B1 07-10179 Brake Hub B2 10-10187 Brake Solenoid Cover B3 10-10190 Brake Release Lever B4 10-10191 Brake Disc, Zinc Plated B5 11-10192 Spring Cup B6 11-10193 Brake Stud B7 Compression Spring (Available in complete brake kits only)...
GT Logic 4-Repair Parts Manual
Page 6
... Brake Assembly Kits Individual Parts ITEM PART# DESCRIPTION B1 07-10179 Brake Hub B2 10-10187 Brake Solenoid Cover B3 10-10190 Brake Release Lever B4 10-10191 Brake Disc, Zinc Plated B5 11-10192 Spring Cup B6 11-10193 Brake Stud B7 Compression Spring (Available in complete brake kits only) B11 K75... Kit Trolley Slider for Bi-Sliding Door Kit Door Disconnect Kit Drive Shaft Kit ITEM D1 D2 D3 D4 D5 D6 D7 D8 PART# DESCRIPTION 11-10537 Drive Shaft 12-12004 1" Ball Bearing 15-40B19LGF Sprocket, 40B19x1" Bore 15-41B12LXX Sprocket, 41B12x1" Bore 15-48B18LGE Sprocket, 48B18x1" Bore...
... Brake Assembly Kits Individual Parts ITEM PART# DESCRIPTION B1 07-10179 Brake Hub B2 10-10187 Brake Solenoid Cover B3 10-10190 Brake Release Lever B4 10-10191 Brake Disc, Zinc Plated B5 11-10192 Spring Cup B6 11-10193 Brake Stud B7 Compression Spring (Available in complete brake kits only) B11 K75... Kit Trolley Slider for Bi-Sliding Door Kit Door Disconnect Kit Drive Shaft Kit ITEM D1 D2 D3 D4 D5 D6 D7 D8 PART# DESCRIPTION 11-10537 Drive Shaft 12-12004 1" Ball Bearing 15-40B19LGF Sprocket, 40B19x1" Bore 15-41B12LXX Sprocket, 41B12x1" Bore 15-48B18LGE Sprocket, 48B18x1" Bore...
GT Logic 4-Repair Parts Manual
Page 7
...Gear, 5/8" ID 75-13334 Bevel Gear, 3/4" I.D. (3 HP) 9 08-11013 Bevel Gear, 3/4" I.D. 08-13333 Bevel Gear, 3/4" I.D. 24 tooth (3 HP) 10 10-10882 Hand Chain Guide 11 12-10883 Nyliner Bearing 12 12-10029 Bearing, 3/4" I.D. 13 18-11008 Compression Spring 14 75-10884 Chain Wheel Assembly 3 15 5 4 ITEM PART# DESCRIPTION... ID, Nyliner Bearing, Compression Spring, Chain Wheel, Washers, Roll Pins and E-Rings. models GH2023L4, GH2043L4 3 HP K20-3300C-4 Motor - Model GH Service Kits ITEM PART# K1 K75-12584 K75-12585 K75-12586 K2 K75-10177 K3 K72-12789 K75-14661 K4 K75-30737 K5 K75-12829...
...Gear, 5/8" ID 75-13334 Bevel Gear, 3/4" I.D. (3 HP) 9 08-11013 Bevel Gear, 3/4" I.D. 08-13333 Bevel Gear, 3/4" I.D. 24 tooth (3 HP) 10 10-10882 Hand Chain Guide 11 12-10883 Nyliner Bearing 12 12-10029 Bearing, 3/4" I.D. 13 18-11008 Compression Spring 14 75-10884 Chain Wheel Assembly 3 15 5 4 ITEM PART# DESCRIPTION... ID, Nyliner Bearing, Compression Spring, Chain Wheel, Washers, Roll Pins and E-Rings. models GH2023L4, GH2043L4 3 HP K20-3300C-4 Motor - Model GH Service Kits ITEM PART# K1 K75-12584 K75-12585 K75-12586 K2 K75-10177 K3 K72-12789 K75-14661 K4 K75-30737 K5 K75-12829...
GH LOGIC 3 Manual
Page 31
prefix to the model number of your operator. For example: GH5011L3 (Operator) = K-GH5011L3 (Electrical box kit) ITEM 1 2 3 4 5 6 7 8 9 10 11 INDIVIDUAL PARTS PART # DESCRIPTION 13-10024 Limit nut 23-10041 Limit switch K75-32268 Cover 21-14182 Transformer, 115/230V 21-35057 Transformer, 460V 21-...
prefix to the model number of your operator. For example: GH5011L3 (Operator) = K-GH5011L3 (Electrical box kit) ITEM 1 2 3 4 5 6 7 8 9 10 11 INDIVIDUAL PARTS PART # DESCRIPTION 13-10024 Limit nut 23-10041 Limit switch K75-32268 Cover 21-14182 Transformer, 115/230V 21-35057 Transformer, 460V 21-...
GH -Mechanical New style w/ thermal overload change Manual
Page 20
...Single Phase units are not available for individual purchase. 20 ELECTRICAL BOX ITEM 1 2 3 4 5 6 7 8 9 10 11 12 INDIVIDUAL PARTS PART# DESCRIPTION 03-8024-K 10-10020M1 10-10115X 21-5115 Contactor Electrical Box (For Models T, J & H) Electrical Box Cover Transformer, 115V Operators 21-5230 Transformer,...230 Volts Overload 6 Amp Overload 8 Amp Overload 10 Amp Overload 15 Amp Overload 20 Amp Overload 1.6-2.5 Amp Overload 2.6-3.7 Amp Overload 2.5-4.0 Amp Overload 5.5-8.0 Amp Overload 8.0-11.5 Amp Terminal Block, Radio Terminal Block, 10 Position Overload Bracket NOT SHOWN K72-14130 Cube ...
...Single Phase units are not available for individual purchase. 20 ELECTRICAL BOX ITEM 1 2 3 4 5 6 7 8 9 10 11 12 INDIVIDUAL PARTS PART# DESCRIPTION 03-8024-K 10-10020M1 10-10115X 21-5115 Contactor Electrical Box (For Models T, J & H) Electrical Box Cover Transformer, 115V Operators 21-5230 Transformer,...230 Volts Overload 6 Amp Overload 8 Amp Overload 10 Amp Overload 15 Amp Overload 20 Amp Overload 1.6-2.5 Amp Overload 2.6-3.7 Amp Overload 2.5-4.0 Amp Overload 5.5-8.0 Amp Overload 8.0-11.5 Amp Terminal Block, Radio Terminal Block, 10 Position Overload Bracket NOT SHOWN K72-14130 Cube ...
GH Logic 4 Quick Start Guide Manual
Page 2
... WIRING 20 AWG or Greater USE COPPER WIRE ONLY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 LiftMaster Monitored Entrapment Protection (LMEP) is required for every 15 seconds. Follow ALL national and local electrical codes 10 OPEN 7 4 Push and Release to Open CLOSE (without Mid Stop programming) STOP 6 4 Push ...the desired wiring type. MRT MID TIMER The OPEN LED will flash once for every 1 second. NOTE: Must have at least one LiftMaster Monitored Entrapment Protection (LMEP) device installed. Turn selector to the fully open position. 1. Press and release the MID button. Press the ...
... WIRING 20 AWG or Greater USE COPPER WIRE ONLY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 LiftMaster Monitored Entrapment Protection (LMEP) is required for every 15 seconds. Follow ALL national and local electrical codes 10 OPEN 7 4 Push and Release to Open CLOSE (without Mid Stop programming) STOP 6 4 Push ...the desired wiring type. MRT MID TIMER The OPEN LED will flash once for every 1 second. NOTE: Must have at least one LiftMaster Monitored Entrapment Protection (LMEP) device installed. Turn selector to the fully open position. 1. Press and release the MID button. Press the ...