xDirect - Product Brief
Page 1
...extremely flexible, and highly affordable network connectivity solution. xDirect comes with a serial interface. xDirect Highlights: • C omplete Network Connectivity Solution • I ntegrated 10/100 Ethernet Port and Serial Cable • C omplete Device Server Application with Full IP Stack and Web Server • S pace Saving Form Factor •...or tablet from anywhere. With plug-and-play simplicity, small form factor, multiple power options, and a robust device server application, xDirect provides the easiest and shortest path to 85°C • 5 -year Limited Warranty
...extremely flexible, and highly affordable network connectivity solution. xDirect comes with a serial interface. xDirect Highlights: • C omplete Network Connectivity Solution • I ntegrated 10/100 Ethernet Port and Serial Cable • C omplete Device Server Application with Full IP Stack and Web Server • S pace Saving Form Factor •...or tablet from anywhere. With plug-and-play simplicity, small form factor, multiple power options, and a robust device server application, xDirect provides the easiest and shortest path to 85°C • 5 -year Limited Warranty
xDirect - Product Brief
Page 2
...lantronix.com Email: japan_sales@lantronix.com > Part Number XDT2321002-01-S XDT4851002-01-S XDT10P0-01-S > Description xDirect232 Single Port RS232 10/100 Device Server, 100-240 VAC International Power Supply with Regional Adapters, RoHS xDirect485 Single Port RS232/422/485 10/100 Device Server, 100-240 VAC International Power Supply with Regional Adapters, RoHS xDirect... PoE Single Port RS232/422/485 10/100 Device Server, No Power Supply, RoHS > Accessories ...
...lantronix.com Email: japan_sales@lantronix.com > Part Number XDT2321002-01-S XDT4851002-01-S XDT10P0-01-S > Description xDirect232 Single Port RS232 10/100 Device Server, 100-240 VAC International Power Supply with Regional Adapters, RoHS xDirect485 Single Port RS232/422/485 10/100 Device Server, 100-240 VAC International Power Supply with Regional Adapters, RoHS xDirect... PoE Single Port RS232/422/485 10/100 Device Server, No Power Supply, RoHS > Accessories ...
xDirect - Product Brief (A4 Format)
Page 1
... and shortest path to access and configure the unit using a standard web browser on the wire'. MDeDedveiivcciaecle Device SSeSerervvrevererr NETWORK CONNECTIVITY FOR ANY SERIAL DEVICE 'RIGHT ON THE WIRE' xDirect™ is a sleek and compact Serial-toEthernet device server, providing quick and easy Ethernet connectivity to 85°C • 5 -year Limited Warranty With an integrated...
... and shortest path to access and configure the unit using a standard web browser on the wire'. MDeDedveiivcciaecle Device SSeSerervvrevererr NETWORK CONNECTIVITY FOR ANY SERIAL DEVICE 'RIGHT ON THE WIRE' xDirect™ is a sleek and compact Serial-toEthernet device server, providing quick and easy Ethernet connectivity to 85°C • 5 -year Limited Warranty With an integrated...
xDirect - Product Brief (A4 Format)
Page 2
...lantronix.com Email: japan_sales@lantronix.com > Part Number XDT2321002-01-S XDT4851002-01-S XDT10P0-01-S > Description xDirect232 Single Port RS232 10/100 Device Server, 100-240 VAC International Power Supply with Regional Adapters, RoHS xDirect485 Single Port RS232/422/485 10/100 Device Server, 100-240 VAC International Power Supply with Regional Adapters, RoHS xDirect... PoE Single Port RS232/422/485 10/100 Device Server, No Power Supply, RoHS > Accessories ...
...lantronix.com Email: japan_sales@lantronix.com > Part Number XDT2321002-01-S XDT4851002-01-S XDT10P0-01-S > Description xDirect232 Single Port RS232 10/100 Device Server, 100-240 VAC International Power Supply with Regional Adapters, RoHS xDirect485 Single Port RS232/422/485 10/100 Device Server, 100-240 VAC International Power Supply with Regional Adapters, RoHS xDirect... PoE Single Port RS232/422/485 10/100 Device Server, No Power Supply, RoHS > Accessories ...
xDirect - Quick Start Guide
Page 1
... 802.3af PoE compliant power source such as a PoE mid-span or PoE Ethernet switch. Quick Start Guide 1 HARDWARE REvIEW xDirect Device Server Power Supply* 5vDC with International adapters *not included with xDirectPoE version Power Port (mini USB connector) 3.5" (88.9 mm) .../ VDC RX+ (in) DB9F in RS485 (2-Wire) Mode (xDirect485 & PoE Models) 2 HARDWARE InSTALLATIOn 1. Quick Start Guide 1 HARDWARE REvIEW xDirect Device Server Power Supply* 5vDC with International adapters *not included with xDirectPoE version Power / Status LED Serial RX LED Serial Port DB9 Female (DCE) Link ...
... 802.3af PoE compliant power source such as a PoE mid-span or PoE Ethernet switch. Quick Start Guide 1 HARDWARE REvIEW xDirect Device Server Power Supply* 5vDC with International adapters *not included with xDirectPoE version Power Port (mini USB connector) 3.5" (88.9 mm) .../ VDC RX+ (in) DB9F in RS485 (2-Wire) Mode (xDirect485 & PoE Models) 2 HARDWARE InSTALLATIOn 1. Quick Start Guide 1 HARDWARE REvIEW xDirect Device Server Power Supply* 5vDC with International adapters *not included with xDirectPoE version Power / Status LED Serial RX LED Serial Port DB9 Female (DCE) Link ...
xDirect - User Guide
Page 10
... Conversions Appendix F: Compliance Provides Lantronix compliance information. Chapter 4: Using DeviceInstaller Instructions for obtaining the latest firmware and updating the xDirect. Chapter 10: Firmware Upgrades ...Provides instructions for viewing the current configuration using the command line interface to monitor the network and diagnose problems. Appendix A: Troubleshooting Describes common problems and error messages and how to assign an IP address. Appendix D: Alternative Ways to configure, use, and update the xDirect device server...
... Conversions Appendix F: Compliance Provides Lantronix compliance information. Chapter 4: Using DeviceInstaller Instructions for obtaining the latest firmware and updating the xDirect. Chapter 10: Firmware Upgrades ...Provides instructions for viewing the current configuration using the command line interface to monitor the network and diagnose problems. Appendix A: Troubleshooting Describes common problems and error messages and how to assign an IP address. Appendix D: Alternative Ways to configure, use, and update the xDirect device server...
xDirect - User Guide
Page 11
... Start DeviceInstaller Online Help "Live" Tutorials on using the Windows-based utility to configure the xDirect and other Lantronix device servers. Provides information on the Lantronix Web Site (English) Com Port Redirector User Guide Description Provides the steps for the latest documentation and the following additional documentation. Provides instructions for using ...
... Start DeviceInstaller Online Help "Live" Tutorials on using the Windows-based utility to configure the xDirect and other Lantronix device servers. Provides information on the Lantronix Web Site (English) Com Port Redirector User Guide Description Provides the steps for the latest documentation and the following additional documentation. Provides instructions for using ...
xDirect - User Guide
Page 12
... Integrated 10/100 Ethernet Port and Serial Cable Complete Device Server Application with a serial interface. With plug-and-play simplicity, small form factor, multiple power options, and a robust device server application, xDirect provides the easiest and shortest path to network connectivity 'right on ... Warranty Short cable 256-bit AES Encryption Password Protection Applications The xDirect family of Device Servers allows serial devices, such as those listed below, to connect and communicate over Ethernet networks using a standard web browser on the...
... Integrated 10/100 Ethernet Port and Serial Cable Complete Device Server Application with a serial interface. With plug-and-play simplicity, small form factor, multiple power options, and a robust device server application, xDirect provides the easiest and shortest path to network connectivity 'right on ... Warranty Short cable 256-bit AES Encryption Password Protection Applications The xDirect family of Device Servers allows serial devices, such as those listed below, to connect and communicate over Ethernet networks using a standard web browser on the...
xDirect - User Guide
Page 13
... Terminals Universal Power Supply (UPS) Management Units Using a method called serial tunneling, the xDirect encapsulates serial data into packets and transports them over Ethernet. Virtual COM ports, mapped to remote device servers on the Lantronix web site: www.lantronix.com/support. Figure 2-2 Direct TCP/IP or Redirector Configuration Note: For step-by-step instructions...
... Terminals Universal Power Supply (UPS) Management Units Using a method called serial tunneling, the xDirect encapsulates serial data into packets and transports them over Ethernet. Virtual COM ports, mapped to remote device servers on the Lantronix web site: www.lantronix.com/support. Figure 2-2 Direct TCP/IP or Redirector Configuration Note: For step-by-step instructions...
xDirect - User Guide
Page 18
... address), click the Search icon and select the unit from the Lantronix website at the factory. Click Finish. 7. 4: Using DeviceInstaller This chapter covers the steps for getting the xDirect device server online and for more than one network adapter, a message displays.... The unit's IP address is a free utility program provided by Lantronix that discovers, configures, upgrades, and manages Lantronix Device Servers. if desired, you can be configured...
... address), click the Search icon and select the unit from the Lantronix website at the factory. Click Finish. 7. 4: Using DeviceInstaller This chapter covers the steps for getting the xDirect device server online and for more than one network adapter, a message displays.... The unit's IP address is a free utility program provided by Lantronix that discovers, configures, upgrades, and manages Lantronix Device Servers. if desired, you can be configured...
xDirect - User Guide
Page 22
... and when to start or close a connection. Enter your web browser and enter the IP address of the xDirect. Your device may have different configuration options. To view the xDirect's Web Manager in a web browser, click the External Browser button. To open your user name and password.... tool. (For information on DeviceInstaller, see Chapter 6: Configuration Via Telnet or Serial Port (Setup Mode). The list of available Lantronix device servers. 2. xDirect User Guide 22 Note: Alternatively, to open Web Manager, open the Web Manager in the current DeviceInstaller window, click the Go...
... and when to start or close a connection. Enter your web browser and enter the IP address of the xDirect. Your device may have different configuration options. To view the xDirect's Web Manager in a web browser, click the External Browser button. To open your user name and password.... tool. (For information on DeviceInstaller, see Chapter 6: Configuration Via Telnet or Serial Port (Setup Mode). The list of available Lantronix device servers. 2. xDirect User Guide 22 Note: Alternatively, to open Web Manager, open the Web Manager in the current DeviceInstaller window, click the Go...
xDirect - User Guide
Page 26
..., allowing you to create basic passwords up to 16 bytes in length. Figure 5-4 Server Settings To configure the xDirect device server settings: 1. Advanced ARP Cache Timeout (secs) When the unit communicates with another device on the Server Settings page. The following fields: Server Configuration Enhanced Password Telnet/Web Manager Password Retype Password Select whether to enable advanced...
..., allowing you to create basic passwords up to 16 bytes in length. Figure 5-4 Server Settings To configure the xDirect device server settings: 1. Advanced ARP Cache Timeout (secs) When the unit communicates with another device on the Server Settings page. The following fields: Server Configuration Enhanced Password Telnet/Web Manager Password Retype Password Select whether to enable advanced...
xDirect - User Guide
Page 27
... is 80. The default setting is Regular. Select the xDirect's performance mode. Not applicable for a packet sent from entering monitor mode by interpreting the stream of the web server port number. The desired TCP re-transmission timeout value. ...xDirect User Guide 27 On the main menu, click Apply Settings. 5: Configuration Using Web Manager TCP Keepalive (secs) Monitor Mode @ Bootup CPU Performance Mode HTTP Server Port Config Server Port MTU Size TCP Re-transmission timeout (ms) TCP Keepalive time defines how many seconds the unit waits during the device server...
... is 80. The default setting is Regular. Select the xDirect's performance mode. Not applicable for a packet sent from entering monitor mode by interpreting the stream of the web server port number. The desired TCP re-transmission timeout value. ...xDirect User Guide 27 On the main menu, click Apply Settings. 5: Configuration Using Web Manager TCP Keepalive (secs) Monitor Mode @ Bootup CPU Performance Mode HTTP Server Port Config Server Port MTU Size TCP Re-transmission timeout (ms) TCP Keepalive time defines how many seconds the unit waits during the device server...
xDirect - User Guide
Page 29
Port Settings Protocol Flow Control From the drop-down menu, select the protocol type for the selected channel. xDirect User Guide 29 Serial Settings To configure the channel's serial settings: 1. The serial port is RS232. The default setting is ...Settings (under Channel 1) to network and serial communication. Note: This feature is prepared to channel 1. Too much data arriving before a device is not available on single port device servers, since it can only be applied to manage it is the default. 5: Configuration Using Web Manager Channel 1 Configuration The Channel 1...
Port Settings Protocol Flow Control From the drop-down menu, select the protocol type for the selected channel. xDirect User Guide 29 Serial Settings To configure the channel's serial settings: 1. The serial port is RS232. The default setting is ...Settings (under Channel 1) to network and serial communication. Note: This feature is prepared to channel 1. Too much data arriving before a device is not available on single port device servers, since it can only be applied to manage it is the default. 5: Configuration Using Web Manager Channel 1 Configuration The Channel 1...
xDirect - User Guide
Page 33
... for Disconnect with EOT to the network. Enter time in the host list. On the main menu, click Connection. When set to Yes, the device server scrolls through the table until it connects, the unit stops trying to connect to any others. Ctrl+D is None. The default setting is the number...be enabled for no activity on the serial line before the set an inactivity timeout. In the available fields, enter or modify the following information: xDirect User Guide 33 If this parameter to another IP in the format mm:ss, where m is the number of seconds. The default setting is...
... for Disconnect with EOT to the network. Enter time in the host list. On the main menu, click Connection. When set to Yes, the device server scrolls through the table until it connects, the unit stops trying to connect to any others. Ctrl+D is None. The default setting is the number...be enabled for no activity on the serial line before the set an inactivity timeout. In the available fields, enter or modify the following information: xDirect User Guide 33 If this parameter to another IP in the format mm:ss, where m is the number of seconds. The default setting is...
xDirect - User Guide
Page 34
...remote IP or network broadcast address and the remote port. Datagrams of device servers. Datagram Type FD is Yes. 5: Configuration Using Web Manager Figure...address of the remote device. xDirect User Guide 34 Enter the port number of the remote device. Endpoint Configuration Local Port Remote Port Remote Host Use Broadcast Device Address Table Enter the... local port number. The default is set to broadcast. The table is enabled when Datagram Type is not to FD. Enter values between 1 and 255 to broadcast the UDP datagram. Note: Lantronix...
...remote IP or network broadcast address and the remote port. Datagrams of device servers. Datagram Type FD is Yes. 5: Configuration Using Web Manager Figure...address of the remote device. xDirect User Guide 34 Enter the port number of the remote device. Endpoint Configuration Local Port Remote Port Remote Host Use Broadcast Device Address Table Enter the... local port number. The default is set to broadcast. The table is enabled when Datagram Type is not to FD. Enter values between 1 and 255 to broadcast the UDP datagram. Note: Lantronix...
xDirect - User Guide
Page 35
... changes permanent and reboots the xDirect. Figure 5-9 Apply Settings and Apply Defaults xDirect User Guide 35 5: Configuration Using Web Manager Apply Settings 1. For details see Default Settings (Option 7). 2. Note: Clicking OK on each page does not change the configuration on the device. Apply Defaults 1. Click Yes to set the device server back to cancel. To...
... changes permanent and reboots the xDirect. Figure 5-9 Apply Settings and Apply Defaults xDirect User Guide 35 5: Configuration Using Web Manager Apply Settings 1. For details see Default Settings (Option 7). 2. Note: Clicking OK on each page does not change the configuration on the device. Apply Defaults 1. Click Yes to set the device server back to cancel. To...
xDirect - User Guide
Page 36
... 2. Click OK. The following information and login prompts display (see Figure 6-1). Figure 6-1 MAC Address and Login Prompt *** Lantronix xDirect 232 Device Server *** MAC address 00204A9D028B Software version V6.9.0.0RC3 (120828) XDIRECT AES library version 1.8.2.1 User Name :admin xDirect User Guide 36 As an alternative to using a web browser, as described in the configuration chapters show a typical...
... 2. Click OK. The following information and login prompts display (see Figure 6-1). Figure 6-1 MAC Address and Login Prompt *** Lantronix xDirect 232 Device Server *** MAC address 00204A9D028B Software version V6.9.0.0RC3 (120828) XDIRECT AES library version 1.8.2.1 User Name :admin xDirect User Guide 36 As an alternative to using a web browser, as described in the configuration chapters show a typical...
xDirect - User Guide
Page 46
...: ). Command String C121.2.4.5/1 C5 C28.10/12 Table 8-7 Manual Connection Address Example Result if remote IP is 129.1.2.3 and remote port is 0.0.0.0/0, the device server enters Monitor Mode. c) Active Startup No Active Startup With Any Character With active Modem Control in connection state: C = connected, D = disconnected, N ...port number can include a destination port number as well. connection is required between each pair of the remote IP address. xDirect User Guide 46 Default setting. The default start character from the serial port. If you omit the port number from ...
...: ). Command String C121.2.4.5/1 C5 C28.10/12 Table 8-7 Manual Connection Address Example Result if remote IP is 129.1.2.3 and remote port is 0.0.0.0/0, the device server enters Monitor Mode. c) Active Startup No Active Startup With Any Character With active Modem Control in connection state: C = connected, D = disconnected, N ...port number can include a destination port number as well. connection is required between each pair of the remote IP address. xDirect User Guide 46 Default setting. The default start character from the serial port. If you omit the port number from ...
xDirect - User Guide
Page 47
... server if the (www.lantronix.com) is 1234 Enters Monitor Mode. Each entry contains the IP address and the port number. Send '+++' in the hostlist. Show IP addr after 'RING' (Y) ? IP address : (019) 172.(019) .(002) .(000) 002 03. FlushMode (00) ? DisconnTime (00:00) ?: xDirect User ...Change Hostlist ? (N) ? IP address : (172) .(019) .(003) 000.(000) 003 04. If this option, the device server scrolls through the table until it is able to connect to a device listed in the hostlist table. IP : 019.019.002.000 03. The unit does not accept a data connection from a ...
... server if the (www.lantronix.com) is 1234 Enters Monitor Mode. Each entry contains the IP address and the port number. Send '+++' in the hostlist. Show IP addr after 'RING' (Y) ? IP address : (019) 172.(019) .(002) .(000) 002 03. FlushMode (00) ? DisconnTime (00:00) ?: xDirect User ...Change Hostlist ? (N) ? IP address : (172) .(019) .(003) 000.(000) 003 04. If this option, the device server scrolls through the table until it is able to connect to a device listed in the hostlist table. IP : 019.019.002.000 03. The unit does not accept a data connection from a ...