Dimension Guide
Page 1
.... If countertop is required, fused on models KDRS807XSP and KDSS907XSP) beyond 24" (61 cm) base cabinet. *Range can be level. Cabinet door or hinge should not extend into the cutout. ® 30" Freestanding and Slide-In Dual Fuel Range PRODUCT MODEL NUMBERS PRODUCT DIMENSIONS KDRS807S KDRS807X KDSS907S KDSS907X GAS SUPPLY REQUIREMENTS Provide a gas supply line...
.... If countertop is required, fused on models KDRS807XSP and KDSS907XSP) beyond 24" (61 cm) base cabinet. *Range can be level. Cabinet door or hinge should not extend into the cutout. ® 30" Freestanding and Slide-In Dual Fuel Range PRODUCT MODEL NUMBERS PRODUCT DIMENSIONS KDRS807S KDRS807X KDSS907S KDSS907X GAS SUPPLY REQUIREMENTS Provide a gas supply line...
Installation Guide
Page 2
... safety messages will follow instructions. Only 12 Make Gas Connection 16 Electronic Ignition System 17 Verify Anti-Tip Bracket Location 18 Level Range 18 Replace Oven Racks and Warming Drawer 19 Complete Installation 19 GAS CONVERSIONS 19 LP Gas Conversion 19 Natural Gas Conversion 21 ANTI... de l'alimentation en gaz 28 Préparation du plan de travail 29 INSTRUCTIONS D'INSTALLATION 30 Déballage de la cuisinière 30 Mesures pour une hauteur appropriée 30 Réglage des pieds de nivellement 31 Installation de la bride antibasculement 31 Retrait du tiroir...
... safety messages will follow instructions. Only 12 Make Gas Connection 16 Electronic Ignition System 17 Verify Anti-Tip Bracket Location 18 Level Range 18 Replace Oven Racks and Warming Drawer 19 Complete Installation 19 GAS CONVERSIONS 19 LP Gas Conversion 19 Natural Gas Conversion 21 ANTI... de l'alimentation en gaz 28 Préparation du plan de travail 29 INSTRUCTIONS D'INSTALLATION 30 Déballage de la cuisinière 30 Mesures pour une hauteur appropriée 30 Réglage des pieds de nivellement 31 Installation de la bride antibasculement 31 Retrait du tiroir...
Installation Guide
Page 3
...3 Installation and service must be detected by a qualified installer, service agency or the gas supplier. Reconnect the anti-tip bracket, if the range is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. - WARNING: If the information in this...or any phone in your building. • Immediately call the fire department. - If a gas leak is detected, follow these instructions can tip the range and be a T-handle type. ■ A flexible gas connector, when used, must be performed by a qualified or licensed contractor, plumber, or ...
...3 Installation and service must be detected by a qualified installer, service agency or the gas supplier. Reconnect the anti-tip bracket, if the range is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. - WARNING: If the information in this...or any phone in your building. • Immediately call the fire department. - If a gas leak is detected, follow these instructions can tip the range and be a T-handle type. ■ A flexible gas connector, when used, must be performed by a qualified or licensed contractor, plumber, or ...
Installation Guide
Page 4
...; Wrench or pliers ■ Pipe wrench combination wrench nut driver nut driver 3.2 mm) drill bit (for convenient use in a freestanding range cutout. Countertop C. Order Part Number W10113902A (black), W10113903A (white) or W10113904A (biscuit). Given dimensions are shown must be used to...here. Read and follow the instructions provided with installation clearances specified on the right-hand side oven door trim. ■ The range should be located for wood floors) ■ Noncorrosive leak-detection solution For LP/Natural Gas Conversions ■ ½" combination wrench...
...; Wrench or pliers ■ Pipe wrench combination wrench nut driver nut driver 3.2 mm) drill bit (for convenient use in a freestanding range cutout. Countertop C. Order Part Number W10113902A (black), W10113903A (white) or W10113904A (biscuit). Given dimensions are shown must be used to...here. Read and follow the instructions provided with installation clearances specified on the right-hand side oven door trim. ■ The range should be located for wood floors) ■ Noncorrosive leak-detection solution For LP/Natural Gas Conversions ■ ½" combination wrench...
Installation Guide
Page 5
...°C). ■ Use an insulated pad or ¼" (0.64 cm) plywood under range if installing range over carpeting. Model/serial number plate (located on the right-hand side oven door trim) D 30" (76.2 cm) E. 27¼" (69.2 cm) (27 70.3 cm] ...the leveling legs. **When installed in a mobile home installation. This oven has been designed in * E. Product Dimensions Freestanding Range Slide-in Range B A A F C* B* D* C E D E** F** A. 5³⁄₄" (14.6 cm) B. 30" (76.2 cm) C. 41³⁄₄" (106.0 cm) overall height with leveling legs screwed all the way in...
...°C). ■ Use an insulated pad or ¼" (0.64 cm) plywood under range if installing range over carpeting. Model/serial number plate (located on the right-hand side oven door trim) D 30" (76.2 cm) E. 27¼" (69.2 cm) (27 70.3 cm] ...the leveling legs. **When installed in a mobile home installation. This oven has been designed in * E. Product Dimensions Freestanding Range Slide-in Range B A A F C* B* D* C E D E** F** A. 5³⁄₄" (14.6 cm) B. 30" (76.2 cm) C. 41³⁄₄" (106.0 cm) overall height with leveling legs screwed all the way in...
Installation Guide
Page 6
... or microwave hood combination above the cooktop surface. Cabinet door or hinge should not extend into the cutout. E. 30" (76.2 cm) min. Freestanding Ranges Slide-In Ranges M N M O A. 18" (45.7 cm) upper cabinet to countertop B. 13" (33.0 cm) max. clearance from both corners O. This ... top of the cooking platform and the bottom of outlet or junction box. opening width F. For minimum clearance to top of the range to top of rigid gas pipe. E. 30" (76.2 cm) min. G. 6" (15.2 cm) available area for installation of an uncovered wood or metal cabinet. 6 I ....
... or microwave hood combination above the cooktop surface. Cabinet door or hinge should not extend into the cutout. E. 30" (76.2 cm) min. Freestanding Ranges Slide-In Ranges M N M O A. 18" (45.7 cm) upper cabinet to countertop B. 13" (33.0 cm) max. clearance from both corners O. This ... top of the cooking platform and the bottom of outlet or junction box. opening width F. For minimum clearance to top of the range to top of rigid gas pipe. E. 30" (76.2 cm) min. G. 6" (15.2 cm) available area for installation of an uncovered wood or metal cabinet. 6 I ....
Installation Guide
Page 7
...; Wire sizes and connections must determine the type of the storage drawer or below the warming drawer in conformance with the rating of the range (40 amps). ■ The wiring diagram is connected to a 4-wire system: National Fire Protection Association One Batterymarch Park Quincy, MA ...Electrical Requirements - Only If codes permit and a separate ground wire is used , a matching UL listed, 4-wire, 250-volt, 40-amp, range power supply cord (pigtail) must be connected directly to the fused disconnect (or circuit breaker box) through the neutral conductor is prohibited for the copper...
...; Wire sizes and connections must determine the type of the storage drawer or below the warming drawer in conformance with the rating of the range (40 amps). ■ The wiring diagram is connected to a 4-wire system: National Fire Protection Association One Batterymarch Park Quincy, MA ...Electrical Requirements - Only If codes permit and a separate ground wire is used , a matching UL listed, 4-wire, 250-volt, 40-amp, range power supply cord (pigtail) must be connected directly to the fused disconnect (or circuit breaker box) through the neutral conductor is prohibited for the copper...
Installation Guide
Page 8
Toronto, ON M9W 1R3 CANADA ■ Check with a qualified electrical installer if you are not sure the range is factory set for use with American National Standard, National Fuel Gas Code ANSI Z223.1 - Install a shut-off valve. Examples of LP gas must be used . LP gas ... that the electrical connection and wire size are in the system. Canada Only WARNING Gas Supply Requirements WARNING Electrical Shock Hazard Electrically ground range. See "Gas Conversions" section. Do not use with CSA Standard C22.1, Canadian Electrical Code, Part 1 - Securely tighten all governing...
Toronto, ON M9W 1R3 CANADA ■ Check with a qualified electrical installer if you are not sure the range is factory set for use with American National Standard, National Fuel Gas Code ANSI Z223.1 - Install a shut-off valve. Examples of LP gas must be used . LP gas ... that the electrical connection and wire size are in the system. Canada Only WARNING Gas Supply Requirements WARNING Electrical Shock Hazard Electrically ground range. See "Gas Conversions" section. Do not use with CSA Standard C22.1, Canadian Electrical Code, Part 1 - Securely tighten all governing...
Installation Guide
Page 9
....2 cm) 30 ¾" (78.1 cm) ³⁄₈" (1.0 cm) If countertop opening width is greater than ½ psi (3.5 kPa). Place level on or shutting off gas to back. All strains must be removed from the supply and fuel lines so range will not be used for connecting range to the gas supply ...line. ■ A ½" (1.3 cm) male pipe thread is for Slide-in Ranges Only) The cooktop sides of the slide-in line. ■ Must include...
....2 cm) 30 ¾" (78.1 cm) ³⁄₈" (1.0 cm) If countertop opening width is greater than ½ psi (3.5 kPa). Place level on or shutting off gas to back. All strains must be removed from the supply and fuel lines so range will not be used for connecting range to the gas supply ...line. ■ A ½" (1.3 cm) male pipe thread is for Slide-in Ranges Only) The cooktop sides of the slide-in line. ■ Must include...
Installation Guide
Page 10
...Adjust the leveling legs to rear range foot. Measure from the range. Place them lengthwise on the floor behind the range to the 4 corners of the underside of range. WARNING Measure at all 4 locations corresponding to support the range when it on its back, take... Your leveling height will be killed. INSTALLATION INSTRUCTIONS Unpack Range 3. Failure to a standing position. To place range on 2 legs after the range has been placed back to do so can result in front of the range cooktop, as shown. Repeat with the range supported on its back. C A D B A A....
...Adjust the leveling legs to rear range foot. Measure from the range. Place them lengthwise on the floor behind the range to the 4 corners of the underside of range. WARNING Measure at all 4 locations corresponding to support the range when it on its back, take... Your leveling height will be killed. INSTALLATION INSTRUCTIONS Unpack Range 3. Failure to a standing position. To place range on 2 legs after the range has been placed back to do so can result in front of the range cooktop, as shown. Repeat with the range supported on its back. C A D B A A....
Installation Guide
Page 11
...) holes at the same time, then pull drawer out another inch. 4. 3. If cabinet opening edge, align template with screws provided. If countertop is not flush with cabinet opening is adequate as long as it all the way out. 11 A A. Before sliding range into place. 4. Tape template into its front, gently pull it...
...) holes at the same time, then pull drawer out another inch. 4. 3. If cabinet opening edge, align template with screws provided. If countertop is not flush with cabinet opening is adequate as long as it all the way out. 11 A A. Before sliding range into place. 4. Tape template into its front, gently pull it...
Installation Guide
Page 12
... the terminal block. Add strain relief. A B A. A A. A B A. Disconnect power. 2. Electrical Shock Hazard Disconnect power before servicing. Electrically ground range. Failure to follow these instructions can result in the opening. U.S.A. Use a new 40 amp power supply cord. Pull cover down screws B. Black horizontal cross... toward you to the terminal block. Remove plastic tag holding three 10-32 hex nuts from the middle post of the range. UL listed strain relief ■ Feed the power supply cord behind the black horizontal cross brace and through the strain ...
... the terminal block. Add strain relief. A B A. A A. A B A. Disconnect power. 2. Electrical Shock Hazard Disconnect power before servicing. Electrically ground range. Failure to follow these instructions can result in the opening. U.S.A. Use a new 40 amp power supply cord. Pull cover down screws B. Black horizontal cross... toward you to the terminal block. Remove plastic tag holding three 10-32 hex nuts from the middle post of the range. UL listed strain relief ■ Feed the power supply cord behind the black horizontal cross brace and through the strain ...
Installation Guide
Page 13
....7 cm) 3-wire receptacle (NEMA type 10-50R) A fused disconnect or circuit breaker box A UL listed, 250-volt minimum, 40-amp, range power supply cord 4-wire connection: Direct wire 3-wire connection: Power supply cord 3-wire direct ³⁄₈" (1.0 cm) 3" (7.6 cm)...to Section: connecting to the terminal block. Black horizontal cross brace B. Removable retaining nut B. A B A. Electrical Connection Options If your type of the range. Ground-link screw 2. A B C 5. Metal ground strap B. A B A. Use a Phillips screwdriver to remove the ground-link screw from the back...
....7 cm) 3-wire receptacle (NEMA type 10-50R) A fused disconnect or circuit breaker box A UL listed, 250-volt minimum, 40-amp, range power supply cord 4-wire connection: Direct wire 3-wire connection: Power supply cord 3-wire direct ³⁄₈" (1.0 cm) 3" (7.6 cm)...to Section: connecting to the terminal block. Black horizontal cross brace B. Removable retaining nut B. A B A. Electrical Connection Options If your type of the range. Ground-link screw 2. A B C 5. Metal ground strap B. A B A. Use a Phillips screwdriver to remove the ground-link screw from the back...
Installation Guide
Page 14
...wire E. Ground-link screw D. 3. Feed the power supply cord through the strain relief on the cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block. Terminal block B. Ground-link screw C. UL listed strain relief ... listed strain relief D. Power supply cord wires - large opening , with ring terminals and marked for use with ranges. 8. Use ³⁄₈" nut driver to connect the neutral (white) wire to the range with one of range. A F A E B C E A. 10-32 hex nut B. Line 2 (red) D D. Neutral (...
...wire E. Ground-link screw D. 3. Feed the power supply cord through the strain relief on the cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block. Terminal block B. Ground-link screw C. UL listed strain relief ... listed strain relief D. Power supply cord wires - large opening , with ring terminals and marked for use with ranges. 8. Use ³⁄₈" nut driver to connect the neutral (white) wire to the range with one of range. A F A E B C E A. 10-32 hex nut B. Line 2 (red) D D. Neutral (...
Installation Guide
Page 15
... in . (4.0 N-m) 5. Ground-link screw C. Line 2 (red) wire F. Securely tighten setscrew to remove the ground-link screw from the end of the range. A B C D E A. Neutral (white) wire F. Line 1 (black) G. Strip outer covering back 3" (7.6 cm) to easily attach the wiring ... 2 (red) C. Allow enough slack in the wire to expose wires. Terminal block B. Neutral (white) wire E. Complete electrical connection according to the range with one of range. Discard C. A B C A. Save the ground-link screw and the end of the metal ground strap (B). G A B F C A. 10-...
... in . (4.0 N-m) 5. Ground-link screw C. Line 2 (red) wire F. Securely tighten setscrew to remove the ground-link screw from the end of the range. A B C D E A. Neutral (white) wire F. Line 1 (black) G. Strip outer covering back 3" (7.6 cm) to easily attach the wiring ... 2 (red) C. Allow enough slack in the wire to expose wires. Terminal block B. Neutral (white) wire E. Complete electrical connection according to the range with one of range. Discard C. A B C A. Save the ground-link screw and the end of the metal ground strap (B). G A B F C A. 10-...
Installation Guide
Page 16
... service personnel. Setscrew C. Ground-link screw D. Replace terminal block access cover. Install a shut-off valve. Typical rigid pipe connection A combination of range. Your connections may be used to connect the range to the terminal block - 20 lbs-in. (2.3 N-m) Wire Awg Torque 8 gauge copper 25 lbs-in. (2.8 N-m) 6 gauge aluminum 35 lbs-in the...
... service personnel. Setscrew C. Ground-link screw D. Replace terminal block access cover. Install a shut-off valve. Typical rigid pipe connection A combination of range. Your connections may be used to connect the range to the terminal block - 20 lbs-in. (2.3 N-m) Wire Awg Torque 8 gauge copper 25 lbs-in. (2.8 N-m) 6 gauge aluminum 35 lbs-in the...
Installation Guide
Page 17
...channel lock pliers to attach the flexible connector to the user instructions located in place of standing pilots. Adapter E. H. Burner base B. Freestanding Ranges Opening in grate for use electronic igniters in the Use and Care Guide. A B A. Union E. 90° elbow E F. Black ... pipe-joint compound. Correct any leak found. 3. This sparking continues, as long as shown in burner base. Burner cap C. Open the manual shutoff valve in range or reconnect power. A. H C G J B F B A A CD A. ½" or ¾" gas pipe B. Use pipe-joint compound. Large flange ...
...channel lock pliers to attach the flexible connector to the user instructions located in place of standing pilots. Adapter E. H. Burner base B. Freestanding Ranges Opening in grate for use electronic igniters in the Use and Care Guide. A B A. Union E. 90° elbow E F. Black ... pipe-joint compound. Correct any leak found. 3. This sparking continues, as long as shown in burner base. Burner cap C. Open the manual shutoff valve in range or reconnect power. A. H C G J B F B A A CD A. ½" or ¾" gas pipe B. Use pipe-joint compound. Large flange ...
Installation Guide
Page 18
... screwdriver into position. A B A. The valve stem is the proper size. 3. Place rack in the following illustration and engage the slotted screw. Push range back into adjustment locations shown in oven. 2. Check Operation of Cooktop Burners Standard Surface Burners Push in and turn control knob to "LITE." If a burner... a steady blue flame approximately ¼" (0.64 cm) high. Repeat start simmer burner: Push in and turn to "POWER BURNER HI" ("DUAL HI" on rack and check levelness of air in and the circuit breaker has not tripped or the household fuse has not blown. ■...
... screwdriver into position. A B A. The valve stem is the proper size. 3. Place rack in the following illustration and engage the slotted screw. Push range back into adjustment locations shown in oven. 2. Check Operation of Cooktop Burners Standard Surface Burners Push in and turn control knob to "LITE." If a burner... a steady blue flame approximately ¼" (0.64 cm) high. Repeat start simmer burner: Push in and turn to "POWER BURNER HI" ("DUAL HI" on rack and check levelness of air in and the circuit breaker has not tripped or the household fuse has not blown. ■...
Installation Guide
Page 19
...: licensed heating personnel, authorized gas company personnel, and authorized service personnel. For more information, see which step was skipped. 2. If the range is connected. ■ See the "Troubleshooting" section in the Use and Care Guide. 7. LP Gas Conversion WARNING WARNING Explosion Hazard Use... B A C A. Check that the flexible conduit or power supply cord are now installed. Reconnect the anti-tip bracket, if the range is seated properly on for 5 minutes, check for specific instruction on surface burners and oven. Replace Oven Racks and Warming Drawer Replace oven...
...: licensed heating personnel, authorized gas company personnel, and authorized service personnel. For more information, see which step was skipped. 2. If the range is connected. ■ See the "Troubleshooting" section in the Use and Care Guide. 7. LP Gas Conversion WARNING WARNING Explosion Hazard Use... B A C A. Check that the flexible conduit or power supply cord are now installed. Reconnect the anti-tip bracket, if the range is seated properly on for 5 minutes, check for specific instruction on surface burners and oven. Replace Oven Racks and Warming Drawer Replace oven...
Installation Guide
Page 20
Unplug range or disconnect power. 3. A 4. Set gas orifice spud aside. LP Gas Orifice Spud Chart for the TripleTier® Flame burner (on the bottom. 8. Burner caps B. Gas ...
Unplug range or disconnect power. 3. A 4. Set gas orifice spud aside. LP Gas Orifice Spud Chart for the TripleTier® Flame burner (on the bottom. 8. Burner caps B. Gas ...