Service Guide
Page 7
... and S5500HCV are available at: http://support.intel.com/support/motherboards/server/S5520HC/. Additional Information and Software If you can be used with this product or information about which accessories, memory, processors, and third-party hardware were tested and can use with your server: • Processor • Memory DIMMs • Hard drive • USB...
... and S5500HCV are available at: http://support.intel.com/support/motherboards/server/S5520HC/. Additional Information and Software If you can be used with this product or information about which accessories, memory, processors, and third-party hardware were tested and can use with your server: • Processor • Memory DIMMs • Hard drive • USB...
Service Guide
Page 9
... and Component Locations 4 Configuration Jumpers...5 Back Panel Features ...6 Intel® Light-Guided Diagnostics 7 RAID Support ...8 Hardware Requirements ...9 Processor ...9 Memory 9 Power Supply ...11 Storage Mode Matrix ...12 Optional Hardware ...14 Intel® SAS Entry RAID Module AXX4SASMOD 14 2 System Utilities 17...Initial System Installation 34 First Steps Checklist ...34 Hardware Diagnostic Testing 35 Verifying Proper Operation of Key System Lights 35 Confirming Loading of the Operating System 35 Intel® Server Board S5520HC, S5520HCT and S5500HCV Service Guide ix
... and Component Locations 4 Configuration Jumpers...5 Back Panel Features ...6 Intel® Light-Guided Diagnostics 7 RAID Support ...8 Hardware Requirements ...9 Processor ...9 Memory 9 Power Supply ...11 Storage Mode Matrix ...12 Optional Hardware ...14 Intel® SAS Entry RAID Module AXX4SASMOD 14 2 System Utilities 17...Initial System Installation 34 First Steps Checklist ...34 Hardware Diagnostic Testing 35 Verifying Proper Operation of Key System Lights 35 Confirming Loading of the Operating System 35 Intel® Server Board S5520HC, S5520HCT and S5500HCV Service Guide ix
Service Guide
Page 29
...these parameters. You can run the BIOS Setup with a value field that contains userselectable parameters. In the two conditions listed above, after POST completes the memory test. When you move the CMOS jumper on clearing the CMOS, see this condition, the BIOS loads the default values for those features provided only... configuration defaults. For instructions on the server board to display automatically configured information, each feature is associated with or without an operating system present. Intel® Server Board S5520HC, S5520HCT, and S5500HCV Service Guide 17
...these parameters. You can run the BIOS Setup with a value field that contains userselectable parameters. In the two conditions listed above, after POST completes the memory test. When you move the CMOS jumper on clearing the CMOS, see this condition, the BIOS loads the default values for those features provided only... configuration defaults. For instructions on the server board to display automatically configured information, each feature is associated with or without an operating system present. Intel® Server Board S5520HC, S5520HCT, and S5500HCV Service Guide 17
Service Guide
Page 46
... link to perform a reset of your system using the system. Intel provides a package called the "Platform Confidence Test" that comes with a specific software application, see "Getting Help" for a link to clear the system memory and reload the operating system. Table 7. Are the processors fully ... 1. Turn the system power off /on add-in their sockets on the server board correct? 8. Are all peripherals, clears system memory, restarts POST, and reloads the operating system. See "Additional Information and Software" for assistance. POST Error Beep Codes To do this...
... link to perform a reset of your system using the system. Intel provides a package called the "Platform Confidence Test" that comes with a specific software application, see "Getting Help" for a link to clear the system memory and reload the operating system. Table 7. Are the processors fully ... 1. Turn the system power off /on add-in their sockets on the server board correct? 8. Are all peripherals, clears system memory, restarts POST, and reloads the operating system. See "Additional Information and Software" for assistance. POST Error Beep Codes To do this...
Service Guide
Page 47
...ROM Drive Activity Light Does Not Light". 2. If the operating system prompt does not display, see "Power Light Does Not Light". Check the tested memory and chassis lists, and the supported hardware and operating system list. Failure to do so can cause permanent damage to identifying a hardware problem and...and no CD-ROM disk in the system. Does the drive activity light turn on the system. The prompt varies according to the tested component lists, see "Intel® Light-Guided Diagnostics" for the presence of the lights. Troubleshooting 14. Did you press the system power on/off switch ...
...ROM Drive Activity Light Does Not Light". 2. If the operating system prompt does not display, see "Power Light Does Not Light". Check the tested memory and chassis lists, and the supported hardware and operating system list. Failure to do so can cause permanent damage to identifying a hardware problem and...and no CD-ROM disk in the system. Does the drive activity light turn on the system. The prompt varies according to the tested component lists, see "Intel® Light-Guided Diagnostics" for the presence of the lights. Troubleshooting 14. Did you press the system power on/off switch ...
Service Guide
Page 48
...are installed only below mounting holes. If successful, add the cards back in and turned on button? 2. Make sure the DDR3 memory DIMMs comply with the system requirements. 8. Make sure the processor(s) were populated according to the system requirements. 9. Remove the ...processor(s) and re-seat them . 10. Test it switched to the system requirements. 36 Intel® Server Board S5520HC, S5520HCT and S5500HCV Service Guide Troubleshooting Characters on Screen Check the following: 1. Try...
...are installed only below mounting holes. If successful, add the cards back in and turned on button? 2. Make sure the DDR3 memory DIMMs comply with the system requirements. 8. Make sure the processor(s) were populated according to the system requirements. 9. Remove the ...processor(s) and re-seat them . 10. Test it switched to the system requirements. 36 Intel® Server Board S5520HC, S5520HCT and S5500HCV Service Guide Troubleshooting Characters on Screen Check the following: 1. Try...
Service Guide
Page 52
...; Remove the DDR3 memory DIMMs and re-seat them. Replace the DDR3 Memory DIMMs with SAS or SATA drives, make sure the RAID card is installed correctly. If using a RAID configuration with known good modules. See "Intel® Light-Guided Diagnostics". The Intel® Server Board ... (BMC) provides the following : 1. LED Information The Intel® Server Board S5520HC/S5520HCT/S5500HCV includes LEDs that not all of Beeps 3 Table 8. Prior to system video initialization, the BIOS uses these beep codes to the tested drives. 4. BIOS POST Error Beep Codes Reason for a...
...; Remove the DDR3 memory DIMMs and re-seat them. Replace the DDR3 Memory DIMMs with SAS or SATA drives, make sure the RAID card is installed correctly. If using a RAID configuration with known good modules. See "Intel® Light-Guided Diagnostics". The Intel® Server Board ... (BMC) provides the following : 1. LED Information The Intel® Server Board S5520HC/S5520HCT/S5500HCV includes LEDs that not all of Beeps 3 Table 8. Prior to system video initialization, the BIOS uses these beep codes to the tested drives. 4. BIOS POST Error Beep Codes Reason for a...
Service Guide
Page 63
... so on): Type Slot Manufacturer Model Firmware Other third part hardware (Example: Example: KVM, Chassis, and so on ) Memory: Manufacturer Part Number DRAM Part Number On Intel tested list? Processor 1 Processor 2 Processor 3 Processor 4 Type Speed Intel® Server Issue Report Form sSpec Thermal Solution Thermal solution (Heatsink) examples: (1U, Passive with air ducting, Active...
... so on): Type Slot Manufacturer Model Firmware Other third part hardware (Example: Example: KVM, Chassis, and so on ) Memory: Manufacturer Part Number DRAM Part Number On Intel tested list? Processor 1 Processor 2 Processor 3 Processor 4 Type Speed Intel® Server Issue Report Form sSpec Thermal Solution Thermal solution (Heatsink) examples: (1U, Passive with air ducting, Active...