Installation Instructions
Page 1
... with battery backup • Conventional (1 Heat, 1 Cool stages) • Heat Pump (up to 2 Heat,1 Cool stages) • 2 Pipe Fan Coil • 2 Pipe Fan Coil with Auxiliary Heat • 4 Pipe Fan Coil • PTAC (up to 2 Heat, 1 Cool) Manual or automatic changeover selectable Heat-Off-Cool-Auto Auto, On Low, Medium, High Remote Setback Input for occupancy sensor or DDC setback VersaSpeed™ Fan Ramping Algorithm for your application. 3. INSTALLATION When Installing this control is complete, check out product operation...
... with battery backup • Conventional (1 Heat, 1 Cool stages) • Heat Pump (up to 2 Heat,1 Cool stages) • 2 Pipe Fan Coil • 2 Pipe Fan Coil with Auxiliary Heat • 4 Pipe Fan Coil • PTAC (up to 2 Heat, 1 Cool) Manual or automatic changeover selectable Heat-Off-Cool-Auto Auto, On Low, Medium, High Remote Setback Input for occupancy sensor or DDC setback VersaSpeed™ Fan Ramping Algorithm for your application. 3. INSTALLATION When Installing this control is complete, check out product operation...
Installation Instructions
Page 2
... wallplate over the wall anchors. 6. Disconnect power supply before installation. Use a pencil to your system type (conventional or heat pump). (See Fig. 4). Use 18 gauge thermostat wire. Terminal identifications for the application. 3. See Fig. 5. 5. TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT CAUTION Electrical Shock or Equipment Damage Hazard. Remove the wallplate from sun or appliances. - Hot or cold air from affecting the thermostat. 2 WALLPLATE WIRE HOLE WIRING IMPORTANT - Shielded cable...
... wallplate over the wall anchors. 6. Disconnect power supply before installation. Use a pencil to your system type (conventional or heat pump). (See Fig. 4). Use 18 gauge thermostat wire. Terminal identifications for the application. 3. See Fig. 5. 5. TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT CAUTION Electrical Shock or Equipment Damage Hazard. Remove the wallplate from sun or appliances. - Hot or cold air from affecting the thermostat. 2 WALLPLATE WIRE HOLE WIRING IMPORTANT - Shielded cable...
Installation Instructions
Page 3
... cool (O-factory setting) or heat (B). WIRE TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT WALLPLATE WALL OPENING SHADED AREA M22266 Fig. 5. Y Compressor output. Auxiliary heat relay to shaded area of heating system transformer. G2 Fan relay. NOTES: 1. 2. 3. 4. When used in a single-transformer system, leave metal jumper wire in the Installer Setup, configure changeover valve for heating and cooling, the common must have a cable separate from the thermostat control cable. Table 3. Terminal Designation Descriptions. C (see Note 1) Power for cooling-connect...
... cool (O-factory setting) or heat (B). WIRE TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT WALLPLATE WALL OPENING SHADED AREA M22266 Fig. 5. Y Compressor output. Auxiliary heat relay to shaded area of heating system transformer. G2 Fan relay. NOTES: 1. 2. 3. 4. When used in a single-transformer system, leave metal jumper wire in the Installer Setup, configure changeover valve for heating and cooling, the common must have a cable separate from the thermostat control cable. Table 3. Terminal Designation Descriptions. C (see Note 1) Power for cooling-connect...
Installation Instructions
Page 4
... S2 R2 HEAT RELAY INDOOR TEMPERATURE SENSOR/REMOTE SETBACK 1 POWER SUPPLY. TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT Conventional System Wiring L1 1 (HOT) C 3 W1 G G2 Y G3 24 VAC O/B S1 L2 RC S2 R2 COMPRESSOR CONTACTOR FAN RELAY INDOOR TEMPERATURE SENSOR/REMOTE SETBACK HEAT RELAY 1 POWER SUPPLY. M27419 Fig. 9. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2 REMOVE FACTORY INSTALLED JUMPER. 3 WHEN USING BATTERIES, THE 24V COMMON CONNECTION IS OPTIONAL. Typical hookup of cool-only...
... S2 R2 HEAT RELAY INDOOR TEMPERATURE SENSOR/REMOTE SETBACK 1 POWER SUPPLY. TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT Conventional System Wiring L1 1 (HOT) C 3 W1 G G2 Y G3 24 VAC O/B S1 L2 RC S2 R2 COMPRESSOR CONTACTOR FAN RELAY INDOOR TEMPERATURE SENSOR/REMOTE SETBACK HEAT RELAY 1 POWER SUPPLY. M27419 Fig. 9. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2 REMOVE FACTORY INSTALLED JUMPER. 3 WHEN USING BATTERIES, THE 24V COMMON CONNECTION IS OPTIONAL. Typical hookup of cool-only...
Installation Instructions
Page 5
... DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2 FACTORY INSTALLED JUMPER. 3 WHEN USING BATTERIES, THE 24V COMMON CONNECTION IS OPTIONAL. 4 "O/B" TERMINAL SET TO CONTROL AS EITHER "O" OR "B" IN THE INSTALLER SETUP. 5 OPTIONAL INDOOR REMOTE SENSOR OR REMOTE SETBACK. TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT Heat Pump System Wiring Fan Coil System Wiring L1 (HOT) 3 24 VAC C W1 L2 G G2 1 Y G3 4 O/B S1 RC S2 R2 CHANGEOVER VALVE COMPRESSOR CONTACTOR FAN RELAY INDOOR TEMPERATURE SENSOR/REMOTE SETBACK 5 1 POWER...
... DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2 FACTORY INSTALLED JUMPER. 3 WHEN USING BATTERIES, THE 24V COMMON CONNECTION IS OPTIONAL. 4 "O/B" TERMINAL SET TO CONTROL AS EITHER "O" OR "B" IN THE INSTALLER SETUP. 5 OPTIONAL INDOOR REMOTE SENSOR OR REMOTE SETBACK. TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT Heat Pump System Wiring Fan Coil System Wiring L1 (HOT) 3 24 VAC C W1 L2 G G2 1 Y G3 4 O/B S1 RC S2 R2 CHANGEOVER VALVE COMPRESSOR CONTACTOR FAN RELAY INDOOR TEMPERATURE SENSOR/REMOTE SETBACK 5 1 POWER...
Installation Instructions
Page 6
.... 2 FACTORY INSTALLED JUMPER. 3 WHEN USING BATTERIES, THE 24V COMMON CONNECTION IS OPTIONAL. 4 "O/B" TERMINAL SET TO CONTROL AS EITHER "O" OR "B" IN THE INSTALLER SETUP. 5 OPTIONAL INDOOR REMOTE SENSOR OR REMOTE SETBACK. M27482 Fig. 19. TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT PTAC System Wiring Sensor Wiring for Temperature Averaging L1 (HOT) 3 24 VAC C W1 L2 G G2 1 Y G3 4 O/B S1 RC S2 R2 CHANGEOVER VALVE COMPRESSOR CONTACTOR LOW FAN RELAY INDOOR TEMPERATURE SENSOR/REMOTE SETBACK 5 HIGH FAN RELAY 1 POWER...
.... 2 FACTORY INSTALLED JUMPER. 3 WHEN USING BATTERIES, THE 24V COMMON CONNECTION IS OPTIONAL. 4 "O/B" TERMINAL SET TO CONTROL AS EITHER "O" OR "B" IN THE INSTALLER SETUP. 5 OPTIONAL INDOOR REMOTE SENSOR OR REMOTE SETBACK. M27482 Fig. 19. TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT PTAC System Wiring Sensor Wiring for Temperature Averaging L1 (HOT) 3 24 VAC C W1 L2 G G2 1 Y G3 4 O/B S1 RC S2 R2 CHANGEOVER VALVE COMPRESSOR CONTACTOR LOW FAN RELAY INDOOR TEMPERATURE SENSOR/REMOTE SETBACK 5 HIGH FAN RELAY 1 POWER...
Installation Instructions
Page 7
... labeled Remove. Wiring four C7189U (10K ohm) Sensors to Wallplate 1. Mount Thermostat to provide a temperature averaging network. Align the terminal screw blocks with battery backup (AA alkaline). See Fig. 22. BATTERIES (2) BATTERY HOLDER M23024 Fig. 24. BACK OF THERMOSTAT Fig. 22. C7189 C7189 REMOVE TAB REMOVE DURING INSTALLATION 1 WIRES MUST HAVE A CABLE SEPARATE FROM THE THERMOSTAT CABLE. Leave the metal jumper wire in order to set the real-time clock...
... labeled Remove. Wiring four C7189U (10K ohm) Sensors to Wallplate 1. Mount Thermostat to provide a temperature averaging network. Align the terminal screw blocks with battery backup (AA alkaline). See Fig. 22. BATTERIES (2) BATTERY HOLDER M23024 Fig. 24. BACK OF THERMOSTAT Fig. 22. C7189 C7189 REMOVE TAB REMOVE DURING INSTALLATION 1 WIRES MUST HAVE A CABLE SEPARATE FROM THE THERMOSTAT CABLE. Leave the metal jumper wire in order to set the real-time clock...
Installation Instructions
Page 8
SETTING DATE/TIME AFTER THERMOSTAT IS ALREADY FUNCTIONING Use the installer setup to match the HVAC system. ADVANCED SETTINGS The thermostat has advanced settings to set year, month and day. These settings can be adjusted to match specific needs. M23023A 62-0273-05 8 The thermostat proceeds through a sequence of setup screens. YEAR MONTH DAY UP AND DOWN KEYS CHANGES MONTH, DAY, YEAR AND TIME Tue DeSelect Day FanUseEdit View System & Fan Schedule Clock & More PM Done GO BACK KEY GOES BACK...
SETTING DATE/TIME AFTER THERMOSTAT IS ALREADY FUNCTIONING Use the installer setup to match the HVAC system. ADVANCED SETTINGS The thermostat has advanced settings to set year, month and day. These settings can be adjusted to match specific needs. M23023A 62-0273-05 8 The thermostat proceeds through a sequence of setup screens. YEAR MONTH DAY UP AND DOWN KEYS CHANGES MONTH, DAY, YEAR AND TIME Tue DeSelect Day FanUseEdit View System & Fan Schedule Clock & More PM Done GO BACK KEY GOES BACK...
Installation Instructions
Page 9
... option is overridden and normal backlight operation occurs. 9 62-0273-05 When the display changes, release the System and Done keys. IMPORTANT Use Installer System Test to electric (does not show up if conventional system with reheat (ISU 0170). 0280 Continuous Backlight 0 0-No 1-Yes Always shown; Press and release the System key. 2. TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT INSTALLER SETUP NUMBERS, SETTINGS, AND TESTS (TABLE 4) Configure Installer Setup 1.
... option is overridden and normal backlight operation occurs. 9 62-0273-05 When the display changes, release the System and Done keys. IMPORTANT Use Installer System Test to electric (does not show up if conventional system with reheat (ISU 0170). 0280 Continuous Backlight 0 0-No 1-Yes Always shown; Press and release the System key. 2. TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT INSTALLER SETUP NUMBERS, SETTINGS, AND TESTS (TABLE 4) Configure Installer Setup 1.
Installation Instructions
Page 10
... Only shown if Remote Setback (ISU 0340) is enabled. 0342 Override Option 0 (only available in non-programmable mode) 0-No Override 1-Override This option is only available for fan coil or PTAC applications. 0348 Fan Mode 0 0-User can choose To select a particular fan mode: Auto is unavailable. Installer Setup Menu. (Continued) Installer Setup Number Installer Setup Name Default Setting All Settings Notes 0300 Changeover 1 0-Manual 1-Auto Only shown if system has both heat and cool stages (ISU 0170).
... Only shown if Remote Setback (ISU 0340) is enabled. 0342 Override Option 0 (only available in non-programmable mode) 0-No Override 1-Override This option is only available for fan coil or PTAC applications. 0348 Fan Mode 0 0-User can choose To select a particular fan mode: Auto is unavailable. Installer Setup Menu. (Continued) Installer Setup Number Installer Setup Name Default Setting All Settings Notes 0300 Changeover 1 0-Manual 1-Auto Only shown if system has both heat and cool stages (ISU 0170).
Installation Instructions
Page 11
... heat/cool is calculated after the user selects the constant fan speed. Partial 3: Locks out schedule, system, fan, and up/ down arrow changes. The setting affects control operation in CNV, Heat Pump, PTAC (ISU 0170). Only shown if system has cool stages (ISU 0170). 0 disables the ramped recovery (step setpoint change ). Full: Entire interface locked/non-functional. Only integral gains are affected by this setting. Installer Setup Menu. (Continued) Installer Setup Number Installer Setup Name 0349 Auto Fan Reset Default Setting All Settings 0 0-Inactive 1-Reset...
... heat/cool is calculated after the user selects the constant fan speed. Partial 3: Locks out schedule, system, fan, and up/ down arrow changes. The setting affects control operation in CNV, Heat Pump, PTAC (ISU 0170). Only shown if system has cool stages (ISU 0170). 0 disables the ramped recovery (step setpoint change ). Full: Entire interface locked/non-functional. Only integral gains are affected by this setting. Installer Setup Menu. (Continued) Installer Setup Number Installer Setup Name 0349 Auto Fan Reset Default Setting All Settings 0 0-Inactive 1-Reset...
Installation Instructions
Page 12
... settings and time. 0 0-Off 1-Cool Stage 1 0 0-Off 1-Fan Stage 1 2-Fan Stage 2 3-Fan Stage 3 0 0-Off 1-Heat Stage 1 2-Heat Stage 2 0 0-EM Heat Off 1-EM Heat On Only shown if system has cool stages. Resets all ISU parameters to default values and resets the schedule to exit the Installer System Test. 62-0273-05 12 Systems with more heating than cooling stages). TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT Installer Setup Number Installer Setup Name 0700 Temperature Display Offset 0710 0720 Restore Factory Defaults Screen Display INSTALLER...
... settings and time. 0 0-Off 1-Cool Stage 1 0 0-Off 1-Fan Stage 1 2-Fan Stage 2 3-Fan Stage 3 0 0-Off 1-Heat Stage 1 2-Heat Stage 2 0 0-EM Heat Off 1-EM Heat On Only shown if system has cool stages. Resets all ISU parameters to default values and resets the schedule to exit the Installer System Test. 62-0273-05 12 Systems with more heating than cooling stages). TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT Installer Setup Number Installer Setup Name 0700 Temperature Display Offset 0710 0720 Restore Factory Defaults Screen Display INSTALLER...
Installation Instructions
Page 13
... 4 hour timer fan reset function. The thermostat will be configured for installer setup selection. When ISU 340 has a 2 pipe changeover sensor enabled, the thermostat screen system mode will give the Fan On/Auto option. When the 2 pipe changeover sensor is available (ISU 340). Special Programmable Mode Functions Installer Setup 160 allows the thermostat to heating mode which will only have a priority when choosing a system mode (heat or cool). Occupancy sensors, manual time clock inputs, and DDC night setback can adjust to...
... 4 hour timer fan reset function. The thermostat will be configured for installer setup selection. When ISU 340 has a 2 pipe changeover sensor enabled, the thermostat screen system mode will give the Fan On/Auto option. When the 2 pipe changeover sensor is available (ISU 340). Special Programmable Mode Functions Installer Setup 160 allows the thermostat to heating mode which will only have a priority when choosing a system mode (heat or cool). Occupancy sensors, manual time clock inputs, and DDC night setback can adjust to...
Installation Instructions
Page 14
... program. Check Installer Setup Number 0170 and make sure correct system type is chosen. Verify operation of five minutes before taking a reading. Check for the system to 0 minutes in the display and the compressor and fan turn on . If 24 Vac is present, the thermostat is fully locked. Cool-Thermostat controls the cooling system. Auto-Thermostat automatically changes between the heat terminal (W) and transformer common. If the thermostat is system powered (common wire...
... program. Check Installer Setup Number 0170 and make sure correct system type is chosen. Verify operation of five minutes before taking a reading. Check for the system to 0 minutes in the display and the compressor and fan turn on . If 24 Vac is present, the thermostat is fully locked. Cool-Thermostat controls the cooling system. Auto-Thermostat automatically changes between the heat terminal (W) and transformer common. If the thermostat is system powered (common wire...
Installation Instructions
Page 15
... (Installer Setup air in the display). Cooling equipment failure. If voltage is not set the or temperature setting is not present, check the cooling equipment to Thermostat Controls a call for 24 Vac between power and common. Loose or broken wire connection between the cool terminal (Y) and transformer common. Fan does not turn on in Fan Control in Heating is solid in the heat mode and Number 0190) is not configured to Heat and set temperature setting above room temperature. with Fan. below Pump...
... (Installer Setup air in the display). Cooling equipment failure. If voltage is not set the or temperature setting is not present, check the cooling equipment to Thermostat Controls a call for 24 Vac between power and common. Loose or broken wire connection between the cool terminal (Y) and transformer common. Fan does not turn on in Fan Control in Heating is solid in the heat mode and Number 0190) is not configured to Heat and set temperature setting above room temperature. with Fan. below Pump...
Installation Instructions
Page 16
.... (152 mm) wide x 1-3/8 in U.S.A. TR21-A Wall-Mount Remote Indoor Sensor: 10K ohm NTC. TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT SPECIFICATIONS Electrical Ratings: Terminal W (Heating) Y (Cooling) G (Fan) Voltage (50/60 Hz) 20 - 30 Vac 20 - 30 Vac 20 - 30 Vac Running Current 0.02 - 1.0A 0.02 - 1.0A 0.02 - 0.60A Temperature Setting Range: Heating: 40°F to 90°F (4.5°C to 49°C). Cooling: 50°F to 99°F (10...
.... (152 mm) wide x 1-3/8 in U.S.A. TR21-A Wall-Mount Remote Indoor Sensor: 10K ohm NTC. TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT SPECIFICATIONS Electrical Ratings: Terminal W (Heating) Y (Cooling) G (Fan) Voltage (50/60 Hz) 20 - 30 Vac 20 - 30 Vac 20 - 30 Vac Running Current 0.02 - 1.0A 0.02 - 1.0A 0.02 - 0.60A Temperature Setting Range: Heating: 40°F to 90°F (4.5°C to 49°C). Cooling: 50°F to 99°F (10...