Installation Instructions
Page 2
... 14 screws. 4. Perform a Walk Test. 7. 3 Install / Replace the Battery IMPORTANT: Use only lithium batteries. Use four (4) lithium 1.5VDC AA cells. (Energizer L91 or equivalent.) Change all four batteries at the same time. If necessary, loosen the Captive Lock Screw and lift Cover... off. Observe the proper polarity and replace the batteries. Fasten with the M3 x 10 Captive Lock Screw. 7. Perform a ...
... 14 screws. 4. Perform a Walk Test. 7. 3 Install / Replace the Battery IMPORTANT: Use only lithium batteries. Use four (4) lithium 1.5VDC AA cells. (Energizer L91 or equivalent.) Change all four batteries at the same time. If necessary, loosen the Captive Lock Screw and lift Cover... off. Observe the proper polarity and replace the batteries. Fasten with the M3 x 10 Captive Lock Screw. 7. Perform a ...
Installation Instructions
Page 5
...results. 7 Program the Control Panel Prior to use the Walk Test setting or temporally set the Battery Saving Timer to 5 sec. Refer to ON. Then walk test to remain static, and check for changes due to environmental thermal conditions. If the detection length is a big temperature difference ... the detection area (see Perform Settings & Adjustments). 5. When the programming is complete ensure the Walk Test switch is set to OFF, and the Battery Saving Timer is generated instantly. 1. 6 Perform a Walk Test NOTE: With the Walk Test switch set to ON the LED will light when the...
...results. 7 Program the Control Panel Prior to use the Walk Test setting or temporally set the Battery Saving Timer to 5 sec. Refer to ON. Then walk test to remain static, and check for changes due to environmental thermal conditions. If the detection length is a big temperature difference ... the detection area (see Perform Settings & Adjustments). 5. When the programming is complete ensure the Walk Test switch is set to OFF, and the Battery Saving Timer is generated instantly. 1. 6 Perform a Walk Test NOTE: With the Walk Test switch set to ON the LED will light when the...
Installation Instructions
Page 6
...detection area. Alarms when no one is faulty or loose. Batteries are incorrectly installed or dead. Sensor is not perpendicular to...moving trees, or bushes or a strong light source. Low battery fault indicated on system keypad display. Check for correct battery installation, or replace dead batteries. Transmitter or PIR sensor is too long. Sensor is ...No detection, when walking through the detection area. Batteries are very low or dead. Lower detection area is faulty. Mask the area pointing to a shorter range. Replace batteries. Water in the housing that would allow water ...
...detection area. Alarms when no one is faulty or loose. Batteries are incorrectly installed or dead. Sensor is not perpendicular to...moving trees, or bushes or a strong light source. Low battery fault indicated on system keypad display. Check for correct battery installation, or replace dead batteries. Transmitter or PIR sensor is too long. Sensor is ...No detection, when walking through the detection area. Batteries are very low or dead. Lower detection area is faulty. Mask the area pointing to a shorter range. Replace batteries. Water in the housing that would allow water ...