Installation Instructions
Page 2
...and lift Cover off. Then, remove 4 screws that secure the Detector to the Back Box. 3. Observe the proper polarity and replace the batteries. Fasten with the M3 x 10 Captive Lock Screw. 7. Perform Settings & Adjustments. 5. Secure the Cover with four self ...2. Program the control panel. Attach the Brackets to the Back Box and fasten with new batteries. Observe polarity. 1. POLE MOUNTING 1. Perform a Walk Test. 7. 3 Install / Replace the Battery IMPORTANT: Use only lithium batteries. Use four (4) lithium 1.5VDC AA cells. (Energizer L91 or equivalent.) ...
...and lift Cover off. Then, remove 4 screws that secure the Detector to the Back Box. 3. Observe the proper polarity and replace the batteries. Fasten with the M3 x 10 Captive Lock Screw. 7. Perform Settings & Adjustments. 5. Secure the Cover with four self ...2. Program the control panel. Attach the Brackets to the Back Box and fasten with new batteries. Observe polarity. 1. POLE MOUNTING 1. Perform a Walk Test. 7. 3 Install / Replace the Battery IMPORTANT: Use only lithium batteries. Use four (4) lithium 1.5VDC AA cells. (Energizer L91 or equivalent.) ...
Installation Instructions
Page 4
...alarm output operates only once in place with the Lens Holder. Battery life will be made with as little as two steps. Pulse Count Default Setting - 4 - Then apply the adhesive Masking Strip(s), as four steps. 3. Replace the Lens by aligning the 4 cutouts on the Lens to be... applications where you are engaged. Cover 6. Sensitivity Select Switch (Low, Med, High) DIP Switches Default Setting Low Sensitivity - Use for the desired Battery Saving Timer period. Pulse Count of 4 = detection can be shortened when using this setting. 2. ON 123 OFF 120s 4 ON 1. Identify the...
...alarm output operates only once in place with the Lens Holder. Battery life will be made with as little as two steps. Pulse Count Default Setting - 4 - Then apply the adhesive Masking Strip(s), as four steps. 3. Replace the Lens by aligning the 4 cutouts on the Lens to be... applications where you are engaged. Cover 6. Sensitivity Select Switch (Low, Med, High) DIP Switches Default Setting Low Sensitivity - Use for the desired Battery Saving Timer period. Pulse Count of 4 = detection can be shortened when using this setting. 2. ON 123 OFF 120s 4 ON 1. Identify the...
Installation Instructions
Page 5
... perform a walk test to verify satisfactory results. 7 Program the Control Panel Prior to use the Walk Test setting or temporally set the Battery Saving Timer to verify satisfactory results. Notes: If normal car or people traffic pass close to the detection area, adjust the detection... this causes a problem, adjust the detection length to ON. 6 Perform a Walk Test NOTE: With the Walk Test switch set to position "B". Replace the cover. 2. This also allows for false or unwanted detections. 4. When the programming is complete ensure the Walk Test switch is set to OFF...
... perform a walk test to verify satisfactory results. 7 Program the Control Panel Prior to use the Walk Test setting or temporally set the Battery Saving Timer to verify satisfactory results. Notes: If normal car or people traffic pass close to the detection area, adjust the detection... this causes a problem, adjust the detection length to ON. 6 Perform a Walk Test NOTE: With the Walk Test switch set to position "B". Replace the cover. 2. This also allows for false or unwanted detections. 4. When the programming is complete ensure the Walk Test switch is set to OFF...
Installation Instructions
Page 6
...is detecting moving trees, or bushes or a strong light source. Try a higher sensitivity setting. Check for correct battery installation, or replace dead batteries. Batteries are very low or dead. Water in the area may be causing an abrupt temperature change. Transmitter or PIR ...REMEDY Check for moving trees, bushes, or a strong source of heat, or shorten the Detection Length. - 6 - Replace unit. Move or remove the heat source. Low battery fault indicated on system keypad display. Detection area is not perpendicular to the ground. Remount and align sensor so the detection...
...is detecting moving trees, or bushes or a strong light source. Try a higher sensitivity setting. Check for correct battery installation, or replace dead batteries. Batteries are very low or dead. Water in the area may be causing an abrupt temperature change. Transmitter or PIR ...REMEDY Check for moving trees, bushes, or a strong source of heat, or shorten the Detection Length. - 6 - Replace unit. Move or remove the heat source. Low battery fault indicated on system keypad display. Detection area is not perpendicular to the ground. Remount and align sensor so the detection...