End User License Agreement
Page 1
... internet and was originally licensed for use on those computers. You may not separate component parts of the Software Product for CONDITIONS OF THIS EULA. HP and its suppliers. END-USER LICENSE AGREEMENT PLEASE READ CAREFULLY BEFORE USING THIS EQUIPMENT: This End-User license Agreement ("EULA") is a legal agreement... the terms and conditions of this EULA. You do not have Software Product into Your Computer's AGREE TO ALL TERMS AND temporary memory (RAM) for use on more than one computer, you may install and use the Software Product on or made available by...
... internet and was originally licensed for use on those computers. You may not separate component parts of the Software Product for CONDITIONS OF THIS EULA. HP and its suppliers. END-USER LICENSE AGREEMENT PLEASE READ CAREFULLY BEFORE USING THIS EQUIPMENT: This End-User license Agreement ("EULA") is a legal agreement... the terms and conditions of this EULA. You do not have Software Product into Your Computer's AGREE TO ALL TERMS AND temporary memory (RAM) for use on more than one computer, you may install and use the Software Product on or made available by...
new power management for hp desktop pcs
Page 2
...program states are increasingly being used in personal computers. You can automatically reload the last state and continue operation. • Suspend to RAM This is similar to the Hibernate mode described above, only there is less power saving and wakeup is faster, since the system ... and PC availability. This is available 24 hours a day, with power management tasks. APM Advance Power Management (APM) was provided on selected HP PCs. • Highly configurable Since control is restored when the PC can select very low power sleep states (Hibernate) or ultra-fast wakeup...
...program states are increasingly being used in personal computers. You can automatically reload the last state and continue operation. • Suspend to RAM This is similar to the Hibernate mode described above, only there is less power saving and wakeup is faster, since the system ... and PC availability. This is available 24 hours a day, with power management tasks. APM Advance Power Management (APM) was provided on selected HP PCs. • Highly configurable Since control is restored when the PC can select very low power sleep states (Hibernate) or ultra-fast wakeup...
new power management for hp desktop pcs
Page 3
... main memory and is in Windows 2000. The operating system shuts down . During wakeup from S5 mode. Check the HP websites dedicated to hard disk and is not currently used for a fast S4 Hibernate startup. You can be configured to...off . S5 Shut Down In ACPI, called 'Suspend to Become Available In ACPI, called Soft Off. However, new HP BIOSs will support RPO from S5, the BIOS re-initializes and the operating system performs a complete reboot. ACPI Power ...image. Not Used PC Power Use (proportional) 100% Time Required by the PC to RAM'. The lightest sleep state.
... main memory and is in Windows 2000. The operating system shuts down . During wakeup from S5 mode. Check the HP websites dedicated to hard disk and is not currently used for a fast S4 Hibernate startup. You can be configured to...off . S5 Shut Down In ACPI, called 'Suspend to Become Available In ACPI, called Soft Off. However, new HP BIOSs will support RPO from S5, the BIOS re-initializes and the operating system performs a complete reboot. ACPI Power ...image. Not Used PC Power Use (proportional) 100% Time Required by the PC to RAM'. The lightest sleep state.
new power management for hp desktop pcs
Page 4
...late-night backup) • A wakeup command from Start>Settings>Control Panel>System>Device Manager). Under Windows 2000, ensure the OS option "Suspend to RAM" mode (S3) works in Start>Settings>Control Panel>Power Options if you have set the action of all devices are powered off , becoming quickly ...available for the task at hand. In this way the PC starts up from "Suspend to RAM mode (this feature) • A scheduled event (such as 'active' in Power Management, or go into Hibernate mode (S4) if this mode. ...
...late-night backup) • A wakeup command from Start>Settings>Control Panel>System>Device Manager). Under Windows 2000, ensure the OS option "Suspend to RAM" mode (S3) works in Start>Settings>Control Panel>Power Options if you have set the action of all devices are powered off , becoming quickly ...available for the task at hand. In this way the PC starts up from "Suspend to RAM mode (this feature) • A scheduled event (such as 'active' in Power Management, or go into Hibernate mode (S4) if this mode. ...
new power management for hp desktop pcs
Page 5
... 98 Second Edition or Windows 2000, Microsoft's latest operating systems which of these systems, HP recommends that you to choose the power management scheme to best fit your desktop right-click...for the HP PC User From the user's point of view, many of the advantages of ACPI when you have both APM and ACPI implemented in mode S1 or Suspend to RAM mode S3..., test by default. To set a device input to wake-up capabilities of the hardware present, as some time. If you can only be available early in the OS, the software will be woken from mode S1. However, HP...
... 98 Second Edition or Windows 2000, Microsoft's latest operating systems which of these systems, HP recommends that you to choose the power management scheme to best fit your desktop right-click...for the HP PC User From the user's point of view, many of the advantages of ACPI when you have both APM and ACPI implemented in mode S1 or Suspend to RAM mode S3..., test by default. To set a device input to wake-up capabilities of the hardware present, as some time. If you can only be available early in the OS, the software will be woken from mode S1. However, HP...
HP Vectra VEi7, VEi8 & VLi8, Technical Reference Manual (Vectra Technology)
Page 11
... buses: the PCI bus, the SM bus and the ISA bus. The two chips that make up the Intel 440ZX AGPset are : • 512MB of RAM supported instead of PC. The 440ZX chip set is derived from and has the same benchmarks as the Host, or Front Side Bus), the main...
... buses: the PCI bus, the SM bus and the ISA bus. The two chips that make up the Intel 440ZX AGPset are : • 512MB of RAM supported instead of PC. The 440ZX chip set is derived from and has the same benchmarks as the Host, or Front Side Bus), the main...
HP Vectra VEi7, VEi8 & VLi8, Technical Reference Manual (Vectra Technology)
Page 31
Core Components and Technologies Crystal Integrated PCI Audio File Formats Windows audio files RealAudio and RealVideo streams AVI (Audio Visual Interleave) video files MPEG video files QuickTime® audio video files Sun™ Microsystems and NeXT™ audio files File Extension .wav .asx .asf .ra .ram .rm .rmm .avi .mpg .mpeg .m1v .mp2 .mpa .mpe .qt .aif .aifc .aiff .mov .au .snd 31
Core Components and Technologies Crystal Integrated PCI Audio File Formats Windows audio files RealAudio and RealVideo streams AVI (Audio Visual Interleave) video files MPEG video files QuickTime® audio video files Sun™ Microsystems and NeXT™ audio files File Extension .wav .asx .asf .ra .ram .rm .rmm .avi .mpg .mpeg .m1v .mp2 .mpa .mpe .qt .aif .aifc .aiff .mov .au .snd 31
HP Vectra VEi7, Troubleshooting and Upgrade Guide
Page 15
...memory bus1 ROM copyright notice check failure Unexpected interrupts test failure Video configuration failure or option ROMs check-sum failure No RAM installed Inform HP support/HP reseller that system board is defective. Beep Pattern Beep Numeric Code Code Description Recommended Action 1-2-2-3 16h 1-3-1-1 20h 1-3-1-3 ...refresh test failure1 8042 Keyboard controller test failure RAM failure on a SCSI card. If the error still occurs, replace the module. If the error still occurs, replace the module. Inform HP support/HP reseller that system board is correctly installed....
...memory bus1 ROM copyright notice check failure Unexpected interrupts test failure Video configuration failure or option ROMs check-sum failure No RAM installed Inform HP support/HP reseller that system board is defective. Beep Pattern Beep Numeric Code Code Description Recommended Action 1-2-2-3 16h 1-3-1-1 20h 1-3-1-3 ...refresh test failure1 8042 Keyboard controller test failure RAM failure on a SCSI card. If the error still occurs, replace the module. If the error still occurs, replace the module. Inform HP support/HP reseller that system board is correctly installed....
HP Vectra VEi7, Troubleshooting and Upgrade Guide
Page 29
... unusable) when running but some software won't run Windows NT 4.0 on your operating system utilities or the Setup program. You need at least 64MB of RAM to run . To change the date and time, use your PC. If it . 1 Troubleshooting Your PC If Your PC Has a Software Problem If Your PC...
... unusable) when running but some software won't run Windows NT 4.0 on your operating system utilities or the Setup program. You need at least 64MB of RAM to run . To change the date and time, use your PC. If it . 1 Troubleshooting Your PC If Your PC Has a Software Problem If Your PC...
HP Vectra VEi7, Troubleshooting and Upgrade Guide
Page 39
...Test). Any POST errors will help HP support deal with non-HP RAM. Make a list of your problem quickly and efficiently: Model number Serial number RAM • Number of megabytes installed • HP RAM or RAM from another manufacturer Write down a brief description of RAM is displayed in the Setup Main...• The amount of the problem Frequency Run OK? Operating System Select Settings Control Panel from the support Web site: www.hp.com/go/vectrasupport. Any BIOS parameter changes? Recent changes to check for example, LAN, sound and SCSI) Are you using the Setup...
...Test). Any POST errors will help HP support deal with non-HP RAM. Make a list of your problem quickly and efficiently: Model number Serial number RAM • Number of megabytes installed • HP RAM or RAM from another manufacturer Write down a brief description of RAM is displayed in the Setup Main...• The amount of the problem Frequency Run OK? Operating System Select Settings Control Panel from the support Web site: www.hp.com/go/vectrasupport. Any BIOS parameter changes? Recent changes to check for example, LAN, sound and SCSI) Are you using the Setup...
HP Vectra VEi7, User's Guide
Page 24
... what is displayed under System. Have there been any recent changes made to the PC? Any POST errors will help HP support deal with non-HP RAM. PC Description See label on Your PC Before Contacting Support Note down some compatibility problems with your PC. Question or...Please note down a brief description of your problem quickly and efficiently: Model number Serial number RAM • Number of megabytes installed • HP RAM or RAM from the support Web site: www.hp.com/go/vectrasupport. Hardware Configuration The BIOS version is displayed in the Setup program main menu,...
... what is displayed under System. Have there been any recent changes made to the PC? Any POST errors will help HP support deal with non-HP RAM. PC Description See label on Your PC Before Contacting Support Note down some compatibility problems with your PC. Question or...Please note down a brief description of your problem quickly and efficiently: Model number Serial number RAM • Number of megabytes installed • HP RAM or RAM from the support Web site: www.hp.com/go/vectrasupport. Hardware Configuration The BIOS version is displayed in the Setup program main menu,...
HP Vectra VEi8, Service Handbook
Page 1
... 8 PC Models and Accessories Product Hard Number Drive Video Controller Std. RAM Multi-media LAN OS1 Vectra VEi 8 PC Models with Intel Pentium III Processor, 100 MHz System Bus Speed, and 512 KB Level 2 Cache Memory W95 NT 4.0 WS W95 W95 + Word HP Vectra VEi 8 PC 450 (CPL: 04/99 ) D8171A/T 4.3 GB IDE D8172N... 8 PC Models with Intel Pentium II Processor, 100 MHz System Bus Speed, and 512 KB Level 2 Cache Memory HP Vectra VEi 8 PC 400 (CPL: 04/99 ) D8151A/T 4.3 GB IDE D8152N/T Integrated 32 MB no Matrox SDRAM MGA-G200 AGP 100 MHz (8 MB SGRAM fitted, not ...
... 8 PC Models and Accessories Product Hard Number Drive Video Controller Std. RAM Multi-media LAN OS1 Vectra VEi 8 PC Models with Intel Pentium III Processor, 100 MHz System Bus Speed, and 512 KB Level 2 Cache Memory W95 NT 4.0 WS W95 W95 + Word HP Vectra VEi 8 PC 450 (CPL: 04/99 ) D8171A/T 4.3 GB IDE D8172N... 8 PC Models with Intel Pentium II Processor, 100 MHz System Bus Speed, and 512 KB Level 2 Cache Memory HP Vectra VEi 8 PC 400 (CPL: 04/99 ) D8151A/T 4.3 GB IDE D8152N/T Integrated 32 MB no Matrox SDRAM MGA-G200 AGP 100 MHz (8 MB SGRAM fitted, not ...
HP Vectra VEi8, Service Handbook
Page 2
...-bit SDRAM, 100 MHz ECC main memory module D6501A/T D6504A/T D6502A/T D6505A/T D6503A/T D6743A/T Documentation User's Guide Manual Kit D8110A 16-2 HP Vectra VEi 8 PC Medium-Profile Desktop Vectras RAM Multi-media LAN OS1 HP Vectra VEi 8 PC 500 (CPL: 04/99 ) D8183A 8.4 GB Integrated 64 MB 32 ! Max IDE no W95 IDE Matrox SDRAM CD...
...-bit SDRAM, 100 MHz ECC main memory module D6501A/T D6504A/T D6502A/T D6505A/T D6503A/T D6743A/T Documentation User's Guide Manual Kit D8110A 16-2 HP Vectra VEi 8 PC Medium-Profile Desktop Vectras RAM Multi-media LAN OS1 HP Vectra VEi 8 PC 500 (CPL: 04/99 ) D8183A 8.4 GB Integrated 64 MB 32 ! Max IDE no W95 IDE Matrox SDRAM CD...
HP Vectra VEi8, Technical Reference Manual (Product Description)
Page 24
...-85 Hz 60-85 Hz 1152 ! 8642 60-85 Hz 1280 ! 1024 60-85 Hz 1600 ! 1200 60-85 Hz 1. Bits per pixel 2. The video RAM (also known as the frame buffer) is currently displayed on the system board. Connectors A 15-pin VGA DB connector is located on the rear panel... on the screen), and the off-screen surface (video frame, fonts, double buffer). 2 System Features 8MB Matrox Millennium G200 AGP 2X Graphics Chip Video Memory HP Vectra VEi 8 PCs are supplied with 8 MB of SDRAM for its location). 15-pin VGA DB Connector 24
...-85 Hz 60-85 Hz 1152 ! 8642 60-85 Hz 1280 ! 1024 60-85 Hz 1600 ! 1200 60-85 Hz 1. Bits per pixel 2. The video RAM (also known as the frame buffer) is currently displayed on the system board. Connectors A 15-pin VGA DB connector is located on the rear panel... on the screen), and the off-screen surface (video frame, fonts, double buffer). 2 System Features 8MB Matrox Millennium G200 AGP 2X Graphics Chip Video Memory HP Vectra VEi 8 PCs are supplied with 8 MB of SDRAM for its location). 15-pin VGA DB Connector 24
HP Vectra VEi8, Technical Reference Manual (Product Description)
Page 32
... associated with the Real Time Clock hardware, bypassing the BIOS and the operating system. Displays the extended memory size. Enable to free address space in RAM for example, the Pentium III. Select No if your applications interface directly with it . • Cache...
... associated with the Real Time Clock hardware, bypassing the BIOS and the operating system. Displays the extended memory size. Enable to free address space in RAM for example, the Pentium III. Select No if your applications interface directly with it . • Cache...
HP Vectra VEi8, Technical Reference Manual (Product Description)
Page 36
... 0000 0400 - 0000 04FF BIOS Data Area 0000 0500 - 0009 FC00 Used by OS 0009 FC00 - 0009 FFFF Extended BIOS Data Area 000A_0000 - 000B_FFFF Video RAM or SMRAM (not visible unless in the area from C8000h to 512 MB) FFFC0000 - As soon as the POST has been completed, the E0000-E8000... used by accessory boards must be located in SMM) 000C 0000 - 000C 7FFF Video ROM 000C 8000 - 000F FFFF 000E 0000 - 000F FFFF Adapter ROM, RAM, memory-mapped registers System BIOS (Flash/Shadow)1 10 0000 -
... 0000 0400 - 0000 04FF BIOS Data Area 0000 0500 - 0009 FC00 Used by OS 0009 FC00 - 0009 FFFF Extended BIOS Data Area 000A_0000 - 000B_FFFF Video RAM or SMRAM (not visible unless in the area from C8000h to 512 MB) FFFC0000 - As soon as the POST has been completed, the E0000-E8000... used by accessory boards must be located in SMM) 000C 0000 - 000C 7FFF Video ROM 000C 8000 - 000F FFFF 000E 0000 - 000F FFFF Adapter ROM, RAM, memory-mapped registers System BIOS (Flash/Shadow)1 10 0000 -
HP Vectra VEi7, Intel EtherExpress PRO 10+ ISA Ethernet Adapter, Installation Guide
Page 4
...to disable the Flash memory feature on the NIC. Go to go to start the Flashstart utility again on VEi8: 8 Message "EtherExpress PRO flash routines disabled. ROM shadowing problem." appears when warm or cold booting the... Save settings and exit SOFTSET2. 6 Reboot the system. 7 The Intel Flashstart configuration utility starts by the NIC flash ram. Press the spacebar twice to go into DOS 6.22. 2 Run Intel's SOFTSET2 utility. Note that after exiting,... to applicable OS. 5 Remote boot: 6 Remote boot fails HP tests on Vectra VEi7. 7 Message during boot on the next reboot.
...to disable the Flash memory feature on the NIC. Go to go to start the Flashstart utility again on VEi8: 8 Message "EtherExpress PRO flash routines disabled. ROM shadowing problem." appears when warm or cold booting the... Save settings and exit SOFTSET2. 6 Reboot the system. 7 The Intel Flashstart configuration utility starts by the NIC flash ram. Press the spacebar twice to go into DOS 6.22. 2 Run Intel's SOFTSET2 utility. Note that after exiting,... to applicable OS. 5 Remote boot: 6 Remote boot fails HP tests on Vectra VEi7. 7 Message during boot on the next reboot.