HP StorageWorks 2012sa Support and Manuals
Get Help and Manuals for this Hewlett-Packard item
This item is in your list!
View All Support Options Below
Free HP StorageWorks 2012sa manuals!
Problems with HP StorageWorks 2012sa?
Ask a Question
Free HP StorageWorks 2012sa manuals!
Problems with HP StorageWorks 2012sa?
Ask a Question
Popular HP StorageWorks 2012sa Manual Pages
Hp StorageWorks 2000 Family Modular Smart Array CLI reference guide (481600-002, May 2008) - Page 1
HP StorageWorks 2000 Family Modular Smart Array CLI reference guide
Part number: 481600-002 Second edition: May 2008
Hp StorageWorks 2000 Family Modular Smart Array CLI reference guide (481600-002, May 2008) - Page 4
...-metadata 45 clear event 46 clear expander-status 47 convert master-to-std 48 convert std-to-master 49 create chap-record 50
4 HP StorageWorks 2000 Family Modular Smart Array CLI reference guide • May 2008 Command Completion, Editing, and History 28 Viewing Command Help 29 Size of Devices and Logical Units 29 Event Log 30...
Hp StorageWorks 2000 Family Modular Smart Array CLI reference guide (481600-002, May 2008) - Page 18
if ( !cLogin($ipAddr, $username, $password) == 1 ) {
print("Error: $username user failed to construct a script using a Perl library for telnet communication. Exiting.\n"); $telnet->close; exit(0); }
18
HP StorageWorks 2000 Family Modular Smart Array CLI reference guide • May 2008 use Net::Telnet; $mVer = "v.072006"; $mLine mStr = "Management Controller System Cloning Utility"; $nLine...
Hp StorageWorks 2000 Family Modular Smart Array CLI reference guide (481600-002, May 2008) - Page 20
Elements and attributes are described in the table on the following is Revision 1 of the DTD. DTD
The following page.
20
HP StorageWorks 2000 Family Modular Smart Array CLI reference guide • May 2008
Hp StorageWorks 2000 Family Modular Smart Array CLI reference guide (481600-002, May 2008) - Page 22
...set to console and second set to api.
# set cli-parameters console Success: CLI parameter changed successfully
# show schedule-details Sched1 Schedule Details Schedule Name: Sched1 Schedule Specification...: none Error Message: none
Snapshot Name
Snapshot Serial
ss_S0003
00c0ff0a43010048f9ca2d4601000000
22
HP StorageWorks 2000 Family Modular Smart Array CLI reference guide • May...
Hp StorageWorks 2000 Family Modular Smart Array CLI reference guide (481600-002, May 2008) - Page 24
00c0ff0a43010048f9ca2d4601000000
ss
3
none
none
24
HP StorageWorks 2000 Family Modular Smart Array CLI reference guide • May 2008
Hp StorageWorks 2000 Family Modular Smart Array CLI reference guide (481600-002, May 2008) - Page 26
...example specifies a serial number and a name:
AA43BF501234560987654321FEDCBA,"Vol #1"
26
HP StorageWorks 2000 Family Modular Smart Array CLI reference guide • May 2008 This example specifies a name and a serial number... the name parameter. ■ Virtual disk serial number. Some commands do not support lists. To use a name that the CLI could interpret as an optional parameter, ...
Hp StorageWorks 2000 Family Modular Smart Array CLI reference guide (481600-002, May 2008) - Page 28
You can complete it . Command Completion, Editing, and History
The CLI supports command completion, command editing, and command history.
To
Press
Complete a...
Enter command and redisplay prompt Ctrl-Z
Refresh input line
Ctrl-L
28
HP StorageWorks 2000 Family Modular Smart Array CLI reference guide • May 2008 The history contains all commands entered in the active CLI session.
Hp StorageWorks 2000 Family Modular Smart Array CLI reference guide (481600-002, May 2008) - Page 30
Events that have occurred in or been detected by the controller modules and encompasses all field-replaceable units (FRUs) in decreasing severity: ■ Critical.
Events that do not affect data integrity. ■...Log
A controller enclosure's event log records all events that show events" on page 181.
30
HP StorageWorks 2000 Family Modular Smart Array CLI reference guide • May 2008
HP StorageWorks 2000 Modular Smart Array Controller Module Replacement Instructions (488318-003, April 2010) - Page 1
...instructions.
*488318-003*
IMPORTANT: When two controllers are installed in an enclosure, they must be populated for replacing a failed controller module in an HP StorageWorks 2012/2212 Modular Smart Array... the HP website at http:// www.hp.com/support/manuals. use proper anti-static protection. HP StorageWorks
2000 Modular Smart Array Controller Module Replacement Instructions
About this...
HP StorageWorks 2012sa Modular Smart Array firmware release notes Version J300P10-01 (508849-001, November 2008) - Page 1
HP StorageWorks 2012sa Modular Smart Array firmware release notes
Version J300P10-01
Part number: 508849-001 First edition: November 2008
HP StorageWorks 2012sa Modular Smart Array firmware release notes Version J300P10-01 (508849-001, November 2008) - Page 3
....
Supersedes J300P07-01
Product models
HP StorageWorks 2012sa Modular Smart Array (MSA2012sa)
Enhancements
• Added support for HP External SAS Shared Solution for the firmware indicated above. Because the online firmware upgrade is displayed when adding a vdisk spare when no disk drives are
available. • Corrected a validation error on Windows Server 2003, allowing...
HP StorageWorks 2012sa Modular Smart Array firmware release notes Version J300P10-01 (508849-001, November 2008) - Page 5
... change the setting although the message indicates success. HP StorageWorks 2012sa Modular Smart Array firmware release notes
5 To update the maps at the multipath driver level. After...array is working on Red Hat Linux 4 Update 6 hosts using the command: restart mc a (single controller) or restart mc both MSA2012sa storage controllers. After installing the 4.00.13.04-2 driver...
HP StorageWorks 2012sa Modular Smart Array user (488320-004, March 2013) - Page 12
HP StorageWorks MSA2000 Family Storage Management Utility (SMU)
SMU is in its online help and in each controller module. Information about using the CLI is properly configured and that is in the CLI reference guide.
12
HP 2012sa Modular Smart Array user guide • January 2013
A web server resides in the reference guide. Command-Line Interface (CLI)
The embedded CLI enables...
HP StorageWorks 2012sa Modular Smart Array user (488320-004, March 2013) - Page 38
... discover "HP StorageWorks MSA2000 Family" storage devices on the local LAN through the host's ARP table.
Look in the following order:
1. Use a ping broadcast to try to preserve the previous enclosure IDs if possible. To correct this condition, see "Setting Management Port IP Addresses Using the CLI" on page 55.
38
HP 2012sa Modular Smart Array user guide •...
HP StorageWorks 2012sa Reviews
Do you have an experience with the HP StorageWorks 2012sa that you would like to share?
Earn 750 points for your review!
We have not received any reviews for HP yet.
Earn 750 points for your review!