.HP StorageWorks SAN Design Reference Guide, Parts 1-5 (AA-RWPYF-TE, February 2010) - Page 249
... 108.
7
EVA4400 (without the embedded switch module) with XCS 09x and
EVA4000/4100/6000/6100/6400/8000/8100/8400 are supported with 8 Gb/s, 4 Gb/s,
or 2 Gb/s switch or HBA direct connectivity only ...layered multipathing driver functionality. For exceptions, see "Single path implementation" in the HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array User Guide, available at 4 Gb/s or 2 Gb/s.
.HP StorageWorks SAN Design Reference Guide, Parts 1-5 (AA-RWPYF-TE, February 2010) - Page 250
...-party cooperative support agreement between HP Services and
250 EVA storage system rules EVA
XL storage system support includes support for information about the OCP.
Direct connect is not supported with Brocade HBAs.
• In an HP-UX environment, direct connect is supported with QLogic 8 Gb HBAs. See the HP StorageWorks 4400 Enterprise Virtual Array installation guide for mixed...
.HP StorageWorks SAN Design Reference Guide, Parts 1-5 (AA-RWPYF-TE, February 2010) - Page 254
... in this particular license, you follow the rules described in a fabric with embedded switch • EVA4000/4100/6000/6100/8000/8100 • EVA6400/8400
For current data migration storage system support, see the HP StorageWorks Enterprise Virtual Array compatibility reference matrix at http://www.hp.com/ storage/spock. See "Data availability" on the limits for offline data migration...
.HP StorageWorks SAN Design Reference Guide, Parts 1-5 (AA-RWPYF-TE, February 2010) - Page 255
...no solution exceeds the 16-array limit, imposed
by product-specific configuration guidelines (see the HP StorageWorks Enterprise Virtual Array
compatibility reference).
The active appliance and
Command View EVA can contain 16 EVAs; These rules apply to configurations that are governed by zoning.
6
The maximum number of copy sets, DR groups, and remote copy sets is the total number...
.HP StorageWorks SAN Design Reference Guide, Parts 1-5 (AA-RWPYF-TE, February 2010) - Page 314
... Extension SAN Switches that support Continuous Access with FCIP can be directly connected to the Fibre Channel ports on the 1606 Extension SAN Switch (Figure 107).
314 SAN extension For information about the 1606 Extension SAN Switch and DC Dir Switch MP Extension Blade, see the HP StorageWorks Enterprise Virtual Array compatibility reference matrix at http...
.HP StorageWorks SAN Design Reference Guide, Parts 1-5 (AA-RWPYF-TE, February 2010) - Page 317
...supported with nondedicated bandwidth. For information about the 400 MP Router and MP Router Blade, see the HP StorageWorks Enterprise Virtual Array compatibility reference matrix at http://h18006.www1.hp.com/products/storage/ software/conaccesseva/index.html. SAN Design Reference Guide...minimum of firmware 5.2.0a. For firmware version 6.3.x, version 6.3.0c or later is supported with B-series...
.HP StorageWorks SAN Design Reference Guide, Parts 1-5 (AA-RWPYF-TE, February 2010) - Page 320
... 2
FCIP portcfgfcip [-m LOAD_BAL (1-exchange, 2-SID_DID, 3-none]
The default is not supported for Continuous Access EVA must set this value to MP Router ports (F_Ports) is supported with iSCSI (see the HP StorageWorks Enterprise Virtual Array compatibility reference matrix at http://h18006.www1.hp.com/products/storage/ software/conaccesseva/index.html.
Documentation
For information...
.HP StorageWorks SAN Design Reference Guide, Parts 1-5 (AA-RWPYF-TE, February 2010) - Page 323
... Continuous Access EVA, see the HP StorageWorks Enterprise Virtual Array compatibility reference matrix at http://h18006.www1.hp.com/products/storage/software/ conaccesseva/index.html. Storage systems
Continuous Access EVA XP Continuous Access
Notes:
• Contact an HP storage representative for the C-series modules. XP Continuous Access supports a load balance setting of scr-dst-id or scr...
.HP StorageWorks SAN Design Reference Guide, Parts 1-5 (AA-RWPYF-TE, February 2010) - Page 435
... Data.
HP StorageWorks Enterprise Virtual Array. A network of one or more Fibre Channel switches that allows C-series switches to a secondary, identical system.
A comprehensive set of devices...in C-series fabric binding configurations. Enterprise Systems Connection. Fibre Channel Disk Module. SAN Design Reference Guide 435 An encryption cipher mode. HP SAN backup software. A high-performance...
.HP StorageWorks SAN Design Reference Guide, Parts 1-5 (AA-RWPYF-TE, February 2010) - Page 442
... one common zone cannot communicate through a fabric. Xcelerated Controller Software. The software that runs in the HSV controller-based Enterprise Virtual Array XL model storage systems.
An HP StorageWorks product consisting of two or more XP disk arrays performing disk-to-disk replication, and a management user interface that communicate with pWWN. Synonymous with each other through the...
HP StorageWorks EVA Virtualization Adapter release notes (5697-0307, February 2010) - Page 3
... 4.00.00
Product models
• HP StorageWorks EVA Virtualization Adapter for Windows
Devices supported
• HP StorageWorks 8400 EVA Storage System (Firmware XCS v9.xx) • HP StorageWorks 8100 EVA Storage System (Firmware XCS v.6.2xx, 6.110) • HP StorageWorks 8000 EVA Storage System (Firmware XCS v.6.2xx, 6.110) • HP StorageWorks 6400 EVA Storage System (Firmware XCS v9.xx...
HP StorageWorks EVA4000 SAN Starter Kit Release Notes (5697-6628, April 2007) - Page 3
... under Storage, and then select HP StorageWorks 4000/6000/8000 Enterprise Virtual Arrays under EVA Disk Arrays.
This document contains the most recent product information for implementing a storage area network (SAN).
Much of the information is available from the Manuals page of the HP Business Support Center website:
http://www.hp.com/support/manuals
Table 1 Information sources
Topic...
HP StorageWorks EVA4000 SAN Starter Kit Release Notes (5697-6628, April 2007) - Page 7
...
EVA4000 controller firmware XCS 6.100 is available for download on the HP Software Depot website: http://h20293.www2.hp.com/ Select Storage and NAS under Product category, and then select HP EVA XCS 6.100 Electronic Download to receive two .ISO images from which you have difficulty with the EZPilot installation, see the HP StorageWorks 4000/6000/8000 Enterprise Virtual Array release notes...
HP StorageWorks MPX200 Multifunction Router release notes (5697-0019, June 2009) - Page 3
... models of Fibre Channel (FC) storage systems is supported for integrated iSCSI connectivity using the MPX200 Multifunction Router. Version: 1.0
Description
The HP StorageWorks Enterprise Virtual Array (EVA) family of the MPX200 Multifunction Router are available: • HP StorageWorks MPX200 Multifunction Router 1 GbE base chassis (AP771A)-Order with an
EVA storage system or to upgrade...
HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array read me first (5697-8033, April 2009) - Page 1
...
An HP authorized service provider will assist with the installation of the HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array release notes and other documentation from the following website: http://www.hp.com/support/manuals Click Disk Storage Systems under storage, and then select HP StorageWorks 4000/6000/8000 Enterprise Virtual Arrays, HP StorageWorks 4100 Enterprise Virtual Array, HP...
HP StorageWorks 4000/6000/8000 Reviews
Do you have an experience with the HP StorageWorks 4000/6000/8000 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for HP yet.
Earn 750 points for your review!