Testing on HP Business Desktop PCs
Page 4
..., supported BIOS features, and expected BIOS interoperability with the platform hardware and software. • System Board-This is conducted to help make sure that voltage regulators on Business Desktop PCs to replicate the manner in the power supply remain within HP Business Desktop specifications...interfaces, power delivery to the customer is conducted and measured on the signal quality of the chipset functionality/feature set, subsystem (i.e., CPU, Memory, Graphics, Audio, PCI/PCIE, NIC, USB, IDE, LPC, etc.), and associated hardware components. 4 Additionally, voltage...
..., supported BIOS features, and expected BIOS interoperability with the platform hardware and software. • System Board-This is conducted to help make sure that voltage regulators on Business Desktop PCs to replicate the manner in the power supply remain within HP Business Desktop specifications...interfaces, power delivery to the customer is conducted and measured on the signal quality of the chipset functionality/feature set, subsystem (i.e., CPU, Memory, Graphics, Audio, PCI/PCIE, NIC, USB, IDE, LPC, etc.), and associated hardware components. 4 Additionally, voltage...
HP Disk Sanitizer, External Edition
Page 5
...drives except the drive to be erased in order to ensure that you change to IDE mode before running this utility in the future, the CPU will be a small section of non-personal metadata used in mirrored mode (Raid 1), one 80GB hard drive will be detected, but both drives...erased. If a user boots from a USB drive key, the first drive to keep in mind that you run this utility. RAID Configuration HP Disk Sanitizer, External Edition supports RAID configuration. If two 80GB hard drives are not to avoid erasing the wrong drive. While multiple drives can execute, the ...
...drives except the drive to be erased in order to ensure that you change to IDE mode before running this utility in the future, the CPU will be a small section of non-personal metadata used in mirrored mode (Raid 1), one 80GB hard drive will be detected, but both drives...erased. If a user boots from a USB drive key, the first drive to keep in mind that you run this utility. RAID Configuration HP Disk Sanitizer, External Edition supports RAID configuration. If two 80GB hard drives are not to avoid erasing the wrong drive. While multiple drives can execute, the ...
Desktop Management Guide
Page 12
... automatically updates any or all supported HP business desktop, notebook, and workstation models. HP System Software Manager HP System Software Manager (SSM) is integrated into HP Client Manager, and enables central tracking, monitoring, and management of the hardware aspects of HP client systems. Use HP Client Manager to: ● Get valuable hardware information such as CPU, memory, video, and security...
... automatically updates any or all supported HP business desktop, notebook, and workstation models. HP System Software Manager HP System Software Manager (SSM) is integrated into HP Client Manager, and enables central tracking, monitoring, and management of the hardware aspects of HP client systems. Use HP Client Manager to: ● Get valuable hardware information such as CPU, memory, video, and security...
BIOS Flash Q&A
Page 14
...Packard computers which have a BIOS administrative/setup password set . However, it is complete, the business PC can be booted from Windows XP Professional, the following information would require the user to those also support the creation of the DOS Flash directory (i.e. Flashbin.exe, Assignpw.exe, and BIOS image file ... before coping the contents of a bootable CD emulating a hard disk. For BIOS images that contains Flashbin.exe and type assignpw flsh.cpu. The third party CD software can be executed on a floppy diskette, bootable CD with the /s option to the media.
...Packard computers which have a BIOS administrative/setup password set . However, it is complete, the business PC can be booted from Windows XP Professional, the following information would require the user to those also support the creation of the DOS Flash directory (i.e. Flashbin.exe, Assignpw.exe, and BIOS image file ... before coping the contents of a bootable CD emulating a hard disk. For BIOS images that contains Flashbin.exe and type assignpw flsh.cpu. The third party CD software can be executed on a floppy diskette, bootable CD with the /s option to the media.
HP Compaq dc7700 Business Desktop PC Service Reference Guide, 1st Edition
Page 34
...remotely from the system management console of device drivers and BIOS updates for supported HP business desktop, notebook, and workstation models. Since SSM only allows distribution of SoftPaq...integration with HP Instant Support tools reduces hardware troubleshooting time. ■ Diagnostics-remotely run & view reports on the client system 3-4 433612-001 Service Reference Guide, dc7700 SSM may...■ Identify, inventory, and initialize systems with enterprise software distribution tools such as CPU, memory, video, and security settings ■ Monitor system health to fix problems ...
...remotely from the system management console of device drivers and BIOS updates for supported HP business desktop, notebook, and workstation models. Since SSM only allows distribution of SoftPaq...integration with HP Instant Support tools reduces hardware troubleshooting time. ■ Diagnostics-remotely run & view reports on the client system 3-4 433612-001 Service Reference Guide, dc7700 SSM may...■ Identify, inventory, and initialize systems with enterprise software distribution tools such as CPU, memory, video, and security settings ■ Monitor system health to fix problems ...
HP Compaq dc7700 Convertible Minitower Business PC Illustrated Parts & Service Map, 3rd Edition
Page 3
... for PCI 12 Mouse 13 Coprocessor 14 Primary ATA (IDE) Controller 15 Secondary ATA (IDE) Controller dc7700 Illustrated Parts & Service Map, CMT Chassis 435524-003 page 3 Allows you to select a drive containing...SATA2 P1 24-pin main power P63 SATA3 P3 CPU power XBT 1 Real-time-clock battery P5 Front power button/LED XMM1 DIMM ...power management, hardware, and passwords is accessed by pressing the F10 key when prompted (on authentication support, reset device to factory settings, and reset authentication credentials. Thermal - The following main system specifications...
... for PCI 12 Mouse 13 Coprocessor 14 Primary ATA (IDE) Controller 15 Secondary ATA (IDE) Controller dc7700 Illustrated Parts & Service Map, CMT Chassis 435524-003 page 3 Allows you to select a drive containing...SATA2 P1 24-pin main power P63 SATA3 P3 CPU power XBT 1 Real-time-clock battery P5 Front power button/LED XMM1 DIMM ...power management, hardware, and passwords is accessed by pressing the F10 key when prompted (on authentication support, reset device to factory settings, and reset authentication credentials. Thermal - The following main system specifications...
HP Compaq dc7700 Convertible Minitower Business PC Illustrated Parts & Service Map, 3rd Edition
Page 4
...a valid BIOS image on the screen. 4. Enter the product number (for proper seating, type, and HP compatibility. 3. System board. 1. Check keyboard connection or keys. Run drive protection system test if available. ...On Computer on Power Green 1 blink every 2 seconds Normal Suspend Mode Power Red 1 blink every second followed CPU thermal shutdown by a 2 second pause Power Red 3 blinks, 1 blink every second Processor not installed followed... Patch Error none Processor not supported by Insight Diagnostics. dc7700 Illustrated Parts & Service Map, CMT Chassis 435524-003 page 4
...a valid BIOS image on the screen. 4. Enter the product number (for proper seating, type, and HP compatibility. 3. System board. 1. Check keyboard connection or keys. Run drive protection system test if available. ...On Computer on Power Green 1 blink every 2 seconds Normal Suspend Mode Power Red 1 blink every second followed CPU thermal shutdown by a 2 second pause Power Red 3 blinks, 1 blink every second Processor not installed followed... Patch Error none Processor not supported by Insight Diagnostics. dc7700 Illustrated Parts & Service Map, CMT Chassis 435524-003 page 4
HP Compaq dx7300 and dc7700 Business PC Technical Reference Guide, 1st Edition
Page 47
...increases processing speed by using higher clock speeds with software written for x86 processors. Technical Reference Guide www.hp.com 3-3 These systems also support the Intel Celeron D processors and the energy-efficient Intel CoreT M 2 Duo processors. data transfer rate)...re-occurring branches are processed. The execution trace cache can store 12 kilobytes of supported processors. Intel PPeenntituiummS4inPgrloecCesosreorProcessor Branch Prediction 16-K Execution Trace Cache CPU Rapid Exe. Dual-core processors feature two cores operating in earlier generation Pentium processors...
...increases processing speed by using higher clock speeds with software written for x86 processors. Technical Reference Guide www.hp.com 3-3 These systems also support the Intel Celeron D processors and the energy-efficient Intel CoreT M 2 Duo processors. data transfer rate)...re-occurring branches are processed. The execution trace cache can store 12 kilobytes of supported processors. Intel PPeenntituiummS4inPgrloecCesosreorProcessor Branch Prediction 16-K Execution Trace Cache CPU Rapid Exe. Dual-core processors feature two cores operating in earlier generation Pentium processors...
HP Compaq dx7300 and dc7700 Business PC Technical Reference Guide, 1st Edition
Page 58
... the fairness algorithm specified by incorporating those functions into packets. 4-6 www.hp.com Technical Reference Guide The use of PCI configuration space and the programmability of interrupts through use . PCI Express protocol supports the three legacy PCI address spaces (memory, I /O devices are designed...and drivers. During system intialization, the PCI Express bus uses the same methods of device discovery and resource allocation that most CPU-to-DRAM accesses can occur concurrently with the PCI 2.2 specification. The bus parking policy allows for hard-wired sideband signals ...
... the fairness algorithm specified by incorporating those functions into packets. 4-6 www.hp.com Technical Reference Guide The use of PCI configuration space and the programmability of interrupts through use . PCI Express protocol supports the three legacy PCI address spaces (memory, I /O devices are designed...and drivers. During system intialization, the PCI Express bus uses the same methods of device discovery and resource allocation that most CPU-to-DRAM accesses can occur concurrently with the PCI 2.2 specification. The bus parking policy allows for hard-wired sideband signals ...
HP Compaq dx7300 and dc7700 Business PC Technical Reference Guide, 1st Edition
Page 68
... 2 (word transfers) 4 Cascade for controller 1. page registers and controller registers. 4-16 www.hp.com Technical Reference Guide For detailed information regarding DMA operation, refer to communicate DMA channel control and...ISA I /O controller such as well. Table 4-9 lists the default configuration of the CPU. The DMA controller 2 can be configured (through PCI Configuration Registers) for one of...DMA through two types of data to transfer blocks of I /O Controller Hub. System Support 4.3.2 Direct Memory Access Direct Memory Access (DMA) is accessed through the SCH5317 I ...
... 2 (word transfers) 4 Cascade for controller 1. page registers and controller registers. 4-16 www.hp.com Technical Reference Guide For detailed information regarding DMA operation, refer to communicate DMA channel control and...ISA I /O controller such as well. Table 4-9 lists the default configuration of the CPU. The DMA controller 2 can be configured (through PCI Configuration Registers) for one of...DMA through two types of data to transfer blocks of I /O Controller Hub. System Support 4.3.2 Direct Memory Access Direct Memory Access (DMA) is accessed through the SCH5317 I ...
HP Compaq dx7300 and dc7700 Business PC Technical Reference Guide, 1st Edition
Page 75
... proper cooling. ✎ Units using chassis and CPU fans must have both fans connected to their corresponding headers to increase speed of fan(s). 4. Technical Reference Guide www.hp.com 4-23 All systems also provide or support an auxiliary chassis fan. All fans are controlled ...form factors and between some models, although the overall functionally is the result of the temperature of the CPU as part of the processor heatsink assembly. System Support 4.5.3 System Status These systems provide a visual indication of system boot, ROM flash, and operational status through...
... proper cooling. ✎ Units using chassis and CPU fans must have both fans connected to their corresponding headers to increase speed of fan(s). 4. Technical Reference Guide www.hp.com 4-23 All systems also provide or support an auxiliary chassis fan. All fans are controlled ...form factors and between some models, although the overall functionally is the result of the temperature of the CPU as part of the processor heatsink assembly. System Support 4.5.3 System Status These systems provide a visual indication of system boot, ROM flash, and operational status through...
HP Compaq dx7300 and dc7700 Business PC Technical Reference Guide, 1st Edition
Page 82
... 2Fh (data) after the configuration phase has been activated by firmware selecting logical device 0 of status bytes (from the CPU to I/O register 2Fh (this selects the diskette drive I /O controller during the Command phase. During periods of the SCH5317...is in which occurs at runtime. Write 30h to 2Eh deactivates the configuration phase. 5-4 www.hp.com Technical Reference Guide The Main Status register (3F4h/374h) provides data flow control for ...Drive Interface The MT and CMT form factors support a diskette drive through a standard 34-pin diskette drive connector.
... 2Fh (data) after the configuration phase has been activated by firmware selecting logical device 0 of status bytes (from the CPU to I/O register 2Fh (this selects the diskette drive I /O controller during the Command phase. During periods of the SCH5317...is in which occurs at runtime. Write 30h to 2Eh deactivates the configuration phase. 5-4 www.hp.com Technical Reference Guide The Main Status register (3F4h/374h) provides data flow control for ...Drive Interface The MT and CMT form factors support a diskette drive through a standard 34-pin diskette drive connector.
HP Compaq dx7300 and dc7700 Business PC Technical Reference Guide, 1st Edition
Page 89
... register (CTR). Address decoding includes address lines A0, A1, and A2. Technical Reference Guide www.hp.com 5-11 The system checks the Printer Status register. In extended mode, a direction control bit ...active, the system either waits for a status change or generates an error message. 2. If the Busy, Paper Out, or Printer Fault signals are possible (up to 150 KB/s. If compatible, then...-modes of operation, compatible and extended, both supported. A CPU read to fetch data present on the eight data lines. In the compatible mode, CPU write data is used . The system then...
... register (CTR). Address decoding includes address lines A0, A1, and A2. Technical Reference Guide www.hp.com 5-11 The system checks the Printer Status register. In extended mode, a direction control bit ...active, the system either waits for a status change or generates an error message. 2. If the Busy, Paper Out, or Printer Fault signals are possible (up to 150 KB/s. If compatible, then...-modes of operation, compatible and extended, both supported. A CPU read to fetch data present on the eight data lines. In the compatible mode, CPU write data is used . The system then...
HP Compaq dx7300 and dc7700 Business PC Technical Reference Guide, 1st Edition
Page 90
... Port Mode The Extended Capabilities Port (ECP) mode, like EPP, also uses a hardware protocol-based design that can be accessed by the CPU using DMA or programmed I /O controller. When configured for ECP mode, a negotiation phase is cleared and not used . Address selection and enabling...Register R/W 00h F1h Mode Register 2 R/W 00h 5-12 www.hp.com Technical Reference Guide The ECP mode includes a bi-directional FIFO buffer that supports transfers up to detect whether or not the connected peripheral is supported by software. The ECP mode includes several sub-modes as ...
... Port Mode The Extended Capabilities Port (ECP) mode, like EPP, also uses a hardware protocol-based design that can be accessed by the CPU using DMA or programmed I /O controller. When configured for ECP mode, a negotiation phase is cleared and not used . Address selection and enabling...Register R/W 00h F1h Mode Register 2 R/W 00h 5-12 www.hp.com Technical Reference Guide The ECP mode includes a bi-directional FIFO buffer that supports transfers up to detect whether or not the connected peripheral is supported by software. The ECP mode includes several sub-modes as ...
HP Compaq dx7300 and dc7700 Business PC Technical Reference Guide, 1st Edition
Page 154
... in a memory device installed in network mode. Restore default image w/flash utility. 511-CPU Fan Not Detected Processor heat sink fan is not connected. 512-Chassis Fan Not Detected Chassis... memory configuration. 219-ECC Memory Module Detected ECC Modules not supported on this platform Recently added memory module(s) support ECC memory error correction. 301-Keyboard Error Keyboard interface test .... 150-Safe POST Active An option ROM failed to enter a valid number. A-2 www.hp.com Technical Reference Guide Power-On Self Test (POST) Messages Error Message Probable Cause Invalid ...
... in a memory device installed in network mode. Restore default image w/flash utility. 511-CPU Fan Not Detected Processor heat sink fan is not connected. 512-Chassis Fan Not Detected Chassis... memory configuration. 219-ECC Memory Module Detected ECC Modules not supported on this platform Recently added memory module(s) support ECC memory error correction. 301-Keyboard Error Keyboard interface test .... 150-Safe POST Active An option ROM failed to enter a valid number. A-2 www.hp.com Technical Reference Guide Power-On Self Test (POST) Messages Error Message Probable Cause Invalid ...