Microsoft Windows Event ID and SNMP Traps Reference Guide for use with SmartStart version 8.25
Page 31
... can be caused by a corrupt registry or a low memory condition. Log Message: The Storage Agents service encountered a fatal error. This indicates a low memory condition. The ProLiant storage system %1 is terminating. Rebooting the server may correct this version of the Storage Agents. This error can be caused by a corrupt registry or a low...
... can be caused by a corrupt registry or a low memory condition. Log Message: The Storage Agents service encountered a fatal error. This indicates a low memory condition. The ProLiant storage system %1 is terminating. Rebooting the server may correct this version of the Storage Agents. This error can be caused by a corrupt registry or a low...
Microsoft Windows Event ID and SNMP Traps Reference Guide for use with SmartStart version 8.25
Page 77
... device monitor driver (CPQSDM.SYS). Always reboot the system after a Storage Agents upgrade. Rebooting the server may correct this version of the Storage Agents. The ProLiant storage system %1 is %1. This error can be caused by a corrupt registry or a low memory condition. Rebooting the server may correct this error. This error can...
... device monitor driver (CPQSDM.SYS). Always reboot the system after a Storage Agents upgrade. Rebooting the server may correct this version of the Storage Agents. The ProLiant storage system %1 is %1. This error can be caused by a corrupt registry or a low memory condition. Rebooting the server may correct this error. This error can...
HP USB Floppy Drive Key Installation Instructions
Page 1
...Under most operating systems, both USB drive key and USB floppy drive functionality. CAUTION: Do not use the drive key for HP products and services are accessible regardless of the position of the device, set the device switch to load completely... in this partition. 4. The system boots from the USB floppy partition of the device switch. HP USB Floppy Drive Key Installation Instructions Overview The USB Floppy Drive Key provides HP ProLiant server users with HP ProLiant servers running Microsoft® Windows® Server™ 2000, Microsoft® Windows Server™ ...
...Under most operating systems, both USB drive key and USB floppy drive functionality. CAUTION: Do not use the drive key for HP products and services are accessible regardless of the position of the device, set the device switch to load completely... in this partition. 4. The system boots from the USB floppy partition of the device switch. HP USB Floppy Drive Key Installation Instructions Overview The USB Floppy Drive Key provides HP ProLiant server users with HP ProLiant servers running Microsoft® Windows® Server™ 2000, Microsoft® Windows Server™ ...
ProLiant Essentials Foundation Pack Installation Guide
Page 1
... for technical or editorial errors or omissions contained herein. provides comprehensive fault, asset, and configuration management for HP ProLiant server products. IMPORTANT: The SmartStart CD is supported by assisting hardware configuration and installation of Microsoft Corporation. ORCA...warranty statements accompanying such products and services. Manual Installation using RBSU (ROM-Based Setup Utility) by booting SmartStart. HP ProLiant Essentials Foundation Pack Installation Guide © Copyright 2002, 2008 Hewlett-Packard Development Company, L.P. The only warranties for...
... for technical or editorial errors or omissions contained herein. provides comprehensive fault, asset, and configuration management for HP ProLiant server products. IMPORTANT: The SmartStart CD is supported by assisting hardware configuration and installation of Microsoft Corporation. ORCA...warranty statements accompanying such products and services. Manual Installation using RBSU (ROM-Based Setup Utility) by booting SmartStart. HP ProLiant Essentials Foundation Pack Installation Guide © Copyright 2002, 2008 Hewlett-Packard Development Company, L.P. The only warranties for...
HP BladeSystem Management Pack version 1.0 for Microsoft System Center Essentials Troubleshooting Assistant
Page 6
..., click Change, and then click Repair. If the purpose of the HP ProLiant Server Management Pack for each HP Management Pack. 5. Find the Management Packs that begin with the release notes or the HP BladeSystem Management Pack for System Center Essentials. • System Center Essentials ...if you are refreshing the environment, then from the Add or Remove Programs menu in the Control Panel after manually deleting the HP BladeSystem Management Pack from the System Center Essentials operator console. Installing the kits to a remote System Center Essentials console environment The...
..., click Change, and then click Repair. If the purpose of the HP ProLiant Server Management Pack for each HP Management Pack. 5. Find the Management Packs that begin with the release notes or the HP BladeSystem Management Pack for System Center Essentials. • System Center Essentials ...if you are refreshing the environment, then from the Add or Remove Programs menu in the Control Panel after manually deleting the HP BladeSystem Management Pack from the System Center Essentials operator console. Installing the kits to a remote System Center Essentials console environment The...
HP BladeSystem Management Pack for Microsoft System Center Essentials 2007 User Guide
Page 7
... c-Class Enclosures represented in the Diagram View • Console Tasks to launch HP Onboard Administrator, HP Enclosure Monitor Manager, and HP Integrated Lights-Out Management Processors from the System Center Essentials Console • Access to HP BladeSystem c-Class Enclosure and other HP ProLiant Essentials value-added software for hardware performance management, vulnerability assessment, and advanced lifecycle...
... c-Class Enclosures represented in the Diagram View • Console Tasks to launch HP Onboard Administrator, HP Enclosure Monitor Manager, and HP Integrated Lights-Out Management Processors from the System Center Essentials Console • Access to HP BladeSystem c-Class Enclosure and other HP ProLiant Essentials value-added software for hardware performance management, vulnerability assessment, and advanced lifecycle...
HP BladeSystem Management Pack for Microsoft System Center Essentials 2007 User Guide
Page 9
... steps of firmware are installed on the system. The HP BladeSystem Management Pack is not for use on systems running Microsoft® System Center Operations Manager 2007. • The HP ProLiant Server Management Pack 1.0 for System Center Essentials 2007 (x64...) File name Description HPBladeSystemMPforSCE1_0x Used to the System Center Essentials 2007. 5. This Installation 9 Install the HP BladeSystem Management Pack for Microsoft® System Center...
... steps of firmware are installed on the system. The HP BladeSystem Management Pack is not for use on systems running Microsoft® System Center Operations Manager 2007. • The HP ProLiant Server Management Pack 1.0 for System Center Essentials 2007 (x64...) File name Description HPBladeSystemMPforSCE1_0x Used to the System Center Essentials 2007. 5. This Installation 9 Install the HP BladeSystem Management Pack for Microsoft® System Center...
HP BladeSystem Management Pack for Microsoft System Center Essentials 2007 User Guide
Page 18
....21.79 - Part Number 412140-B21 - Class Property name Sample value - Server Name N/A HP BladeSystem Device Bay Name Device Bay 2-ProLiant Server - System Board Spare Part 410293-001 Number - BIOS Asset Tag Xxxxxxx - Redundancy Redundant ... 2 Interconnect Bays - Integrated Lights-Out Name ILOUSM62500TE - Server Name N/A HP BladeSystem Fan Name Fan-Bay1 - Blade Type Workstation - Enclosure Serial Number USE6321FJC - Bay Number 1 - Product Name ProLiant BL685c G1 - Serial Number (empty) - Enclosure Serial Number USE6321FJC - ...
....21.79 - Part Number 412140-B21 - Class Property name Sample value - Server Name N/A HP BladeSystem Device Bay Name Device Bay 2-ProLiant Server - System Board Spare Part 410293-001 Number - BIOS Asset Tag Xxxxxxx - Redundancy Redundant ... 2 Interconnect Bays - Integrated Lights-Out Name ILOUSM62500TE - Server Name N/A HP BladeSystem Fan Name Fan-Bay1 - Blade Type Workstation - Enclosure Serial Number USE6321FJC - Bay Number 1 - Product Name ProLiant BL685c G1 - Serial Number (empty) - Enclosure Serial Number USE6321FJC - ...
HP BladeSystem Management Pack for Microsoft System Center Essentials 2007 User Guide
Page 20
... Enclosures/Enclosure State-This view displays the state view by HP BladeSystem Enclosures. • HP BladeSystem Enclosures/Health Collection State-This view displays the state view by HP ProLiant Server Management Pack for viewing information stored in the HP Servers/Health Collection State view. • HP BladeSystem Enclosures/Monitor Service State-This view displays the state...
... Enclosures/Enclosure State-This view displays the state view by HP BladeSystem Enclosures. • HP BladeSystem Enclosures/Health Collection State-This view displays the state view by HP ProLiant Server Management Pack for viewing information stored in the HP Servers/Health Collection State view. • HP BladeSystem Enclosures/Monitor Service State-This view displays the state...
HP BladeSystem Management Pack for Microsoft System Center Essentials 2007 User Guide
Page 35
...the desired bay using a standard browser interface. Log in HP BladeSystem Enclosures include an Integrated Lights-Out management processor, which enables you to display information: 1. Click HP Integrated Lights-Out. Click HP Onboard Administrator. 3. Select an Enclosure or a Health Collection... Diagram view. 2. The HP BladeSystem Management Pack 1.0 for System Center Essentials 2007 includes a task that collects HP Integrated Lights-Out management processor data and creates an associated browser link to remotely access the selected HP ProLiant Blade server. Using the software...
...the desired bay using a standard browser interface. Log in HP BladeSystem Enclosures include an Integrated Lights-Out management processor, which enables you to display information: 1. Click HP Integrated Lights-Out. Click HP Onboard Administrator. 3. Select an Enclosure or a Health Collection... Diagram view. 2. The HP BladeSystem Management Pack 1.0 for System Center Essentials 2007 includes a task that collects HP Integrated Lights-Out management processor data and creates an associated browser link to remotely access the selected HP ProLiant Blade server. Using the software...
10 Gigabit Ethernet technology for industry-standard servers
Page 9
...that are eight lane (x8) PCI Express (PCIe) 10 Gigabit network solutions offering the highest bandwidth available in a ProLiant Ethernet adapter. HP Dual Port 10GbE Server Adapters The NC522SFP serve adapter and the NC524SFP Dual Port 10GbE Module are optimized for speed, ...PCI Express version 2 adapter, shown in either standard or low profile slots. Figure 4. HP offers a broad portfolio of 10GbE products for ProLiant blade, rack, and tower platforms. HP 10GbE architecture includes network designs that benefit from 10GbE bandwidth. These designs incorporate appropriate media ...
...that are eight lane (x8) PCI Express (PCIe) 10 Gigabit network solutions offering the highest bandwidth available in a ProLiant Ethernet adapter. HP Dual Port 10GbE Server Adapters The NC522SFP serve adapter and the NC524SFP Dual Port 10GbE Module are optimized for speed, ...PCI Express version 2 adapter, shown in either standard or low profile slots. Figure 4. HP offers a broad portfolio of 10GbE products for ProLiant blade, rack, and tower platforms. HP 10GbE architecture includes network designs that benefit from 10GbE bandwidth. These designs incorporate appropriate media ...
10 Gigabit Ethernet technology for industry-standard servers
Page 10
... visible on what appears to be connected to the data center environment. The NC524SFP allows customers to their HP ProLiant DL370 G6 and ProLiant ML370 G6 servers with virtual machines could fully utilize a single 10Gb NIC. HP Virtual Connect (VC) is growing rapidly. The VC Ethernet Modules allow the c-Class administrator to interconnect multiple...
... visible on what appears to be connected to the data center environment. The NC524SFP allows customers to their HP ProLiant DL370 G6 and ProLiant ML370 G6 servers with virtual machines could fully utilize a single 10Gb NIC. HP Virtual Connect (VC) is growing rapidly. The VC Ethernet Modules allow the c-Class administrator to interconnect multiple...
10 Gigabit Ethernet technology for industry-standard servers
Page 16
... data center HP ProLiant networking 10GbE network adapters HP BladeSystem 10GbE Interconnects Multifunction Networking Products HP ProCurve 10GbE support FAQ HP ProCurve 10-GbE Transceiver Support Matrix HP Flex-10 technology brief HP NC522SFP PCIe adapter HP NC524SFP PCIe adapter HP Flex-10 VC Ethernet Module HP NC532m Dual... Call to action Send comments about this paper to the resources listed below. Nothing herein should be liable for HP products and services are set forth in the express warranty statements accompanying such products and services. For more information For...
... data center HP ProLiant networking 10GbE network adapters HP BladeSystem 10GbE Interconnects Multifunction Networking Products HP ProCurve 10GbE support FAQ HP ProCurve 10-GbE Transceiver Support Matrix HP Flex-10 technology brief HP NC522SFP PCIe adapter HP NC524SFP PCIe adapter HP Flex-10 VC Ethernet Module HP NC532m Dual... Call to action Send comments about this paper to the resources listed below. Nothing herein should be liable for HP products and services are set forth in the express warranty statements accompanying such products and services. For more information For...
Booting HP ProLiant servers from a storage area network
Page 1
Booting HP ProLiant servers from a storage area network HOWTO, 2nd edition Abstract...2 Required hardware ...2 Supported firmware versions ...2 Supported Fibre Channel switches ...2 Setting up LUN on HP StorageWorks arrays and zoning on Fibre Channel switches 3 Deploying the OS by CD overview ...3 Deploying the OS by Rapid Deployment Pack overview 4 Before you start...4 Instructions ...4 Scripted installs...6 Image deployment ...6 For more information...7 Call to action ...7
Booting HP ProLiant servers from a storage area network HOWTO, 2nd edition Abstract...2 Required hardware ...2 Supported firmware versions ...2 Supported Fibre Channel switches ...2 Setting up LUN on HP StorageWorks arrays and zoning on Fibre Channel switches 3 Deploying the OS by CD overview ...3 Deploying the OS by Rapid Deployment Pack overview 4 Before you start...4 Instructions ...4 Scripted installs...6 Image deployment ...6 For more information...7 Call to action ...7
Booting HP ProLiant servers from a storage area network
Page 2
... for server and storage systems, visit the HP website at ftp://ftp.compaq.com/pub/products/servers/support/Boot_from_SAN_Fibre_Channel_Switch_Supp ort_Matrix.pdf lists which ProLiant servers are essential for Fibre Channel switch and HP StorageWorks array combination that you have the required...server replacement in the future. 2 Supported Fibre Channel switches The matrix at http://welcome.hp.com/country/us/en/support.html?jumpid=hpr_R1002_USEN. Abstract Traditionally, HP ProLiant servers boot operating systems (OSs) from SAN, points customers to eliminate serverbased internal boot ...
... for server and storage systems, visit the HP website at ftp://ftp.compaq.com/pub/products/servers/support/Boot_from_SAN_Fibre_Channel_Switch_Supp ort_Matrix.pdf lists which ProLiant servers are essential for Fibre Channel switch and HP StorageWorks array combination that you have the required...server replacement in the future. 2 Supported Fibre Channel switches The matrix at http://welcome.hp.com/country/us/en/support.html?jumpid=hpr_R1002_USEN. Abstract Traditionally, HP ProLiant servers boot operating systems (OSs) from SAN, points customers to eliminate serverbased internal boot ...
Booting HP ProLiant servers from a storage area network
Page 3
...instructions that you downloaded in Step 1. 3 Load the OS to the array. Download, but do not install, the latest HBA drivers, SmartStart, and the ProLiant Support Pack. Insert the OS CD into the Boot from SAN configurations, the boot paths must be on the active path to the boot logical...various errors. In boot from SAN host system CD-ROM drive and reboot the host system. This step completes the configuration. 6. Setting up LUN on HP StorageWorks arrays and zoning on the SAN. 5. The installation begins. Install the latest HBA drivers that appear on Fibre Channel switches: • 32-...
...instructions that you downloaded in Step 1. 3 Load the OS to the array. Download, but do not install, the latest HBA drivers, SmartStart, and the ProLiant Support Pack. Insert the OS CD into the Boot from SAN configurations, the boot paths must be on the active path to the boot logical...various errors. In boot from SAN host system CD-ROM drive and reboot the host system. This step completes the configuration. 6. Setting up LUN on HP StorageWorks arrays and zoning on the SAN. 5. The installation begins. Install the latest HBA drivers that appear on Fibre Channel switches: • 32-...
Booting HP ProLiant servers from a storage area network
Page 4
... Edition 3.00. Windows Edition Support Matrix at http://h20000.www2.hp.com/bc/docs/support/SupportManual/c01174425/c01174425.pdf?ju mpid=reg_R1002_USEN to deploy the OS using Windows Edition 1.00, you start Consult the HP ProLiant Essentials Rapid Deployment Pack - This job will create the file ...QLogic Fibre Channel Host Bus Adapter (FC HBA) that boots from an HP StorageWorks Storage Area Network (SAN). Ensure that the server has booted PXE and is installed. 2. Hardware Configuration\HBA job folder on a ProLiant BL server with RDP. Ensure that the target server is the target...
... Edition 3.00. Windows Edition Support Matrix at http://h20000.www2.hp.com/bc/docs/support/SupportManual/c01174425/c01174425.pdf?ju mpid=reg_R1002_USEN to deploy the OS using Windows Edition 1.00, you start Consult the HP ProLiant Essentials Rapid Deployment Pack - This job will create the file ...QLogic Fibre Channel Host Bus Adapter (FC HBA) that boots from an HP StorageWorks Storage Area Network (SAN). Ensure that the server has booted PXE and is installed. 2. Hardware Configuration\HBA job folder on a ProLiant BL server with RDP. Ensure that the target server is the target...
Booting HP ProLiant servers from a storage area network
Page 5
... Storage Presentation as needed in the link description as the first visible LUN. Notice the WWID of jobs from Step 3. Execute the Deploy ProLiant BL System Configuration (Boot From SAN) job from the Server Deployment Toolbox\1 - For Linux Edition, click on the target server, select ...and then look for the ID field. In the browser status bar, the computer's ID is shown in your environment. 6. Execute the Write ProLiant ML/DL/BL QLogic HBA Configuration [server specific] job from the Server Deployment Toolbox\1 - Hardware Configuration\System job folder on the target server....
... Storage Presentation as needed in the link description as the first visible LUN. Notice the WWID of jobs from Step 3. Execute the Deploy ProLiant BL System Configuration (Boot From SAN) job from the Server Deployment Toolbox\1 - For Linux Edition, click on the target server, select ...and then look for the ID field. In the browser status bar, the computer's ID is shown in your environment. 6. Execute the Write ProLiant ML/DL/BL QLogic HBA Configuration [server specific] job from the Server Deployment Toolbox\1 - Hardware Configuration\System job folder on the target server....
Booting HP ProLiant servers from a storage area network
Page 7
...without notice. The only warranties for Optimal Performance and Functionality of HP ProLiant Servers http://h20000.www2.hp.com/bc/docs/support/SupportM anual/c00403562/c00403562.pdf http://h20000.www2.hp.com/bc/docs/support/SupportM anual/c00264524/c00264524.pdf Call to action... be liable for technical or editorial errors or omissions contained herein. TC070303HT, 3/2007 Source Hyperlink HP StorageWorks SAN Design Reference Guide Regular Firmware Updates Essential for HP products and services are set forth in the express warranty statements accompanying such products and services....
...without notice. The only warranties for Optimal Performance and Functionality of HP ProLiant Servers http://h20000.www2.hp.com/bc/docs/support/SupportM anual/c00403562/c00403562.pdf http://h20000.www2.hp.com/bc/docs/support/SupportM anual/c00264524/c00264524.pdf Call to action... be liable for technical or editorial errors or omissions contained herein. TC070303HT, 3/2007 Source Hyperlink HP StorageWorks SAN Design Reference Guide Regular Firmware Updates Essential for HP products and services are set forth in the express warranty statements accompanying such products and services....
Citrix XenDesktop architecture and implementation on ProLiant servers
Page 1
Citrix XenDesktop Architecture and Implementation on ProLiant Servers integration note Abstract...2 What is Citrix XenDesktop?...2 Virtual Desktops ...2 Why use the HP integrated XenServer 4 HP ProLiant Virtual Console ...4 Faster provisioning ...6 Versions of XenDesktop available from HP 6 The HP XenDesktop solution ...8 Hardware requirements for XenDesktop 2.1 8 Setup and deployment ...8 HP thin clients...10 Why use HP thin clients?...11 Why not reutilize existing devices 11 For more information...13 Call to action ...13
Citrix XenDesktop Architecture and Implementation on ProLiant Servers integration note Abstract...2 What is Citrix XenDesktop?...2 Virtual Desktops ...2 Why use the HP integrated XenServer 4 HP ProLiant Virtual Console ...4 Faster provisioning ...6 Versions of XenDesktop available from HP 6 The HP XenDesktop solution ...8 Hardware requirements for XenDesktop 2.1 8 Setup and deployment ...8 HP thin clients...10 Why use HP thin clients?...11 Why not reutilize existing devices 11 For more information...13 Call to action ...13