Models: AQ-TROL-HP AQ-TROL-HP-TL AQ-TROL-RJ and AQ-TROL-RJ-TL
Page 1
Aqua Trol® Above Ground Pool Chlorine Generator Operation and Installation Manual AQ-TROL-RJ AQ-TROL-RJ-TL AQ-TROL-HP AQ-TROL-HP-TL www.haywardnet.com
Aqua Trol® Above Ground Pool Chlorine Generator Operation and Installation Manual AQ-TROL-RJ AQ-TROL-RJ-TL AQ-TROL-HP AQ-TROL-HP-TL www.haywardnet.com
Models: AQ-TROL-HP AQ-TROL-HP-TL AQ-TROL-RJ and AQ-TROL-RJ-TL
Page 3
INSTALLATION Mounting 9 Plumbing 10 Wiring 11 TROUBLESHOOTING Troubleshooting 13 WARRANTY Warranty 15 Table of Contents OPERATION The Aqua Trol 1 Water Chemistry 1 Controls 6 Maintenance 8 .
INSTALLATION Mounting 9 Plumbing 10 Wiring 11 TROUBLESHOOTING Troubleshooting 13 WARRANTY Warranty 15 Table of Contents OPERATION The Aqua Trol 1 Water Chemistry 1 Controls 6 Maintenance 8 .
Models: AQ-TROL-HP AQ-TROL-HP-TL AQ-TROL-RJ and AQ-TROL-RJ-TL
Page 4
... electrical connections may be made via 120V/15A "straight blade" linecord and receptacle (standard Aqua Trol version, no option designation) or may be consulted regarding the appropriate type, installation, sealant (if any) and maintenance of up to backwashing, draining, or splashing (not... called electrolysis. adapters for return jet mounting NOTE: Before installing this product as part of a saline water purification system in an above ground pools. The Aqua Trol automatically sanitizes your pool. The Aqua Trol is available with fresh water. The actual amount of chlorination...
... electrical connections may be made via 120V/15A "straight blade" linecord and receptacle (standard Aqua Trol version, no option designation) or may be consulted regarding the appropriate type, installation, sealant (if any) and maintenance of up to backwashing, draining, or splashing (not... called electrolysis. adapters for return jet mounting NOTE: Before installing this product as part of a saline water purification system in an above ground pools. The Aqua Trol automatically sanitizes your pool. The Aqua Trol is available with fresh water. The actual amount of chlorination...
Models: AQ-TROL-HP AQ-TROL-HP-TL AQ-TROL-RJ and AQ-TROL-RJ-TL
Page 12
...pool does not have new water, add 1 quart (1 liter) of metal remover and 1 quart (1 liter) of the control. Mounting the Aqua Trol Control The Aqua Trol is contained in a raintight enclosure that is suitable for recommended chemical levels. The pool's chemistry must be mounted a minimum of 5 ft. ...(2 meters) horizontal distance (or more if local codes require) from inside the box), it is designed to the Aqua Trol system. Because the enclosure also acts as a heat sink (disperses heat from the pool. Installation Installation must be performed in a panel or tight enclosed area.
...pool does not have new water, add 1 quart (1 liter) of metal remover and 1 quart (1 liter) of the control. Mounting the Aqua Trol Control The Aqua Trol is contained in a raintight enclosure that is suitable for recommended chemical levels. The pool's chemistry must be mounted a minimum of 5 ft. ...(2 meters) horizontal distance (or more if local codes require) from inside the box), it is designed to the Aqua Trol system. Because the enclosure also acts as a heat sink (disperses heat from the pool. Installation Installation must be performed in a panel or tight enclosed area.
Models: AQ-TROL-HP AQ-TROL-HP-TL AQ-TROL-RJ and AQ-TROL-RJ-TL
Page 13
...jet fitting and, in its place, screw in the right-angle cell mounting adaptor. The kit included in the Aqua Trol provides the necessary plumbing components for detail on the return jet mounting. Install after (downstream) all union nuts BY HAND for a watertight seal. Always make sure that the cell be ...coming from the cell. Attach the cell to the union and then use the fittings supplied to attach the lower end of the Aqua Trol system with the hose/pipe installation (HP) is downstream from the pools filtration system. Plumbing The cell and flow switch (not used on -RJ systems) are plumbed...
...jet fitting and, in its place, screw in the right-angle cell mounting adaptor. The kit included in the Aqua Trol provides the necessary plumbing components for detail on the return jet mounting. Install after (downstream) all union nuts BY HAND for a watertight seal. Always make sure that the cell be ...coming from the cell. Attach the cell to the union and then use the fittings supplied to attach the lower end of the Aqua Trol system with the hose/pipe installation (HP) is downstream from the pools filtration system. Plumbing The cell and flow switch (not used on -RJ systems) are plumbed...
Models: AQ-TROL-HP AQ-TROL-HP-TL AQ-TROL-RJ and AQ-TROL-RJ-TL
Page 14
Twist lock models should be plugged into typical above ground pool systems. To provide safe operation, the Aqua Trol must be shut off at the circuit breaker before performing any wiring. Input Power Models with the standard 120 ... NEUTRAL GROUND SUBPANEL GFCI OUTLET Aqua Trol AQUA TROL (AQ-TROL-XX) BONDING LOOP PUMP GFCI CIRCUIT BREAKER TWIST-LOCK PLUGS (L520) Aqua Trol NEUTRAL GROUND SUBPANEL TWIST-LOCK OUTLET (L520) AQUA TROL (AQ-TROL-XX-TL) BONDING LOOP PUMP 11 For Canadian installations: Connect to a GFCI circuit breaker. The Aqua Trol has been designed to follow ...
Twist lock models should be plugged into typical above ground pool systems. To provide safe operation, the Aqua Trol must be shut off at the circuit breaker before performing any wiring. Input Power Models with the standard 120 ... NEUTRAL GROUND SUBPANEL GFCI OUTLET Aqua Trol AQUA TROL (AQ-TROL-XX) BONDING LOOP PUMP GFCI CIRCUIT BREAKER TWIST-LOCK PLUGS (L520) Aqua Trol NEUTRAL GROUND SUBPANEL TWIST-LOCK OUTLET (L520) AQUA TROL (AQ-TROL-XX-TL) BONDING LOOP PUMP 11 For Canadian installations: Connect to a GFCI circuit breaker. The Aqua Trol has been designed to follow ...
Models: AQ-TROL-HP AQ-TROL-HP-TL AQ-TROL-RJ and AQ-TROL-RJ-TL
Page 18
...AFTER LEAVING THE FACTORY. Hayward/Goldline also warrants its Aqua Rite, Aqua Rite Pro, Aqua Plus and SwimPure chlorination products to be free of defects in materials and workmanship, under normal use and service, for a period of three (3) years. Proof of installation on swimming pools outside... Hayward/Goldline warrants its Pro Logic and E-Command pool automation products as well as its Aqua Trol chlorination products to be free of defects in materials and workmanship, under normal use and service for a period of one (1) year. These warranties are applicable from failure to install,...
...AFTER LEAVING THE FACTORY. Hayward/Goldline also warrants its Aqua Rite, Aqua Rite Pro, Aqua Plus and SwimPure chlorination products to be free of defects in materials and workmanship, under normal use and service, for a period of three (3) years. Proof of installation on swimming pools outside... Hayward/Goldline warrants its Pro Logic and E-Command pool automation products as well as its Aqua Trol chlorination products to be free of defects in materials and workmanship, under normal use and service for a period of one (1) year. These warranties are applicable from failure to install,...