GIGA -BYTE TECHNOLOGY CO., LTD. [3] Open Windows IE and connect to target system BMC Web UI for logon to system. [4] Power off the target system [5] Update BIOS (1.) Select Update page (2.) Select Firmware Type to "BIOS & ME" (3.) Select File Path of "image.RBU" (4.) Click Upload button
GIGA -BYTE TECHNOLOGY CO., LTD. [3] Open Windows IE and connect to target system BMC Web UI for logon to system. [4] Power off the target system [5] Update BIOS (1.) Select Update page (2.) Select Firmware Type to "BIOS & ME" (3.) Select File Path of "image.RBU" (4.) Click Upload button
Manual
Page 6
Tftpd64.exe/Tftpd32.exe through BMC Command-line interface 2.1. BMC command format table Update BIOS through free download). [5] Setup TFTP server for Windows client PC (e.g. Preparation [1] Get BIOS image file "image.RBU" of target system. [2] Make sure target system BMC is live. [3] Get BMC IP address of target system. [4] Download TFTP service application for Linux client PC (Please users set up their own TFTP server.). [6] Get ipmitool. 2.2. GIGA -BYTE TECHNOLOGY CO., LTD. 2.
Tftpd64.exe/Tftpd32.exe through BMC Command-line interface 2.1. BMC command format table Update BIOS through free download). [5] Setup TFTP server for Windows client PC (e.g. Preparation [1] Get BIOS image file "image.RBU" of target system. [2] Make sure target system BMC is live. [3] Get BMC IP address of target system. [4] Download TFTP service application for Linux client PC (Please users set up their own TFTP server.). [6] Get ipmitool. 2.2. GIGA -BYTE TECHNOLOGY CO., LTD. 2.
Manual
Page 8
ipmitool -H 10.1.27.150 -U admin -P password raw 0x06 0x01 Update BIOS (Sample on Windows client PC) [1] Set up TFTP service application Execute Tftpd64.exe Set Current Directory to file path of "image.RBU" GIGA -BYTE TECHNOLOGY CO., LTD. [2] Execute cmd.exe and connect to check connect BMC is success or not. Use command 0x06 0x01 to target system BMC through ipmitool. e.g. 2.3.
ipmitool -H 10.1.27.150 -U admin -P password raw 0x06 0x01 Update BIOS (Sample on Windows client PC) [1] Set up TFTP service application Execute Tftpd64.exe Set Current Directory to file path of "image.RBU" GIGA -BYTE TECHNOLOGY CO., LTD. [2] Execute cmd.exe and connect to check connect BMC is success or not. Use command 0x06 0x01 to target system BMC through ipmitool. e.g. 2.3.
Manual
Page 10
... upload status e.g. ipmitool -H 10.1.27.150 -U admin -P password raw 0x2e 0x21 0x0a 0x3c 0x00 0x0e Response: 0a 3c 00 01 00 Byte 1 = 00h : Command Completed Normally Byte 2 = 01h : Copying To Scratch Byte 3 = 00h : Update Progress (If byte 2 is 06, this data is available.) e.g. GIGA -BYTE TECHNOLOGY CO., LTD. [4] Upload "image.RBU" through TFTP service application.
... upload status e.g. ipmitool -H 10.1.27.150 -U admin -P password raw 0x2e 0x21 0x0a 0x3c 0x00 0x0e Response: 0a 3c 00 01 00 Byte 1 = 00h : Command Completed Normally Byte 2 = 01h : Copying To Scratch Byte 3 = 00h : Update Progress (If byte 2 is 06, this data is available.) e.g. GIGA -BYTE TECHNOLOGY CO., LTD. [4] Upload "image.RBU" through TFTP service application.
Manual
Page 2
... 4 Software Install ...5 Prerequisites on remote management PC 5 Install Java Tool ...5 Gigabyte Content Management Network Configuration 6 Using the Web UI...8 Gigabyte Content Management System Console Overview 9 Enter Gigabyte Content Management System Console 10 Properties ...10 Configuration ...11 Network...11 Network Security ...12 Security ...13 Users ...14 Services ...15 IPMI ...16 Time Setting ...18 Language ...19 Sessions ...20 LDAP ...21 Updates ...22 Utilities ...23 Server Information ...24 General Setting...24 Power Control ...25 Power...
... 4 Software Install ...5 Prerequisites on remote management PC 5 Install Java Tool ...5 Gigabyte Content Management Network Configuration 6 Using the Web UI...8 Gigabyte Content Management System Console Overview 9 Enter Gigabyte Content Management System Console 10 Properties ...10 Configuration ...11 Network...11 Network Security ...12 Security ...13 Users ...14 Services ...15 IPMI ...16 Time Setting ...18 Language ...19 Sessions ...20 LDAP ...21 Updates ...22 Utilities ...23 Server Information ...24 General Setting...24 Power Control ...25 Power...
Manual
Page 5
... LAN. FRU information report includes main board part number, product name, and manufacturer, etc.) Health status/Hardware monitoring report. Events log, view, and clear. Event notification via PET (Platform Event Trap). Platform Event Filtering (PEF) to take selected action for selected events. Chassis management includes power control and status report, front panel buttons and LEDs control. Support...
... LAN. FRU information report includes main board part number, product name, and manufacturer, etc.) Health status/Hardware monitoring report. Events log, view, and clear. Event notification via PET (Platform Event Trap). Platform Event Filtering (PEF) to take selected action for selected events. Chassis management includes power control and status report, front panel buttons and LEDs control. Support...
Manual
Page 6
... following required configuration requirements: Supported Browsers: Internet Explorer 8~12 Google chrome Version 29.0.1547.66m Firefox 2.0 JAVA Recommended Version 8 Update 25 or later version (file size: ~ 623KB) Install Java Tool Please follow the instruction to replace. 9. Close all Java downloads 5. Go to start the installation process. 5 Select the operating system you are using. 6. Click Yes to install Java in Windows operating system...
... following required configuration requirements: Supported Browsers: Internet Explorer 8~12 Google chrome Version 29.0.1547.66m Firefox 2.0 JAVA Recommended Version 8 Update 25 or later version (file size: ~ 623KB) Install Java Tool Please follow the instruction to replace. 9. Close all Java downloads 5. Go to start the installation process. 5 Select the operating system you are using. 6. Click Yes to install Java in Windows operating system...
Manual
Page 7
Select BMC network Configuration 4. Define Configuration Address source to BIOS setup menu. 2. The BMC IP Address will appear on the IPv4 Address parameter. 6 Save and Exit. 6. Go to DynamicBmcDhcp or Static. 5. Select Server Management. 3. Gigabyte Content Management Network Configuration Please follow the instruction to enable the console redirection function. 1.
Select BMC network Configuration 4. Define Configuration Address source to BIOS setup menu. 2. The BMC IP Address will appear on the IPv4 Address parameter. 6 Save and Exit. 6. Go to DynamicBmcDhcp or Static. 5. Select Server Management. 3. Gigabyte Content Management Network Configuration Please follow the instruction to enable the console redirection function. 1.
Manual
Page 10
... Password: superuser The default user name and password are in , you to enter Username and Password. 3. Gigabyte Content Management System Console Overview 1. The IP address can be found using the root user name and password, you have full administrative powers. It is Intel C20x series chipset, please enter the following values: Username: admin Password: password If your motherboard is advised that once you log in lower-case characters...
... Password: superuser The default user name and password are in , you to enter Username and Password. 3. Gigabyte Content Management System Console Overview 1. The IP address can be found using the root user name and password, you have full administrative powers. It is Intel C20x series chipset, please enter the following values: Username: admin Password: password If your motherboard is advised that once you log in lower-case characters...
Manual
Page 12
... the network settings on this screen. Dedicate Mode When set to Shared Mode, you can configure the BMC related settings through the BMC port. 2. Failover Mode When set to Dedicate Mode, you can configure the BMC related settings through the BMC or NIC2 port. (Backup Mode) When you finish configuration, click Apply Change. Shared Mode When set to take effect of changes. 11 Select the Network Mode from the drop-down list. 1. Configuration Network You can configure...
... the network settings on this screen. Dedicate Mode When set to Shared Mode, you can configure the BMC related settings through the BMC port. 2. Failover Mode When set to Dedicate Mode, you can configure the BMC related settings through the BMC or NIC2 port. (Backup Mode) When you finish configuration, click Apply Change. Shared Mode When set to take effect of changes. 11 Select the Network Mode from the drop-down list. 1. Configuration Network You can configure...
Manual
Page 17
.... IPMI Serial There are allowed, including configuration commands. The Connection Mode Settings allows user to select the Console redirection type and to disable individual channels, or change the behavior of the out-of-band interfaces. Privilege levels tell the BMC which commands are allowed, except for configuration commands that the Administrator is set, select the Baud Rate and Flow Control from a remote location. For...
.... IPMI Serial There are allowed, including configuration commands. The Connection Mode Settings allows user to select the Console redirection type and to disable individual channels, or change the behavior of the out-of-band interfaces. Privilege levels tell the BMC which commands are allowed, except for configuration commands that the Administrator is set, select the Baud Rate and Flow Control from a remote location. For...
Manual
Page 18
When you finish the configuration, click "Apply Changes". 17 To activate IPMI remote configuration by LAN, check Enable IPMI Over LAN option, define the Channel Privilege Level Limit, and enter the Encryption Key. IPMI Settings IPMI Settings provides remote configuration over LAN.
When you finish the configuration, click "Apply Changes". 17 To activate IPMI remote configuration by LAN, check Enable IPMI Over LAN option, define the Channel Privilege Level Limit, and enter the Encryption Key. IPMI Settings IPMI Settings provides remote configuration over LAN.
Manual
Page 19
.... Select Slew mode when you can modify configuration settings and click the Apply Changes button to execute the settings, as well as click the Sync Time Now button (when in Requested Mode) to aggressively change the time using settimeofday() system call. 18 Time Synchronization Method Specifies the synchronization method for Requested Mode. request will be specified to configure the Network Time acquisition method...
.... Select Slew mode when you can modify configuration settings and click the Apply Changes button to execute the settings, as well as click the Sync Time Now button (when in Requested Mode) to aggressively change the time using settimeofday() system call. 18 Time Synchronization Method Specifies the synchronization method for Requested Mode. request will be specified to configure the Network Time acquisition method...
Manual
Page 25
Click Refresh to update current health status for Voltage, Power Supplies, Fans and Temperatures. 24 Server Information General Setting This page displays a real-time record of the system health related information such as Voltage, Power Supplies, Fans and Temperatures. Define Auto Refresh Interval and Sensor Type form the drop-down list, and select Display Type.
Click Refresh to update current health status for Voltage, Power Supplies, Fans and Temperatures. 24 Server Information General Setting This page displays a real-time record of the system health related information such as Voltage, Power Supplies, Fans and Temperatures. Define Auto Refresh Interval and Sensor Type form the drop-down list, and select Display Type.
Manual
Page 3
... 1-5-4 pgadminIII Installation Procedure (Optional 15 1-5-5 Login Gigabyte Server Management Console 16 Chapter 2 Gigabyte Server Management Console 17 2-1 Overview...17 2-2 Enter Gigabyte Server Management Console 18 2-2-1 Node Info...18 2-2-1-1 Node ID...20 Power Consumption...20 SEL ...21 Node Detail...21 Chassis ...22 Sensor ...23 Trap IP Destination List...24 Platform Events...25 BMC Update...26 BIOS Update...26 Power Limit...27 IP Configuration...27 CPU Utilization...27...
... 1-5-4 pgadminIII Installation Procedure (Optional 15 1-5-5 Login Gigabyte Server Management Console 16 Chapter 2 Gigabyte Server Management Console 17 2-1 Overview...17 2-2 Enter Gigabyte Server Management Console 18 2-2-1 Node Info...18 2-2-1-1 Node ID...20 Power Consumption...20 SEL ...21 Node Detail...21 Chassis ...22 Sensor ...23 Trap IP Destination List...24 Platform Events...25 BMC Update...26 BIOS Update...26 Power Limit...27 IP Configuration...27 CPU Utilization...27...
Manual
Page 5
... required configuration requirements: • System Processor: 2 GHz and above • System Memory: Minimum 4 GB RAM • Free Disk Space: 1000 GB at least • Node servers : 255 maximum 1-3 Software Requirement 1-3-1 Prerequisites on remote management server Supported Browsers: • Internet Explorer 9 or later • Google Chrome 39.0.2171.65 m or later • Mozilla Firefox 33.1.1 Operating System: • Windows 2008...
... required configuration requirements: • System Processor: 2 GHz and above • System Memory: Minimum 4 GB RAM • Free Disk Space: 1000 GB at least • Node servers : 255 maximum 1-3 Software Requirement 1-3-1 Prerequisites on remote management server Supported Browsers: • Internet Explorer 9 or later • Google Chrome 39.0.2171.65 m or later • Mozilla Firefox 33.1.1 Operating System: • Windows 2008...
Manual
Page 16
... localhost 2. Enter Database User Name postgres • This utility supported CentOS 6.3 or later version. • PostgreSQL must be execute in root authority. • In Fedora 19, you have to install package in the following: Locate and edit your distributions .repo file, located: vi /etc/yum.repos.d/fedora.repo and /etc/yum.repos.d/fedora-updates.repo ([fedora] sections) Install PGDG RPM file: curl...
... localhost 2. Enter Database User Name postgres • This utility supported CentOS 6.3 or later version. • PostgreSQL must be execute in root authority. • In Fedora 19, you have to install package in the following: Locate and edit your distributions .repo file, located: vi /etc/yum.repos.d/fedora.repo and /etc/yum.repos.d/fedora-updates.repo ([fedora] sections) Install PGDG RPM file: curl...
Manual
Page 31
... LIST. Click Refresh to clear current group SEL. Click on system. When you finish the configuration, click ON to power on selected ID to power on /off/cycle and hard reset the remote host system. Gigabyte Server Management Console Displays the grouped Node FRU information. Set Chassis Identify: Define timeout to view the Node health information. Click Refresh to update current system power control...
... LIST. Click Refresh to clear current group SEL. Click on system. When you finish the configuration, click ON to power on selected ID to power on /off/cycle and hard reset the remote host system. Gigabyte Server Management Console Displays the grouped Node FRU information. Set Chassis Identify: Define timeout to view the Node health information. Click Refresh to update current system power control...
Manual
Page 32
... sensor displays different color to indicate the health status of node power consumption/fan speed/temperature. IPv6 has a significantly larger address space than IPv4. To update the Trap IP Destination List, click Refresh. To configure Trap IPv4/IPv6 Denstination, check Enable box, enter IP address and click Modify. A platform event filter (PEF) can also choose to the new version of BMC firmware update...
... sensor displays different color to indicate the health status of node power consumption/fan speed/temperature. IPv6 has a significantly larger address space than IPv4. To update the Trap IP Destination List, click Refresh. To configure Trap IPv4/IPv6 Denstination, check Enable box, enter IP address and click Modify. A platform event filter (PEF) can also choose to the new version of BMC firmware update...
Manual
Page 38
... catalina file fail Close file channel fail Get power status fail Send chassis command fail Set IPv6 enable/disable configuration fail Get power reading fail Get CPU temperature fail Set boot option fail Set chassis identify fail Power limit deactivate Description Network is not connected or BMC is busy. Network is not connected or BMC is busy. Network is not connected or BMC is busy. Network is not connected or BMC is busy. Network is not connected or...
... catalina file fail Close file channel fail Get power status fail Send chassis command fail Set IPv6 enable/disable configuration fail Get power reading fail Get CPU temperature fail Set boot option fail Set chassis identify fail Power limit deactivate Description Network is not connected or BMC is busy. Network is not connected or BMC is busy. Network is not connected or BMC is busy. Network is not connected or BMC is busy. Network is not connected or...