Instruction Manual
Page 3
iii Contents Preface 1 Conventions used in this document 1 Safety terms and symbols 1 Product overview 2 Website activation of new and replacement modules 2 Enrolling the module 3 Module address 3 Installation 4 Mounting 4 Wiring 5 Module LEDs 6 Programming 8 Programming data 9 Location 0, programming the mode 10 Location 1, feature selection 10 Location 2, events to report to central station 11 Location 3, special events to ...
iii Contents Preface 1 Conventions used in this document 1 Safety terms and symbols 1 Product overview 2 Website activation of new and replacement modules 2 Enrolling the module 3 Module address 3 Installation 4 Mounting 4 Wiring 5 Module LEDs 6 Programming 8 Programming data 9 Location 0, programming the mode 10 Location 1, feature selection 10 Location 2, events to report to central station 11 Location 3, special events to ...
Instruction Manual
Page 6
... the NetworX series of control panels to GSM cellular networks for event reporting. The module has 14 LEDs to a minimum. The module can activate and manage the module via our website address: www.gesecurity.com/GSM (Figure 1). Website activation of new and replacement modules You can be reported, keeping airtime to provide extensive diagnostic and setup information. 2 NX-591E-GSM SMSXpress Module Installation...
... the NetworX series of control panels to GSM cellular networks for event reporting. The module has 14 LEDs to a minimum. The module can activate and manage the module via our website address: www.gesecurity.com/GSM (Figure 1). Website activation of new and replacement modules You can be reported, keeping airtime to provide extensive diagnostic and setup information. 2 NX-591E-GSM SMSXpress Module Installation...
Instruction Manual
Page 7
...keypads, zone expanders, wireless receivers, and any other device on the front of the unit), and the serial number of the NX control panel using the LCD keypad, the "Service Required" message will activate the GSM module (NX-591E-GSM). At the bottom of 76. Once a module is required. ... devices, enter program mode of the module to configure the reporting for the Method 1 that is replacing an existing cellemetry module. The serial number must contain 10 digits. 3 You must have a dealer account set up before you have just activated. • Add the account name...
...keypads, zone expanders, wireless receivers, and any other device on the front of the unit), and the serial number of the NX control panel using the LCD keypad, the "Service Required" message will activate the GSM module (NX-591E-GSM). At the bottom of 76. Once a module is required. ... devices, enter program mode of the module to configure the reporting for the Method 1 that is replacing an existing cellemetry module. The serial number must contain 10 digits. 3 You must have a dealer account set up before you have just activated. • Add the account name...
Instruction Manual
Page 15
... 3 options Segment Description 1 Alarm restores 2 Telephone fault Segment 3 4 Description Start download Fail to communicate, data lost Sensor low battery Expander trouble Failure to communicate Zone activity monitor Reserved for this location to 8 are reserved for segments 2 and 4. This location selects the partitions to include when reporting special events to the central...
... 3 options Segment Description 1 Alarm restores 2 Telephone fault Segment 3 4 Description Start download Fail to communicate, data lost Sensor low battery Expander trouble Failure to communicate Zone activity monitor Reserved for this location to 8 are reserved for segments 2 and 4. This location selects the partitions to include when reporting special events to the central...
Instruction Manual
Page 16
12 NX-591E-GSM SMSXpress Module Installation Manual Location 4, events to report to e-mail. Table 9. This location selects the partitions to include when reporting special events to e-mail Phone fault detected. ... Sensor low battery Expander trouble Failure to that particular partition number. To exclude any partition from reporting, turn off the LED corresponding to communicate Zone activity monitor Reserved for each type of report found in segments 1 through 16. Location 5, special events to report to include for future use . Table 10 describes...
12 NX-591E-GSM SMSXpress Module Installation Manual Location 4, events to report to e-mail. Table 9. This location selects the partitions to include when reporting special events to e-mail Phone fault detected. ... Sensor low battery Expander trouble Failure to that particular partition number. To exclude any partition from reporting, turn off the LED corresponding to communicate Zone activity monitor Reserved for each type of report found in segments 1 through 16. Location 5, special events to report to include for future use . Table 10 describes...
Instruction Manual
Page 17
... 15 16 Description Tampers Short circuit and ground fault Sensor lost To exclude any partition from reporting, turn off the LED corresponding to communicate Zone activity monitor Reserved for all partitions off the LED corresponding to that particular partition number. This location selects the partitions to include when reporting special events...
... 15 16 Description Tampers Short circuit and ground fault Sensor lost To exclude any partition from reporting, turn off the LED corresponding to communicate Zone activity monitor Reserved for all partitions off the LED corresponding to that particular partition number. This location selects the partitions to include when reporting special events...
Instruction Manual
Page 18
... Segment 3 4 Description Start download Fail to communicate, data lost Sensor low battery Expander trouble Failure to communicate Zone activity monitor Reserved for each type of report found in segments 1 through 4. 14 NX-591E-GSM SMSXpress Module Installation Manual Location 8, events to report to central station Phone line is good. To exclude any partition from reporting...
... Segment 3 4 Description Start download Fail to communicate, data lost Sensor low battery Expander trouble Failure to communicate Zone activity monitor Reserved for each type of report found in segments 1 through 4. 14 NX-591E-GSM SMSXpress Module Installation Manual Location 8, events to report to central station Phone line is good. To exclude any partition from reporting...
Instruction Manual
Page 19
... options Segment 1 2 Description Alarm restores Telephone fault Segment 3 4 Description Start download Fail to communicate, data lost Sensor low battery Expander trouble Failure to communicate Zone activity monitor Reserved for this location to include for each type of report found in the control panel for future use . Enter the numbers of the...
... options Segment 1 2 Description Alarm restores Telephone fault Segment 3 4 Description Start download Fail to communicate, data lost Sensor low battery Expander trouble Failure to communicate Zone activity monitor Reserved for this location to include for each type of report found in the control panel for future use . Enter the numbers of the...
Instruction Manual
Page 20
...Tampers Short circuit and ground fault Sensor lost This location has 8 segments. Table 18. Location 13, special events to report to communicate Zone activity monitor Reserved for each type of report found in segments 1 through 16. To exclude any partition from reporting, turn off the LED corresponding to... all partitions off . Table 17 describes the segment options. for all segments. Factory default is all partitions off for all segments. 16 NX-591E-GSM SMSXpress Module Installation Manual Location 12, events to report to function. This location has 16 segments.
...Tampers Short circuit and ground fault Sensor lost This location has 8 segments. Table 18. Location 13, special events to report to communicate Zone activity monitor Reserved for each type of report found in segments 1 through 16. To exclude any partition from reporting, turn off the LED corresponding to... all partitions off . Table 17 describes the segment options. for all segments. Factory default is all partitions off for all segments. 16 NX-591E-GSM SMSXpress Module Installation Manual Location 12, events to report to function. This location has 16 segments.
Instruction Manual
Page 22
... fault 3 Start download 4 Fail to communicate, data lost 12 Sensor low battery 13 Expander trouble 14 Fail to 8 Reserved for future use . 18 NX-591E-GSM SMSXpress Module Installation Manual Location 2, Reporting events to central station (Phone line fault detected) Table 21. Location 2 worksheet Partition Segment 1 2 3 4 5 6 ... full 9 Tampers 10 Short circuit and ground fault 11 Sensor lost 5 to communicate 15 Zone activity monitor 16 Reserved for future use . Location 3, Reporting special events to central station (Phone line fault detected) Table 20.
... fault 3 Start download 4 Fail to communicate, data lost 12 Sensor low battery 13 Expander trouble 14 Fail to 8 Reserved for future use . 18 NX-591E-GSM SMSXpress Module Installation Manual Location 2, Reporting events to central station (Phone line fault detected) Table 21. Location 2 worksheet Partition Segment 1 2 3 4 5 6 ... full 9 Tampers 10 Short circuit and ground fault 11 Sensor lost 5 to communicate 15 Zone activity monitor 16 Reserved for future use . Location 3, Reporting special events to central station (Phone line fault detected) Table 20.
Instruction Manual
Page 23
...) 6 Siren and telephone fault 7 Test reports 8 Program, download, and log full 9 Tampers 10 Short circuit and ground fault 11 Sensor lost 5 to communicate 15 Zone activity monitor 16 Reserved for future use . 19 Location 4, Reporting events to e-mail (Phone line fault detected) Table 23. Location 5, Reporting special events to e-mail (Phone...
...) 6 Siren and telephone fault 7 Test reports 8 Program, download, and log full 9 Tampers 10 Short circuit and ground fault 11 Sensor lost 5 to communicate 15 Zone activity monitor 16 Reserved for future use . 19 Location 4, Reporting events to e-mail (Phone line fault detected) Table 23. Location 5, Reporting special events to e-mail (Phone...
Instruction Manual
Page 24
... 7 Test reports 8 Program, download, and log full 9 Tampers 10 Short circuit and ground fault 11 Sensor lost 5 to communicate 15 Zone activity monitor 16 Reserved for future use . 20 NX-591E-GSM SMSXpress Module Installation Manual Location 6, Reporting events to pager (Phone line fault detected) Table 25. Location 7, Reporting special events to pager (Phone line...
... 7 Test reports 8 Program, download, and log full 9 Tampers 10 Short circuit and ground fault 11 Sensor lost 5 to communicate 15 Zone activity monitor 16 Reserved for future use . 20 NX-591E-GSM SMSXpress Module Installation Manual Location 6, Reporting events to pager (Phone line fault detected) Table 25. Location 7, Reporting special events to pager (Phone line...
Instruction Manual
Page 25
...) 6 Siren and telephone fault 7 Test reports 8 Program, download, and log full 9 Tampers 10 Short circuit and ground fault 11 Sensor lost 5 to communicate 15 Zone activity monitor 16 Reserved for future use . Location 9, Reporting special events to central station (Phone line is good) Table 27. 21 Location 8, Reporting events to central...
...) 6 Siren and telephone fault 7 Test reports 8 Program, download, and log full 9 Tampers 10 Short circuit and ground fault 11 Sensor lost 5 to communicate 15 Zone activity monitor 16 Reserved for future use . Location 9, Reporting special events to central station (Phone line is good) Table 27. 21 Location 8, Reporting events to central...
Instruction Manual
Page 26
22 NX-591E-GSM SMSXpress Module Installation Manual Location 10, Reporting events to e-mail (Phone line is good) Table 28. Location 11 worksheet Partition Segment 1 2 3 4 5 6 7 8 Description 1 Alarm restores 2 Telephone fault 3 Start ...) 6 Siren and telephone fault 7 Test reports 8 Program, download, and log full 9 Tampers 10 Short circuit and ground fault 11 Sensor lost 5 to communicate 15 Zone activity monitor 16 Reserved for future use .
22 NX-591E-GSM SMSXpress Module Installation Manual Location 10, Reporting events to e-mail (Phone line is good) Table 28. Location 11 worksheet Partition Segment 1 2 3 4 5 6 7 8 Description 1 Alarm restores 2 Telephone fault 3 Start ...) 6 Siren and telephone fault 7 Test reports 8 Program, download, and log full 9 Tampers 10 Short circuit and ground fault 11 Sensor lost 5 to communicate 15 Zone activity monitor 16 Reserved for future use .
Instruction Manual
Page 27
... 1 2 3 4 5 6 7 8 Description 1 Alarm restores 2 Telephone fault 3 Start download 4 Fail to communicate, data lost 12 Sensor low battery 13 Expander trouble 14 Fail to communicate 15 Zone activity monitor 16 Reserved for future use . 23 Location 12, Reporting events to pager (Phone line is good) Table 31.
... 1 2 3 4 5 6 7 8 Description 1 Alarm restores 2 Telephone fault 3 Start download 4 Fail to communicate, data lost 12 Sensor low battery 13 Expander trouble 14 Fail to communicate 15 Zone activity monitor 16 Reserved for future use . 23 Location 12, Reporting events to pager (Phone line is good) Table 31.
Instruction Manual
Page 31
27 Index A address ...3 C conventions 1 E enrollment 3 exit mode 8 F factory default 8 I installation 4 L LED ...5, 6 location programming 8 M module address 3 mounting 4 P preface ...1 product overview 2 program mode 8 programming 8 programming locations location 0 10 location 1 10 location 10 15 location 11 15 location 12 16 location 13 ... location 4 19 location 5 19 location 6 20 location 7 20 location 8 21 location 9 21 publication library 25 S safety terms and symbols 1 T technical support 25 troubleshooting 25 W web activation 2 wire gauge 5 wiring ...5
27 Index A address ...3 C conventions 1 E enrollment 3 exit mode 8 F factory default 8 I installation 4 L LED ...5, 6 location programming 8 M module address 3 mounting 4 P preface ...1 product overview 2 program mode 8 programming 8 programming locations location 0 10 location 1 10 location 10 15 location 11 15 location 12 16 location 13 ... location 4 19 location 5 19 location 6 20 location 7 20 location 8 21 location 9 21 publication library 25 S safety terms and symbols 1 T technical support 25 troubleshooting 25 W web activation 2 wire gauge 5 wiring ...5