...100 Figure 5.10 Data transfer timing 5-102 Figure 5.11 Multiword DMA data transfer timing (mode 2) 5-103 Figure 5.12 Starting of Ultra DMA data In Burst transfer 5-104 Figure 5.13 Sustained Ultra DMA data in burst 5-107 Figure ...6.6 Address translation (example in LBA mode) 6-9 Figure 6.7 Sector slip processing 6-12 Figure 6.8 Alternate cylinder assignment 6-13 Figure 6.9 Data buffer configuration 6-14 Table 1.1 Table 1.2 Table 1.3 Table 1.4 Table 1.5 Table 1.6 Specifications 1-4 Model names and product numbers 1-5 Current and power dissipation 1-6 Environmental specifications 1-7 Acoustic ...
...100 Figure 5.10 Data transfer timing 5-102 Figure 5.11 Multiword DMA data transfer timing (mode 2) 5-103 Figure 5.12 Starting of Ultra DMA data In Burst transfer 5-104 Figure 5.13 Sustained Ultra DMA data in burst 5-107 Figure ...6.6 Address translation (example in LBA mode) 6-9 Figure 6.7 Sector slip processing 6-12 Figure 6.8 Alternate cylinder assignment 6-13 Figure 6.9 Data buffer configuration 6-14 Table 1.1 Table 1.2 Table 1.3 Table 1.4 Table 1.5 Table 1.6 Specifications 1-4 Model names and product numbers 1-5 Current and power dissipation 1-6 Environmental specifications 1-7 Acoustic ...
Manual/User Guide
Page 26
... and product numbers of Heads 16 16 16 15 No. Table 1.1 Specifications (2/2) Model MHJ2181AT MHK2120AT MHK2090AT MHK2060AT Formatted Capacity 8.45 GB 8.45 GB 8.45 GB 6.00 GB No. Table 1.2 Model names and product numbers Model Name MHJ2181AT MHK2120AT MHK2090AT MHK2060AT Capacity (user area) 18.1 GB 12.0 GB 9.0 GB 6.0 GB Mounting screw Order No. of the MHJ Series and MHK Series. M3, depth 3 M3,... the CHS mode (normal BIOS specification), formatted capacity, number of cylinders, number of heads, and number of Cylinder 16,383 16,383 16,383 12,416 No. of sectors are as follows.
... and product numbers of Heads 16 16 16 15 No. Table 1.1 Specifications (2/2) Model MHJ2181AT MHK2120AT MHK2090AT MHK2060AT Formatted Capacity 8.45 GB 8.45 GB 8.45 GB 6.00 GB No. Table 1.2 Model names and product numbers Model Name MHJ2181AT MHK2120AT MHK2090AT MHK2060AT Capacity (user area) 18.1 GB 12.0 GB 9.0 GB 6.0 GB Mounting screw Order No. of the MHJ Series and MHK Series. M3, depth 3 M3,... the CHS mode (normal BIOS specification), formatted capacity, number of cylinders, number of heads, and number of Cylinder 16,383 16,383 16,383 12,416 No. of sectors are as follows.
Manual/User Guide
Page 33
...configuration of the disks and heads of disks used varies with the model, as described below. The disk enclosure contains the disk media, heads, spindle motors, actuators, and a circulating air filter. MHJ2181AT: 3 disks MHK2120AT: 2 disks MHK2090AT: 2 disks MHK2060AT: 1 disk The heads are... of a disk enclosure (DE), read /write heads. 2-2 C141-E088-03EN The number of each model. Numerals 0 to 5 indicate read /write preamplifier, and controller PCA. The disk drive consists of the contact ...
...configuration of the disks and heads of disks used varies with the model, as described below. The disk enclosure contains the disk media, heads, spindle motors, actuators, and a circulating air filter. MHJ2181AT: 3 disks MHK2120AT: 2 disks MHK2090AT: 2 disks MHK2060AT: 1 disk The heads are... of a disk enclosure (DE), read /write heads. 2-2 C141-E088-03EN The number of each model. Numerals 0 to 5 indicate read /write preamplifier, and controller PCA. The disk drive consists of the contact ...
Manual/User Guide
Page 47
... 3.8 Cable connections 3-10 C141-E088-03EN Table 3.2 Cable connector specifications ATA interface and power supply cable (44-pin type) Name Cable socket (44-pin type) Model 89361-144 Manufacturer BERG For the host interface cable, use a ribbon cable. This is because the interface is designed for ribbon cables and not for...
... 3.8 Cable connections 3-10 C141-E088-03EN Table 3.2 Cable connector specifications ATA interface and power supply cable (44-pin type) Name Cable socket (44-pin type) Model 89361-144 Manufacturer BERG For the host interface cable, use a ribbon cable. This is because the interface is designed for ribbon cables and not for...
Manual/User Guide
Page 106
...' X'0007' (Variable) (Variable) (Variable) (Variable) *6 *2 X'0000' X'xx07' X'0003' X'0078' X'0078' X'00F0' X'0078' X'0000' X'003C' X'0000' X'346B' X'4008' X'4000' Description Firmware revision (ASCII code, 8 characters, left) Model name (ASCII code, 40 characters, left) Maximum number of sectors per interrupt on READ/WRITE MULTIPLE command Reserved Capabilities *3 Reserved PIO data transfer mode *4 Reserved...
...' X'0007' (Variable) (Variable) (Variable) (Variable) *6 *2 X'0000' X'xx07' X'0003' X'0078' X'0078' X'00F0' X'0078' X'0000' X'003C' X'0000' X'346B' X'4008' X'4000' Description Firmware revision (ASCII code, 8 characters, left) Model name (ASCII code, 40 characters, left) Maximum number of sectors per interrupt on READ/WRITE MULTIPLE command Reserved Capabilities *3 Reserved PIO data transfer mode *4 Reserved...
Manual/User Guide
Page 222
Mean time to repair 1-9 Media defect 1-10 Microprocessor unit 4-14 Mis-hit 6-16 Model and product number 1-5 Model name and product number 1-5 Mounting 3-4 Move head to reference cylinder 4-15 MPU 4-14 MTBF 1-9 MTTR 1-9 Multiword DMA data transfer timing 5-103... 1-7 Power-on sequence 4-6 Power requirement 1-5 Power save 6-9 Power save mode 1-2, 6-9 Power supply connector 3-11 PreAMP 4-9 Programmable filter 4-12 Programmable filter circuit 4-12 Protocol for command abort 5-81 C141-E088-03EN Index Protocol for command execution without data transfer 5-84 R Raw attribute value 5-64 Read-ahead...
Mean time to repair 1-9 Media defect 1-10 Microprocessor unit 4-14 Mis-hit 6-16 Model and product number 1-5 Model name and product number 1-5 Mounting 3-4 Move head to reference cylinder 4-15 MPU 4-14 MTBF 1-9 MTTR 1-9 Multiword DMA data transfer timing 5-103... 1-7 Power-on sequence 4-6 Power requirement 1-5 Power save 6-9 Power save mode 1-2, 6-9 Power supply connector 3-11 PreAMP 4-9 Programmable filter 4-12 Programmable filter circuit 4-12 Protocol for command abort 5-81 C141-E088-03EN Index Protocol for command execution without data transfer 5-84 R Raw attribute value 5-64 Read-ahead...