FE 726 Users Manual
Page 5
... 52 HART Functionality...52 Maintenance ...53 Replacing the Batteries 53 Cleaning the Calibrator 54 Service Center Calibration or Repair 54 Replacement Parts 54 Accessories ...56 External Fluke Pressure Module Compatibility 56 Specifications ...59 DC Voltage Measurement and Source 59 DC mA Measurement and Source 59 Ohms Measurement 60 Ohms Source...60...
... 52 HART Functionality...52 Maintenance ...53 Replacing the Batteries 53 Cleaning the Calibrator 54 Service Center Calibration or Repair 54 Replacement Parts 54 Accessories ...56 External Fluke Pressure Module Compatibility 56 Specifications ...59 DC Voltage Measurement and Source 59 DC mA Measurement and Source 59 Ohms Measurement 60 Ohms Source...60...
FE 726 Users Manual
Page 11
... only. Multifunction Process Calibrator Introduction The Fluke 726 Multifunction Process Calibrator (referred to the functions in the world: +1-425-446-5500 USA Service: 1-888-99-FLUKE (1-888-993-5853) Or, visit Fluke's Web site at www.fluke.com. See Table 1. Contacting Fluke To order accessories, receive operating assistance, or locate the nearest Fluke distributor or Service Center, call...
... only. Multifunction Process Calibrator Introduction The Fluke 726 Multifunction Process Calibrator (referred to the functions in the world: +1-425-446-5500 USA Service: 1-888-99-FLUKE (1-888-993-5853) Or, visit Fluke's Web site at www.fluke.com. See Table 1. Contacting Fluke To order accessories, receive operating assistance, or locate the nearest Fluke distributor or Service Center, call...
FE 726 Users Manual
Page 37
... WCaution To avoid mechanically damaging the pressure module: • Never apply more than 10 ft.-lb. (13.5 Nm) of pressure modules are available from Fluke, see "Accessories". Multifunction Process Calibrator Using Measure Mode Gage 700P06 PRESSURE MODULE RANGE 100 PSIG 700 kPa 7 bar BURST PRESSURE 300 PSIG Low Differential 700P04 PRESSURE MODULE...
... WCaution To avoid mechanically damaging the pressure module: • Never apply more than 10 ft.-lb. (13.5 Nm) of pressure modules are available from Fluke, see "Accessories". Multifunction Process Calibrator Using Measure Mode Gage 700P06 PRESSURE MODULE RANGE 100 PSIG 700 kPa 7 bar BURST PRESSURE 300 PSIG Low Differential 700P04 PRESSURE MODULE...
FE 726 Users Manual
Page 48
The modules vary in the SOURCE field. Refer to be tested. 726 Users Manual Sourcing Pressure The Calibrator sources pressure by measuring pressure supplied by a pump or other sources, and displaying the pressure in use, media, and ... off the valve and slowly bleed off the pressure before attaching the pressure module to a Fluke pressure module which makes it a calibrated source. Always apply appropriate torque between the fittings and the body of pressure modules are available from Fluke, see "Accessories". Figure 18 shows how to connect a pump to the pressure line.
The modules vary in the SOURCE field. Refer to be tested. 726 Users Manual Sourcing Pressure The Calibrator sources pressure by measuring pressure supplied by a pump or other sources, and displaying the pressure in use, media, and ... off the valve and slowly bleed off the pressure before attaching the pressure module to a Fluke pressure module which makes it a calibrated source. Always apply appropriate torque between the fittings and the body of pressure modules are available from Fluke, see "Accessories". Figure 18 shows how to connect a pump to the pressure line.
FE 726 Users Manual
Page 64
...water or water and mild soap. Refer to "Contacting Fluke" at the beginning of each replaceable part. Replacement Parts Item 1 2 3 4 5 6 7 8 9 10 11 Description AA alkaline batteries Case screws Battery door Accessory mount Tilt stand Battery door 1/4-turn fasteners TL75 series ...test leads Test lead, red Test lead, black 726 Product Overview Manual AC72 alligator clip, red AC72 alligator clip, black 725/726 CD ROM, contains User Manual PN Qty. 376756 4 ...
...water or water and mild soap. Refer to "Contacting Fluke" at the beginning of each replaceable part. Replacement Parts Item 1 2 3 4 5 6 7 8 9 10 11 Description AA alkaline batteries Case screws Battery door Accessory mount Tilt stand Battery door 1/4-turn fasteners TL75 series ...test leads Test lead, red Test lead, black 726 Product Overview Manual AC72 alligator clip, red AC72 alligator clip, black 725/726 CD ROM, contains User Manual PN Qty. 376756 4 ...
FE 726 Users Manual
Page 66
... and above All ranges through 1000 psi Available on all pressure ranges Available on the display per the following table. mm. 726 Users Manual Accessories For more information about these accessories, contact your Fluke representative about new pressure modules not listed here. • 700HTP 0 to 10,000 PSI Pump • 700PTP -11.6 to 360...
... and above All ranges through 1000 psi Available on all pressure ranges Available on the display per the following table. mm. 726 Users Manual Accessories For more information about these accessories, contact your Fluke representative about new pressure modules not listed here. • 700HTP 0 to 10,000 PSI Pump • 700PTP -11.6 to 360...
FE 726 Users Manual
Page 77
Calibration, 54 Celcius and Fahrenheit, 15 Cleaning calibrator, 54 Cold Junction Compensation (CJC), 15 Commands Remote Control, 52 configuration menus, 14 Connections for pressure sourcing, 39 Contact Information, 1 Data Recall, 44 display contrast adjustment, 14 Display, 13 -E- Electrical parameters measurement, 20 sourcing, 32 -F- frequency output voltage, 15 67 Accessories, 56 Auto ramping output, 42 -B- -D- Index -0- 0% output parameter, setting, 41 -1- 100% output parameter, setting, 41 -4- 4 to 20 mA transmitter simulating, 30 -A- Battery, replacing, 53 -C-
Calibration, 54 Celcius and Fahrenheit, 15 Cleaning calibrator, 54 Cold Junction Compensation (CJC), 15 Commands Remote Control, 52 configuration menus, 14 Connections for pressure sourcing, 39 Contact Information, 1 Data Recall, 44 display contrast adjustment, 14 Display, 13 -E- Electrical parameters measurement, 20 sourcing, 32 -F- frequency output voltage, 15 67 Accessories, 56 Auto ramping output, 42 -B- -D- Index -0- 0% output parameter, setting, 41 -1- 100% output parameter, setting, 41 -4- 4 to 20 mA transmitter simulating, 30 -A- Battery, replacing, 53 -C-