FE 51 & 52 II Users Manual
Page 4
51 & 52 Series II Users Manual Maintenance...13 Replacing the Batteries 13 Cleaning the Case and Holster 13 Calibration ...13 Specifications ...13 Environmental...13 General...14 80 PK-1 Thermocouple (supplied with thermometer 14 Electrical...14 Replacement Parts and Accessories 15 ii
51 & 52 Series II Users Manual Maintenance...13 Replacing the Batteries 13 Cleaning the Case and Holster 13 Calibration ...13 Specifications ...13 Environmental...13 General...14 80 PK-1 Thermocouple (supplied with thermometer 14 Electrical...14 Replacement Parts and Accessories 15 ii
FE 51 & 52 II Users Manual
Page 16
... bath or a dry well calibrator). 3. The allowable adjustment range is ± 5.0 oC or K, and ± 9.0 oF. 1. Press M to compensate for the errors of a specific thermocouple. Using the Offset to Adjust for Probe Errors Use the offset option in Setup to adjust the thermometer's readings to step through the maximum... minimum (MIN), or the average (AVG) readings. Allow the readings to freeze the readings on the display. 2. Viewing the MIN, MAX, and AVG Readings 1. 51 & 52 Series II Users Manual Holding the Displayed Readings 1. Press h to stabilize. 4. The display shows H. 2.
... bath or a dry well calibrator). 3. The allowable adjustment range is ± 5.0 oC or K, and ± 9.0 oF. 1. Press M to compensate for the errors of a specific thermocouple. Using the Offset to Adjust for Probe Errors Use the offset option in Setup to adjust the thermometer's readings to step through the maximum... minimum (MIN), or the average (AVG) readings. Allow the readings to freeze the readings on the display. 2. Viewing the MIN, MAX, and AVG Readings 1. 51 & 52 Series II Users Manual Holding the Displayed Readings 1. Press h to stabilize. 4. The display shows H. 2.
FE 51 & 52 II Users Manual
Page 17
... soft rag. 51 & 52 Series II Maintenance Calibration To ensure that the thermometer performs to its accuracy specifications, Fluke recommends that you or follow the calibration procedure in the service manual listed in Table 1 before replacing the batteries. 1. Specifications Environmental Operating ... cleaner. Replace the three AA batteries. 4. Turn off the thermometer if necessary. 2. To calibrate the thermometer, contact Fluke for the Service Center nearest you calibrate the thermometer annually, starting one year after purchase. Maintenance Replacing the Batteries Refer...
... soft rag. 51 & 52 Series II Maintenance Calibration To ensure that the thermometer performs to its accuracy specifications, Fluke recommends that you or follow the calibration procedure in the service manual listed in Table 1 before replacing the batteries. 1. Specifications Environmental Operating ... cleaner. Replace the three AA batteries. 4. Turn off the thermometer if necessary. 2. To calibrate the thermometer, contact Fluke for the Service Center nearest you calibrate the thermometer annually, starting one year after purchase. Maintenance Replacing the Batteries Refer...
FE 51 & 52 II Users Manual
Page 19
....n3doEC-t(y0p.5e:o±F[)0] .05 % of [below −100 oC (−148 oF): add 0.15 % of reading for J-, K-, E-, and N-type; The above specifications do not include thermocouple error. 51 & 52 Series II Replacement Parts and Accessories Replacement Parts and Accessories Accessory Part Number Holster and Flex Stand™ Assembly 1272438 AA NEDA...
....n3doEC-t(y0p.5e:o±F[)0] .05 % of [below −100 oC (−148 oF): add 0.15 % of reading for J-, K-, E-, and N-type; The above specifications do not include thermocouple error. 51 & 52 Series II Replacement Parts and Accessories Replacement Parts and Accessories Accessory Part Number Holster and Flex Stand™ Assembly 1272438 AA NEDA...