Fluke 51II, 52II, 53II, and 54II Thermometer Datasheet
Page 1
...°F, or Kelvin (K) • Sleep mode increases battery life • Battery door allows easy battery replacement without breaking the calibration seal Additional features for the 53 and 54 Series II: • Data Logging up to 500 points of data with user adjustable... holster Two bead probe thermocouples 80PK-1 (54+52) One bead probe thermocouple 80PK-1 (51+53) Ordering Information Fluke 51 II Thermometer Fluke 52 II Thermometer Fluke 53 II Thermometer Fluke 54 II Thermometer FVF-SC1 FlukeView Forms Software including interface cable Specifications Temperature range...
...°F, or Kelvin (K) • Sleep mode increases battery life • Battery door allows easy battery replacement without breaking the calibration seal Additional features for the 53 and 54 Series II: • Data Logging up to 500 points of data with user adjustable... holster Two bead probe thermocouples 80PK-1 (54+52) One bead probe thermocouple 80PK-1 (51+53) Ordering Information Fluke 51 II Thermometer Fluke 52 II Thermometer Fluke 53 II Thermometer Fluke 54 II Thermometer FVF-SC1 FlukeView Forms Software including interface cable Specifications Temperature range...
FE 51 & 52 II Users Manual
Page 4
51 & 52 Series II Users Manual Maintenance...13 Replacing the Batteries 13 Cleaning the Case and Holster 13 Calibration ...13 Specifications ...13 Environmental...13 General...14 80 PK-1 Thermocouple (supplied with thermometer 14 Electrical...14 Replacement Parts and Accessories 15 ii
51 & 52 Series II Users Manual Maintenance...13 Replacing the Batteries 13 Cleaning the Case and Holster 13 Calibration ...13 Specifications ...13 Environmental...13 General...14 80 PK-1 Thermocouple (supplied with thermometer 14 Electrical...14 Replacement Parts and Accessories 15 ii
FE 51 & 52 II Users Manual
Page 16
51 & 52 Series II Users Manual Holding the Displayed Readings 1. Model 52: Press T... to turn off the HOLD function. In Setup change the offset until the primary display reading matches the calibration temperature. (See "Changing Setup Options.") 12 Place the thermocouple in a known, stable temperature environment (such as an ice... bath or a dry well calibrator). 3. Press h to Adjust for the errors of a specific thermocouple. Press h again to step through the maximum (MAX...
51 & 52 Series II Users Manual Holding the Displayed Readings 1. Model 52: Press T... to turn off the HOLD function. In Setup change the offset until the primary display reading matches the calibration temperature. (See "Changing Setup Options.") 12 Place the thermocouple in a known, stable temperature environment (such as an ice... bath or a dry well calibrator). 3. Press h to Adjust for the errors of a specific thermocouple. Press h again to step through the maximum (MAX...
FE 51 & 52 II Users Manual
Page 17
... Case and Holster Use soap and water or a mild commercial cleaner. To calibrate the thermometer, contact Fluke for the Service Center nearest you calibrate the thermometer annually, starting one year after purchase. Wipe with a damp sponge or soft rag. 51 & 52 Series II Maintenance Calibration To ensure that the thermometer performs to its accuracy specifications...
... Case and Holster Use soap and water or a mild commercial cleaner. To calibrate the thermometer, contact Fluke for the Service Center nearest you calibrate the thermometer annually, starting one year after purchase. Wipe with a damp sponge or soft rag. 51 & 52 Series II Maintenance Calibration To ensure that the thermometer performs to its accuracy specifications...