Fluke 51II, 52II, 53II, and 54II Thermometer Datasheet
Page 1
...-eng Rev. 01 C25 80PK-26 80PK-25 FVF-SC1 TPAK The Fluke 50 Series II contact thermometers offer fast response and laboratory accuracy (0.05% + 0.3°C) in a rugged handheld test tool. •...51+53) Ordering Information Fluke 51 II Thermometer Fluke 52 II Thermometer Fluke 53 II Thermometer Fluke 54 II Thermometer FVF-SC1 FlukeView Forms Software including interface cable Specifications Temperature range: J-type Thermocouples K-type Thermocouples T-type Thermocouples E-type Thermocouples N-type** Thermocouples R** and S-type** Thermocouples Temperature accuracy...
...-eng Rev. 01 C25 80PK-26 80PK-25 FVF-SC1 TPAK The Fluke 50 Series II contact thermometers offer fast response and laboratory accuracy (0.05% + 0.3°C) in a rugged handheld test tool. •...51+53) Ordering Information Fluke 51 II Thermometer Fluke 52 II Thermometer Fluke 53 II Thermometer Fluke 54 II Thermometer FVF-SC1 FlukeView Forms Software including interface cable Specifications Temperature range: J-type Thermocouples K-type Thermocouples T-type Thermocouples E-type Thermocouples N-type** Thermocouples R** and S-type** Thermocouples Temperature accuracy...
FE 51 & 52 II Users Manual
Page 17
...if necessary. 2. Replace the three AA batteries. 4. Wipe with a damp sponge or soft rag. 51 & 52 Series II Maintenance Calibration To ensure that the thermometer performs to its accuracy specifications, Fluke recommends that you or follow the calibration procedure in the service manual listed in Table 1 before replacing the...Replacement Parts and Accessories." Maintenance Replacing the Batteries Refer to +140 oF) Humidity Non condensing To calibrate the thermometer, contact Fluke for the Service Center nearest you calibrate the thermometer annually, starting one year after purchase.
...if necessary. 2. Replace the three AA batteries. 4. Wipe with a damp sponge or soft rag. 51 & 52 Series II Maintenance Calibration To ensure that the thermometer performs to its accuracy specifications, Fluke recommends that you or follow the calibration procedure in the service manual listed in Table 1 before replacing the...Replacement Parts and Accessories." Maintenance Replacing the Batteries Refer to +140 oF) Humidity Non condensing To calibrate the thermometer, contact Fluke for the Service Center nearest you calibrate the thermometer annually, starting one year after purchase.
FE 51 & 52 II Users Manual
Page 18
51 & 52 Series II Users Manual General Weight 280 g (10 oz) Dimensions (without holster) 2.8 cm × 7.8 cm × 16.2 cm (1.1 in × 3 in × 6.4 in) Battery ... / oF / K ≥ 1000o 14 Equipment of Impulse Withstand Voltage protection provided. Example include protect electronic circuits. 80 PK-1 Thermocouple (supplied with thermometer) Type Temperature Range Accuracy Type K, Chromel Alumel, bead style −40 oC to +260 oC (−40 oF to +500 oF) ± 1.1 oC (± 2.0 oF) Electrical Measurement Range Display...
51 & 52 Series II Users Manual General Weight 280 g (10 oz) Dimensions (without holster) 2.8 cm × 7.8 cm × 16.2 cm (1.1 in × 3 in × 6.4 in) Battery ... / oF / K ≥ 1000o 14 Equipment of Impulse Withstand Voltage protection provided. Example include protect electronic circuits. 80 PK-1 Thermocouple (supplied with thermometer) Type Temperature Range Accuracy Type K, Chromel Alumel, bead style −40 oC to +260 oC (−40 oF to +500 oF) ± 1.1 oC (± 2.0 oF) Electrical Measurement Range Display...
FE 51 & 52 II Users Manual
Page 19
...51 & 52 Series II Replacement Parts and Accessories Replacement Parts and Accessories Accessory Part Number Holster and Flex Stand™ Assembly 1272438 AA NEDA 15A IEC LR6 batteries 376756 80PK-1 K-Type Bead Thermocouple 773135 CD-ROM 1276106 Service Manual 1276123 15 Electrical (cont.) Measurement Accuracy...Commercial Limits per EN50081-1 1 V (Maximum voltage difference between T1 and T2) ITS-90 Applicable Standards NIST-175 Accuracy is between 18 soCpe(c6i4fieodF)foarnadm2b8ieonCt (t8e2mopFe)rafotur raesperiod of reading for T-type] Susceptibility: ±2 oC (...
...51 & 52 Series II Replacement Parts and Accessories Replacement Parts and Accessories Accessory Part Number Holster and Flex Stand™ Assembly 1272438 AA NEDA 15A IEC LR6 batteries 376756 80PK-1 K-Type Bead Thermocouple 773135 CD-ROM 1276106 Service Manual 1276123 15 Electrical (cont.) Measurement Accuracy...Commercial Limits per EN50081-1 1 V (Maximum voltage difference between T1 and T2) ITS-90 Applicable Standards NIST-175 Accuracy is between 18 soCpe(c6i4fieodF)foarnadm2b8ieonCt (t8e2mopFe)rafotur raesperiod of reading for T-type] Susceptibility: ±2 oC (...