Fluke 51II, 52II, 53II, and 54II Thermometer Datasheet
Page 1
... probe thermocouples 80PK-1 (54+52) One bead probe thermocouple 80PK-1 (51+53) Ordering Information Fluke 51 II Thermometer Fluke 52 II Thermometer Fluke 53 II Thermometer Fluke 54 II Thermometer FVF-SC1 FlukeView Forms Software including interface cable Specifi...176;F) ] ± [ 0.05% + 0.4°C (0.7°F) ] ± [ 0.20% + 0.3°C (0.5°F) ] ± [ 0.50% + 0.3°C (0.5°F) ] **Only the Fluke Models 53 and 54 Series II thermometers are capable of measuring N, R, and S-type thermocouples. Battery life: 1000 hours typical, AA Size (HxWxD): 173 x 86 x 38...
... probe thermocouples 80PK-1 (54+52) One bead probe thermocouple 80PK-1 (51+53) Ordering Information Fluke 51 II Thermometer Fluke 52 II Thermometer Fluke 53 II Thermometer Fluke 54 II Thermometer FVF-SC1 FlukeView Forms Software including interface cable Specifi...176;F) ] ± [ 0.05% + 0.4°C (0.7°F) ] ± [ 0.20% + 0.3°C (0.5°F) ] ± [ 0.50% + 0.3°C (0.5°F) ] **Only the Fluke Models 53 and 54 Series II thermometers are capable of measuring N, R, and S-type thermocouples. Battery life: 1000 hours typical, AA Size (HxWxD): 173 x 86 x 38...
FE 51 & 52 II Users Manual
Page 1
® 51 & 52 Series II Thermometer English September 1999 Rev.1, 6/01 © 1999-2001 Fluke Corporation, All rights reserved. Printed in USA All product names are trademarks of their respective companies. Users Manual
® 51 & 52 Series II Thermometer English September 1999 Rev.1, 6/01 © 1999-2001 Fluke Corporation, All rights reserved. Printed in USA All product names are trademarks of their respective companies. Users Manual
FE 51 & 52 II Users Manual
Page 5
... Address correspondence to use external J-, K-, T-, and Etype thermocouples (temperature probes) as specified in this manual. 51 & 52 Series II Introduction The Fluke Model 51 and Model 52 Thermometers ("the thermometer") are microprocessor-based, digital thermometers designed to : Fluke Corporation P.O. Box 1186 5602 BD Eindhoven The Netherlands Visit us on the World Wide Web at...
... Address correspondence to use external J-, K-, T-, and Etype thermocouples (temperature probes) as specified in this manual. 51 & 52 Series II Introduction The Fluke Model 51 and Model 52 Thermometers ("the thermometer") are microprocessor-based, digital thermometers designed to : Fluke Corporation P.O. Box 1186 5602 BD Eindhoven The Netherlands Visit us on the World Wide Web at...
FE 51 & 52 II Users Manual
Page 17
To calibrate the thermometer, contact Fluke for the Service Center nearest you calibrate the thermometer annually, starting one year after purchase. Specifications Environmental Operating −10 oC to 50 oC Temperature (... and tighten the screw. Turn off the thermometer if necessary. 2. Wipe with a damp sponge or soft rag. 51 & 52 Series II Maintenance Calibration To ensure that the thermometer performs to its accuracy specifications, Fluke recommends that you or follow the calibration procedure in the service manual listed in Table 1 before replacing the...
To calibrate the thermometer, contact Fluke for the Service Center nearest you calibrate the thermometer annually, starting one year after purchase. Specifications Environmental Operating −10 oC to 50 oC Temperature (... and tighten the screw. Turn off the thermometer if necessary. 2. Wipe with a damp sponge or soft rag. 51 & 52 Series II Maintenance Calibration To ensure that the thermometer performs to its accuracy specifications, Fluke recommends that you or follow the calibration procedure in the service manual listed in Table 1 before replacing the...