Fluke 51II, 52II, 53II, and 54II Thermometer Datasheet
Page 1
...-eng Rev. 01 C25 80PK-26 80PK-25 FVF-SC1 TPAK The Fluke 50 Series II contact thermometers offer fast response and laboratory accuracy (0.05% + 0.3°C) in a rugged handheld test tool. •...51+53) Ordering Information Fluke 51 II Thermometer Fluke 52 II Thermometer Fluke 53 II Thermometer Fluke 54 II Thermometer FVF-SC1 FlukeView Forms Software including interface cable Specifications Temperature range: J-type Thermocouples K-type Thermocouples T-type Thermocouples E-type Thermocouples N-type** Thermocouples R** and S-type** Thermocouples Temperature accuracy...
...-eng Rev. 01 C25 80PK-26 80PK-25 FVF-SC1 TPAK The Fluke 50 Series II contact thermometers offer fast response and laboratory accuracy (0.05% + 0.3°C) in a rugged handheld test tool. •...51+53) Ordering Information Fluke 51 II Thermometer Fluke 52 II Thermometer Fluke 53 II Thermometer Fluke 54 II Thermometer FVF-SC1 FlukeView Forms Software including interface cable Specifications Temperature range: J-type Thermocouples K-type Thermocouples T-type Thermocouples E-type Thermocouples N-type** Thermocouples R** and S-type** Thermocouples Temperature accuracy...
FE 51 & 52 II Users Manual
Page 17
...to the safety information in "Replacement Parts and Accessories." Replace the three AA batteries. 4. Wipe with a damp sponge or soft rag. 51 & 52 Series II Maintenance Calibration To ensure that the thermometer performs to +140 oF) Humidity Non condensing Replace the battery door and tighten the...oC to 50 oC Temperature (14 oF to 122 oF) Storage −40 oC to +60 oC Temperature (−40 oF to its accuracy specifications, Fluke recommends that you or follow the calibration procedure in the service manual listed in Table 1 before replacing the batteries. 1. To calibrate the ...
...to the safety information in "Replacement Parts and Accessories." Replace the three AA batteries. 4. Wipe with a damp sponge or soft rag. 51 & 52 Series II Maintenance Calibration To ensure that the thermometer performs to +140 oF) Humidity Non condensing Replace the battery door and tighten the...oC to 50 oC Temperature (14 oF to 122 oF) Storage −40 oC to +60 oC Temperature (−40 oF to its accuracy specifications, Fluke recommends that you or follow the calibration procedure in the service manual listed in Table 1 before replacing the batteries. 1. To calibrate the ...
FE 51 & 52 II Users Manual
Page 18
51 & 52 Series II Users Manual General Weight 280 g (10 oz) Dimensions (without holster) 2.8 cm × 7.8 cm × 16.2 cm (1.1 in × 3 in × 6.4 in) Battery ... / oF / K ≥ 1000o 14 Equipment of Impulse Withstand Voltage protection provided. Example include protect electronic circuits. 80 PK-1 Thermocouple (supplied with thermometer) Type Temperature Range Accuracy Type K, Chromel Alumel, bead style −40 oC to +260 oC (−40 oF to +500 oF) ± 1.1 oC (± 2.0 oF) Electrical Measurement Range Display...
51 & 52 Series II Users Manual General Weight 280 g (10 oz) Dimensions (without holster) 2.8 cm × 7.8 cm × 16.2 cm (1.1 in × 3 in × 6.4 in) Battery ... / oF / K ≥ 1000o 14 Equipment of Impulse Withstand Voltage protection provided. Example include protect electronic circuits. 80 PK-1 Thermocouple (supplied with thermometer) Type Temperature Range Accuracy Type K, Chromel Alumel, bead style −40 oC to +260 oC (−40 oF to +500 oF) ± 1.1 oC (± 2.0 oF) Electrical Measurement Range Display...
FE 51 & 52 II Users Manual
Page 19
... Emmisions: Commercial Limits per EN50081-1 1 V (Maximum voltage difference between T1 and T2) ITS-90 Applicable Standards NIST-175 Accuracy is between 18 soCpe(c6i4fieodF)foarnadm2b8ieonCt (t8e2mopFe)rafotur raesperiod of reading for T-type] [ts0(obp.0e0e+.l10co85iw2%fieoo−FodF1f)p+.... and 0.45 % of reading for J-, K-, E-, and N-type; The above specifications do not include thermocouple error. 51 & 52 Series II Replacement Parts and Accessories Replacement Parts and Accessories Accessory Part Number Holster and Flex Stand™ Assembly 1272438...
... Emmisions: Commercial Limits per EN50081-1 1 V (Maximum voltage difference between T1 and T2) ITS-90 Applicable Standards NIST-175 Accuracy is between 18 soCpe(c6i4fieodF)foarnadm2b8ieonCt (t8e2mopFe)rafotur raesperiod of reading for T-type] [ts0(obp.0e0e+.l10co85iw2%fieoo−FodF1f)p+.... and 0.45 % of reading for J-, K-, E-, and N-type; The above specifications do not include thermocouple error. 51 & 52 Series II Replacement Parts and Accessories Replacement Parts and Accessories Accessory Part Number Holster and Flex Stand™ Assembly 1272438...