FE 1587-1577 Users Manual
Page 11
...manual describes the operation of all models, all illustrations and examples assume use of danger from the primary supply level (overhead or underground utility service). CAT IV meters are designed to protect against transients in the world Visit Fluke's web site at: www.fluke...voltage and current • Resistance • Voltage and current frequency • Temperature (Model 1587) Contacting Fluke • Diodes (Model 1587) • Continuity • Capacitance (Model 1587) • Insulation testing To contact Fluke, call: 1-888-993-5853 in USA 1-800-363-5853 in Canada +31-402-...
...manual describes the operation of all models, all illustrations and examples assume use of danger from the primary supply level (overhead or underground utility service). CAT IV meters are designed to protect against transients in the world Visit Fluke's web site at: www.fluke...voltage and current • Resistance • Voltage and current frequency • Temperature (Model 1587) Contacting Fluke • Diodes (Model 1587) • Continuity • Capacitance (Model 1587) • Insulation testing To contact Fluke, call: 1-888-993-5853 in USA 1-800-363-5853 in Canada +31-402-...
FE 1587-1577 Users Manual
Page 12
...When using the test leads, keep your fingers behind the finger guards. 2 If in this manual. These voltages pose a shock hazard. • Replace the battery as soon as specified in doubt, have the Meter serviced. • Always use the proper terminal, switch position, and range for a list of data...capacitance. • Do not use the Meter or test leads if they appear damaged, or if the Meter is not operating properly. 1587/1577 Users Manual Safety Information Use the Meter only as the low battery indicator (b) appears. • Disconnect circuit power and discharge all high-voltage ...
...When using the test leads, keep your fingers behind the finger guards. 2 If in this manual. These voltages pose a shock hazard. • Replace the battery as soon as specified in doubt, have the Meter serviced. • Always use the proper terminal, switch position, and range for a list of data...capacitance. • Do not use the Meter or test leads if they appear damaged, or if the Meter is not operating properly. 1587/1577 Users Manual Safety Information Use the Meter only as the low battery indicator (b) appears. • Disconnect circuit power and discharge all high-voltage ...
FE 1587-1577 Users Manual
Page 20
...when the rotary switch is displayed. The message appears briefly and a single beep will not operate at all until the battery is replaced. Service Meter if this is turned to perform an insulation test. The Meter will sound when you move the switch in use Source voltage rating ... batt bat OPEn LEAd 15--Err Appears on the 1587T. Model detect error. The t button is disabled until the battery is replaced. 1587/1577 Users Manual Table 4. Display Indicators (cont.) Feature Auto Range ManualRange 610000mV 2500V 1000V T Description Display range in or out of the c position.
...when the rotary switch is displayed. The message appears briefly and a single beep will not operate at all until the battery is replaced. Service Meter if this is turned to perform an insulation test. The Meter will sound when you move the switch in use Source voltage rating ... batt bat OPEn LEAd 15--Err Appears on the 1587T. Model detect error. The t button is disabled until the battery is replaced. 1587/1577 Users Manual Table 4. Display Indicators (cont.) Feature Auto Range ManualRange 610000mV 2500V 1000V T Description Display range in or out of the c position.