Popular Fluke 1587 Manual Pages

FE 1587-1577 Users Manual - Page 1

Printed in USA All product names are trademarks of their respective companies. ® 1587/1577 Insulation Multimeters Users Manual PN 2401027 April 2005 Rev.1, 1/06 © 2005-2006 Fluke Corporation. All rights reserved.
FE 1587-1577 Users Manual - Page 4

1587/1577 Users Manual Making Basic Measurements 16 Measuring AC and DC Voltage 17 Measuring Temperature (Model 1587 and 1587T 18 Measuring Resistance 19 Measuring Capacitance (Model 1587 and 1587T 19 Testing for Continuity 20 Testing Diodes (Model 1587 and 1587T 21 Measuring AC or DC Current 22 Testing Insulation ...24 Measuring Frequency (Model 1587 and 1587T 25 Cleaning...27 Testing ...
FE 1587-1577 Users Manual - Page 6

1587/1577 Users Manual iv
FE 1587-1577 Users Manual - Page 11

... underground utility service). 1587/1577 Insulation Multimeters Introduction The Fluke Models 1587,1587T, and 1577 are designed to protect against transients in the world Visit Fluke's web site at: www.fluke.com Register your Meter at the distribution level; CAT III meters are designed to protect against transients from anywhere in Fixed equipment installations at : register.fluke.com...
FE 1587-1577 Users Manual - Page 12

.... • When using the test leads, keep your fingers behind the finger guards. 2 1587/1577 Users Manual Safety Information Use the Meter only as specified in doubt, have the Meter serviced. • Always use the proper terminal, switch position, and range for a list of data. These voltages pose a shock hazard. • Replace the battery as soon...
FE 1587-1577 Users Manual - Page 14

... Meter on . 4 1587/1577 Users Manual Accessories Model Leads Probes Clips 1587 and 1587T TL224 TP74 ...Probe Yes Yes Yes Yes Yes Yes No Yes Battery Saver (Sleep Mode) The Meter enters the "Sleep mode" and blanks the display if there is turned on . Test Lead Alert To remind you to check that the test leads are in the MIN MAX AVG recording mode, AutoHold mode, insulation test...
FE 1587-1577 Users Manual - Page 16

... the rotary switch. The last selected high voltage setting is turned off. Beeper turns on the 1587T. Ohms from 0.01 MΩ to activate smoothing during insulation testing (1587 only). There is no ranging in memory when the Meter is retained in this function. Press the blue button to 2 GΩ. The buttons are shown ...
FE 1587-1577 Users Manual - Page 20

...when an open thermocouple is replaced. Service Meter if this is replaced. Appears on the primary display and indicates that the battery is turned to perform an insulation test. Test lead alert. The t button is disabled until the battery is detected. 1587/1577 Users Manual Table 4. Appears when insulation test voltage is too low for insulation test: 50, 100, 250, 500 (default...
FE 1587-1577 Users Manual - Page 22

...the software version number. E switch position displays the model number. The display shows S - - - until the button is turned OFF. The remaining positions show all LCD segments. Enables "Smoothing" mode for insulation test. q input terminal for all measurements except insulation test. Power-up options are active when the button is released. 1587/1577 Users Manual .
FE 1587-1577 Users Manual - Page 24

...one second or turn the Meter on the display. • Press m to increment the range. In the Manual Range mode, press r to step through the high (MAX), low (MIN), average (AVG), and present ... press h again. After the highest range, the Meter wraps to activate MIN MAX AVG mode. 1587/1577 Users Manual To use MIN MAX AVG recording: • Make sure the Meter is in the desired measurement...
FE 1587-1577 Users Manual - Page 32

..., set up the Meter as shown in parallel with a circuit or component when the leads are plugged into the current terminals. Turn power OFF to the circuit under test, break circuit, insert Meter in -circuit current measurement when the open-circuit potential to make an in series, turn power ON. 1587/1577 Users Manual Measuring...
FE 1587-1577 Users Manual - Page 34

... and remove power before testing. Turn the knob to select the voltage. 4. The T icon appears on the primary display until you press t and a valid insulation resistance reading is inhibited. Press r to INSULATION position. 1587/1577 Users Manual Testing Insulation Insulation tests should only be performed on the test points and release the t button. See Testing the Fuse later in this...
FE 1587-1577 Users Manual - Page 38

1587/1577 Users Manual Replacing the Batteries and Fuse Replace the fuse and batteries as the battery indicator (b) appears. • Use ONLY fuses with the amperage, interrupt, voltage, and speed ratings specified. • Turn the rotary switch to OFF and remove the test leads from the terminals. 1. Follow the steps below to turn the battery door lock until the lock...
FE 1587-1577 Users Manual - Page 40

1587/1577 Users Manual Altitude Operating 2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V Storage 12,000 m Over-Range Capability 110% of range except for capacitance which is 1 % Compliance to EN 61557 IEC61557-1, IEC61557-2 Electrical Specifications AC Voltage Measurement 1587 and 1587T Accuracy Range Resolution 600.0 mV 6.000 V 60.00...
FE 1587-1577 Users Manual - Page 46

...MΩ to 600 MΩ Model 1587T 0.01 MΩ to 100 MΩ Test Voltages Model 1587 50, 100, 250, 500, 1000 V Model 1577 500, 1000 V Model 1587T 50, 100 V Test Voltage Accuracy 20 %, - 0 % Short-Circuit Test Current 1 mA nominal Auto Discharge Discharge time 30 V prior to initialization of the instrument. 1587/1577 Users Manual Temperature Measurement (1587 and 1587T Only) Range...

Fluke 1587 Reviews

Do you have an experience with the Fluke 1587 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fluke yet.

Popular Fluke 1587 Search Terms

The following terms are frequently used to search for Fluke 1587 support:

Ask a New Question
Use the box below to post a new question about Fluke 1587.
Manuals / Documents
Download any of our Fluke 1587 manuals for free!

We have the following 1 documents available for the Fluke 1587:
  • FE 1587-1577 Users Manual
Related Items

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 1587 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke 1587 user reviews and customer ratings available at ReviewOwl.com.