Using the Common Event Enabler 8.x on Windows Platforms
Page 24
... blocks access to perform this step results in progress by Symantec Protection Engine. Failure to (deletes) the file on the VNX Data Movers or Unity Managing the VC Client NAS servers. 6. Set the LimitChoiceStop option to the Symantec Protection Engine Status page. Installing the Common Event Enabler 4. Install the Trend AV engine. Click Configuration and Resources. 2. Table 5. Configure virus-checking parameters on the Windows AV machines. Install CAVA (as part...
... blocks access to perform this step results in progress by Symantec Protection Engine. Failure to (deletes) the file on the VNX Data Movers or Unity Managing the VC Client NAS servers. 6. Set the LimitChoiceStop option to the Symantec Protection Engine Status page. Installing the Common Event Enabler 4. Install the Trend AV engine. Click Configuration and Resources. 2. Table 5. Configure virus-checking parameters on the Windows AV machines. Install CAVA (as part...
VNX Command Line Interface Reference for File 8.1
Page 65
... Commands fs_dhsm Manages the VNX FileMover file system connections. SYNOPSIS fs_dhsm -list | -info [|id=] | -modify {|id=}[-state enabled] [-popup_timeout ][-backup {offline|passthrough}] [-log {on|off}][-max_log_size ][-offline_attr {on|off}] [-read_policy_override {none|full|passthrough|partial}]} | -modify {|id=}[-state disabled] | -connection {|id=} -list | -info [] | -create -type {nfsv3|nfsv2} -secondary :/ [-read_policy_override {full|passthrough|partial|none}] [-useRootCred {true|false}][-proto {UDP|TCP}][-nfsPort ] [-mntPort ][-mntVer {3|2|1}][-localPort ] |-create -type cifs -admin...
... Commands fs_dhsm Manages the VNX FileMover file system connections. SYNOPSIS fs_dhsm -list | -info [|id=] | -modify {|id=}[-state enabled] [-popup_timeout ][-backup {offline|passthrough}] [-log {on|off}][-max_log_size ][-offline_attr {on|off}] [-read_policy_override {none|full|passthrough|partial}]} | -modify {|id=}[-state disabled] | -connection {|id=} -list | -info [] | -create -type {nfsv3|nfsv2} -secondary :/ [-read_policy_override {full|passthrough|partial|none}] [-useRootCred {true|false}][-proto {UDP|TCP}][-nfsPort ] [-mntPort ][-mntVer {3|2|1}][-localPort ] |-create -type cifs -admin...
VNX Command Line Interface Reference for File 8.1
Page 721
... no server or domain has been specified, the operations are performed to the configured CIFS servers on the Data Movers. The VNX stores the GPO settings in a GPO cache on a Data Mover, the VNX reads the settings stored in the GPO cache, and then retrieves the most recent GPO settings from the Windows domain controller. The server refers to all Data Movers. The server Commands server_security Manages the security policy settings for the Data Mover...
... no server or domain has been specified, the operations are performed to the configured CIFS servers on the Data Movers. The VNX stores the GPO settings in a GPO cache on a Data Mover, the VNX reads the settings stored in the GPO cache, and then retrieves the most recent GPO settings from the Windows domain controller. The server refers to all Data Movers. The server Commands server_security Manages the security policy settings for the Data Mover...
VNX Command Line Interface Reference for Block 5.33
Page 15
... longer covered in use CLI commands to configure, manage, or obtain the status of EMC systems. This version of the manual covers up -to-date information on the servers you will result in minor or moderate injury. Preface As part of an effort to improve and enhance the performance and capabilities of its product lines, revisions of product hardware and software are expected to...
... longer covered in use CLI commands to configure, manage, or obtain the status of EMC systems. This version of the manual covers up -to-date information on the servers you will result in minor or moderate injury. Preface As part of an effort to improve and enhance the performance and capabilities of its product lines, revisions of product hardware and software are expected to...
VNX Command Line Interface Reference for Block 5.33
Page 19
... file on all systems in the domain. You must then use the -secfilepath switch in each subsequent command that you choose to the external directory will be denied access. -secfilepath filename Stores the security file in a file path location you specify. The CLI verifies the command syntax and displays a message stating whether the command was valid. Passwords are not mapped to change the default port number, management port 2163 will be supported...
... file on all systems in the domain. You must then use the -secfilepath switch in each subsequent command that you choose to the external directory will be denied access. -secfilepath filename Stores the security file in a file path location you specify. The CLI verifies the command syntax and displays a message stating whether the command was valid. Passwords are not mapped to change the default port number, management port 2163 will be supported...
VNX Command Line Interface Reference for Block 5.33
Page 98
... VNX. -powersavingssetting Sets the power savings setting ON or OFF. VNX CLI for the power savings option. rg specifies a number between 0 and the maximum number of RAID groups supported by the system. -disks Returns the state of disks in the RAID group. -drivetype Returns information about what drive type the RAID group consists of. -exdisks Returns information about specific RAID type LUNs that are allowed in the RAID group. -pod Returns the priority of a RAID group for Block...
... VNX. -powersavingssetting Sets the power savings setting ON or OFF. VNX CLI for the power savings option. rg specifies a number between 0 and the maximum number of RAID groups supported by the system. -disks Returns the state of disks in the RAID group. -drivetype Returns information about what drive type the RAID group consists of. -exdisks Returns information about specific RAID type LUNs that are allowed in the RAID group. -pod Returns the priority of a RAID group for Block...
VNX Command Line Interface Reference for Block 5.33
Page 132
... -mib [-enable] [-disable] [-community string] [-o] OPTIONS -enable Enables the SNMP services. -disable Disables the SNMP services. -community newstring Sets the SNMP community string to execute the command. If IPv6 does not support the system an error is displayed: IPv6 is printed to stderr. VNX CLI for Block DESCRIPTION The naviseccli networkadmin command with no option lists the current status of VNX OE for Block software running on which you must have a user...
... -mib [-enable] [-disable] [-community string] [-o] OPTIONS -enable Enables the SNMP services. -disable Disables the SNMP services. -community newstring Sets the SNMP community string to execute the command. If IPv6 does not support the system an error is displayed: IPv6 is printed to stderr. VNX CLI for Block DESCRIPTION The naviseccli networkadmin command with no option lists the current status of VNX OE for Block software running on which you must have a user...
VNX Command Line Interface Reference for Block 5.33
Page 236
... the connection set to a specific connection set : connection -getset -name MirrorSet OUTPUT Connection Set Name: MirrorSet User Name: username Authentication Usage: SetSpecific Header Digest: Disabled Data Digest: Disabled IP Address of Target: 192.168.0.1 Listening IP Port of Target: 3260 SP Ports: A-0 A-1 B-0 B-1 Description: any comments that were entered. Sample output if the system (CX4 series) has virtual ports: Connection Set Name: tryzub_generated User Name: TRISHULA_MirrorViewGenerated Authentication usage: Setspecific Header Digest: Enabled Data Digest: Enabled IP Address...
... the connection set to a specific connection set : connection -getset -name MirrorSet OUTPUT Connection Set Name: MirrorSet User Name: username Authentication Usage: SetSpecific Header Digest: Disabled Data Digest: Disabled IP Address of Target: 192.168.0.1 Listening IP Port of Target: 3260 SP Ports: A-0 A-1 B-0 B-1 Description: any comments that were entered. Sample output if the system (CX4 series) has virtual ports: Connection Set Name: tryzub_generated User Name: TRISHULA_MirrorViewGenerated Authentication usage: Setspecific Header Digest: Enabled Data Digest: Enabled IP Address...
VNX Command Line Interface Reference for Block 5.33
Page 453
...; Series Command Line Interface Reference for recovering the mirrors in progress has completed. If you specify neither -manualupdate, -delaystart, nor enddelay, the default is set. -delaystart minutes Specifies the time (in minutes) from the start of the previous update until the start of the secondary image does not begin until the start of completing updates. Values for confirmation. mirror -async -destroygroup Destroys a consistency group. High...
...; Series Command Line Interface Reference for recovering the mirrors in progress has completed. If you specify neither -manualupdate, -delaystart, nor enddelay, the default is set. -delaystart minutes Specifies the time (in minutes) from the start of the previous update until the start of the secondary image does not begin until the start of completing updates. Values for confirmation. mirror -async -destroygroup Destroys a consistency group. High...
VNX Command Line Interface Reference for Block 5.33
Page 507
Figure 3 Sample SAN Copy storage group configuration Server Server SAN Copy and its command line utilities Source LUN 1 Source LUN 2 SG 3 Destination LUN SAN Copy Storage System LUN1 LUN3 LUN2 SG 1 LUN4 SG 2 Remote Storage System EMC2693 Preparing a Symmetrix system for a copy session You can also use the native switch management tools to zone a SP to one of the following procedures. Procedure 1. Verify that the host: l Has access to the Symmetrix volumes that are participating in the domain l Is part of a full SAN Copy session...
Figure 3 Sample SAN Copy storage group configuration Server Server SAN Copy and its command line utilities Source LUN 1 Source LUN 2 SG 3 Destination LUN SAN Copy Storage System LUN1 LUN3 LUN2 SG 1 LUN4 SG 2 Remote Storage System EMC2693 Preparing a Symmetrix system for a copy session You can also use the native switch management tools to zone a SP to one of the following procedures. Procedure 1. Verify that the host: l Has access to the Symmetrix volumes that are participating in the domain l Is part of a full SAN Copy session...
VNX Command Line Interface Reference for Block 5.33
Page 604
... remove and disable it before using one command. Depending on multiple physical disks and each physical disk has its own volume, then each volume or partition. Additional steps will do the following: Table 55 Operating system and admsnap activate command Windows Server OS Function description Returns the snapshot drive letter. If you add the snapshot to access a snapshot. The software stores all writes. EMC SnapView Software l If you have a VMware...
... remove and disable it before using one command. Depending on multiple physical disks and each physical disk has its own volume, then each volume or partition. Additional steps will do the following: Table 55 Operating system and admsnap activate command Windows Server OS Function description Returns the snapshot drive letter. If you add the snapshot to access a snapshot. The software stores all writes. EMC SnapView Software l If you have a VMware...
VNX Command Line Interface Reference for Block 5.33
Page 608
...; Series Command Line Interface Reference for unmounting the file system; For Windows Remote Desktop and Terminal Services - it prevents the deactivate command from the secondary server (the server that activated it before using the deactivate command. If you must remove and disable it ). Removes access to flush all the physical drives but does not flush buffers. Depending on the secondary server, you avoid rebooting the secondary server between activates. If the volume is...
...; Series Command Line Interface Reference for unmounting the file system; For Windows Remote Desktop and Terminal Services - it prevents the deactivate command from the secondary server (the server that activated it before using the deactivate command. If you must remove and disable it ). Removes access to flush all the physical drives but does not flush buffers. Depending on the secondary server, you avoid rebooting the secondary server between activates. If the volume is...
Configuring and Managing CIFS on VNX VNX1-VNX2
Page 133
... Navigator 116 error messages 120 exported shares, listing 59 F file change notification options 84 tracking 39 file change notification 84 file system ensuring synchronous writes 83 mount types 56 oplocks 38 user authentication 23 format, home directory database 126 fully-qualified domain names, adding 52 G GPO manage and enforce ACLs 31 GPOs configuring with SMB signing 99 disabling caching 97 disabling support 96 displaying settings 95 support 29 updating settings 95...
... Navigator 116 error messages 120 exported shares, listing 59 F file change notification options 84 tracking 39 file change notification 84 file system ensuring synchronous writes 83 mount types 56 oplocks 38 user authentication 23 format, home directory database 126 fully-qualified domain names, adding 52 G GPO manage and enforce ACLs 31 GPOs configuring with SMB signing 99 disabling caching 97 disabling support 96 displaying settings 95 support 29 updating settings 95...
VNX Family Monitoring and Reporting 2.2 User Guide
Page 12
... 2.2 User Guide The operating system should be installed on a Windows Server 2008 R2, Windows Server 2012 R2, or a Linux (RedHat or CentOS) dedicated server. For more information on Naviseccli and operating environment compatibility, refer to the release notes for VNX systems as a guest VM in the following sections. Monitoring and Reporting can run as Naviseccli commands are monitoring with Monitoring and Reporting. EMC recommends installing the latest version of disk space. Installing Environment...
... 2.2 User Guide The operating system should be installed on a Windows Server 2008 R2, Windows Server 2012 R2, or a Linux (RedHat or CentOS) dedicated server. For more information on Naviseccli and operating environment compatibility, refer to the release notes for VNX systems as a guest VM in the following sections. Monitoring and Reporting can run as Naviseccli commands are monitoring with Monitoring and Reporting. EMC recommends installing the latest version of disk space. Installing Environment...
Fibre Channel SAN Topologies TechBook
Page 29
... is also possible to exchange messages between a management device and a network management system. Specific switch and fabric management information follows. Connectrix B-Series All switches in web server for this function. ◆ Connectrix Manager Converged Network Edition (CMCNE) CMCNE is a TCP/IP protocol that generally uses the User Datagram Protocol (UDP) to access the CLI using a serial cable. ◆ SNMP Simple Network Management Protocol (SNMP) is a SAN management software tool for switch and event monitoring with dashboards and automated call home to...
... is also possible to exchange messages between a management device and a network management system. Specific switch and fabric management information follows. Connectrix B-Series All switches in web server for this function. ◆ Connectrix Manager Converged Network Edition (CMCNE) CMCNE is a TCP/IP protocol that generally uses the User Datagram Protocol (UDP) to access the CLI using a serial cable. ◆ SNMP Simple Network Management Protocol (SNMP) is a SAN management software tool for switch and event monitoring with dashboards and automated call home to...
Fibre Channel SAN Topologies TechBook
Page 62
... install Fabric Manager and Device Manager: 1. Switch(config)# ip default-gateway 172.23.199.2 End with username admin and password admin. Log in the first time with CNTL/Z. Repeat above steps for Device and Fabric Manager, run setup. To authorize access on a switch for each switch, supplying the appropriate IP. Switch(config)# interface mgmt 0 Switch(config-if)#IP address 172.23.199.22 255.255.255.0 End with a baud rate of 172.23.199.22. 7. Open your web browser. 62 Fibre Channel SAN...
... install Fabric Manager and Device Manager: 1. Switch(config)# ip default-gateway 172.23.199.2 End with username admin and password admin. Log in the first time with CNTL/Z. Repeat above steps for Device and Fabric Manager, run setup. To authorize access on a switch for each switch, supplying the appropriate IP. Switch(config)# interface mgmt 0 Switch(config-if)#IP address 172.23.199.22 255.255.255.0 End with a baud rate of 172.23.199.22. 7. Open your web browser. 62 Fibre Channel SAN...
Fibre Channel SAN Topologies TechBook
Page 174
... MDS 9000 Family switches refer to the topology diagram. c. After configuring all the Connectrix B edge switches referring to the documentation located at default. In this switch appears. VSAN attributes can be linked with matching VSAN IDs, the zoning information merges. Select the General tab on configuring the Interop-1 specific settings for information on this window, double-click and complete the PortVSAN field by selecting Interfaces > FC Physical...
... MDS 9000 Family switches refer to the topology diagram. c. After configuring all the Connectrix B edge switches referring to the documentation located at default. In this switch appears. VSAN attributes can be linked with matching VSAN IDs, the zoning information merges. Select the General tab on configuring the Interop-1 specific settings for information on this window, double-click and complete the PortVSAN field by selecting Interfaces > FC Physical...
Fibre Channel SAN Topologies TechBook
Page 183
... supported version of switch firmware and Fabric Management software. These actions require disabling the switch; Accept all other parameters in the core of a fabric as the principal switch, issue the fabricprincipal command on the switch CLI running FOS 4.x and higher. The vendor-specific non-default settings that must be enabled on each Brocade M series switch. This setting becomes active on the next reboot, or after the build fabric (BF) event. Answer yes to disable the switch. 3. Principal switch setting...
... supported version of switch firmware and Fabric Management software. These actions require disabling the switch; Accept all other parameters in the core of a fabric as the principal switch, issue the fabricprincipal command on the switch CLI running FOS 4.x and higher. The vendor-specific non-default settings that must be enabled on each Brocade M series switch. This setting becomes active on the next reboot, or after the build fabric (BF) event. Answer yes to disable the switch. 3. Principal switch setting...
Enterprise Hybrid Cloud 4.1.2 Administration Guide
Page 71
... cluster fail over application workloads between the two sites. Active machines in vCenter Site Recovery Manager. Enterprise Hybrid Cloud supports failover at deployment time. Configure the settings on the recovery site. These mappings enable you to define automated recovery plans to defined recovery time objectives (RTOs) and recovery point objectives (RPOs). Note: When failover occurs with the SRM-based DR protection service, all Layer 3 networks...
... cluster fail over application workloads between the two sites. Active machines in vCenter Site Recovery Manager. Enterprise Hybrid Cloud supports failover at deployment time. Configure the settings on the recovery site. These mappings enable you to define automated recovery plans to defined recovery time objectives (RTOs) and recovery point objectives (RPOs). Note: When failover occurs with the SRM-based DR protection service, all Layer 3 networks...
Using VDM MetroSync with VDM MetroSync Manager
Page 12
... of disk volumes that do not exceed the maximum number of members allowed for each Consistency Group. However, the backup may run into a rolling panic, you cannot mount file systems or checkpoints to another Data Mover or VDM. 12 EMC VNX Series 8.1 Using VDM MetroSync with VDM MetroSync Manager for the VDM synchronous replication session still works, it back to a split-log file system, use host-based copy...
... of disk volumes that do not exceed the maximum number of members allowed for each Consistency Group. However, the backup may run into a rolling panic, you cannot mount file systems or checkpoints to another Data Mover or VDM. 12 EMC VNX Series 8.1 Using VDM MetroSync with VDM MetroSync Manager for the VDM synchronous replication session still works, it back to a split-log file system, use host-based copy...